UPS + AVR User's Manual

image

Contents

1. UPS fault Every other 2 sec 32 beeps in 2 sec alarm can Not be silenced Thermal alarm Every other 2 sec 32 beeps in 2 sec alarm can Not be silenced 5 4 Auto self test Function In normal mode of UPS turn on your equipment that connecting to the UPS and push the button on the front panel for self test he UPS will simulate a power outage and transfer your load to the UPS s battery If low battery warning sounds during the test it means that the battery set is weak and requires extended recharge If the warning of failed battery sounds it means that the battery set is damaged and requires replacement 13 5 5 Remote Control The UPS can be set for daily shutdown wake up This command must be set through the RS 232 interface When this function is set the timer inside the UPS will begin to run and the load will be turned off by the shutdown wake up schedule During the period of turn off to the next turn on the LCD display will show OFF to check the remaining time to the next turn on please push the selection buttons the LCD will show the remaining time in hours 5 6 Reset the UPS If any abnormal condition occurs and the item 4 3 can not be executed please push the button for at least 10 sec when all the LCD data disappear then the UPS is reset 5 7 DIP Switch Settings DIP Switch 1 2 3 4 DIP switch setting DIP 4 DIP 2 220V System 110V System 220V 60Hz 100V 50Hz 220V 50Hz 110V 60Hz 2
2. blown Inside the drawer of inlet 3 Dead wall socket Power output is normal UPS UPS is over loaded emits continuous beep LCD shows Overload No power on outlets UPS emits continuous beep LCD shows Overload UPS does not provide expected run time Button on front panel doesn t work To push button for testing under AC mode UPS emits urgent beep 8 beeps per sec and LCD shows Battery replacement UPS can not be turned on UPS has shut down due to overload 1 Excessive loads connected at UPS s outlets 2 Battery is weak and can not provide enough capacity 1 The CPU inside UPS is not running correctly 2 Button damaged Battery is weak and should be replaced 1 Battery polarity wrong 2 UPS fault 16 1 Check the line cord plug 2 Replace fuse 3 Check wall socket with a table lamp Turn off UPS and unplug excessive loads from UPS Unplug excessive loads from UPS press button to reset the buzzer and turn on the UPS again Do not operate the UPS and leave the UPS plugged in for 10 hours Then test it again if UPS still can not provide expected run time battery should be replaced 1 Push the button for 10 seconds to reset the UPS 2 Unplug line cord and all loads from the UPS to let it shut down automatically and call for service Replace batteries 1 Check battery connection 2 Call for service 8 SPECIFICATIONS CAPACIT
3. o z ee men HM oe cE 6 l a 8 5 94n 10 11 49 12 Symbol Indication Description gt Over load The loading exceeds the rating of UPS 2 Load level The higher the loading the more bars will illuminate 3 7 i UPS is loaded When Green Mode is enabled this symbol will display if the loading is over 30W approximately and disappears when it is under 25W approximately Refer to User s Manual 4 3 5 If Green Mode is disabled the symbol will always display N LNF symbol will blink when the UPS is in N back up inverter mode The sine wave symbol will display steadily with blinking battery symbol when the UPS is in testing mode 4 bd an Normal mode 1 The sine wave symbol will display steadily without battery symbol when UPS is in the normal mode Nr Battery mode 2 The sine wave symbol and battery 10 No Symbol Indication Description gt The AVR Auto Voltage Regulator is reducing NT the output voltage of the UPS when the input voltage is too high and the sine wave symbol nn as mentioned in item 4 will also display steadily to indicate that the output is in the normal mode Ar The AVR is increasing the output voltage of the UPS when the input voltage is too low and the sine wave symbol as mentioned in item 4 will display to indicate it s in the normal mode This symbol will show up in the following situations 1 A turn on tum off sche
4. the battery or batteries released electrolyte is harmful to the skin and eyes A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles To prevent an overbalance of this unit with the installation the additional stabilizer are to mount at the bottom side This unit should be installed from service personnel The equipment can be operated by any individuals with no previous experience The socket outlet shall be installed near the equipment and easily accessible With the installation of this equipment it should be prevented that the sum of the leakage current of the UPS an the connected consumer does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the main hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole through the from the outer enclosure accessible battery fuses when maintenance or service work inside the UPS is considered The lead acid battery may cause chemical hazard The battery presents a risk of electric shock and energy hazard Batteries will be disposed by the manufacturer or importer Customers need to send them back with no charge for disposal Electrical hazard th
5. the battery set to be replaced change the batteries inside with the same spec amp number and make it in series connection DWG 4 2 3 Inside view of battery pack when top cover is removed Put back the battery set in the main unit finish the connection with the UPS and proceed the same steps for replacing the other battery set Once the battery replacement has been finished please put back the cable connection to the LCD module and tightly screw on the front panel The warranty will be void if to replace battery without the same spec or number The battery type is 12V 7Ah 6pcs for each pack and 12pcs in total Operation After installation with normal city power the UPS will charge the battery automatically and the battery symbol and battery level will blink every second during charging If AC auto turn on function Ref 5 7 in enabled the UPS will turn on automatically when city power is green If auto turn on is disabled please push the button about one second on the front panel then the UPS will give power to the outlets after a short time of self test 4 3 2 4 3 3 4 3 4 4 4 4 5 4 6 Pushing the button for 4 seconds the UPS will turn off the power on the outlets But the UPS will keep charging if city power is normal During a blackout push the button for entering idle mode Ref Indication Table of 5 3 then push again for one second and the UPS will be turned on and enter into backup mod
6. 2 Germany type x 1 Re settable fuses for output Re settable fuse for input SNMP slot Cooling fan RJ 11 port DIP switch Communication port RS 232 Handles 1 2 1 3 1 4 1 5 1 6 INTRODUCTION Overview The series UPS is an advanced Line Interactive Uninterruptible Power System which produces pure sine wave power to your equipment unlike the traditional off line UPS the series provide very short transference when blackouts happen and zero transference from AC mode to battery mode or from battery mode to AC mode The voltage regulation performance of series is similar to an On line UPS however the series provide efficiency over 98 under normal power condition Two charge modes quick charge and trickle charge are provided to maintain the batteries in the best condition Battery replacement warning The self test function by pushing the button will inform you with an alarm when the batteries are weak and require replacement DIP Switches DIP switches allow you to adjust the UPS for different line voltages and frequencies in different areas It also allows you to enable the green power function to shut down the UPS automatically if the load is less than 25W and then to extend the battery life Communication interface 3sets of communication ports iset of RS 232 SNMP and 2sets RS 232 DB 9 for sensing input voltage output voltage battery capacity output power level and UPS statuses are provid
7. 30V 50Hz 115V 60Hz 240V 50Hz 120V 60Hz DIP 3 for AC Auto turn on when city power returns UP Enable Down Disable DIP 4 for Green Mode setting UP Enable Down Disable P S Program setting active only after the UPS is re started 14 6 COMMUNICATION INTERFACE The UPS provides both computer interfaces smart software RS 232 and dry contact DB 9 by using different software and cable the UPS shows different monitoring function 6 1 The definition and setup for RS 232 is as following Baud Rate 2400 dps Data Length 8 bits Stop Bit 1 bit Parity None 54321 9876 Pin 6 RS 232 data Tx out Pin 7 Common of Pin 6 and Pin 9 Pin 9 RS 232 data Rx In 6 2 The definition and setup for DB9 is as following Pin 2 AC Power Failure Pin 4 Common GND of Pin 2 amp Pin 5 Pin 5 UPS Battery Low Pin 6 Turn off UPS Pin 7 GND of Pin6 The interface with computer is diagramed as above for your reference Use Pin 4 as the common of Pin 2 and Pin 5 Pin 2 and Pin 4 will become close loop from open when the utility fails Pin 5 and Pin 4 will become close loop from open when the battery level is low The UPS will shut down itself when the high level from RS 232 sustained for 3 seconds which is applied between Pin 6 and Pin 7 15 7 TROUBLE SHOOTING Possible Cause Action to Take UPS no reaction while AC is connected 1 Line cord plug is loose 2 Fuse on rear panel
8. UPS AVR Uninterruptible Power System User s Manual Sine Wave Line Interactive Model 5000VA 5 or 8 for AVR TABLE OF CONTENTS FRONT PANEL Page 3 REAR PANEL Page 3 1 INTRODUCTION Page 4 2 MAIN FEATURES Page 5 3 CAUTION Page 5 4 INSTALLATION AND OPERATION Page 6 9 5 INDICATION AND CONTROL Page 10 14 6 COMMUNICATION INTERFACE Page 15 7 TROUBLE SHOOTING Page 16 8 SPECIFICATIONS Page 17 9 IMPORTANT SAFETY INSTRUCTIONS Page 18 19 FRONT PANEL Tower Type Rack Mount Type Introduction of LCD display Load level Mode amp value Battery level AC out es Dad Hs C BATT Min to OFF DO T TIMER POWER ON OFF SELF TEST an G ALARM RESET ot Main control button 2 LCD screen 3 Selection button for mode amp value Rear Panel B1 B2 B3 Tanmo Inlet screw type Outlets Universal sockets 2 x 2 screw terminal x 1 or IEC 5 sockets x 3 or IEC 5 sockets x
9. Y 5000VA 3500W ee Current 220V OUTPUT Volage Frequency Wave Form Current 220V PE TA Level Ind Recharge Time to 90 OPERATION INDICATION LCD symbol shown up cnn Normal city power Sine Wave ee NO beep BE Back up Mode Sine Wave Battery B B B B 2 beeps 4sec Abnormal Freq of City power Sine Wave Battery B B B B 2 beeps 4sec Freq gt 65Hzor lt 47Hz na 4 ENSN to backup mode mm Abnormal V of City power Sine Wave Battery B B B B 2beeps 4sec Voltage gt 122 or lt 80 PANSFEL to backup MODE cnn Abnormal V of City power Sine Wave No beep Voltage lt 122 but gt 105 or Buck or AVR in operation gt 80 but lt 95 Boost D S As S S S Low Battery Alarm Sine V Wave LOW Battery B B B B BB 4beeps sec Battery Fail Alarm Battery replacement BBBBBBBB amp beepssec Over load Alarm Over load B continuously Thermal Alarm High Temp G SR G 32beeps 2sec R silence 2sec CE Shipping Dimensions Separate packing carton for main unit 64x60x40cm amp battery packs 45x18x13cm 2sets and about 6 10 sets per pallet Weight N W G W Kg 70 74 Specifications subject to change without prior notice 17 IMPORTANT SAFETY INSTRUCTIONS When replacing the batteries use the same number and the same type of batteries Do not dispose of batteries in a fire the battery may explode Do not open or mutilate
10. dule has been set using the monitoring software Refer to User s Manual 5 5 and the Readme file or Help function of the monitoring software The Green Mode is enabled and the loading is under 25W approximately The UPS will tum itself off automatically in 30 seconds Refer to 4 4 of User s Manual Thermal alarm The temperature inside the UPS is over 55 If the user does not reduce the load the temperature will continue to rise and the UPS will shut down automatically at 60 Fan is in High This symbol is used only for long back up models and 5000VA model The symbol will display whenever the cooling fan is running in high speed and will disappear at low speed Silence mode The audible alarm has been silenced To reset the alarm in Back up mode push the control button not available during low battery level or abnormal condition 1 In normal operation this symbol indicates a charged battery 2 When the battery charge level is low the word LOW will be added to the symbol 11 1S ey iy Te sea msi et Battery The battery has failed and must be replaced replacement The battery is checked each time the Test Function is executed Battery voltage 1 The higher the battery voltage the more level bars will illuminate 2 When the UPS is charging the battery the battery symbol and the level indicator will blink together Description AC output voltage AC input voltage AC output freque
11. e To turn off the power from UPS please push the button for 4 seconds then UPS s LCD screen will show OFF wait for 5 seconds and UPS will turn off the power automatically In idle mode UPS will turn off the power automatically within 4 seconds during a utility failure while UPS will keep charging the batteries if the utility power is normal Green mode setting When Green Power function is enabled Ref to 5 7 the UPS will turn off the power within 30 seconds after blackout occurs with the power consumption lower than 25W Ring on function When you are connecting the phone line through the UPS The UPS may offer protection against damaging power fluctuations and surges that travel through the phone line The UPS also offers a ring on function when the power is off UPS power will be turned on automatically when a ringing signal exists in the phone line and the UPS will keep power on until the UPS is turned off by button pressing or by the green power function or by RS 232 interface Enable disable silence mode The silence mode can be enabled or disabled only when the UPS is in back up mode or test mode To push the test button for 0 5 second will enable disable the silence mode If UPS is in normal mode UPS will run test mode once you push the test button silence mode can be enabled disabled during test mode 5 INDICATION AND CONTROL 5 1 Indication LCD screen EN ee HHEH pa Min to OFF C TIMER
12. e discharge time is about 5 min 18 German wording Wenn Sie die Batterien austauschen verwenden Sie bitte die gleiche Anzahl und den gleichen Batterietyp Werfen Sie niemals die Batterien in das Feuer die Batterien k nnten explodieren ffnen oder besch digen Sie nicht die Batterien ausfile endes Elektrolyt ist sch dlich f r Haut und Augen Eine Batterie kann eine Gefahz eines elektrischer Schlages und sehr gro er Kurzschlu str me beinhalten Folgenda Vorkehrungen soiiten getroffen warden wenn Sie mit der Battery arbeiten Entfernen Sie Uhren Ring and andere metallische Objekte Verwenden Sie Werkzeug mit isolierten Griffen Um ein Umkippen dieses Ger tes zu verhindern sind mit der Installation dieses Ger tes die zug talichen St tzen an der Unterseite dieses Ger tes anzubringen Dieses Ger t ist durch Elektrofachkr fte zu installieren Bedienung durch jedermann ohne dem Vorkenntnisse Die Steckdose mu nahe dem Ger t angebracht und leicht zug nglich sein Bei der Installation dieses Ger tes ist darauf zu achten da die Summe der Ableitst me der USV und der angeschlossenen Verbraucher den Maximalwert von 3 5mA nicht berschreiten Vorsicht Gefahr durch elektrischen Schlag Auch nach Trennung von der Netzeingangsspannung werde Teile innerhalb der USV von der Batterie gespeist und f hren gef hrliche Spannung Bei Instandhaltungsarbeiten ist daher die Versorgung durch die Bat
13. ed through this port you can remote control the UPS for turning on and off by customized schedule and setting the auto test procedure Extra wide voltage of AVR The AVR range for the model is made as precise as 5 for output with input range 22 or upon request 8 for output with input range 35 Warning for failed battery Real time detection The battery self detect function will run every 20 minutes no need to push the button by user The Battery replacement symbol on LCD panel will show up when battery failed or is in open circuit MAIN FEATURES Pure sine wave output Zero Transference Line Interactive structure Microprocessor based design RS 232 interface for communication Green Power designed with auto on off function Protection for overload short circuit amp over heat CAUTION The UPS is designed to power computer loads and the associated peripheral devices such as monitors modems external H Disk drivers etc To ensure the performance of the UPS Do Not load the UPS with motor or any type of inductive load Connecting the UPS to a two pole three wire grounding mains receptacle Connection with any other type of receptacle may result in a shock hazard and may violate local electrical codes Do not allow water or any foreign object to get inside the UPS And do not put objects containing liquid on or near the unit Keep UPS away from fire or heating sources The standard
14. models are shipped from the factory with fully charged internal batteries however the batteries may lose some energy during delivery and storage To ensure that the UPS will provide the expected run time during a blackout the UPS must be left in charging for at least 5 hours before your first use The batteries are charged automatically by the UPS whenever the UPS is connected with city power No need to turn on the UPS 4 INSTALLATION 18 OPERATION 4 1 Unpacking amp Installation 4 1 1 Inspecting the packing carton for damage that may have occurred while in transit Immediately notify the carrier and place of purchase if any damage is found Retain the package for future use 4 1 2 The packing of the UPS is separated into 3 units main unit weight 39kgs amp 2 units of battery set weight 18kgs of each Each battery set contains 6pcs of 12V battery 4 1 3 To move the units main unit needs 2 3 persons while the battery set can be moved by one for each 4 1 4 The UPS can be used as a rack mount unit or a tower one Please follow the steps to make it as a rack mount unit or a tower one as below 4 1 4 1 Tower type To screw on the rubber pad 6pcs as attached at the bottom side of the unit or put on 4 wheels optional Bottom side with pads or wheels 4 1 4 2 Rack mount type to screw on the handling ears as a regular rack mount unit put it on the rack and fix it Adjust the display panel between tower am
15. ncy DC battery voltage UPS internal temperature The UPS will turn off when the displayed value reaches zero For example if the timer shows 0 5 Min to off the UPS will shut down in 30 seconds Hr to on The UPS will tur on when the displayed value reaches zero For example if the timer shows Min to off The estimated remaining run time in Back up mode The accuracy of the value is influenced by the loading type ambient temperature and battery condition old or new Selection Button for mode amp value All the operation data will be displayed on LCD screen By selecting the required mode upward or downward the related value will be displayed 5 2 Control 5 2 1 Main control button Please refer to point 4 amp 5 4 3 amp 5 3 5 4 5 2 2 Selection Button with symbol of upward downward You may select a required mode and the LCD will show you the value Ref Item 15 of LCD description 12 5 3 Audible alarm During a utility failure or fault operation the UPS emits beep for warning In back up mode the beeping can be silenced by pushing the button However the warning of low battery will still sound for urging user to leave computer without any data loss Basic Indication Table la STATUS ALARM Idle mode Utility Good Utility outage refer to Item 5 5 Normal Utility good Back up mode Back up No load One beep every 4 sec alarm can be silenced Back up Loading Abnormal oa
16. p rack mount types you can make it easily simply by screwing on off the 4 screws around the display panel with 90 turning on the panel 4 1 5 4 1 6 4 2 4 2 1 4 2 2 To install the UPS please fix the main unit first then put on the battery set one by one and finish the connection Ref 4 2 finally make connection for input and output of the UPS To ensure that your computer or equipment will be protected during a utility failure it is important to make sure that the maximum power needed by the equipment is not over the rated capacity of the UPS The over load mark on LCD panel will be lighted up and alarm will beep if the load is over the rated value Meantime if the overload is severe the UPS will shut down immediately for protecting UPS itself Battery Installation Replacement This is a hot swappable designed UPS which means that when you are replacing battery set the UPS doesn t need to be turned off To install or replace batteries please screw off the 4 screws of front panel disconnect the cable connection to the LCD display module then please disconnect and pull out one of the two battery sets and keep the other set in connection so that your equipment can be still protected during the period of time for battery replacement DWG 4 2 2 1 Front view of the unit DWG 4 2 2 2 Inside view when front panel is removed 4 2 3 4 2 4 4 2 5 4 2 6 4 3 4 3 1 Please screw off the top cover of
17. terie an den von au en zug nglichen Sicherungshaltern in beiden Polen zu unterbrechen Die Blei Akkumulatoren K nnen bei unsachgem er Handhabung chemische Gefahren hervorrufen Die Batterie birgt eine Gefahr eines elektrischen Schlages und sehr hoher Kurzschlu stroeme Batterien werden durch den Hersteller oder Importeur entsorgt Dazu muessen die Batterien kostenfrei angeliefert werden Gegahr durch elektrischen Schlag die Entladeit dieser Kondensatoren betr gt 5 min 19