Home

User Manual - ads-tec

image

Contents

1. Description Power Button can be used to turn the YMT6 on and off Secure Mode The ON OFF pushbutton only switches the device on The switch off function is disabled Fin Austaster Konfiguration Eg Konfiguration Momentane Einstellung Iccherer Modus Normaler Modus Beschreibung Sicherer Modus Der Ein Austaster kann nur zum Einschalten verwendet werden Note If the secure mode is used the device can only be shut down by the software ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e itec OPC6115 6315 39 9 1 6 Exemplary RFID Application The exemplary RFID application was developed in order to test the function of the RFID reader fill ads tec RFID sample application COM Port COM2 Scanning For RFID reader No RFID reader Found Select COM port COM2 selected IPlease hold the transponder near the marked area Note gt In the Interfaces section of the manual you can find more information about the topic of RFIDs 9 1 7 Softkeyboard Here you can configure the soft keyboard application A large variety of settings like layout or commands can individually be adapted sy Softkeyboard General Layout Keys amp Macro Information Softkeyboard keyboard language m Colors Font amp Shade n Keys Auto detect language Background Keys Background Sequences r Lock keys r Start up and close iw Ctrl Esc Ctrl
2. OPC6115 6315 20 p Abb 5 Depending on the device equipment version an operating system Windows CE net Windows XP embedded or Windows XP Prof and a soft keyboard are already installed ex factory The keys on the front panel are occupied with the following functions by a specific driver in the soft keyboard 00 o0 eo ads tec GmbH Heinrich Hertz Str 1 e 72622 N rtingen In the BIOS setup the button acts like the Enter key on a keyboard In the BIOS setup the key behaves like ESC on a keyboard Press this button when booting the pop up menu opens In the BIOS setup the button acts like the on button on the top of a keyboard In the BIOS setup the key behaves like the down key on a keyboard SHIFT key for the second keyboard level The key must be pressed simultaneously with the desired function key In the BIOS setup the key to behave like the left button on a keyboard In the BIOS setup the key to how the right button acts on a keyboard With this combination switch them on without power button Power ON OPC6115 6315 21 6 2 Softkeyboard If an operating system is installed ex works the soft keyboard is also preinstalled If the operating system is delivered separately with the device the soft keyboard must also be installed on site By using the soft keyboard data can be entered via the touch screen like with an external keyboard EBD SUBBHBBBDBSDREE Su agno DO
3. OPC6115 6315 7 6 PS 2 Interface A keyboard can directly be operated by using the PS 2 socket connector Pin Number Signal Name Keyboard Data 1 2 Note oince the timing of the integrated controller is specifically set up for cherry keyboards keyboards of this manufacturer should preferably be used Mouse Data GND 45V Keyboard Clock Mouse Clock 27 If the soft keyboard is actively displayed on the monitor the use of the external keyboard for control purposes is limited The keyboard must be connected before switching the device on because the keyboard interface is initialised in the process of booting If the keyboard is plugged in while the device is running without having had the keyboard connected while booting it will not be functional 7 7 Network Connection RJ45 If the drivers required for functioning are installed on the device the control system may be integrated in an Ethernet network supporting the 10 100 1000Mbit standard by using the Ethernet 10 100 1000BaseT network connector Specifications of this network topology must be observed in this case You can install the drivers required for functioning from the enclosed service CD should they not be installed on the device Pin Number Pin Number Signa Name 7 Signal Name 1 2 CO COIN OO oO gt ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen TX TX RX NC NC RX NC NC OP
4. e This device meets the test requirements for granting the CE sign according to the European test standards EN 61000 6 4 and EN 61000 6 2 e This device complies with the test requirements in accordance with EN 60950 VDE0805 IEC950 Safety of Information Technology Equipment e he device meets the EN 60068 2 6 test requirements sinus excitation e This device meets the EN 60068 2 27 test requirements shock resistance test manufacturer and may be viewed on request All connected components as well as cable connections must also meet these requirements for compliance with the EMC legislation For this reason screened bus and LAN cables including screened connectors must be used Note A respective conformity declaration for the authority in charge is available at the and installed according to the instructions in this user manual Note By using the CE conformity declaration in this document you can find detailed information about the standards applicable to this device Warning This is equipment of class A This unit might cause radio interferences in living areas in this case the operator might be obliged to take suitable protective measures at the operator s expense 1 8 Equipment Versions The system is available in two equipment versions Platform including a Flash SSD Platform without any rotating mass storage medium hard disc etc and with an embedded operating system Windows CE 6 0 XP embedded for s
5. Activate by mouse not available iY Cti Alt Del Alt Switch autologon available Y v Alt F4 Altar 7 Alt Tab Softkeyboard position in top of all other windows v Alt Esc Unlock when closing nat activated Y Restore Defaults Cancel Apply All changes must be confirmed by pushing the Save button ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e itec OPC6115 6315 40 9 1 8 Screen Mob The Screen Mob application was developed in order to disable the touch screen of the device for a certain period of time This function can be used for cleaning the touch screen Touch screen disabled Remaining time 50s 9 1 9 Softkeyboard The soft keyboard must be installed from the enclosed service CD in order to ensure usability of the 5 keys except for the VMT series where you have 6 keys underneath the monitor The installation has to be carried out as described below e Plug in connector of external drive at the device e Switch on PC insert driver CD into drive after booting e Start installer from the service CD e Follow on screen instructions install the driver select the language and confirm the restart of the computer Note You can make further changes to the basic settings of the soft keyboard if required More information about this topic you ll find in the Readme file in the installation folder for the soft keyboard ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e
6. USB interface to which an external drive can be connected In this case you d have to ensure that the used device is suitable for industrial environments Warning Connecting or disconnecting external drives during operation is not admissible since it cannot be excluded that the drive might be in use while connecting or disconnecting it Data loss might result in the event of non compliance ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 32 9 Software Driver Installation The device will be delivered with a pre installed Windows Linux operating system depending on what the customer wants The drivers required for this are already installed and the operating system will be enabled by entering the licence information Should an initial installation be required please follow the following steps With a newer operating system like Windows XP the network card and graphics card will properly be recognised during the initial installation so that only the touch screen driver and the soft keyboard must be installed separately Note If the hard drive was formatted the operating system can be reinstalled by using one of the existing interfaces An external keyboard is required for installation Installation of the Operating System The device does not have any integrated CD drive The installation of the operating system can therefore only be carried out by using the USB interface Procedure
7. touch screen monitor can be started and the crosses appearing in a succession on the monitor have to be pushed for calibration If the cursor position perfectly matches the touch point of your finger you can exit this control menu by pushing OK ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 34 9 1 Configuration Center Configuration The start page of the Configuration Center provides you with an overview of which ads tec applications are installed on the device Additionally you can start any of these applications from the Configuration Center by double clicking on it i Configuration Center Ul Configuration E e gt Automatic brightness ComInput Enhanced Write Ignition Key control Configuration Filter Configuration e EL zm USB Lock Power Button ads tec RFID sample Softkeyboard Configuration application J LA Screen Mob Touch Recovery Wireless Configuration Information For configuration please double click an application Information In the Information section device specific data like the device type the firmware version and the serial number are listed The information you ll find here must be indicated whenever you need to contact the support department Configuration Center t Konfiguration Ger tetyp YMT6 Seriennummer cc Board Revision 03194 C 00 DYG Artikelnummer VMT6015 065 44 44 00 Firmware Version 0 53 BIOS Versio
8. C6115 6315 28 Note PXE booting is only possible by using the LAN1 port Note The device has two separately integrated network controllers of the Realtek RTL 8111c Family PCle Gigabit Ethernet type 7 8 Serial COM Interface RS232 The serial interface is used for digital data transmission The RS232 interface can be connected by using a commercially available 9 pin SUB D cable Note Pin 9 of the serial interface connector can be used for additional switching of a 5V power supply e g for operating a serial barcode scanner The COM 5V switch in the service slot of the device must be put in the ON position in order to use this function A subsequent restart of the computer might be required in order to properly activate this function Pin Number Signal Name 1 DCD RxD OQ AA TxD DTR GND DSR RTS CTS RI oder 5V DC max 1 A O O NI oO oO BI wy pm Note This interface is not electrically isolated ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 29 7 9 DVI Interface The DVI Interface is used to transfer analog and digital video signals A DVI I Cable is required to connect a digital display to the device It is also possible to connect a VGA display by using a suitable DVI VGA adapter Note The DVI Interface is a Single Link Interface The DVI Interface wille be activated only in operating system mode Pin Number Signal Name 1 TM
9. DS Data2 T2 TS Te Ts Te 7 2 TMDS Data2 Firmi d TMDS Data2 4 Shield 4 N C D N C 6 DDC Clock SCL r DDC Data SDA 8 Analog vertical sync 9 TMDS Data1 10 TMDS Data1 11 TMDS Data1 3 Shield 12 N C 13 N C 14 5V Power 15 Ground for 5V 16 Hot Plug Detect 17 TMDS DataO 18 TMDS Data0 19 TMDS Data0 5 Shield 20 N C 21 N C 22 TMDS Clock Shield 23 TMDS Clock 24 TMDS Clock C1 Analog Red C2 Analog Green C3 Analog Blue C4 Analog Horizontal Sync Analog GND Return analog R G B ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 30 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 31 8 Drives The storage medium is selected according to the customer requirements The following options are available for storage Flash SSD A Flash SSD with a storage capacity of at least 1GB is used Its capacity depends on the desired operating system and the additional programmes to be installed Hard disk A 2 5 hard disk with at least 40 GB UDMA is used On delivery the hard disk is formatted in NTFS format default for Windows XP Note Recommendation for the choice of storage medium with a basic installation SSD Flash memory Windows CE 6 0 Windows XP embedded Hard disk Windows XP Professional Externe Laufwerke By default no drive for removable media CD floppy disk is integrated in the device Instead the system provides a
10. MC Under the embedded operating system interfaces must explicitly be enabled and required drivers must be installed in order to be able to use them 5 1 Available Interfaces Note If the case is connected with earth potential at the provided PE contact e g by connecting the PE contact with the device plug the electrical insulation is no longer given This also applies if the device is installed by using a metal retainer clip If you want to have the device electrically insulated from the power supply you have to use a method of installation that ensures appropriate insulation ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen acis tec OPC6115 6315 18 5 2 Cable installation The interfaces as well as power supply plugs for the device are accommodated in the device service slot 5 3 Order of Steps during Commissioning With 24V DC devices Connect the power supply cable with the terminals by using cable end sleeves Connect cable for serial parallel data transmission and fasten the screws between the connector plug and socket Plug in all other required cables and protect from accidental disconnection 5 4 Check for operational Readiness Check the device for any hidden damage potentially caused by improper transport operating or storage conditions or by improper use or handling e g smoke development from the device etc If any damage is detected the device must be put out of service immediately a
11. OR Abb 6 How to operate the soft keyboard from version 3 11 Activate and deactivate the soft keyboard for letter character input using the touch screen Switches numeric keys on and off ur only if numeric keys are visible gt gt Switching between different representations Alphanumeric keys gt Numeric keys gt Function key bar Soft keyboard representation zoom in Soft keyboard representation zoom out Note If a function is to be activated which requires pressing two keys at the same time e g Alt F4 these keys have to be pushed one after another at the soft keyboard and the special keys Shift Alt and Ctrl must always be pushed first Due to differences in programming of a large variety of software we cannot ensure that the soft keyboard works properly with all software programmes When deactivating the soft keyboard the previously active state alphanumeric numeric keys or function keys will be stored and will be displayed when re activating the keyboard ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Ye itec OPC6115 6315 22 6 3 TouchScreen The control system is equipped with a touch screen monitor The touch screen monitor is internally connected with the USB interface The driver software required for using the touch screen is integrated in the corresponding operating system or can alternatively be installed from the enclosed service CD 6 4 Status Indicator
12. Version 2 0 User Manual Industrial IT OPC6115 6315 1 Index 1 Remarks 3 1 1 Relevant Documentation for this device 3 1 2 Used Symbol Explanation 3 1 3 Data Figures Modifications 3 1 4 Trademarks 4 1 5 Copyright 4 1 6 Environmental Conditions 5 1 7 Standards 6 1 8 Equipment Versions 6 1 9 Scope of Delivery 7 2 Notes on Operation amp Safety 8 2 1 Operation Location 8 2 2 Damage Caused By Improper Use 9 2 3 Warranty Repair 9 2 4 Treatment and Disposal of Lithium Batteries 9 2 5 Notes on Safety 9 3 Mounting 10 3 1 Mounting Options 10 3 2 External Device Dimensions OPC6115 11 3 3 External Device Dimensions OPC6315 13 3 4 Mounting procedure 15 4 Add On Card Installation 16 4 1 Pre installation notes 16 4 2 Notes on configuring the add on card PnP 16 4 3 Installing add on cards 16 5 Commissioning 17 5 1 Available Interfaces 17 5 2 Cable installation 18 5 3 Order of Steps during Commissioning 18 5 4 Check for operational Readiness 18 6 Operation 19 6 1 Front Control Keys 19 6 2 Softkeyboard 21 6 3 TouchScreen 22 6 4 Status Indicators 22 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 2 7 Interfaces 23 7 1 Interface configuration 23 7 2 24V DC Power Supply 23 7 3 115 230V AC Power supply 24 7 4 Speakers 25 7 5 USB Interface 26 7 6 PS 2 Interface 27 7 7 Network Connection RJ45 27 7 8 Serial COM Interface RS232 28 7 9 DVI Interface 29 8 Drives 31 9 Software Driver Installatio
13. ads tec GmbH Heinrich Hertz Str 1 e 72622 N rtingen e itec OPC6115 6315 37 9 1 4 USB Lock Function The USB lock function enables you to lock the USB ports if required and to avoid access by unauthorised people Feedback In the Messaging section you can set up whether a message should be output in the event that a USB port is locked or not Additionally the locking process can be logged in the event log Password Protection In order to avoid any unauthorised access to the USB Lock programme the settings made can be provided with password protection In this case the settings can only be modified if the password was entered correctly USB Ports The desired USB ports can individually be locked by using the Lock button D USB Lock Feedback Show message when usb device was blocked C Write message to event log when usb device was blocked Password protection Activate password protection For the current settings LISB Ports sh USB port rear outer a USB port rear inner USB port front All changes must be confirmed with the Save button ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e itec OPC6115 6315 38 9 1 5 On Off Button Configuration The ON OFF pushbutton configuration allows to change the behaviour of the ON OFF pushbutton Regular Mode The ON OFF pushbutton switched the device on and off Power Button Configuration Configuration Current setting mm Mode
14. case is connected with earth potential at the provided PE contact e g by connecting the PE contact with the device plug the electrical insulation is no longer given This also applies if the device is installed by using a metal retainer clip If you want to have the device electrically insulated from the power supply you have to use a method of installation that ensures appropriate insulation ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 24 How to proceed if a PE system is used You must adhere to the following figure in order to ensure a correct installation of the PE system PE Aufbau PE mounting Linsenschraube M4x8 verz DIN7985 lens head screw M4x8 verz DIN7985 Z Scheibe 4 3mm Form A DIN 6797 lock washer 4 3mm Form A DIN 6797 U Scheibe B 4 3 M4 verz DIN 125 U washer B 4 3 M4 verz DIN 125 PE Kontakt PE contact U Scheibe B 4 3 M4 verz DIN 125 U washer B 4 3 M4 verz DIN 125 Z Scheibe 4 3mm Form A DIN 6797 lock washer 4 3mm Form A DIN 6797 7 3 115 230V AC Power supply The power supply is via a mains plug connection fed For the connection of the device should be used the attached cable UF ese ur Technische Daten des Netzteils e Input Max 130 Watt Input current 100 240 VAC current consumption 1 2A 115V 0 6A 230V Max Input current 30A 115 60A 230V Note The typical power consumption of this device is indicated in t
15. control can seamlessly be changed between day and night mode by using a slide control The closer the slider is to the day mode position the darker the ambient light must be before the display brightness is changed to night mode And vice versa the closer the slider is put to the night mode position the brighter the ambient light must be before the display brightness is increased to the value set up for the day mode In order to save the changes you ll have to push either Save or OK ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Ye itec OPC6115 6315 36 9 1 2 COM Input Configuration COM input configuration allows the application to verify the correct RFID function By activation of COM2 the data is send automatically to an active application that uses the COM2 port forwarded Note Unnecessary applications that use the COM2 port must be stopped before running the COM input configuration Because of different programming data on various editors like Notepad or Word are represented differently C aktivieren 9 1 3 Ignition The ignition application allows the control of the VMT6 device ignition function If the status is set to Enabled the device is switched off after expiry of the preset period of time Ignition Key Locking Status Inaktiv HerunterFahren nach 05 Min 00 Sek Textanzeige auf dem Sperrbildschirm Das Ger t ist gesperrt Zeit bis zum Herunterfahren
16. duce electrostatic charge by implementing the appropriate measures see above remove the add on card from the packaging place it in the slot and bolt it to the card mount Each ISA card should be fastened in the matching slot with a clamp to prevent the card from falling out Reconnect the grounding conductor if it has been removed and replace the cover while paying attention to the side clips as the case may be Tighten all of the screws on the cover again ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 17 5 Commissioning The power supply connection and interfaces of this device are installed underneath a protective cover This cover has to be removed in order to connect the power supply lead and the interface cables All supply leads and all required data leads have to be connected before commissioning All supply leads and all required data leads have to be connected before commissioning Warning The device must be switched off before connecting or disconnecting any cables in order to prevent damage to the electronics The device may only be switched on after acclimatising to the ambient temperature in order to avoid condensate accumulation Make sure to meet the permissible voltage requirements for this device After switching off and before switching on you must wait for at least 5 seconds Note The screen of a data cable must always be connected with the connector housing E
17. e companies these devices might be configured in customer specific ways Should any questions arise with respect to these specific configurations and software installations they can only be answered by the system manufacturer For devices not directly purchased from ads tec we don t deliver any support The support is delivered by our associate companies in these cases 11 1 ads tec Support The ads tec support team is available for phone calls from direct clients from Monday to Friday from 8 30 AM to 5 00 PM by using the following phone number Phone 49 0 7022 2522 202 Fax 49 0 7022 2522 2602 Email support ads tec de 11 2 Company adress ads tec GmbH Heinrich Hertz Str 1 D 72622 Nurtingen Germany Phone 49 0 7022 2522 0 Fax 49 0 7022 2522 400 Email mailbox ads tec de Home page www ads tec de ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec
18. ever be exceeded Devices including a data drive must only perpendicularly be integrated Any deviation must be agreed with ads tec The IP65 protection class is only achieved after correct installation If the device is delivered with a CD DVD ROM drive sufficient space approx 130mm must be provided on the left hand side if viewing the drive from the front in order to allow proper opening of the drive Note When selecting the enclosure for integration the power dissipation total of the system including that of all integrated PCBs must be taken into account The enclosure must be calculated in such a way that the maximum environmental temperature is not exceeded in any case ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 11 3 2 External Device Dimensions OPC6115 3 6 O 312 301 3 1 f r 24V 299 1 f r 230V 294 50 5 Ma f r Stecker 24 V Schaltschrank ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Ye itec OPC6115 6315 12 321 25 181 75 Spannklotz f r Befestigung 93 25 93 25 211 25 211 25 29 25 181 75 335 75 Je Den Oe Dell 3 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen ads tec OPC6115 6315 13 3 3 External Device Dimensions OPC6315 Ausschnitt f r Schaltsschrank 312 298 1 4 SER ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Ye
19. for installation e The boot drive in the system Bios must be switched to USB in order to boot the device from the USB interface e Restart the device and insert a Windows CD e Install Windows and set up the basic data e With devices including touch screens the touch screen driver as well as the soft keyboard should be installed in order to ensure their full functionality With Windows CE 6 0 or Windows XP embedded a complete image can also be installed by using a USB stick ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 33 TouchScreen Driver Installation Note When installing the driver you ll have to take in account that the touch screen monitor is internally connected with the USB interface Touch screen monitor and PS2 mouse can be operated simultaneously The installation has to be carried out as described below e Switch on PC and boot e Access the service CD by using the Explorer and start the Installer file in the TouchScreen folder e Follow the on screen instructions and acknowledge the licence terms and conditions e Once the installer has completed the installation shut down the computer and restart it subsequently e After restarting the touch screen monitor has to be calibrated If the driver does not automatically start activate the setup menu via Start gt Settings gt Control panel gt Elo Touchscreen e Via the Calibration data menu calibrating the
20. he Technical details chapter ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e itec OPC6115 6315 25 7 4 Speakers The OPC60xx is equipped with two internal speakers the described key combinations the volume level is modified If the soft keyboard is installed the system volume is additionally displayed by a Note The volume can be set up by using the device front keys When activating display bar Increase system volume Decrease system volume ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Ye itec OPC6115 6315 26 7 5 USB Interface The USB interfaces are used for connecting peripherals with USB connection These interfaces comply with the USB 2 0 standard requirements Pin Number Signal Name 1 VDC eo 2 D 3 D 4 GND Note The device supports a maximum of 8 external USB mass storage devices If a USB Flash SSD is integrated a maximum of 7 USB mass storage devices can be connected Note The USB interfaces can be individually locked by using the Lock USB software tool USB Interface in Front panel One USB interface can be accessed from the front The interface is located under a plastic cover underneath the display The cover has a tab on the right hand side which is used for opening The plastic cover of the USB interface must be returned in protective position after use ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec
21. ises you with conditions to be observed in order to efficient use of the device and for software optimisation 1 3 Data Figures Modifications All texts data and figures are non binding We reserve the right of modification in accordance with technological progress At that point in time when the products leave our premises they comply with all currently applicable legal requirements and regulations The operator operating company is independently responsible for compliance with and observance of any subsequently introduced technical innovations and new legal requirements as well as for all usual obligations of the operator operating company ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 4 1 4 Trademarks lt is hereby notified that any software and or hardware trademarks further to any company brand names as mentioned in this User s Guide are all strictly subject to the various trademark brand name and patent protection rights Windows Windows CE are registered trademarks of Microsoft Corp Intel Pentium Atom Core 2 are registered trademarks of Intel Corp IBM PS 2 and VGA are registered trademarks of IBM Corp CompactFlash and CF are registered trademarks of SanDisk Corp RITTAL is a registered trademark of the Rittal Werk Rudolf Loh GmbH amp Co KG Any further additional trademarks and or brand names herein be they domestic or international are hereby duly ack
22. itec OPC6115 6315 14 340 90 155 80 126 50 dr 4c 7 Pen 30 90 185 90 340 90 Spannklotz f r Befestigung 87 372 60 Abb 2 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen ads tec OPC6115 6315 15 3 4 Mounting procedure Use the drilling template to drill holes according the mounting illustration in the control panel with the specified threading Insert the upper screws half way into the control panel and hang the device on the mounting links Tighten the screws and insert the rest of the screws Warning The device must be switched off before connecting or disconnecting any cables in order to prevent damage to the electronics The device may only be switched on after acclimatising to the ambient temperature in order to avoid condensate accumulation Make sure to meet the permissible voltage requirements for this device After switching off and before switching on you must wait for at least 5 seconds Note The device is connected to the power supply using a lead out terminal with a screw connection A ground connection does not have to be made because the grounding conductor of the device plug or supply connection serves this purpose If additional grounding conductors are attached to a grounding screw a wire diameter of at least 2 5 mm is specified ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 16 4 Add On Card Installation 4 1 Pre installa
23. n 0 50 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 35 9 1 1 Automatic Brightness Adaption Note The application of Automatic brightness adaptation allows the user to configure the respective display brightness The display brightness can be changed manually or alternatively automatically by enabling the Automatic brightness adaptation which controls the brightness automatically depending on the ambient light level Once the automatic brightness control is enabled the brightness can no longer be modified by using the front keys We distinguish between two different control modes with the automatic control Day mode Night mode Separate display brightness levels can be programmed for either of both modes amp Automatische Helligkeitsanpassung Eg Display Dimmung Automatische Display Dimmung Display Helligkeit im Tagbetrieb 100 gt Ee Display Helligkeit im Nachtbetrieb 30 Betriebsmodus x Xx s Nachtbetrieb Tagbetrieb Note The threshold for Day Night mode has to be determined individually by the user for each device The day mode is enabled as soon as the ambient brightness is high enough The display brightness should be set to a slightly higher level than at night The night mode is enabled if the ambient brightness level is low The display brightness can be set to a lower level in this mode The operating mode of the automatic
24. n 32 9 1 Configuration Center 34 9 1 1 Automatic Brightness Adaption 35 9 1 2 COM Input Configuration 36 9 1 3 Ignition 36 9 1 4 USB Lock Function 37 9 1 5 On Off Button Configuration 38 9 1 6 Exemplary RFID Application 39 9 1 7 Softkeyboard 39 9 1 8 Screen Mob 40 9 1 9 Softkeyboard 40 10 Technical Details 41 11 Service amp Support 42 11 1 ads tec Support 42 11 2 Company adress 42 ads tec GmbH Heinrich Hertz Str 1 e 72622 N rtingen OPC6115 6315 3 1 Remarks 1 1 Relevant Documentation for this device The following documents are essential for setting up and operating this device User Manual This Documentation Contains information for installation commissioning and operating the device along with technical data of the device hardware Website By using the website www ads tec de you can download drivers software user manuals leaflets and flyers from the Download section on the website Note We would recommend you make use of our website contents www ads tec de in order to ensure an optimised data quality and to be quickly and comprehensively informed of any technical modification Service CD Contains Drivers and User Manuals 1 2 Used Symbol Explanation Warning The Warning symbol refers to activities which might cause personal injury or damage to the hardware or software ensure flawless operation Additionally hints and advice are given for a more Note The Note symbol familiar
25. nd protected from accidental switch on ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 19 6 Operation 6 1 Front Control Keys Abb 4 Depending on the device equipment version an operating system Windows CE net Windows XP embedded or Windows XP Prof and a soft keyboard are already installed ex factory The keys on the front panel are occupied with the following functions by a specific driver in the soft keyboard Level 1 Activate and deactivate the soft keyboard for letter character input using the touch screen Level 2 Decrease display brightness Level 1 Change task Alt ESC in Windows Level 2 Increase display brightness Level 1 Not connected Level 2 The volume can be decreased with devices equipped with an audio output Level 1 Right mouse key function Level 2 The volume can be increased with devices equipped with an audio output Shift key SHIFT for activating the second keyboard level This key must be pressed simultaneously with the desired function key Note If the software keyboard is not installed only the functions for display settings and volume control are active The controller display will not be output on the display in this case The key functions can be modified in accordance with customer specific requirements Above described functions are pre set ex works ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e itec
26. nowledged 1 5 Copyright This manual including all contained figures is protected by copyright law Any use for third parties non compliant with the copyright provisions is prohibited Any reproduction translation as well as electronic and photographic archiving and modification shall only be permitted after explicit written authorisation by ads tec GmbH Any party in violation of this provision shall be obliged to damage compensation ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 5 1 6 Environmental Conditions The device may be operated under the following conditions Failure to observe these specifications will terminate any warranty for this device Ads tec cannot be held liable for any damages arising due to improper use and handling e Temperature for devices including a fan in operation 5 45 C for storage 20 60 C e Temperature for devices without a fan in operation 5 40 C for storage 20 40 e Humidity In operation 10 85 without condensate For storage 10 85 without condensate e Vibration resistance In operation 1G 10 500 Hz DIN EN 60068 2 6 e Shock resistance In operation 5 G with a half wave of 30 ms duration DIN EN 60068 2 27 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 6 1 7 Standards This device complies with the requirements and protective aims of the following EC regulations Standards
27. ns and or variations Avoid overheating during unit operations the unit must not be exposed to direct Warning For the prevention of water condensate accumulation the unit should be turned sunlight or any other direct light or heat sources ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 9 2 2 Damage Caused By Improper Use This device must immediately be shut down and protected from any accidental commissioning if the operating system shows any obvious damage caused by for example improper operating or storage conditions or by improper use or handling 2 3 Warranty Repair During the warranty period any repair must only be carried out by the manufacturer or by a person authorised by the manufacturer 2 4 Treatment and Disposal of Lithium Batteries This device contains a lithium battery for supplying the system clock with power as long as the supply voltage is not connected The battery has a life cycle of 3 5 years depending on which load is applied Note The more the battery is exposed to higher temperatures the faster it ages Warning There is an acute risk of explosion should the wrong type of battery be used Warning Do not put lithium batteries into a fire do not solder on the cell body do not recharge them open them short circuit them do not reverse their polarity or heat them up over 100 C dispose of them properly and protect lithium batteries from di
28. rect sun light humidity and condensation Lithium batteries may only be replaced by the same type or by a type recommended by the manufacturer The lithium battery must be disposed of according to the local legislation at the end of its life cycle 2 5 Notes on Safety Warning Installation works at the device are only permitted if the device is disconnected from the power supply and protected from accidental switch on risk of being destructed by electrostatic discharges Note Always adhere to the safety measures applicable when handling components at DIN EN 61340 5 1 DIN EN 61340 5 2 ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 10 3 Mounting 3 1 Mounting Options This device is intended for integration into switch panels or switching cabinets In order to allow for a safe installation and operation connector access these switch panels or control desks must be accessible from the back The device can be integrated into switching cabinets with a wall thickness of 2 6 mm We recommend a minimum of 3 mm for correct installation with an IP65 front protection class Warning To avoid overheating in operation The device must not be exposed to direct radiation by sunlight or any other light or heat source If the device is integrated in a panel casing or similar enclosures you must ensure that no heat accumulation builds up The maximum permissible environmental temperature must n
29. s SYS LED BICOLOURED Depending on the colour and type of flashing different device states are displayed by the SYS LED The following signals are displayed e LED lights green The device is ready for operation Power ON e LED is off The device is switched off POWER OFF ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 23 7 Interfaces 7 1 Interface configuration Interface IRQ Adress COM 1 4 3F8h COM2 3 2F8h On the left side of the case the interfaces are arranged All interfaces are labeled The IEC connector or through terminal for the power supply is located on the right side of the control system Note Under the embedded operating system Windows CE net the communication interfaces COM USB etc have to be explicitly be enabled and drivers need to be installed 7 2 24V DC Power Supply The supply voltage is provided via a lead through terminal including a screw connection Phoenix Contact COMBICON MC 1 5 4 STF3 81 The figure shows the socket inside the device Pin Number Signal Name 1 2 3 1 24V DC ir 2 PE Sne 3 OV DC Technical Data of the input Input Max 130 Watt Input current 19 30 VDC current consumption 8 5A 24 VDC Max Input current 18A Note The power supply can be protected with a slow blow fuse of up to 4A Note The typical power consumption of this device is indicated in the Technical details chapter Note If the
30. ser might arise and any warranty claim will cease General Instructions e All users must read this manual and have access to it at all times e Installation commissioning and operation may only be carried out by trained and qualified staff e The security instructions and the manual itself must be observed by all persons who work with this device e Atthe location of use the valid guidelines and regulations for accident prevention must be observed e The manual contains the most important instructions on how to use this device in a safe way e Appropriate storage proper transport installation and commissioning as well as careful operation are prerequisites for ensuring safe and proper operation of this device e he device can be cleaned by using a soft cloth and a commercially available glass cleaning agent e g Sidolin with low alcohol content Warning Any installation works on the device are only permitted if the power supply is switched off and handling the device is safe 2 1 Operation Location The control system is designed for use inside a switching cabinet You must ensure compliance with the specified environmental conditions Using the device in non specified environments for example on board ships or in areas that might contain explosive gases or in extreme heights is prohibited ON only when it reaches ambient temperature This particularly applies when the unit is subject to extreme temperature fluctuatio
31. tationary use with a standard Ethernet or with radio networking cards installed on moving commissioning forklift equipment Platform including a hard disc Equipped with a hard disc for stationary use e g in the manufacturing department using a standard operating system ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 7 1 9 Scope of Delivery Please check that all of the following components are contained in the packaging e 1 x device e With 230 V AC devices Power cable including standard power plug for non heated devices e With 24 V DC devices 3 pin COMBICON plug from Phoenix Contact COMBICON MC 2 5 3 STF 5 08 already plugged in the device socket e Installation kit for installation Optional Scope of delivery e Operating System ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen e tec OPC6115 6315 8 2 Notes on Operation amp Safety This device contains electrical voltages and extremely sensitive components Intervention by the user is only designated for establishing the required cable connections The manufacturer or a service partner authorised by the manufacturer should be consulted if you plan to make further modifications Before beginning any works on this device it must be disconnected from the power supply Suitable measures for avoiding any electrostatic discharges towards components must be taken If the device is opened by an unauthorised person hazards for the u
32. tec OPC6115 6315 10 Technical Details 41 OPC6315 15 0 TFT 1024 x 768 Pixel max 16 1 Mio colours Device Data orcst15 i 15 0 TFT Display Resolution 1024 x 768 Pixel Represented colours max 16 1 Mio colours Touch Processor RAM Chipset Graficsmemory Mass storage Interfaces Network External Device Dimensions B x H x T Weight Power consumption ads tec GmbH Heinrich Hertz Str 1 72622 N rtingen Resistive Industrial Touchscreen Intel amp Celeron amp M 1 2 GHz Dual Core Intel Core 2 Duo 2 26 GHz 1 GB oder 4 GB DDR3 RAM Intel GMA X4500 integriert in GS45 max 256 MB shared 2 5 Automotive Hard Disk min 40 GB SATA 2 5 Hard Disk min 120 GB SATA 2 5 Industrial SSD SATA SMART 3 5 Hard Disk min 160 GB SATA 2 5 Industrial SSD SATA SMART DVD Burner 1 x COM 1 RS232 1 x COM 2 RS232 1 x DVI I 1 x USB 2 0 in front panel 1 x Ethernet 10 100 1000MBit RJ 45 3 x Ethernet 10 100 1000MBit RJ 45 via managed Switch 390 x 312 x 93 mm 390 x 312 x 152 mm 7 5 kg 130W typ 7 5 kg 150W typ OPC6115 6315 42 11 Service amp Support ads tec and its partner companies offer your customers a comprehensive service and support which ensures availability of a fast and competent support with respect to all upcoming questions related to ads tec products or assemblies Since the devices manufactured by ads tec are also used by associat
33. tion notes The user can install CompactFlash or PCI add on cards such as Interbus cards in the device The card slot is accessed by taking off the back cover The crosshead screws on the back of the control system should be removed for this purpose Achtung The components in the device are highly sensitive products which can be destroyed or impaired by improper handling The same applies to the PC add on cards to be installed Therefore the appropriate measures have to be implemented in all cases to avoid electrostatic shock to the components upon contact 4 2 Notes on configuring the add on card PnP The Ethernet and IDE controllers on the adsX board are connected via an internal PCI bus Therefore the addresses and IRQs are automatically assigned by the BIOS The following should be considered when installing or reconfiguring ISA cards Install and switch on device without ISA cards and then note down the assigned IRQs and addresses Install additional ISA cards in such a way that the IRQs assigned to PCI controllers are not used again Reserve IRQs for ISA cards in the BIOS 4 3 Installing add on cards e Switch off the device and all units connected to the PC and disconnect them from the power supply Unscrew the cover screws using a matching screwdriver and carefully remove the cover Warning The cover may be connected to mechanical parts in the device by a grounding wire Do not remove the cover with force Re

Download Pdf Manuals

image

Related Search

Related Contents

Romat Telecom – GHotel User's Manual  Schüttgutschieber Typ SGS Slide valve Type SGS  Restek 社製高感度リークディテクター リークディテクター ,P/N : 22839    GE WCCH404FWW User's Manual  Hotel Room Safe  utilisation du tracteur ` articule _ en exploitation forestiere  StarTech.com 1U 15" Rackmount LCD Console - USB + PS/2  PERRENOUD, Philippe  Rechercher dans le catalogue du CDI du Lycée Valin  