1. the New portable connected window appears Select Edit but don t save OK see figure below New portable connected Fep A new portable AMIE has been connected P Select one of the following actions O Save to database 2 Associate with existing portable J Run Template amp Edit but don t save The a51 Alarm Transmitter is added as an unknown entry in the PDM see figure below f Portable Device Manager TE Configuration About Exit Portable Add pfi I t ICU FILE IL EVICE gt 0 vare arg l Delete l i unknown AMIE unknown 0 0 FFFFFFFF 0000000 a51 1 2 0 0 4 Edit Parameters Factory Reset Repeat the software upgrade for this unit again The software upgrade is successfully performed when the Call No of the portable changes from unknown to its real Call No and gets online see figure below 2007 03 15 Ver C 14 User Manual Ascom a51 Alarm Transmitter TD 92351GB e Portable Device Manager ETE Portable Add Delete Edit Parameters Factory Reset Editing Parameters When delivered the Alarm Transmitter parameters usually is pre programmed If any settings should be changed the PDM can be used to edit the parameters For instructions on how to edit parameters see nstallation and Operation Manual Portable Device Manager PDM TD 92325GB Note If the ascom a51 Alarm Transmitter is ordered without customer programming the Use
2. 6 1 Operation Conalti n se ensenstaeseasineehseuneneee 10 6 2 Maintenance anq RED ANS essen ee 11 7 Related Documents u40000 0 0000 0 nenn nn nn nnn an nun nn an nun nn nn anna nun nenn nn nn nun anne nenne nenne 12 8 Document HISTOFV een 13 Appendix A Programming the Alarm Transmitter 14 2007 03 15 Ver C User Manual Ascom a51 Alarm Transmitter TD 92351GB 1 Introduction This document provides a description of the Ascom a51 Alarm Transmitter The Alarm Transmitter is described in default programmed version but additional functions and factory settings are also included providing a full description of the functionality Note that your system may not supply all functions described in this document For information about your system please contact your supplier The following documents are recommended as a complement e System Description Personal Security System TD 90677GB e System Description On site Paging System TD 91034GB LED Name label IR receiver internal Mute button Soft alarm button Alarm button 001 Figure 1 Ascom a51 Alarm Transmitter 1 1 Abbreviations and Glossary ALS Acoustic Location Signal A ramped up signal that can be played after an alarm from an Alarm Transmitter IR Infra Red LED Light Emitting Diode LF Low Frequency PCR Portable Charging Rack PDM Portable Device Manager SIM Subscriber Identity Module Syst
3. with power supply one PCR M and two PCR E 2 4 Accessories Leather case As accessory there is a leather case especially designed for the Alarm Transmitter used to increase the protection of wear and tear It is possible to use the Alarm Transmitter while it is placed in the case The clip of the Alarm Transmitter is not neccessary to remove d Figure 4 Leather case for the Ascom a51 Alarm Transmitter Security String See Pull cord Option on page 3 2007 03 15 Ver C 4 User Manual Ascom a51 Alarm Transmitter TD 92351GB Name label kit For the Alarm Transmitter aname label kit can be ordered The internal name label is possible to use for own means of identification 3 Safety Instructions Read this chapter before using your a51 Alarm Transmitter For sate and efficient operation of your Alarm Transmitter observe the guidelines given in this manual and all necessary safety precautions when using the Alarm Transmitter Follow the operating instructions and adhere to all warnings and safety precautions located on the product the Quick Reference Guide and this User Manual Charging This product shall only be used with the following batteries P N 660089 Battery Desktop chargers shall only be connected with power adapters supplied by the manufacturer Available power adapter P N FW7650 05 Power supply unit AC 5V DC 1A Warranty notification Do not disassemble the Alarm Transmitter Disassembling the han
4. TD 92351GB User Manual Ascom a51 Alarm Transmitter 2007 03 15 Ver C User Manual Ascom 351 Alarm Transmitter TD 92351GB Contents TINtLOQUCL ON tie ae be a bevedetvcoeccsstsatdssveucelalaveanecsancecagesa 1 11 JADD GVISUORS dno 431955 dE ann Rene 1 1 2 Ascom a51 Versions sola aic cons Basement ort de ot utendi hlodemdusib ssmee uiis 2 2 DESCI 1 01 9 a rc CE 2 25 Ascot a5T ates IRONS MICRON oio 5 d0cSocndac euzsand neon eat 2 2 2 Single Charger for Ascom a51 Alarm Transmitter nennen 3 2 2 PCR GHALGING RACK een nenne 3 SP MA AG cis ed sic AERE a E NE EOE SPORE NTO RR EELNE NET EET ER ELEN WONT TES 4 3 Safety Instr ctlors siue een 5 A Basic Operation anne 6 4 1 Switch the Alarm Transmitter On Off 2 22 22 6 4 2 Mute the Beep Vibrator LED Signal sun aa 6 T Snare Ote y aiit tos Sieb ottenuta aa A 6 SAlam PURGCTIONS RETE T n 7 B Buskspbibtto m EIS esse ee Ice ol cim S ECT lerne 8 5 2 Pull cord Alarm sot et ti cbe eti e e tue ab e ob dbuees 8 5 3 Man down amp No movement Alarm ses RR Reines 8 5 4 AcoustcTocation SIGMA UNES susci sciatis ueneno p bebat dba rte ieu 9 S5 Fosatdobi eon M ODE eren tovt ne textu TOREM CEN e CE sen 9 5 0 5DeClal OCatl ON 10 SA Sau aha al We PEN EN sche ota saute canto eau ERE E REE ETE N HERNEHERSERRE 10 5 0 Desatvale attivate Alat ae ne ae Be idee 10 5 9 Show Status of the Alarm Transmitter ssesese ene 10 G Operation Notices es nennen 10
5. ble with parameters A beep vibrator LED signal can confirm that an alarm has been sent These feedback signals of a sent alarm are all configurable The alarms are handled by FIFO First In First Out and thus no alarm prioritation is made by the system Common alarm configurations The following parameters are common for the Test alarm Alarm Soft alarm Man down amp No movement and Pull cord alarm types e Number of alarm transmissions per sequence e Beep teedback e LED teedback e Vibrator feedback e Alarm deactivation Only Man down amp No movement alarm 5 1 Push button Alarms Test alarm Press the Alarm or Soft alarm button for at least one second Depending on set parameters a beep is heard the green LED flashes once and the vibrator stirs Note To test the Alarm Transmitter and system a test alarm should be sent every day Alarm Press the Alarm push button twice or more Depending on set parameters a beep is heard the green LED flashes once and the vibrator stirs Soft alarm This alarm can be used as a request for discreet assistance Press the Soft alarm push button twice or more Depending on set parameters a beep is heard the green LED flashes once and the vibrator stirs 2007 03 15 Ver C 7 User Manual Ascom a51 Alarm Transmitter TD 92351GB Configuration of push button alarms The following parameters are configurable e Alarm type for multiple press e Alarm type for single pres
6. d for 10 minutes When the warning signal sounds press and hold the Mute button to delay the next warning signal 10 minutes One long beep followed by vibrator indicates that the Extra delay is set Configuration of Man down amp No movement Alarm The following parameters are configurable e Time of Man down detection phase time of a tilted state e Time of No movement detection phase time of a non moving state e Time of Man down No movement Warning MDW phase e ALS activation e Extra delay activation 2007 03 15 Ver C 8 User Manual Ascom a51 Alarm Transmitter TD 92351GB 5 4 Acoustic Location Signal ALS Depending on set parameters the ramped up Acoustic Location Signal ALS is played after an alarm The signal is always ramped from the lowest volume to the highest Press the Mute button to turn the ALS off 5 5 Location Function IR or LF The location of the Alarm Transmitter received via either infrared light IR or low frequency transmission LF is automatically sent along with an alarm If both IR and LF are enabled the Alarm Transmitter first handles IR and then LF If a location is detected the location function is put to sleep until the next scan interval which is defined by a parameter Depending on set parameters a beep signal and or a flashing green LED indicates that a location a new or the same has been received Note An Ascom a51 Alarm Transmitter with an IR receiver must always be visible ne
7. dset voids the warranty The a51Alarm Transmitter consists of no consumer serviceable components Service should be performed only by Authorized Service centre Modifications Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC compliance statements This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help 2007 03 15 Ver C 5 Us
8. em 900 Generic term for telePROTECT teleCOURIER and CTS 900 systems 2007 03 15 Ver C 1 User Manual Ascom a51 Alarm Transmitter TD 92351GB 1 2 Ascom a51 Versions The a51 Alarm Transmitter included in the Personal Security System is easy to carry and operate and is designed to function in tough environments It is available in two different versions basic and advanced a51 Basic a51 Advanced Push button alarms Yes Yes Pull cord alarm Yes Yes Vibrator alert Yes Yes Man down amp No movement alarm NO Yes Acoustic Location Signal ALS NO Yes Location function IR and LF NO Yes Battery check function Yes Yes Alarms are transmitted on the UHF band 420 475 MHz The code format is compatible with the System 900 which means that functions and units from the two systems can be integrated with each other 2 Description 2 1 Ascom a51 Alarm Transmitter Case The case is made of durable PC ABS plastic and is IP40 classified The Alarm Transmitter also fulfils IEC 68 2 32 procedure 1 which makes it drop proof from one meter onto concrete Antenna The antenna used for communicating with the fixed system is integrated in the Alarm Transmitter This makes the Alarm Transmitter robust and easy to handle Top The transparent smoke coloured top covers the IR receiver integral name label On the top is also the LED Buttons The Alarm Transmitter has three buttons see also figure 1 on page 1 Alarm button big button o
9. er Manual Ascom a51 Alarm Transmitter TD 92351GB Information to user This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 4 Basic Operation Note The Ascom a51 Alarm Transmitter may have functions other than described here depending on the pre programmed parameters 4 1 Switch the Alarm Transmitter On Off Insert remove the battery 4 2 Mute the Beep Vibrator LED Signal Press the Mute button 4 3 Charge the Battery Three battery levels exist e OK e Warning e Shutdown During the battery warning phase a beep signal played once each 10 s during one minute and a fast flashing red LED indicates a low battery Place the Alarm Transmitter in a Single Charger or a wall mounted Charging Rack If a Charging Rack is used for charging just insert the Alarm Transmitter without opening the clip to make it fasten securely Be sure to hear a beep and see the LED charging indication when inserting the Alarm Transmitter in the charging rack A slowly flashing orange LED indicates charging A green steady LED indicates a fully charged battery It takes approximately two hours to fully charge the battery Note that it is normal for the battery to get slightly warm while charging If the battery level goes below
10. itter can be used without the Pull cord option Remove the Pull cord and plug the hole with the provided ABS lid 2 2 Single Charger for Ascom a51 Alarm Transmitter The Single Charger is a separate unit used for charging the Alarm Transmitter It is connected to a power supply The power supply has four exchangable plug in contacts which fit into an ordinary wall socket in many countries CN e e Figure 2 Single Charger for Ascom a51 Alarm Transmitter For further information about the Single Charger refer to its Data Sheet TD 92353GB 2 3 PCR Charging Rack The wall mounted PCR Charging Rack is used for charging Ascom a51 Alarm Transmitters The Charging Rack is a modular system that consists of a master module PCR M extension modules PCR E and power supplies Each Charging Rack module has six charging slots 2007 03 15 Ver C 3 User Manual Ascom a51 Alarm Transmitter TD 92351GB One PCR M can support up to 20 PCR E which gives a charging possibility of 126 Alarm Transmitters A power supply feeds up to three Charging Rack modules one PCR M and two PCR E which results in seven power supplies for the above example Alarm Transmitters with a pull cord and or a security string can be charged in the PCR Charging Rack without removing the pull cord or security string For further information about the PCR Charging Rack refer to its Data Sheet TD 92355GB and Installation Guide TD 92356GB Figure 3 PCR Charging Rack
11. lace the Battery above The SIM card is placed under the battery unit in a hatch See 1 in figure 7 on page 11 Press down the flexible stop 1 and move the SIM card back as far as possible 2 Be sure that the SIM card is entirely out of the hatch before removing it The easiest way to ensure this is to turn the Alarm Transmitter upside down and let the SIM card falls out in your hand 2 Replace the SIM card with a new see 2 in figure 7 on page 11 Put down the SIM card so it lies flat on the flexible stop 1 and push it carefully into the hatch 2 Note Be careful not to bend the SIM card Figure 7 Removal and replacement of the SIM card 2007 03 15 Ver C 11 User Manual Ascom a51 Alarm Transmitter TD 92351GB Replace the Name Label Open the battery lid see section Replace the Battery above replace the old name label with a new from the Name label kit extra ordered Restore the Clip The clip has a special release function to prevent it from breaking when strained When the clip is released and becomes slack just snap it back with a hard press If the clip has fallen entirely off its fastening perform the following 1 Put the axle of the link clip in the closed hole on the clip see 1 2 Push the axle until it snaps into the open hole in the clip 3 Snap the clip to the Alarm Transmitter with a hard press Figure 8 How to restore the cl p 7 Related Documents Installation and Operation Manual Portab
12. le Device Manager TD92325GB 2007 03 15 Ver C 12 User Manual Ascom a51 Alarm Transmitter TD 92351GB 8 Document History For details see change bars in the document version pate peson oo 2007 03 15 Update with safety instructions special location and external alarm 2007 03 15 Ver C 13 User Manual Ascom a51 Alarm Transmitter TD 92351GB Appendix A Programming the Alarm Transmitter The Ascom a51 Alarm Transmitter parameters can be programmed using the Portable Device Manager PDM software PDM SB To program the Alarm Transmitter do as below 1 Connect the RS232 Programming Adapter to the computer 2 The computer COM port corresponding to the RS232 Programming Adapter and the COM port settings for the PDM software must match The PDM software uses default COM port 1 but can be changed as follows 1 In the Start menu select PDM Configuration 2 In the PDM Configuration window select desired COM port gt Save POM Configuration ComPort oe Start the PDM application 4 Connect the Ascom a51 Alarm Transmitter to the RS232 Programming Adapter For instructions on how to use the PDM see Installation and Operation Manual Portable Device Manager PDM TD 92325GB Note If the software upgrade of the Ascom a51 Alarm Transmitter is interrupted for example if the cable is removed the a51 Alarm Transmitter turns to download mode shown by a steady red LED When the a51 is connected again
13. n the front of the handset for sending alarm The button can also be used for test alarm The function of this button is configurable Soft alarm button small button marked with used as a request for discreet assistance The button can also be used for test alarm The function of this button is configurable Mute button button on the right side used to silence the beep vibrator and LED signal including the Acoustic Location Signal ALS 2007 03 15 Ver C 2 User Manual Ascom a51 Alarm Transmitter TD 92351GB Clip On the back of the Alarm Transmitter there is a clip used to fasten the Alarm Transmitter to for example the belt or pocket Battery The battery placed behind the battery lid is a rechargeable Li Ion battery SIM Card All personal settings in the Alarm Transmitter are programmed and stored in the Subscriber Identity Module SIM card The SIM card can easily be moved to another Alarm Transmitter By this it is easy to keep personal settings such as identity and alert signal This can be handy in case of break down or when changing operation environment and switching Alarm Transmitter Pull cord Option The pull cord is made of an ABS attachment connected to a canvas ribbon The end of the ribbon has a clip which must be safely attached for example to the clothes The Pull cord Is also used as a security string which prevents the Alarm Transmitter to for example fall on the ground The Alarm Transm
14. on to see the status 6 Operation Notice 6 1 Operation Condition Alarm Transmitter Only use the handset in temperatures from 10 C to 55 C Avoid exposing in direct sunlight and other heat sources Protect your Alarm Transmitter from aggressive liquids and vapours Keep the Alarm Transmitter away from strong electromagnetic fields and explosive environments Battery Do not immerse in water or throw into fire Use the Single Charger or wall mounted Charging Rack for charging Charge the battery for at least two hours the first time you use it See also 4 3 Charge the Battery on page 6 6 2 Maintenance and Repairs Use only original accessories Installation and repairs should be done by authorised personnel only Keep the recharging contacts on the Alarm Transmitter away from metallic and greasy objects 2007 03 15 Ver C 10 User Manual Ascom a51 Alarm Transmitter TD 92351GB Replace the Battery Two plastic ribbed plates at the back of the Alarm Transmitter are used to lock unlock the battery lid Open the battery lid Pull the plates upwards to release the battery lid see 1 in figure 6 below Put the battery into the battery compartment 2 Put on the battery lid and close it by pulling the plates downwards 3 Figure 6 Battery replacement Remove the SIM Card Note It is recommended that the SIM card is changed in an environment without static electricity 1 Remove the battery see section Rep
15. rlD has to be set before editing other parameters Upgrading the Firmware Follow the instructions in nstallation and Operation Manual Portable Device Manager PDM TD 92325GB 2007 03 15 Ver C 15
16. s long press 1 s by default e Time of push button press for single press e Number of presses for multiple press alarm e ALS 5 2 Pull cord Alarm An alarm is sent when the pull cord is pulled off the Alarm Transmitter Depending on set parameters a beep vibrator LED signal confirms that the alarm has been sent Note Make sure that the clip of the Pull cord is safely attached to the clothes To make a test remove the battery of the Alarm Transmitter pull the Alarm Transmitter and make sure that the pull cord releases first Configuration of Pull cord Alarm e ALS 5 3 Man down amp No movement Alarm Man down alarm The Alarm Transmitter is tilted more than 55 for a preset time for example when falling No movement alarm Movement is not detected during a pre set time Before the alarm is sent the Alarm Transmitter enters a warning phase called Man down No movement Warning MDW with a repeated warning tone default 7 seconds The beep signal always starts with a pair of low volume beeps and then continues with high volume beeps and is alternating with the vibrator Press the Mute button during this warning phase to prevent the alarm from being sent If the Mute button is not pressed an alarm is sent Depending on set parameters a beep vibrator LED signal confirms that the alarm has been sent Extra Delay If the parameter Extra delay is enabled the detection of Man down amp No movement alarm can be disable
17. the shutdown level a shutdown warning beep is played for 10 s after which the Alarm Transmitter enters deep sleep The best way to wake up the Alarm Transmitter from deep sleep is to put it into a Single Charger or wall mounted Charging Rack It is also possible to make a cold start see 4 1 Switch the Alarm Transmitter On Off on page 6 Note While the Alarm Transmitter is attached to the Single Charger or put in the wall mounted Charging Rack only the push button alarms Alarm and Soft alarm button and the Pull cord alarm are enabled This means that if existing Man down amp No movement alarms are deactivated The Location Function IR and LF is also deactivated If a push 2007 03 15 Ver C 6 User Manual Ascom a51 Alarm Transmitter TD 92351GB button alarm is sent the last stored location before charging the Alarm Transmitter is sent Note If the Alarm Transmitter is put into the charger during the shutdown warning beep the beep will stop and the Alarm Transmitter will not enter deep sleep at this time Note Check the battery status every time you start to use the Alarm Transmitter It is recommended that the Alarm Transmitter is charged daily This is even more important when the Alarm Transmitter is used in temperatures below O C 5 Alarm Functions In order to assure a safe transmission of an alarm to the system every alarm is sent in two sequences The number of times to resend an alarm in each sequence is configura
18. ver covered see figure 5 below Figure 5 IR function of Alarm Transmitter The following parameters are configurable e Reading of location code interval e Beep activation when receiving the location e LED activation when receiving the location 5 6 Special location If the fixed locators are set to send a special location code the portable automatically can send an alarm directly after it has received the code 5 7 External alarm The portable can send an alarm when triggered by an incoming external alarm signal A Single Charger has to be moditied for this purpose see Configuration Manual Ascom a71 Alarm Transceiver and p71 Transceiver TD 92439 2007 03 15 Ver C 9 User Manual Ascom a51 Alarm Transmitter TD 92351GB 5 8 Deactivate activate Alarms If this parameter is set the Man down amp No movement alarm can be turned off on by pressing twice on the Mute button Depending on set parameters a beep is heard the green LED flashes twice and the vibrator stirs when indicating deactivation activation of alarms See also 5 9 Show Status of the Alarm Transmitter below Note The Alarm and Soft alarm push buttons and Pull cord alarm are always enabled 5 9 Show Status of the Alarm Transmitter Green steady Battery OK all alarms active Green slow flashing Battery OK Man down No movement alarm deactive Red fast flashing Low battery indication Orange flashing Charging Press and hold the Mute butt