User Manual - Sütron electronic GmbH
Contents
1. cd SmartDeviceProjectOP start SmartDeviceProjectOP exe 4 Save the batch file 5 Upload the file to the operating device with the FTP program again and over write the old version At the next start of the operating device the project is copied automatically and then started 16 SUTRON Extended Configuration Open platform Backup 6 2 Device Backup Restore A backup restore of data for example Project data start up configuration etc in the permanent memory Flash on a USB stick is created as follows 1 Start the cockpit 2 Press the menu option Update Some settings are password protected The default password is 3 Press the Backup area Backup Device 1 Insert a USB stick into the female connector of the operating device 2 Press the button Backup Device The files are copied to the directory Backup on the USB stick Ifthere is already a Backup directory with data on the USB stick the backup is not performed The successful backup will be confirmed with a dialog Restore Backup NOTICE When restoring the backup all data in the flash memory of the operating device will be deleted The process of backup and restore all settings is possible only with identical de vice types 1 Insert a USB stick into the female connector of the operating device 2 Press the Restore Backup button NOTICE Do not interrupt the power supply during the p
2. disk memory CD DVD drive mouse Windows XP Windows Vista Windows 7 Microsoft Visual Studio 2005 2008 Professional or Visual Studio Team Sys tem 2005 2008 SUTRON Open platform PC Configuration 3 PC Configuration A requirement for creating a project in Visual Studio is the S tron SDK for the E Line The SDK must be installed to support the E Line as target platform Install SDK 1 Start the installation file DK7ECS ELINEARMV4I xxxx msi on your PC 2 Perform a complete installation of the SDK S SUTRON l Operating Device Configuration Open platform 4 Operating Device Configuration D Start cockpit at system startup b ES Vv Using desktop icon to start cockpit vs ae FR 4 1 IP Address To enable access to the operating device the following conditions must be filled The operating device is connected with a network cable An ip address is configured or was allocated by the DHCP server Some settings are password protected The default password is Use the cockpit to display or adapt the ip configuration of the operating device To start the cockpit do the following 1 Wait during the startup phase until the following dialog is displayed Figure 4 1 Cockpit startup phase 2 Press the button to start the cockpit before the progress bar is down You can customize the language of the cockpit interface at the language menu item 3 Press the b
3. ee Re RR ee ee ee ee ee 16 6 2 Device Backup Restore ie ee ee ee ee GR RR AA Re ee ee ee ee ee ee ee Re Re de ee 17 N EE OE EE REESE SETE REESE DERE 18 SUTRON Open platform Important Notes 1 Important Notes OPPPP 1 1 Symbols The symbols in this manual are used to draw your attention on notes and dangers This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible in jury or death DANGER This indicates a hazardous situation which if not avoided will result in death or serious injury WARNING This indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION This indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE This symbol together with the signal word NOTE and the accompanying text alert the reader to a situation which may cause damage or malfunction to the device hardware software or surrounding property This symbol and the accompanying text provide the reader with additional infor mation or refer to detailed sources of information 1 2 Safety Notes Read this manual carefully before using the software Keep this manual in a place where it is always accessible to all users The user manual in particular the safety notes must be o
4. Name Properties in the Project menu 2 Select the tab Devices Application Build Deployment Options Build Events EN P Target device Debug DK7ECS ELINEARMV4I ARMY Device sl Resources Output file folder iFlashDrviSmartDeviceProjectOP mm Reference Paths C Deploy the latest version of the NET Compact Framework including Service Packs Signing Authenticode Signing Devices Sign the project output with this certificate Code Analysis Provision certificate to device Figure 5 6 Project properties devices 3 Remove the hook of the check box Deploy the latest version of the Net Compact Framework including service packs 4 Click on the button on line Output file folder Output File Folder Location of output on device Root Folder Subdirectory FlashDrv SmartDeviceProjectOP Output file Folder generated FlashDrv SmartDeviceProjectOP Figure 5 7 Project properties output file folder 13 S SUTRON Open platform Visual Studio 5 Select the entry Root Folder from the list box Location of output on device 6 Enter the device memory and the project name to the field subdirectory for example FlashDrv SmartDeviceProjectOP D With the appropriate paths different memory areas of the operating device can be accessed Some paths are dependent on the product line of the operating device Product line s Memory type Path All USB stick Ha
5. SSS D SUTRON P User Manual Open platform E Line Part Number 80860 850 Version 1 Date 2014 01 27 Valid for SB7ECS OPENPLATL 0007 Open platform Version Date Modifications 1 2014 01 27 First edition This manual including all illustrations contained herein is copyright protected Use of this manual by any third party in departure from the copyright provision is forbidden No part of this manual may be reproduced trans lated or electronically or photographically archived or altered without the express written consent from Sutron electronic GmbH Violations shall be cause for damage liability Sutron electronic reserves the right to make any changes that contribute to technical improvement S SUTRON Open platform Overall Table of Contents 1 Important e E A 1 1 eind ele ET A 1 2 Safety Notas LL Sad EET iian DETS oo NEE AER NE De 4 1 3 intended VR EE ER N EE EE KREE A 14 Target Group 5 2 EIERE 6 2 1 Hardware and Software Reguirements esse ese ee ee ee ee kernen ee ee ee 6 3 EE 7 4 Operating Device e ue e e E 8 4 1 Gel EE EE EE EE eee cree 8 4 2 Connection to Visual Studio 10 5 Visual See EE 11 5 1 Create die SE OE EE ee 11 5 2 Device Settings iii ee AR AR AA ee enke ee ee ee ee nn ee ee ee 12 5 3 Library for Device FUNCTIONS ee ee ee ee ee ee ee ee ee ee ee ee 14 5 4 Debugging Deploying Project 15 6 Extended Configuration OE EE AE ENE OE EE ON 16 6 1 Starting Project Automatically ee
6. bserved by all per sonnel working with the software and the programmed device Observe the accident prevention rules and regulations that apply to the oper ating site Installation and operation must only be carried out by qualified and trained personnel 1 3 Intended Use The software has to be used for programming operating devices exclusively Every other use is not permitted SUTRON Important Notes Open platform 1 4 Target Group All configuration and programming work in connection with the automation sys tem must be performed by trained personnel only e g qualified electricians elec trical engineers The configuration and programming personnel must be familiar with the safety concepts of automation technology Open platform Introduction 2 Introduction This manual describes the configuration of SGtron operating devices with an open platform in use with the development environment of Microsoft Visual Studio 2 1 Hardware and Software Requirements The descriptions in this manual presuppose basis knowledge in handling Win dows as well as programming knowledge which cannot imparted in this manual If you should have any guestions regarding this we refer to the manuals for Win dows or its online help Your computer should at least have the following hardware and software requirements Computer with 1 6 GHz or better 512 MByte main memory RAM or better 100 MByte free hard
7. eneral Form Factors E HTML Designer 18 Office Tools Test Tools Text Templating 18 Windows Forms Designer E Workflow Designer Show devices for platform DK7ECS ELINEARMV41 Devices DK7ECS ELINEARMV41 ARMV7 Device Save As Default device DKZECS ELINEARMVY4I ARMY Device i v Figure 5 3 Device options 2 Select the branch Devices from the Device Tools tree 3 Mark the entry DK7ECS ELINEARMV4I in the Show devices for platform list box 4 Select DK7ECS ELINEARMV4I ARMV7 Device as Default device 5 Click on the button Properties DK ECS ELINEARMV4I ARMV7 Device Properties Default output location on device Program Files Folder Transport MS Connect Transport Bootstrapper ActiveSync Startup Provider Detect when device is disconnected Figure 5 4 Device settings properties A 12 2 SUTRON Open platform Visual Studio 6 Click on the button Configure Configure TCP IP Transport use fixed port number Device IP address Obtain an IP address automatically using ActiveSync Use specific IP address 149 208 160 232 Figure 5 5 Device settings configure TCP IP transport 7 Select the option use specific IP address and enter the IP address of the op erating device 8 Confirm all dialogs with the button OK To define the output folder for the project you still have to carry out the following steps 1 Click on the entry Project
8. nfiguration Open platform Execute project bat 4 2 Connection to Visual Studio The operating device is configured per default for a connection with Visual Studio 2008 To make this connection a batch file project bat is available in the flash memory of the device To make the connection to Visual Studio possible execute the file project bat 1 Briefly press twice on the desktop icon 2 Press the button to start the cockpit before the progress bar is down 3 Press the button Administration Some settings are password protected The default password is 4 Press Administration to activate the area 5 Press the Start Batch File button The batch file is executed 6 Close the Cockpit The debug connection is closed automatically after long inactivity In this case execute the file project bat again to re establish the connection 10 Open platform Visual Studio 5 Visual Studio 5 1 Create Project Open Visual Studio and create a new project as follows 1 Click in the menu File gt New on the entry Project Project types Visual C Windows Web 18 Office Database Reporting Test WCF Workflow 4 Other Languages Other Project Types A Test Projects Figure 5 1 Project type 2 Choose the branch Visual C gt Smart Device in the area Project types The template Smart Device Project should already be selected automatically 3 Click
9. on the button OK Add New Smart Device Project SmartDeviceProjectOP Target platform DK7ECS ELINEARMV4I NET Compact Framework version NET Compact Framework Version 3 5 Templates ki gel mn Sa bei ma Class Library Console Control Library Empty Project A project for creating a NET Application Application Compact Framework 3 5 forms application for Windows CE Platform Download additonal emulator images and smart device SDKs Figure 5 2 Add new Smart Device Project 4 Select the target platform DK7ECS ELINEARMV4I the Compact Frame work Version 3 5 and the template Device Application 5 Click on the button OK Visual studio creates an empty form for the application To adapt the application to the proportions of the target device carry out the fol lowing steps 1 Mark the form Form 11 S SUTRON Open platform Visual Studio 2 Select the entry Size from the property window and type in the width and height of the resolution of your operating device in pixels D Please read the resolution of the display from the product specific user manual 5 2 Device Settings To connect Visual studio with the operating device the following settings must be carried out dl 1 Click on the button Device Options Options E Environment E Performance Tools 18 Projects and Solutions Ip Source Control Text Editor Database Tools Debugging Device Tools G
10. plication Cancel Show me this dialog each time I deploy the application Figure 5 9 Deploy project 2 Click on the button Deploy The project is transferred to the defined place 15 S SUTRON Open platform Extended Configuration 6 Extended Configuration 6 1 Starting Project Automatically After the booting procedure the file starter bat is automatically executed You can use it to start the project automatically The project files should be copied and executed to the RAM memory for this pur pose This accelerates the access and prevents that the project files for exam ple for updates are blocked if these are executed at the moment You can modify the file starter bat as follows 1 Open your FTP program or the Windows Explorer and enter the ip address of the operating device as address Example ftp 149 208 160 232 2 Download the file starter bat to your local file system 3 Extend the batch file with an editor for example Notepad REM Starter bat REM This batch file will automatically start the application upon boot REM 1 Copy data from remanent storage to RAM disc REM remanent storage is either at REM FlashDrv REM 2 Start application executable REM prepare directories for application in RAM disc md SmartDeviceProjectOP REM copy application files from remanent storage to RAM disc copy FlashDrv SmartDeviceProjectOP SmartDeviceProjectOP REM start application at RAM disc
11. rdDisk S Line E Line M Line Internal FlashDrv P Line E Line M Line P Line Memory card StorageCard 7 Click on the button OK 5 3 Library for Device Functions The installed SDK makes a library available for the access to device functions ad ditionally You have to add an reference to the library to use it in Visual Studio 1 Click on the Add Reference button in the project menu 2 Click on the Browse tab 3 Navigate to the following directory C Program files Windows CE Tools SDKs DK7ECS ELINEARMV4I D11 ARMv4I 4 Select the file SuetronDevice dll 5 Click on the OK button S SUTRON Open platform Visual Studio Debugging Deploying 5 4 Debugging Deploying Project The configuration of the operating device and Visual studio makes it possible to debug or deploy your project now To transfer and debug the project to the operating device you proceed as follows 1 Click on the button Start Debugging Deploy SmartDeviceProjectOP Choose where to deploy your application Device Cancel DK7ECS ELINEARMY41 ARMY Device Show me this dialog each time I deploy the application Figure 5 8 Debug project 2 Click on the button Deploy The project is transferred to the defined place and started You can deploy the project also at the configured place 1 Select the menu item Deploy Solution in the Build menu Deploy SmartDeviceProjectOP Choose where to deploy your ap
12. rocess After canceling an pro cess the operating device may not be operational anymore The backup files are copied from the directory Backup to the flash memory of the operating device The successful update will be confirmed with a dialog 3 Restart the operating device 17 A Index B Bles Ko RE OE lades nes 17 E Extended configuration ccccceeeeeeeeeeeeeeeeees 16 H Hardware requirements siese esse ee ee ee ee ee ee 6 Important notes Ee RA Re Ee ee ee ee ee A Intended PA klerk EEN A IP address TTT 8 O Operating device 8 27 q 2 CN 8 S Salely NOS RE OE EE EE HE A Software requirements see ee ee ee ee RR 6 T Target group iese ee ee ee ee AA ee ee kann ee ee 5 V EE Bate OE OE EN 11 Create project ee ek ee AR ee ee 11 Debug project ee Re de 15 Deploy project ee ee ee ee ee ee ee 15 Device settings se Ee ee 12 SUTRON 18
13. utton Language Selection 4 Select the desired language 5 Confirm your selection with the green check You can start the cockpit via the desktop icon at already started operating devices with active desktop 1 Briefly press twice on the desktop icon 2 Press the button to start the cockpit before the progress bar is down You can customize the language of the cockpit interface at the language menu item 3 Press the button Language Selection Open platform Operating Device Configuration 4 Select the desired language J 5 Confirm your selection with the green check Calling network set 1 Press the Network button ungs Following information is displayed IP address Subnet mask Gateway Physical address MAC Assign IP manually If no DHCP server is present or the IP address should be assigned manually pro ceed as follows 1 Select the option use static IP 2 Assign an ip address subnet mask and gateway for the operating device J 3 Confirm your selection with the green check Assign IP automatically With an existing DHCP server the IP address can be assigned automatically 1 Selectthe option Use dynamic IP DHCP J 2 Confirm your selection with the green check 3 Press the Network button and read the assigned IP address D Please see further documentation to the configuration and administration from the device specific user manual D SUTRON Operating Device Co