Home

TDS3000B Series Digital Phosphor Oscilloscopes User Manual

image

Contents

1. A Appendix A Specifications This appendix contains specifications for the TDS3000B Series oscilloscopes All specifications are guaranteed unless noted as typical Typical specifications are provided for your convenience but are not guaranteed Specifications that are marked with the 1 symbol are checked in Appendix E Performance Verification All specifications apply to all TDS3000B Series models unless noted otherwise To meet specifications two conditions must first be met m The oscilloscope must have been operating continuously for twenty minutes within the operating temperature range specified m You must perform the Compensate Signal Path operation described on page 1 4 If the operating temperature changes by more than 10 C you must perform the Compensate Signal Path operation again Specifications Acquisition Acquisition modes Sample Normal Peak detect Envelope and Average Single Sequence Acquisition mode Acquisition stops after Sample Peak Detect One acquisition all channels simultaneously Average Envelope N acquisitions all channels simultaneously N is settable from 2 to 256 or co for Enve lope With compliments Helmut Singer Elektronik www helmut singer de info helmut singer de fon 49 241 155 315 fax 49 241 152 066 Feldchen 16 24 D 52070 Aachen Germany TDS3000B Series User Manual A 1 Appendix A Specifications Specifications cont Inputs Input coupling Inpu
2. B Normal 100 S s to 100 S s to 100 S s to 1GS s 2 5 GS s 5 GS s Fast trigger 5 S s to 5 S s to 5 S s to 1 25 GS s 2 5 GS s 5 GS s Seconds division 4 ns div to 2 ns div to 1 ns div to range 10 s div 10 s div 10 s div TDS3000B Series User Manual A5 Appendix A Specifications Specifications cont Horizontal i Sample rate and 20 ppm over any gt 1 ms time interval delay time accuracy Trigger External trigger input TDS3012B TDS3032B TDS3052B typical 1 MQ in parallel with 17 pF TekProbe compatible TDS 3014B TDS3034B TDS3054B 1 MQ in parallel with 52 pF not Tekprobe compatible External trigger Overvoltage category Maximum voltage maximum voltage CAT Environment refer to 150 Vams 400 Vox page A 14 CAT II Environment refer to 100 Vrms 400 Vox page A 14 For steady state sinusoidal waveforms derate at 20 dB decade above 200 kHz to 13 Vp at 3 MHz and above External trigger maxi 0 V from chassis BNC ground to earth ground or mum floating voltage a i 9 9 30 Vrms 42 Vox only under these conditions no signal voltages gt 30 Vrms gt 42 Vpk all common leads connected to the same voltage no grounded peripherals attached Edge trigger Sensitivity ee Any channel DC coupled 0 35 div from DC to 50 MHz increasing to 1 div at oscillo scope bandwidth Edge trigger sensitivity External trigger 100 mV from DC to 50 MHz typical increasing to 500 mV at 300 MHz External 10 tri
3. ent at this level includes appliances portable tools and similar products Equipment is usually cord connected CAT Secondary signal level or battery operated circuits of electronic equipment With compliments Helmut Singer Elektronik www helmut singer de info helmut singer de fon 49 241 155 315 fax 49 241 152 066 Feldchen 16 24 D 52070 Aachen Germany A 14 TDS3000B Series User Manual
4. for each channel sampled simultaneously at BNC 1 mV div to 10 V div ImV div to 1 V div Fine SCALE Adjustable with gt 1 resolution Polarity Normal and Invert Position range 5 divisions y Analog bandwidth Bandwidth limit set to Full operating ambient lt 30 C derate 500 1 C above 30 C a fs es Scale range TDS3012B TDS3032B TDS3052B with standard probe TDS3014B TDS3034B TDS3054B 5mV divto 100 MHz 300 MHz 500 MHz 1 V div 2 mV divto 100 MHz 250 MHz 300 MHz 4 98 mV div LmVidivto 90 MHz 150 MHz 175 MHz 1 99 mV div Calculated rise time 3 5 ns 1 2 ns 0 7 ns typical TDS3000B Series User Manual A 3 Appendix A Specifications Specifications cont Vertical Analog bandwidth limit typical Lower frequency limit AC coupled typical Peak detect or Envelope pulse re sponse typical DC gain accuracy DC measurement accuracy Sample acquisition mode typical Average acquisition mode 216 averages Selectable between 20 MHz 150 MHz not available on TDS 3012B or TDS3014B or Full 7 Hz for 1 MQ reduced by a factor of ten when using a 10X passive probe 140 kHz for 50 Q Minimum width of pulse with amplitude of gt 2 div to capture 50 or greater amplitude Sample rates lt 125 MS s Sample rates 2250 MS s 2 derated at 0 025 C for temperatures below 18 C and above 30 C in Sample or Average acquisition mode Measurement type DC Accuracy in volts Abso
5. gger 500 mV from DC to 50 MHz increasing to 3 V at 300 MHz Any channel NOISE REJ 3 5 times the DC coupled limits coupled A 6 TDS3000B Series User Manual Appendix A Specifications Specifications cont Trigger 1 5 times the DC coupled limit from DC to 30 kHz attenuates Signals above 30 kHz Edge trigger sensitivity Any channel HF RE coupled typical Any channel LF REJ coupled 1 5 times the DC coupled limits for frequencies above 80 kHz attenuates signals below 80 kHz Trigger level range Sensitivity Any channel 8 divisions from center of screen 8 divisions from 0 V if LF RE trigger coupled External external 800 mV External 10 trigger 8 V Fixed at the midlevel of the AC line SET LEVEL TO 50 Operates with input signals gt 45 Hz typical Trigger level accuracy Sensitivity ane 0 2 divisions Va Trigger holdoff range 250 8 ns to 10 s TDS3000B Series User Manual A 7 Appendix A Specifications Specifications cont Trigger Video trigger sensitivity Triggers on negative sync of NTSC PAL or SECAM signal Any channel 0 6 to 2 5 divisions of video sync tip External trigger 150 mV to 625 mV of video sync tip External 10 trigger 1 5 V to 6 25 V of video sync tip B Trigger Trigger After Time Trigger After B Events Range 13 2 ns to 50 s 1 event to 9 999 999 events Minimum time 5ns from the end of the time 5 ns between the A trigger between arm and period and the B
6. lute measurement of any 0 021 x reading offset waveform point and High position offset accuracy Low Max and Min measure 0 15 div 0 6 mV ments Delta voltage between any two 0 021 x reading points on a waveform and all 0 15 div 1 2 mV other automatic measure ments Absolute measurement of any 0 02 x reading offset waveform point and High position offset accuracy Low Max and Min measure 0 1 div ments Delta voltage between two 0 021 x reading points on a waveform and all 0 05 div other automatic measure ments 1 0 02 term gain component derated at 0 00025 C above 30 C A 4 TDS3000B Series User Manual Appendix A Specifications Specifications cont Vertical Offset range Offset range Offset Accuracy Accuracy 1 mV div to 0 002 x net offset 1 5 mV 100 mV div 0 1 divx V div setting 101 mV div to 0 0025 x netoffset 15 mV 1 V div 0 1 divx V div setting 1 01 V divto 0 0025 x netoffset 150 mV 10 V div 0 1 divx V div setting Horizontal Acquisition horizontal Normal Fast trigger resolution 10 000 point record 500 point record TDS3032B TDS3032B Maximum TDS3034B TDS3034B acquisition rate TDS3012B TDS3052B TDS3012B TDS3052B typical TDS3014B TDS3054B TDS3014B TDS3054B 400 wfms s 700 wfms s 2 600 wfms s 3 600 wfms s Sample rate range TDS3012B TDS3032B TDS3052B TDS3014B TDS3034B TDS3054
7. n each axis Drop resistance typical Survives a 152 mm 6 in drop onto concrete with only cosmetic damage Mechanical Size Height 176 mm 6 9 in 229 mm 9 0 in including handle Width 375 mm 14 75 in Depth 149 mm 5 9 in Weight Oscilloscope only 3 2 kg 7 0 Ibs With accessories and carry case 4 1 kg 9 0 Ibs When packaged for domestic shipment 5 5 kg 12 0 Ibs Optional battery pack 2 4 kg 5 2 Ibs TDS3000B Series User Manual A 11 Appendix A Specifications Specifications cont EMC certifications and compliances Meets the intent of Directive 89 336 EEC for Electromagnetic Compatibility Compliance was demonstrated to the following Specifications as listed in the Official J ournal of the European Communities EN 61326 EMC requirements for Class A electrical equipment for measurement control and laboratory use 12 IEC 61000 4 2 Electrostatic discharge immunity Performance criterion B IEC 61000 4 3 RF electromagnetic field immunity Performance criterion B 8 IEC 61000 4 4 Electrical fast transient ourst immunity Performance criterion B IEC 61000 4 5 Power line surge immunity Performance criterion B IEC 61000 4 6 Conducted RF immunity Performance criterion B 4 IEC 61000 4 11 Voltage dips and interruptions immunity Performance criterion B EN 61000 3 2 AC power line harmonic emissions EMC Compliance European Union A 12 TDS3000B Series User Manual Appendix A S
8. pecifications Specifications cont EMC certifications and compliances Meets the intent of Australian EMC Framework as demonstrated to the following specification AS NZS 2064 1 2 This product was certified by the GOST ministry of Russia to be in compliance with all applicable EMC regulations EMC Compliance Australia New Zealand EMC Compliance Russia Emissions comply with FCC Code of Federal Regulations 47 Part 15 Subpart B Class A Limits 1 Emissions that exceed the levels required by this standard may occur when this equipment is connected to a test object FCC Compliance U S A 2 To ensure compliance to the standards listed above attach only high quality shielded cables to this instrument High quality shielded cables typically are braid and foil types that have low impedance connections to shielded connectors at both ends 3 The increase in trace noise while subjected to a test field 3 V m over the frequency range 80 MHz to 1 GHz with 80 amplitude modulation at 1 kHz is not to exceed 6 major dvisions peak to peak Ambient conducted fields may induce triggering when the trigger threshold is offset less than 3 major divisions from ground reference 4 The increase in trace noise while subjected to a test field 3 V m over the frequency range 150 kHz to 80 MHz with 80 amplitude modulation at 1 kHz is not to exceed 4 major dvisions peak to peak Ambient conducted fields may induce triggering when the
9. s cont Power sources AC line power Operates the oscilloscope and charges the optional internal battery Source voltage 90 Vgms to 250 Vas continuous range Source frequency 47 Hz to 440 Hz Power consumption 75 W maximum Battery power Optional accessory TDS3BATNIMH rechargeable NiMH battery pack Operating time 2 hours depending on operating conditions typical Battery charge time 18 hours in the oscilloscope 3 hours in the optional external typical charger TDS3CHG Line fuse Internal not user replaceable Environmental Temperature Operating range no disk installed 5 C to 50 C Nonoperating range no disk installed 20 C to 60 C Typical operating range for floppy disks 10 C to 50 C Humidity Operating range no disk installed 20 to 80 RH below 32 C derate upper limit to 21 RH at 50 C Nonoperating range no disk installed 5 to 90 RH below 41 C derate upper limit to 30 RH at 60 C Typical operating range for floppy disks 20 to 80 RH below 32 C derate upper limit to 21 RH at50 C Pollution Degree 2 Typical home or office environment Pollution Degree A 10 TDS3000B Series User Manual Appendix A Specifications Specifications cont Environmental Altitude Operating limit 3000 m Nonoperating limit 15 000 m Random vibration Operating 0 31 ggms from 5 Hz to 500 Hz 10 minutes on each axis Nonoperating 2 46 gams from 5 Hz to 500 Hz 10 minutes o
10. t impedance DC coupled Maximum voltage at input BNC 1 MQ Maximum voltage at input BNC 50 Q Maximum floating voltage Channel to channel crosstalk typical A 2 DC AC or GND Channel input remains terminated when using GND coupling 1 MQ 1 in parallel with 13 pF 2 pF TekP robe compatible 50 Q 1 VSWR lt 1 5 1 from DC to 500 MHz typical Overvoltage category Maximum voltage CAT Environment refer to 150 Vrms 400 Vox page A 14 CAT II Environment refer to page A 14 For steady state sinusoidal waveforms derate at 20 dB decade above 200 kHz to 13 V at 3 MHz and above 5 Vams with peaks lt 30 V 100 Vrms 400 Vox 0 V from chassis BNC ground to earth ground or 30 Vrms 42 Vox only under these conditions no signal voltages gt 30 Vrms gt 42 VpK all common leads connected to the same voltage no grounded peripherals attached Measured on one channel with test signal applied to another channel and with the same scale and coupling settings on each channel range TDS3014B TDS3034B TDS3054B TDS3000B Series User Manual Appendix A Specifications Specifications cont Inputs Differential delay 100 ps between any two channels with the same scale and typical coupling settings Vertical Number of channels TDS3012B TDS3032B TDS3014B TDS3034B TDS3052B TDS3054B 2 plus external trigger input 4 plus external trigger input Digitizers 9 bit resolution separate digitizers
11. trigger event event and the first B trigger trigger typical event Minimum Pulse B event width 2 ns Width typical Maximum Fre B event frequency 250 MHz quency typical A 8 TDS3000B Series User Manual Appendix A Specifications Specifications cont Display Display screen Display resolution Backlight intensity typical Display color External display filter I O ports Ethernet port Parallel printer port GPIB interface RS 232 interface VGA signal output Probe compensator output typical Miscellaneous Nonvolatile memory Floppy disk Internal clock TDS3000B Series User Manual 6 5 in 165 mm diagonal color liquid crystal 640 horizontal by 480 vertical pixels 200 cd m2 Up to 16 colors fixed palette Scratch resistant tempered glass 10BaseT RJ 45 female connector all models Centronics compatible DB 25 female connector Available in optional accessory TDS 3GV DB 9 male connector available in optional accessory TDS3GV TDS3EM DB 15 female connector 31 6 kHz sync rate EIA RS 343A compliant available in optional accessory TDS3GV 5 0 V into gt 1 MQ load frequency 1 kHz Typical retention time gt 5 years for front panel settings unlimited for saved waveforms and setups 3 5 in DOS format 720 KB or 1 44 MB compatible Provides date time stamp for stored data and the current time and date to the front panel if enabled A 9 Appendix A Specifications Specification
12. trigger threshold is offset less than 2 major divisions from ground reference TDS3000B Series User Manual A 13 Appendix A Specifications Specifications cont Safety certifications and compliances EC Declaration of Conformity Low Voltage TDS 3000B Series P3010 and P6139A P3010 and P6139A Approvals TDS 3000B Series P3010 and P6139A P3010 and P6139A Installation Category Descriptions Compliance was demonstrated to the following specification as listed in the Official J ournal of the European Communities Low Voltage Directive 73 23 EEC as ammended by 93 68 EEC EN 61010 1 A2 1995 Safety requirements for electrical equipment for measurement control and laboratory use EN 61010 2 031 1995 Particular requirements for hand held probe assemblies for electrical measurement and test equipment UL3111 1 Standard for electrical measuring and test equipment CAN CSA C22 2 No 1010 1 Safety requirements for electrical equipment for measurement control and laboratory use EN 61010 2 031 1995 Particular requirements for hand held probe assemblies for electrical measurement and test equipment Terminals on this product may have different installation category designations The installation categories are CAT IIl Distribution level mains usually permanently connected Equipment at this level is typically in a fixed industrial location CAT II Local level mains wall sockets Equipm