1. UB RO2 User s Manual Copyright SEIKO EPSON CORPORATION 2004 Printed in Japan 2004 01 404861602 Introduction The UB RO2 is an interface board on which is installed an IEEE 802 11b Radio Frequency RF module for EPSON TM printers This manual provides instructions including a simple setup for operators of POS systems in which the UB R02 is installed so that the operators can use the UB RO2 safely and correctly Key to Symbol The symbol in this manual is identified by its level of importance as defined below Read the following carefully before handling the product Q Note Notes have important information and useful tips on the operation of your equipment Features and Functions d 64 128 bit WEP 1 Protocols TCP UDP ICMP IP LP LPR for APD TCP socket port for OPOS 1 Transfer rate up to 11 Mbps depending on operating environment m OPOS APD support Part Names The following view shows the part names of the UB R02 Push button Drawer kick out Power supply connector connector Note This photograph shows the TM T88lll printer with the UB RO2 installed DIP Switches When using this interface board the interface of the TM printer must be selected as parallel with the appropriate settings Set the reset signal for pin 31 to enable if you are using a TM printer that has this setting Refer to the manual for each TM printer for details How to Set Up the UB R02 Prepa
2. www epson pos com Select the product name from the Select any product pull down menu EMC Standards Applied Product Name UB R02 Model Name M195A The following standards are applied only to the interface boards that are so labeled EMC is tested using the EPSON power supplies and TM series printers Europe CE marking North America EMI FCC ICES 003 Class A Oceania EMC AS NZS 3548 CISPR22 Class B WARNING You are cautioned that changes or modifications not expressly approved by Seiko Epson Corporation could void your authority to operate the equipment CE Marking The printer conforms to the following Directives and Norms Directive 89 336 EEC EN 55022 Class B EN 55024 TEC 61000 4 2 TEC 61000 4 3 TEC 61000 4 4 TEC 61000 4 5 TEC 61000 4 6 TEC 61000 4 11 The printers in which this board is installed do not conform to the following Directive 90 384 EEC EN 45501 FCC Compliance Statement For American Users This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are she atta to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipmen
3. onnect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help For body worn operation this CF114100 has been tested and meets the FCC RF exposure guidelines when used with the Universal Scientific Industrial Co Ltd accessories supplied or designated for this product Use of other accessories may not ensure compliance with FCC RF exposure guidelines CANADA This device conforms to IC Low Power License Exempt Radio Communication Devices RSS 210 The information such as Certification No Model Name and Manufacturer Name are described on the surface of the module EUROPE Hereby Universal Scientific Industrial Co Ltd declares that this CF114100 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The UB R02 can be used only in the countries listed below Austria Belgium Germany Luxembourg Netherlands Switzerland France Italy Greece Spain Portugal Denmark Finland Ireland Sweden UK USA Canada Australia and New Zealand All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Seiko Epson Corporation No patent liability is assumed with respect to the use of the information c
4. ontained herein While every precaution has been taken in the preparation of this book Seiko Epson Corporation assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained herein Neither Seiko Epson Corporation nor its affiliates shall be liable to the purchaser of this product or third parties for damages losses costs or expenses incurred by purchaser or third parties as a result of accident misuse or abuse of this product or unauthorized modifications repairs or alterations to this product or excluding the U S failure to strictly comply with Seiko Epson Corporation s operating and maintenance instructions Seiko Epson Corporation shall not be liable against any damages or problems arising from the use of any options or any consumable products other than those designated as Original EPSON Products or EPSON Approved Products by Seiko Epson Corporation EPSON is a registered trademark of Seiko Epson Corporation Windows is a registered trademark of Microsoft Corporation USA General Notice Other product and company names used herein are for identification purposes only and may be trademarks of their respective companies Notice The contents of this manual are subject to change without notice Please contact us for the latest information Printed on Recycled Paper
5. ration Printing a Status Sheet Power on the printer Wait for a few seconds Then hold down the push button on the interface card for more than 3 seconds The printer prints the parameters for the UB R02 You can check all setting values necessary SSID Network mode IP address Subnet mask Gateway address for the network connection Connection Set the setting of the host PC and AP to match the network setting that you have confirmed with the status sheet You can check whether the connection to the printer has been correctly done by inputting the ping command through the command prompt Example Ping 192 168 192 168 Q Note Although the example shows the address 192 168 192 168 use whatever IP address is reported on the status sheet Because the default IP addresses for all the wireless printers are the same you should power on and configure only one printer at a time Resetting the UB R02 to Factory Defaults Hold down the push button on the interface card while turning on printer power and continue to hold it down for 5 seconds This causes all internal settings to return to their factory defaults Setup The TMNetWinConfig version 2 0 or later and the UB RO2 Technical Reference Guide are necessary for setup Obtain them from the appropriate web site below For customers from North America go to the following web site http pos epson com For customers from other countries go to the following web site http
6. t in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FOR CANADIAN USERS This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada RF Module This equipment contains the following wireless module Manufacturer Universal Scientific Industrial Co Ltd Model Name CF114100 Product Name USI WLAN CompactFlash Card Type I USA This device conforms to Part 15 of the FCC rules This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver C