1. 10Base T 2 pair UTP STP Cat 3 4 5 up to 100m 100Base TX 2 pair UTP STP Cat 5 up to 100m Ethernet Extender 24 or 26AWG twisted pair copper wire LED Indicators Per Unit 2 LEDs POWER TEST Per Port LAN1 LAN2 RJ 45 2 LEDs Link Activity Speed Line RJ 48 2 LEDs LOOP1 LOOP2 Dimensions 260mm W x 151mm D x 44mm H 10 24 W x 5 94 D x 1 73 H Weight 2 5Kg 5 5 1lbs Power 100 240VAC 50 60Hz Internal Universal PSU Power Consumption 8W Max Operating Temperature 0 C 50 C 32 F 122 F Storage Temperature 20 C 70 C 4 F 158 F Humidity 5 95 non condensing Emissions CE Mark Class A FCC Part 15 Class A VCCI Class A 20
2. R will follow the speed of STU C 14 Managed SHDSL Ethernet Extender When setting for adaptive rate 2 or more activation cycles are necessary The system will automatically adapt to maximum speed according to the loop distances The maximum speed is 4608Kbps for 1 pair mode and 9216Kbps for 2 pair mode Default Configuration Setting Now the settings are STU C 1 Pair and Adaptive speed Press ESC to quit ESC quit Table 9 5 Default Configuration Setting screen When Default Configuration is selected all the settings of this Managed SHDSL Ethernet Extender will go back to default settings For the screen as shown in Table 9 5 it indicates setting is finished and press lt ESC gt key will be back to previous screen The default settings of this Managed SHDSL Ethernet Extender are as following STU C 1 Pair Adaptive speed 15 Managed SHDSL Ethernet Extender 9 3 Status Screen The Status screen shows the connection status of this Managed SHDSL Ethernet Extender unit The screen covers two selections System Information and System Status For details please refer to Table 9 6 Status 1 System Information 2 System Status Select 1 2 ENTER select ESC quit Table 9 6 Status screen 16 Managed SHDSL Ethernet Extender System Information System Information Firmware Version 2 5 Vendor Model SHDSL Vendor Information Table 9 7 System Information screen Items list in the above screen
3. are explained as follows Firmware Version Indicates the firmware version in this unit Vendor Model Indicates this device s vendor model name Vendor Information Indicates the vendor s web site information 17 Managed SHDSL Ethernet Extender System Status screen System Status DSL mode STU C 2 Pairs Speed setting Adaptive Speed actual kbps 9216 Link status of pair 1 up Link status of pair 2 up Noise Margin of pair 1 dB 08 Noise Margin of pair 2 dB 09 Line Attenuation of pair 1 dB 22 Line Attenuation of pair 2 dB 22 Activation state of pair 1 16 Activation state of pair 2 16 ESC quit Table 9 8 System Status screen The distance of this example is 6K ft and 26AWG Items list in the above screen are explained as follows DSL mode Indicates the current DSL mode setting Speed setting Indicates the current DSL speed setting Speed actual Kbps Indicates the actual DSL speed in kilobit per second Link status of pair 1 Indicates the DSL connection status either up or down for pair 1 Link status of pair 2 Indicates the DSL connection status either up or down for pair 2 Noise Margin of pair 1 dB Indicates the Noise Margin in dB of pair 1 Noise Margin of pair 2 dB Indicates the Noise Margin in dB of pair 2 18 Managed SHDSL Ethernet Extender Line Attenuation of pair 1 dB Indicates the Line Attenuation value in dB of pair 1 The maximum val
4. 2 Pair Managed SHDSL Ethernet Extender User s Manual Managed SHDSL Ethernet Extender 1 Quick Start Guide This quick start guide describes how to install and use the Managed SHDSL Ethernet Extender This is the Ethernet Extender of choice to extend 10 100 Ethernet circuits by using existing straight pair copper wire 1 1 Physical Description 1 1 1 The Port Status LEDs and Power Inputs 9600 N 8 1 TEST LOOPZ 100 100 12 O O O POWER LOOPT LANI LAN ON NI N i LA LAN2 _ wm wm wa OFF LEDs State Indication POWER Green On Power supply is normal TEST Yellow On Self testing after powered on Line Flash SHDSL connection is in progress LOOPI Green On Loop connects successfully Flash SHDSL connection is in progress Oe ee On Loop2 connects successfully Ethernet On LANI port is in connection LANE Cee Flash Data activity on LANI port 10 100M Green On LAN Ethernet connection is at 100Mbps On LAN2 port is in connection aaa cates Flash Data activity on LAN2 port 10 100M Green On LAN Ethernet connection is at 1 OOMbps Line Managed SHDSL Ethernet Extender 1 1 2 The 10 100Base TX and Ethernet Extender Connectors The 10 100Base TX Connection The following lists the pinouts of 10 100Base TX RJ 45 connector Pin Regular Ports Uplink ports 1 Output Transmit Data Input R
5. ace Main Menu 1 Configuration 2 Status Select 1 2 ENTER select Table 9 1 Main Menu The pull down tree structure of the main menu is shown in Figure 9 2 DSL Mode Configuration DSL Speed Default Configuration Main Menu System Information Status System Status Figure 9 2 Pull down Tree Structure of the main menu ll Managed SHDSL Ethernet Extender 9 2 Configuration Screen Configuration screen will display the selections of connection for the Managed SHDSL Ethernet Extender unit and the screen includes three selections DSL Mode Settings DSL Speed Settings and Default Configuration For details please refer to Table 9 2 Configuration 1 DSL Mode 2 DSL Speed 3 Default Configuration Select 1 3 ESC quit Table 9 2 Configuration screen 12 Managed SHDSL Ethernet Extender DSL Mode Settings DSL Mode imuR Min CO RT PAIR Noise Margin STU C 2 Pairs NM 1 dB ARROW RIGHTICARROW LEFT type SPACE option ENTER select ESC quit Table 9 3 DSL Mode Settings screen This screen provides DSL mode settings and user can update the settings from this screen CO RT The item of CO RT has 2 options STU C and STU R To establish a successful connection for two Managed SHDSL Ethernet Extender units it is necessary to set one unit to STU C and the other unit to STU R 2P 1P The item of 2P 1P has 2 options 1 Pair and 2 Pairs This Managed SHDSL Ethernet Extender supp
6. d Status Welcome to Ethernet Extender User Interface Hain Menu 1 Configuration 2 Status Select 1 2 ENTER select 1 3 2 Pull down Tree Structure of Main Menu The pull down tree structure of the main menu is shown as below DSL Mode Configuration DSL Speed Default Configuration Main au Menu System Information Status System Status Managed SHDSL Ethernet Extender 2 Table of Contents Lb QUICK START GUIDE inac cocaavedseateusivceucences 1 1 1 PHY SICAL DESCRIPTION annens a sistas aise cou ees eaten tesa 1 1 1 1 The Port Status LEDs and Power Inputs 1ccsssssesscesscesscevecesecnseesecnsecoasonssonsvensesseesseesscesesesecaeenaesnaessascnasonesensees 1 1 1 2 The 10 100Base TX and Ethernet Extender COnne ctor cccccccescceessecessceesecescceesceceeceeaceceseeeeaceceeceeaeecsaeeeeaeecnaeeesaes 2 1 1 3 The Data Rate and Distance of Ethernet Extender Pott c cccccccesccesscesecusecuseenseeseeeseeseceseensecusecsecaecaecsaecaaeenaeensens 2 1 2 FUNCTIONAL DESCRIPTION s sesssseesessssecrrssssecrrrsssecerrsssecrressssceresssseeressss 3 1 3 CONSOLE CONFIGURATION sssssseeeeeeeesssssssseretereessessssseretrrreosesssssersrerreeses 3 LBD se Main ME a a da oo beta Ua EE E E NE 4 1 3 2 Pull down Tree Structure of Main Men en iresten niiae iradesi i iatras privi aiae oaio 4 2 TABLE OF CONTENTS wicisads cassccssebocccssctsontendshesmecwasdesssesiecennetessens 5 3 INTRODUCTIONS wsccdisteicese
7. eceive Data 2 Output Transmit Data Input Receive Data Ls 3 Input Receive Data Output Transmit Data E 5 NC NC an 6 Input Receive Data Output Transmit Data 7 NC NC 8 NC NC The Ethernet Extender Connection F The RJ 48 connector pinouts for SHDSL line interface T Pin 4 amp Pin 5 for Loop 1 Pin 3 f Pin 1 amp Pin 2 for Loop 2 1 1 3 The Data Rate and Distance of Ethernet Extender Port 1 pair 2 pair Max Reach m Max Reach ft Data Rate Kbps Data Rate Kbps 4 608 9 216 1 828 6 000 3 072 6 144 2 895 9 500 2 304 4 608 3 505 11 500 2 048 4 096 3 657 12 000 1 544 3 088 3 962 13 000 1 152 2 304 4 419 14 500 768 1 536 4 572 15 000 512 1 024 5 029 16 500 384 768 5 334 17 500 256 512 5 791 19 000 192 384 6 248 20 500 lt Note gt This table is based on SHDSL connection with 1dB noise Managed SHDSL Ethernet Extender 1 2 Functional Description ITU T Rec G 991 2 G shdsl bis Compliance SHDSL Trellis Coded Pulse Amplitude Modulation TCPAM Line Code Fixed Data Rate Selection from 10 8Mbps to 128Kbps for 2 pair SHDSL lines Adaptive Data Rate from 4608Kbps to 192Kbps for 1 pair SHDSL mode Adaptive Data Rate from 9216Kbps to 384Kbps for 2 pair SHDSL mode Maximum Transmission Distance 22 500 ft over 26AWG twisted pair Noise Margin 2 1 dB is guaranteed for fixed rate and adaptive rate modes STU R follows STU C s speed
8. for 192Kbps 2304Kbps in 1 pair fixed rate mode STU R follows STU C s speed for 384Kbps 4608Kbps in 2 pair fixed rate mode RJ 48 Connector for SHDSL line connections Two RJ 45 Connectors for 10 100Base TX Ethernet Switch ports Ethernet Auto Negotiation for 10 100Base TX Ethernet Auto MDIX for Auto Tx Rx Swap Console Port for Network Management Configurations 8 LED status indicators Power feedings 100 240VAC 1 3 Console Configuration The Ethernet Extender provides an RS232C console port for user to monitor the OA amp M status through a VT100 terminal Connect the RS232 cable to the COM port of the computer Set the personal computer to VT100 or VT102 type through HyperTerminal Press the lt ESCAPE gt key and the main menu will be shown on the screen of the terminal The terminal operations can then start If the lt ESCAPE gt key is pressed and the screen of the terminal does not display this may be due to the incorrect COM port setting Choose the right COM port COM1 or COM2 on the computer and press the lt ESCAPE gt key again to make sure that the main menu appears on the terminal screen Note that the COM port should be set as below Baud rate Data bits Parity Stop bit Flow control 9600bps 8 none 1 none Managed SHDSL Ethernet Extender 1 3 1 Main Menu Main Menu will display the connection status of the Ethernet Extender and settings including two sections Configuration an
9. net connection is at 1OOMbps Managed SHDSL Ethernet Extender 9 Console Port Control The Managed SHDSL Ethernet Extender provides an RS232C console port for user to monitor the OA amp M status through a VT100 terminal This section covers the operation procedures settings and for all screen selections Connect the RS232 cable to the COM port of the computer as shown in the following diagram Set the personal computer to VT100 or VT102 type through HyperTerminal Press the lt ESCAPE gt key and the main menu will be shown on the screen of the terminal The terminal operations can then start If the lt ESCAPE gt key is pressed and the screen of the terminal does not display this may be due to the incorrect COM port setting Choose the right COM port COM1 or COM2 on the computer and press the lt ESCAPE gt key again to make sure that the main menu appears on the terminal screen Note that the COM port should be set as 9600bps none parity 8 data bit and 1 stop bit RS232 Cable Ti Console Port 9600 N 8 1 VT100 102 Terminal DB 9 Connector Managed SHDSL Ethernet Extender Figure 9 1 Connection for Console Port with RS232 Terminal 10 Managed SHDSL Ethernet Extender 9 1 Main Menu Main Menu will display the connection status of the Managed SHDSL Ethernet Extender unit and settings including two sections Configuration and Status For details please refer to Table 9 1 Welcome to Ethernet Extender User Interf
10. or SHDSL line connections Two RJ 45 Connectors for 10 100Base TX Ethernet Switch ports Ethernet Auto Negotiation for 10 100Base TX Ethernet Auto MDIX for Auto Tx Rx Swap Console Port for Network Management Configurations 8 LED status indicators Power feedings 100 240VAC 6 Packing Contents Inside the package you should find 1 One Managed SHDSL Ethernet Extender unit with dimension of 260x151x44 mm 2 One power cord 3 One CAT 5 Ethernet Cable 4 One User s Manual Please check if the packing is damaged before unpacking or any component is missing If so please contact your dealer immediately for replacement Managed SHDSL Ethernet Extender 7 Installation Procedures Step 1 Connect SHDSL Lines 2 pairs to RJ 48 connector on the Managed SHDSL Ethernet Extender back panel Pin 4 amp Pin 5 for Loop 1 Pin amp Pin 2 for Loop 2 RJ 48 Connector Pin Assignment for SHDSL Line Interface Step 2 Connect Ethernet to RJ 45 Port with CAT 5 LAN cable Step 3 Step 4 Step 5 Step 6 Connect the power cord to the Managed SHDSL Ethernet Extender AC outlet Turn on the power switch Set one Managed SHDSL Ethernet Extender as STU C from console port and the other Managed SHDSL Ethernet Extender as STU R Set the desired Data Rate for SHDSL connection from the console port Note that both Managed SHDSL Ethernet Extenders must set the same data rate settings Both units of Managed SHDSL Etherne
11. orts both 1 pair and 2 pair applications To establish a successful connection for two Managed SHDSL Ethernet Extender units it is necessary to set the two units to the same selection 13 Managed SHDSL Ethernet Extender DSL Speed Settings DSL Speed DSL Speed Setting Adaptive ARROW UP ARROW DOWN Joption ENTER select ESC quit Table 9 4 DSL Speed Settings screen This screen provides DSL Speed Settings and user can configure DSL speed to set the transmission rate For 1 pair setting in the DSL Mode menu the options are as following 64Kbps 128Kbps 192Kbps 256Kbps 384Kbps 512Kbps 768Kbps 1152Kbps 1536Kbps 1544Kbps 2048Kbps 2304Kbps 2560Kbps 3072Kbps 3584Kbps 4096Kbps 4608Kbps 5120Kbps 5696Kbps and Adaptive speed For 2 pair setting in the DSL Mode menu the options are as following 128Kbps 256Kbps 384Kbps 512Kbps 768Kbps 1024Kbps 1536Kbps 2304Kbps 3072Kbps 3088Kbps 4096Kbps 4608Kbps 5120Kbps 6144Kbps 7168Kbps 8192Kbps 9216Kbps 10 2Mbps 10 8Mbps and Adaptive speed The user must set both units of Managed SHDSL Ethernet Extender to the same speed selection in order to establish a successful connection for 1 pair 64Kbps 128Kbps 2560Kbps 3072Kbps 3584Kbps 4096Kbps 4608Kbps 5120Kbps 5696Kbps and for 2 pair 128Kbps 256Kbps 5120Kbps 6144Kbps 7168Kbps 8192Kbps 9216Kbps 10 2Mbps 10 8Mbps and Adaptive speed For the rest of speed options from 192Kbps up to 2304Kbps the STU
12. ps The Managed SHDSL Ethernet Extender provides a console port for user to configure the settings and to monitor the connection status Each Managed SHDSL Ethernet Extender can be configured into either STU C for central side or STU R for remote side The Managed SHDSL Ethernet Extender conforms to the ITU T Rec G 991 2 to meet G shdsl bis network requirements A pair of Managed SHDSL Ethernet Extender offers a cost effective symmetrical broadband solution for bandwidth hungry applications such as LAN to LAN connectivity Internet Access and VoIP applications over two twisted pairs 4 Application Notes Ethernet To Ethernet Bridge Extension 10 8Mbps at 7 000 ft Ethernet Ethernet Interface Interface Central Office SHDSL Copper Lines Remote Side STU C STU R Managed SHDSL Ethernet Extender 5 Features ITU T Rec G 991 2 G shdsl bis Compliance SHDSL Trellis Coded Pulse Amplitude Modulation TCPAM Line Code Fixed Data Rate Selection from 10 8Mbps to 128Kbps for 2 pair SHDSL lines Adaptive Data Rate from 4608Kbps to 192Kbps for 1 pair SHDSL mode Adaptive Data Rate from 9216Kbps to 384Kbps for 2 pair SHDSL mode Maximum Transmission Distance 22 500 ft over 26AWG twisted pair Noise Margin 2 1 dB is guaranteed for fixed rate and adaptive rate modes STU R follows STU C s speed for 192Kbps 2304Kbps in 1 pair fixed rate mode STU R follows STU C s speed for 384Kbps 4608Kbps in 2 pair fixed rate mode RJ 48 Connector f
13. stcssiesescecoueteedscsetcascescoaccssndeuesetscassseasssee 6 d APPLICATION NOTES oersoep eaae e a s SS 6 Des FEATURES a sssissss ivscvansssdasessscncvsauses ioecunteadsenetdsssesandonseesdisuesbcassseaceies 7 6 PACKING CONTEN ES cesa ia a 7 7 INSTALLATION PROCEDURES sseeeesssesessocessssoessssoocssssoessssssse 8 8 FRONT PANEL LED INDICATORG ccccssoocssccroeesseees 9 9 CONSOLE PORT CONTROL u ccscccccccrcccscccrccssscccccsoeee 10 9 1 MAIN MENU koerren sea tn EE EEE N EEEE REES 11 9 2 CONFIGURATION SCREEN Sj iiacdieiledaiicnmnaeisc dna aac aes 12 Das EAT SS CREE guor s aaun E O EEA E 16 10 SPECIFICATIONS ieot aaa ANERE 20 Managed SHDSL Ethernet Extender 3 Introductions The Managed SHDSL Ethernet Extender an SHDSL Single pair High bit rate Digital Subscriber Line LAN Extender provides a broadband full duplex transmission with bandwidth aggregation up to 10 8Mbps over 2 pairs of copper line for point to point LAN connectivity between two Ethernet networks The distance can reach up to 7 000 feet about 2 1 Km and 10 000 feet about 3 Km at the maximum rate of 10 8Mbps and 9 216Mbps for two pairs of 24AWG 0 5 mm copper wire and could reach even around 22 500 feet about 6 8 Km for 192Kbps With its rate adaptive features this Managed SHDSL Ethernet Extender may provide longer reach on transmission distance Users can also select a fixed data rate for the copper line ranging from 192Kbps to 10 8Mb
14. t Extender will automatically connect with each other Turn on the power switch and this Managed SHDSL Ethernet Extender will then execute self test routines There will be 2 or more handshaking cycles when adaptive rate is selected The system will automatically adapt to maximum rate according to the loop distances The maximum adaptive rate is 4608Kbps for l pair mode and 9216Kbps for 2 pair mode The maximum fixed data rate is 10 8Mbps Managed SHDSL Ethernet Extender 8 Front Panel LED Indicators There are 8 LED indicators on the front panel of the Managed SHDSL Ethernet Extender displaying the current status These LED indicators are described as following POWERI Green On shows Managed SHDSL Ethernet Extender power supply is TEST LOOPI J U LOOP2 J U LANI U 10 100M0 LAN2 U 10 100M0 normal Yellow On shows Managed SHDSL Ethernet Extender is self testing after powered on Green Flash shows SHDSL connection is in progress Green On shows SHDSL loop1 connects successfully Green Flash shows SHDSL connection is in progress Green On shows SHDSL loop2 connects successfully Green On shows LAN port is in connection Green Flash shows data activity on LAN port Green On shows LAN Ethernet connection is at 1OOMbps Green On shows LAN port is in connection Green Flash shows data activity on LAN2 port Green On shows LAN2 Ether
15. ue is 43 dB when the DSL distance is 22500 ft 26AWG Line Attenuation of pair 2 dB Indicates the Line Attenuation value in dB of pair 2 The maximum value is 43 dB when the DSL distance is 22500 ft 26A WG Activation state of pair 1 dB Indicated the DSL startup activation state of pair 1 The value starts from 05 and gradually reaches the final value 16 The value 16 is the DSL link up state value The general activation state sequence is 05 gt 20 gt 10 gt 12 gt 16 Activation state of pair 2 dB Indicated the DSL startup activation state of pair 2 The value starts from 05 and gradually reaches the final value 16 The value 16 is the DSL link up state value The general activation state sequence is 05 gt 20 gt 10 gt 12 gt 16 19 Managed SHDSL Ethernet Extender 10 Specifications Applicable Standards IEEE802 3 10Base T IEEE802 3u 100Base TX IEEE802 3x Ethernet over SHDSL Fixed Ports 2 x 10 100Mbps Ethernet port with RJ 45 connector 1 x Ethernet Extender port with RJ 48 connector Speed 10Base T 10 20Mbps for half full duplex 100Base TX 100 200Mbps for half full duplex Ethernet Extender Fixed Data Rate Selection 128Kbps to 10 8Mbps for 2 pair copper wire Adaptive Data Rate 192Kbps to 4608Kbps for 1 pair copper wire Adaptive Data Rate 384Kbps to 9216Kbps for 2 pair copper wire Switching Method Store and Forward Forwarding rate 14 880 148 810pps for 10 100Mbps Cable
Download Pdf Manuals
Related Search
Related Contents
RS40-user_manual- COMPLETE Operating Instructions Dräger FG4200 Texas Instruments TUSB3410 User's Manual Sunbeam WF6800 User's Manual LACTABOOST - Vital Concept USBメモリー型小型カメラ 取扱説明書 Pro-Line Boats Dual Console Series Owner`s manual IMPCO Large Engine Catalog - IMPCO Technologies Europe Copyright © All rights reserved.