Home

S4 PARNel User Manual CE 0107.book

image

Contents

1. Source Four PARNel CE User Manual Production Dates September 2004 Present Copyright 2008 Electronic Theatre Controls Inc All Rights reserved Product information and specifications subject to change Part Number 7061M1260 06 01 Rev B Released June 2008 Picking 7061M1009 B Table of Contents Declaration of conformity lille 1 Source Four PARNel CE guidelines a na naana aaa 2 Basic assembly 4 2 n pec EE Modena e a a 3 Luminaire information llsseille eee 3 Colour frame holder 0 0060 cece eee 5 Replacing the HPL lamp 00 002eeeeeaee 5 Focus knob positioning 0 0 cee eee 6 Lens identification llle 7 Changing front lens anria e earan k E cee ce ee ne 7 Cleaning glass lens 0 0 0 0 eee 8 Cleaning the reflector 0 0 2 0 cee eee 8 Portable appliance test PAT guidelines 9 ETC Emphasis Expression Insight Imagine Focus Express Unison Obsession Il ETCNet2 EDMX Source Four Revolution Sensor and WYSILink are either registered trademarks or trademarks of Electronic Theatre Controls Inc in the United States and other countries All other trademarks both marked and not marked are the property of their respective owners i Table of Contents English Declaration of conformity gepr fte Sicherheit We Electronic Theatre Controls Europe Ltd dec
2. ck the retaining clip by pushing sideways while gently pushing forward Note Use only colour frames or accessories with 19 cm mounting flange Replacing the HPL lamp HPL lamp Lamp retaining clips Lamp housing Knurled bolt Figure 3 A lamp must be installed before you use the luminaire Note Verify that the HPL lamp you intend to install is suitable for your facility s voltage 115 120 230 and 240 volt HPL lamps are available See HPL lamp table page 4 Operating HPL lamps above their rated voltage reduces lamp life and can cause premature lamp failure WARNING Let the lamp cool before replacing Step 1 Disconnect power to the Source Four PARNel CE before installing the lamp Step 2 Loosen the knurled bolt on the back of the lamp housing disconnect the Earth continuity cable and pull the housing out English Step 3 Holding by the base remove the HPL lamp from its box A CAUTION Use caution when installing or replacing any lamp When installing replacing lamp be sure to point the lamp away from your face and away from others before inserting it firmly into the assembly This may prevent injuries if the lamp should break INCORRECT Ch zz CORRECT Note To avoid premature lamp failure do not touch the lamp glass If you do clean it carefully with isopropyl alcohol and a clean lint free cloth Allow to dry before operation Step 4 Alig
3. comes cracked or badly scratched CAUTION Never operate the luminaire without a lens in place WARNING Unplug the luminaire and allow it to cool down before attempting to change a lens Removing a wave stippled front lens Step 1 Place the luminaire on a flat stable work surface Do Not remove or install lenses with luminaire hanging Step 2 Rotate the focus knob to the full spot position Step 3 Tilt the front of the luminaire down at least 45 See Figure 6 Step 4 Press the spring clip with your finger to release the lens Step 5 Allow the lens to drop forward from under the clip Step 6 When the lens drops remove your finger allowing the lens to slide forward until it rests on the lens catchers See Figure 7 Step 7 Carefully remove the lens Installing a wave stippled front lens Step 1 Position the luminaire with the front of the unit lens side facing you and tilted slightly upward See Figure 8 Step 2 Rotate the focus knob to the full spot position Step 3 Hold the lens by the edge and position it so the convex side faces the rear of the luminaire Note Installing the front lens with the contoured side out will not impair the optics but it will make removing the lens difficult Step 4 From the top of the luminaire slide the lens behind the lens catchers and position it behind the tabs on the bottom of the lens rotator ring English Step 5 Gently push the top of the le
4. e Cleaning the reflector The reflector is located behind the rear fixed position wave clear lens and requires disassembly of the luminaire to access it See the Source Four ParNel Assembly Guide for instructions on luminaire disassembly assembly Source FourPARNel CE User Manual English Portable appliance test PAT guidelines The Portable Appliance Test is a set of tests that must be administered to electrical equipment in the UK and some locations in Europe to ensure safety The tests are typically carried out using a small PAT device The PAT device connects to a power source and then attaches to the product via an electrical outlet and test probes The PAT provides a simple pass or fail result allowing rapid testing of large inventories Source Four CE luminaires include a specific PAT point where the test clip is attached as shown in Figure 10 PAT tests should be performed by a qualified technician Your local regulatory authority has guidelines on the testing frequency PAT connecting point Figure 10 ODE Corporate Headquarters 3031 Pleasant View Road P O Box 620979 Middleton Wisconsin 53562 0979 USA m Tel 608 831 4116 Fax 608 836 1736 London UK Unit 26 28 Victoria Industrial Estate Victoria Road London W3 6UU UK m Tel 44 0 20 8896 1000 m Fax 44 0 20 8896 2000 Rome IT a Via Ennio Quirino Visc
5. lare under sole responsibility that the product A T V Rheiniand Product name Source Four PARNel CE Product type model Source Four PARNel EA Lot n a Batch Serial number n a Item numbers one of each model to which this declaration relates in conformity with the following standards EN60598 1 2000 Luminaires General requirements and tests EN60598 2 17 1990 Specification for luminaires for stage lighting television film and photographic studios outside and indoor equiv BS 4533 102 17 1990 following the provisions of EU LV Directive s 73 23 EEC London United Kingdom Mr Adam Bennette Place of issue Name of authorised person ud n 09 Ae Eo XC Date of issue signature of authorised person Electronic Theatre Controls Europe Ltd Registered office Unit 26 28 Victoria Industrial Estate Grant Thornton House Victoria Road London W3 6UU U K Melton St London NW1 28W England Telephone 44 0 20 896 1000 Registered in England No 3057796 Fax 44 0 20 896 2000 VAT No 6629487 90 English Source Four PARNel CE guidelines The Source Four PARNel CE is intended for professional use only Read the entire User Guide before using equipment WARNING Please note the following safety precautions Do not mount the Source Four PARNel CE on or near a flammable surface Use the Source Four PARNel CE in dry locations only where humidity does not exceed 90 percent The luminaire is fo
6. n the flat sides of the lamp base with the retention brackets on either side of the Socket as shown in Figure 3 Step 5 Push down on the lamp base until the lamp seats firmly When properly installed the top of the lamp s base will be even with he top edges of the retention brackets A CAUTION Improperly installed lamps cause premature lamp failure and socket problems Step 6 Press lamp retaining clip across lamp base to secure Step 7 Reconnect the Earth continuity cable Reinstall the lamp housing by aligning the bolt hole and tightening the knurled bolt Focus knob positioning pem li ien U M Xe 45 field angle REL g Focus knob in Focus knob T flood position screw P d Lo fA 25 field angle iy ae te By Focus knob in H spot position dim Figure 4 To adjust focus knob tension loosen or tighten the focus knob screw See Figure 4 A CAUTION Lens rotation knob does not rotate 360 Do not attempt to exceed limit 6 Source FourPARNel CE User Manual erp English Lens identification Lenses for the Source Four PARNel come in two versions The wave clear lens is in a fixed position in the rear of the luminaire The wave stippled lens is in the rotating ring at the front of the luminaire The wave surfaces face each other WavelStippled Lens WS WavelClear Lens WC Figure 5 Changing front lens Replace lens if it be
7. ns inward until it snaps behind the spring clip Spring clip Retaining clip Retaining clip Lens Spring clip gt SI PRK f ER N A LE Y A Focus knob lt S ocus kno Y ala Tab ens catcher Figure 6 Figure 7 Figure 8 Positioning the wave stippled front lens p Top center notch Step 1 Step 2 di J NG _______ Bottom two center notches Figure 9 There are seven notches cut into the stippled side of the lens Position the lens so the cluster of three notches is on top The center notch of the cluster aligns with the spring clip on the lens retainer ring See Figure 9 The bottom of the lens has a cluster of four notches Place the two center notches behind the tabs at the bottom of the lens rotator ring Cleaning glass lens WARNING Do not use ammonia based or other harsh commercial cleaners Clean lens only as directed Commercially available glass cleaning agents should be avoided as they may contain ammonia other harsh chemical detergents or abrasive agents These cleaners may damage the glass surface and the Anti Reflective coatings Do not immerse or soak the glass in any cleaning solution Replace lenses if they contain visible damage cracks or deep scratches that may impair their effectiveness Remove dust with a blast of oil free air or wipe with a clean lint free cloth Isopropyl alcohol distilled water or a 50 50 mixture of each can be used to clean the glass surfac
8. onti 11 00193 Rome Italy Tel 39 06 32 111 683 Fax 39 06 32 656 990 Holzkirchen DE Ohmstrasse 3 83607 Holzkirchen Germany m Tel 49 80 24 47 00 0 Fax 49 80 24 47 00 3 00 Hong Kong Rm 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong m Tel 852 2799 1220 m Fax 852 2799 9325 Service Americas service etcconnect com m UK service etceurope com m DE techserv hoki etcconnect com w Asia service etcasia com Web www etcconnect com w Copyright 2008 ETC All Rights Reserved m Product information and specifications subject to change 7061M1260 06 01 m Rev B m Released 06 2008
9. ours HPL 375 230 375 230 7 250 3 000 K 1000 hours HPL 750 2240 750 240 19 750 3 200 K 300 hours HPL 750 240X 750 240 15 600 3 050 K 1500 hours HPL 575 240 575 240 14 900 3 050 K 400 hours HPL 575 240X 575 240 11 780 3 050 K 1500 hours HPL 375 240X 375 240 19 750 3 000 K 1000 hours o Note The performance of saturated colours may be less than desirable in any theatrical lighting luminaire especially when equipped with a 750w lamp For best results always use high quality colour media rated for high temperature use ETC s optional Gel Extender part PSF1029 will provide maximum colour media life The use of any gel extender accessory may limit the coverage of any wide angle lens or beam setting A variety of heat shield products is also available from many colour media manufacturers Follow the manufacturer s instructions for the use of these products 4 Source FourPARNel CE User Manual English Colour frame holder Retaining clip in the locked position Figure 2 The colour frame holder is equipped with a spring loaded retaining clip that prevents colour frames and accessories from falling out See Figure 2 WARNING Make sure all colour frame accessories are locked in position with the retaining clip before hanging the Source Four PARNel CE Step 1 Release the retaining clip by pushing it sideways while gently pulling backwards Step 2 Insert the colour frame Step 3 Lo
10. r indoor use only and is not intended for outdoor use For temporary installations mount and support the Source Four PARNel CE only by the primary suspension yoke holes Suspend the luminaire from a hook clamp or a stand mount using a securely tightened steel bolt up to 12 mm flat washer and locking washer In addition to primary suspension attach a safety cable ETC part 7060A1022 or chain to the secondary sus pension point on the Source Four PARNel CE If the external cable is damaged it shall be replaced by ETC or our service agents Always hang the Source Four PARNel CE with the colour frame held securely behind the retaining clip Always replace the lamp if it becomes damaged or thermally deformed Disconnect the unit from power before all cleaning and maintenance The Source Four PARNel CE is suitable for indoor use with a maximum ambient temperature T 45 C Maximum exterior surface temperature T max 242 C A multilingual label sheet is included with this manual Affix the label of the appropriate language over the existing warning label on the extension yoke Do not cover ETC trademark or CE mark The Source Four PARNel CE contains a CE safety screen that covers the lens to prevent injury from broken glass die to lamp failure Do not remove the safety screen Keep the luminaire at least 2 7 meters away from any lit surface Lighted objects at this distance or greater will not exceed 90 C temperature from projected light So
11. urce FourPARNel CE User Manual English Basic assembly Yoke locking knob R Be Gel retaining clip Lamp housing Color frame holder Lens catcher Clear lens Stippled lens a Color frame Safety screen Figure 1 Luminaire information WARNING Please note the following safety warnings before use Do not mount the luminaire on or near combustible surfaces Do not operate the luminaire without a lens installed Always hang the luminaire with the color frame retaining clip in the locked position Wiring and power information A plug of at least 2 5 amp 220 240V rating should be attached to the luminaire s mains lead The wires in the mains lead are 1 55mm each and coloured in accordance with the following code Green and Yellow Earth Blue Neutral m pL Brown Live WARNING This luminaire must be earthed Current rating 240V 2 5 amp maximum Operating frequency 50 60 Hz English HPL lamp table A CAUTION Do not use lamps other than the HPL in Source Four fixtures Use of lamps other than HPL will void your warranty Lamp code Watts Volts Initial Lumen Colour Average rated life temp HPL 750 230 750 230 19 750 3 200 K 300 hours HPL 750 230X 750 230 15 600 3 050 K 1500 hours HPL 575 230 575 230 14 900 3 200 K 400 hours HPL 575 230X 575 230 11 780 3 050 K 1500 h

Download Pdf Manuals