1. MANUAL amp AUTOMIATED STEP TRANSFORMIER INA 6501 6502 USER MANUAL 1 262 COMPLIANCE TEST SOLUTIONS C C Advanced Test Solutions for EMC MANUAL amp AUTOMIATED STEP TRANSFORMIER INA 6501 6502 USER MANUAL 1 262 CONTENTS 1 Man ual step transformer INA 6501 1 1 Circuit diagram INA 6501 1 2 Technical specifications INA 6501 1 2 1 Parts description 1 3 Installation 2 Automated step transformer INA 6502 2 1 Circuit diagram INA 6502 2 2 Tech 2 2 1 Parts description 2 3 Insta nical specifications INA 6502 lation 3 Addresses 1 MANUAL STEP TRANSFORMER INA 6501 Ml The manual step transformer type INA 6501 is a standard accessory for the Teseq NSG 3000 instrumentation series It provides a convenient means for reducing the incoming supply voltage by pre set amounts It is required for power quality testing PQT and is fully compliant with the latest revision of IEC 61000 4 11 Itis fitted with carrying handles as part of its overall excellent ergonomic design which allows easy handling Further the unit may be used in any of three operat ing positions laying or standing on a workbench For more permanent applica tions it can be even wall mounted Care has to be taken in case of use in standing posi EE tion as the stability is limited The cabling connecting INA 6501 to mains and NSG presents a risk of being unvoluntarly caught by the users which coul
2. 4 steps 0 4096 70 8096 x 596 less than 596 less than 596 less than 596 less than 596 16 Arms at 10096 output 20 Arms at 8096 output for 5 s 23 Arms at 7096 output for 3 s 40 Arms at 4096 output for 3 s User interface or WIN 3000 software Manual amp automated step transformer INA 6501 INA 6502 EUT power ON OFF function Fuse Connectors Possible extensions Own supply Dimensions Weight Cable length to NSG 3000 Input cable Control cable 2 2 1 Parts description Part designation Mains supply in socket EUT power in switch 16 AT fuse EUT power in plug EUT power out cable Front panel switch with ON indicator 11 16 A Slow blow Harting type HAN3A compatible with NSG 3000 safe linking concept Interlock connection to door switch Selectable 100 110 V 220 240 V 15 VA LX W XH 460 x 200 x 160 mm 18 1 x 79 x 6 3 15 kg 33 1 5 approx 2m 79 NSG 3000 standard cable to be used 2m 25 way sub D twisted pair shielded included in delivery Function For instrument supply includes plug voltage selector 110 V 230 VAC on off switch and fuse Switches the EUT power supply on off Protects the EUT power supply line For feeding of the EUT power use NSG supplied cable and connect it to power source mains Connect this cable to the EUT supply input port of the NSG TASEO Advanced Test Solutions for EMC 12 Part designation Plug X3 Plug X2 Plug X1 Power LED
3. green ERROR LED off ERROR LED blinking ERROR LED on 2 3 Installation Function Remote TEST and EUT power off with shorting plug Allows to conect external door switch or equivalent Interrupts the 24 V supply of the circuit breaker contactor which switches EUT supply on off The information will be transmitted to NSG 3000 master controller which will stop the test NSG 3000 system interface out to be terminated by interlock plug or linked to another accessory to X1 plug NSG 3000 system interface in to be connected to master controller or to another accessory to X2 plug Shows if instrument is powered up No problem acessory is ready to run Problem which may be solved by user intervention Expl Interlock is activated Problem which needs module repair please contact your nearest Teseq customer support center or sales reprsentative tion and interconnection d The equipment should be switched off during installa Manual amp automated step transformer INA 6501 INA 6502 EUT power On Off switch 16 AT fuse 13 Mains power switch E RES AAT 16 AT Mains power LED inqications Power ON Termination plug System cable to to NSG or CDN our EUT power in connection i EUT power out to NSG or CDN m Verify the setting of input voltage selector and adjust it to the right mains voltage value if required Connect instrument power from th
4. d cause the INA 6501 to fall down The few control elements are readily accessible on the front panel An EUT power on off switch with a power on indicator and a well proportioned rotary Switch to select the required voltage ensure easy and intuitive operation The unit has been designed for use in rugged industrial environments Professional quality connectors ensure user safety additional system protection is provided by a 16 A fuse located in the front panel Thanks to the provision of an 8096 voltage position and to the large overcurrent capabilities the step transformer is fully compliant with the latest requirements called for in IEC 61000 4 11 standard TASEO Advanced Test Solutions for EMC 1 1 Circuit diagram INA 6501 Input Output Harting cable with socket INA 6501 Harting Step transformer connector UP e 16 e b o r UN 1 I 1 I 13 BEI pe War I I N x 2 N 1 1 l 1 pr 1 2 Technical specifications INA 6501 Input voltage UIN Output voltage UVAR Accuracy Voltage change with load 10096 output O to 16 A 80 output O to 20A 7096 output 0 to 23 A 4096 output O to 40A Output current capability at 230 V input voltage Voltage selection EUT power on off function Fuse Connectors Up to 250 VAC 50 60 Hz not suited for DC voltages 4 steps 0 4096 70 8096 of UIN 5 less than 5 less than 5 less than 5 less than 5 16 Arms at 100 o
5. e mains Remove 25 way Sub D plug at rear of NSG or CDN Connect this connector to X2 of INA 6502 Connect master controller 25 way output to INA 6502 X1 plug using system interface cable delivered with INA 6502 Connect INA 6502 EUT power out to EUT power input Connect INA 6502 EUT power in to mains using EUT power in cable delivered with NSG or CDN 5 earth leakage currents of up to 4 A can occur in the EUT power supply network The test system must therefore be correctly earthed and be powered from a supply that is not protected by a residual current detector RCD m Because of the capacitors in the internal coupler of CDN BW Switch on INA 6502 first Switch on NSG CDN mainframe Switch on EUT power red switch when power for the EUT is required TASEO Advanced Test Solutions for EMC Manufacturer Teseq AG 4542 Luterbach Switzerland T 41 32 681 40 40 F 41 32 681 40 48 chsales teseq ametek com China Commercial Enterprise Shanghai Co Ltd Beijing Branch T 86 10 8526 2111 86 10 8526 2141 chinasales teseq com France AMETEK SAS T 33 1 30 68 89 00 F 33 1 30 68 89 99 info france O ametek com Germany Teseq GmbH T 49 30 5659 8835 F 49 30 5659 8834 deinfo teseq Oametek com Japan AMETEK Co Ltd Nagoya Office T 81 52 709 5501 F 81 52 709 5502 cts japan sales ametek co jp Singapore AMETEK Singapore Pte Ltd C o Teseq P
6. hat is not protected by a residual current detector RCD m Turn on the EUT power in switch of your INA 6501 red switch when power for the EUT is required m Turn on the NSG 3000 generator m Selectthe required variable voltage using the rotary switch on the INA 6501 Manual amp automated step transformer INA 6501 INA 6502 2 AUTOMATED STEP TRANSFORMER 9 INA 6502 E The automated step transformer type INA 6502 is a standard accessory for the Teseq NSG 3000 instrumentation series It provides a convenient means of reducing the incoming supply voltage by pre set amounts It is required for power quality testing PQT and is fully compliant with the latest revision of IEC 61000 4 11 Its control is fully automatic driven from the NSG 3000 master controller using the touch screen interface or the WIN 3000 remote control software Once detected the functions offered by the INA 6502 are available in the interface or software So the settings O 4096 70 8096 will appear as well as the possibility to switch the EUT power ON OFF The INA 6502 is fitted with carrying handles as part of its overall excellent ergonomic design which allows easy handling Further the unit may be used in any of three operating positions laying or standing on a workbench For more permanent applications it can be even wall mounted The unit has been designed for use in rugged industrial environments High quality connectors ensure user safety add
7. itional system protection is provided by a 16 A fuse located in the top panel Thanks to the provision of an 8096 voltage position and to the large over current capabilities the step transformer is fully compliant with the latest requirements called for in IEC 61000 4 11 standard mechanisms it is strongly recommended to power on first the INA 6502 accessory and then the NSG main frame For proper operation of the plug and play detection TASEO Advanced Test Solutions for EMC 10 2 1 Circuit diagram INA 6502 Circuit Breaker Option CIB EUTPOWerON OFE A 4 vin pus NEM E 16 A Uvar gur NC Z 1 q bR Ih oio pod Power 2 u ot N A L NU E N OUT 0 40 70 80 EUT Power jo ON OFF ij Supply mg Interface Controller i Remote Test EUT Plug XI System cable IN Plug X2 System cable OUT Power OFF 25 Way Sub D Male 25 Way Sub D Female Connection to NSG Termination with MaterController via Interlock plug System Interface cable 2 2 Technical specifications INA 6502 Input voltage Output voltage Accuracy voltage change with load 100 output O to 16 A 80 output 0 to 20 A 70 output 0 to 23 A 4096 output O to 40A Output current capability at 230 V input voltage Voltage selection Oto 250 VAC not suited for DC voltages
8. te Ltd T 65 6484 2388 F 65 6481 6588 singaporesales To find your local partner within Teseq s global network please go to www teseq com Switzerland Teseq AG T 41 41 32 681 40 40 32 681 40 48 chsales teseq ametek com Taiwan Teseq Taiwan Ltd T 4 886 2 2917 8080 F 886 2 2917 2626 taiwansales teseq com UK Teseq Ltd T 44 F 44 845 074 0660 845 074 0656 uksales Q teseq com USA Teseq Inc 1 732 417 0501 1 732 417 0511 Toll free 1 888 417 0501 usasa es cts ametek com May 2015 Teseq Specifi notice Comp cations subjectto change without Teseq a unit of AMETEK iance Test Solutions is an ISO registered company Its products are design ed and manufactured under the strict quality and environmental require ments of the ISO 9001 This document has been carefully checked However Teseq does not assume any liability for errors or inaccuracies
9. utput 20 Arms at 80 output for 5 s 23 Arms at 70 output for 3 s 40 Arms at 4096 output for 3 s Front panel rotary switch Front panel switch with on indicator 16 A Slow blow Harting type HAN3A compatible with NSG 3000 safe linking concept Manual amp automated step transformer INA 6501 INA 6502 Dimensions L x W x H 360 x 180 x 150 mm 14 2 x 71 x 5 9 Weight 12 kg 26 5 165 approx Cable length to NSG 2 ig 7 9 Input cable NSG 3000 standard cable to be used 1 2 1 Parts description Part designation Function EUT power in switch Switches on off the EUT power supply 16 AT fuse Protects the EUT power supply line EUT power in plug This is where the EUT power needs to be applied use NSG 3000 supplied cable and conect it to power source mains EUT power out cable Connect this cable to the EUT supply input port of NSG 3000 Red selector To switch variable voltage to 0 or 4096 or 70 or 8096 of Uin 1 3 Installation The equipment should be switched off during installa tion and interconnection B Connect INA 6501 EUT power out to NSG EUT power input Connect INA 6501 EUT power in to mains using EUT power in cable delivered with NSG TASEO Advanced Test Solutions for EMC Because of the capacitors in the internal coupler of the RI CDN earth leakage currents of up to 4 A can occur in the EUT power supply network The test system must therefore be correctly earthed and be powered from a supply t