User manual ParasiTrap - System User manual ParasiTrap

image

Contents

1. well Do not shake in order to avoid loss of the parasite concentrate picture 8 For diagnosis usually 1 2 drops of concentrated stool suspension dilution per slide will be sufficient We recommend to read minimum 2 slides for an optimal diagnostics The cover glass preparation is now ready for the microscopic diagnostics Make sure that your preparation is not too thick picture 10 You must be able to read a newspaper text through your preparation clearly See also Important hints for the optimal utilisation of the ParasiTrap diagnostic system from Biosepar Processing by small size centrifuge Please use the additional screw cap instead of connected system with tube I and filter piece Further processing steps as above 6 10 Quality control and storage lod Close with cap against desiccation For later quality control or storage of the concentrated parasites please use the additional screw cap for processing tube II Please screw the cap firmly to avoid desiccation db biosepar Copyright by Biosepar GmbH Reprint prohibited except by written permission 2 Version 01
2. hand for approx 30 sec The part which remains in the upper vessel is transferred into the lower tube by shaking in vertical direction like shaking the old clinical thermometer During the whole shaking process active filtration occurs which further enhances the yield of parasites This device is designed in a way which provides an ideal relation between suspension volume precipitation rate The suspension is left as it is for 1 2 min The filtered suspension is centrifuged for 5 min at max 1500 g picture 6 processing by small size centrifuge see below Instead of centrifuge leave the system few hours until the phases have clearly separated After centrifugation four layers have been formed in the processing tube II The processing tube I including the filter piece is removed picture 7 dp biosepar 1 Resuspend the parasite concentrate according to demand with 0 05 0 5 ml physiological saline solution or Medium A AF SAF ECO Bailenger by repeated aspiration using the one way pipette If the concentrate sediment is sticky it should be diluted using more solution in order to obtain enough transparency for the microscopical examination picture 9 For more intensive staining of the concentrated parasites please use high diluted 1 10 Medium C The top layer which is solid has to be detached from the tube s wall by a cotton wool stick The processing tube II is carefully decanted Let it drain
3. User manual ParasiTrap System The stool samples are taken by using the plunger of the processing tube I which is attached to the screw cap A small sample spoon or a one way pipette for liquid stool may serve as auxiliary means The tightly closed tube is shortly shaken once to twice picture 1 The screw cap of the processing tube I is opened If necessary the stool suspension can be stirred with the plunger without using any additional aids you lift the screw cap approx 10 15 mm above the brim of the tube and insert it quickly again until it touches the brim of the tube picture 2 It is important not to lift the plunger above the surface of the fluid The screw cap of the processing tube I and the empty plunger is removed Add 1 5 ml Combi Medium carefully to the sample solution picture 3 ull NNT Screw the processing tube II with the integrated filter system firmly onto the properly loaded processing tube I from above Now the assembled system is rotated 180 to allow the sample transfer through the attached filter into the processing tube II picture 4 Mixed by shaker at maximum rotary speed for approx 10 15 sec It is enough to slightly press the upper tube with fingertips and simultaneously hold the system After this operation already half of the stool suspension will be collected in the lower cone shaped processing tube II picture 5 If no shaker is available the system ts shaken thoroughly by

Download Pdf Manuals

image

Related Search

Related Contents

Manual de uso e manutenção  BILAN CARBONE® TRIGANO VDL Site de TOURNON SUR RHONE  PC Software User Manual  SFM1 Sap Flow Meter Quick Start Guide  i Quaderni n. 2 aprile 2004 - Supplemento al n. 3/2004  BD LSR II User's Guide  NCDware System Administrator`s Guide for UNIX Systems        

Copyright © All rights reserved.
Failed to retrieve file