1. amp Co KG WACHENDORFF ee D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 5 1 Power Supply The device can be powered at 8 24V AC and 8 35V DC For more details see the two tables below Consumption at 24V DC Device ALMIGOOx IB Caution Not reverse the polarity power ALMIGOOx Connectori Power Supply OV Ground V Positive wire V AC min 8V max 24V IV DC min BV max 35V lt K Note The device cannot be fed only by the USB port Connector2 but it is necessary to use an external power supply on Connector1 D Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 25 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 5 2 Function Modes The device has got two functions mode depending of the position of the Dip2 of Dip Switch A e The first with Dip2 in Off position factory setting is used for the normal working of the device e The second with Dip2 in On position is used for upload the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section Accordi
2. hr Irrt mer und nderungen vorbehalten Stand 07 2014 9 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de However if the device doesn t go to Boot Mode automatically it is necessary to act on the Dip Switch A see FUNCTION MODES section for found the correct Dip and it is necessary to follow these instructions Turn Off the device Put the device at Boot Mode by Dip2 of Dip Switch A Turn On the device Check the LEDs LED1 and LED3 must blink quickly Connect the USB cable from the PC to the device Select the COM port e Select which operations you want to do You can select only Write Firmware only Write Configuration or both of them e Press the Update Device button to start the upload e When all operations are OK turn Off the device e Put the device at Normal Mode by Dip2 of Dip Switch A At this point the Configuration Firmware on the device is correctly updated ALMIOGOx INIT OK FIRMWARE Write in Progress PROJECT Waiting ALMIOGOx Ver 1 004 INIT OK Be FIRMWARE OK PROJECT OK Note When you install a new version of the software it is better if the first time you do the update of the Firmware in the ALMIOGOx device Note d When you receive the device for the first time you have to u
3. Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 18 Wachendorff Prozesstechnik GmbH amp Co KG WACH e RI DORF ffs IndustriestraBe 7 D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de Call Ra Wachendorff ALMIOGOx test222 Bu WACHENDORFF e Prozesstechnik GmbH amp Co KG Ka M Al 3 rm M od m by ADFweb com Main Functions Load Configuration gt SMS CALL Digital Output 1 Save Configuration E Modify Output by CALL Ring Number B Hang Up Rings E Automatic Hang Up After Hang Up Rings Number E Update Device e New Configuration f Set output L Reset output Ft Impulse output Pulse duration Milliseconds Under Ring Number f Set output LC Reset output Alarm Setting Impulse output Pulse duration Milliseconds Above Ring Number Phone Setting f Set output LC Reset output Jk Impulse output Pulse duration Milliseconds Software Preferences Input Setting 49553366771155 Mr Mustermann Output Settin i Go 8 49885522336644 Mr Organge Date amp Time Setting e CES EA ENN Add Row Number Delete Row Number I Clear Table N fa A NA Figure 12 Output Setting gt CALL window By pressing the field CALL it is possible to enable the function of change the state of output using a Phone Call There are three types of operations e Autom
4. OV DC Din 5 7 em Dim G 8 Negative wire control In this case the Input have the fixed signal in the Positive wire Pin 5 7 and the other Pin 6 8 is driven for example by an Open Collector output Max 48V DC O Din 5 7 emm Din G B Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 29 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 5 6 Digital Output The Digital Output are clean contact relays It is possible to drive a load of maximum 24V DC that consume 250mA Connector3 Connector4 Digital Output Digital Output 2 Port 1 Port 12 34 0 Pin Dbeserpfon Port _______ 0 1 Relay contact T Relay contact Digital Output 2 DO2 Relay contact E 2 Relay contact Digital Output 1 OT A Warning Maximum voltage applied 24V DC A Warning Maximum current 250mA Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 30 Wachendorff Prozesstechnik GmbH S Co KG IndustriestraBe 7 WACHENDORFF D 65366 Geisenheim Tel 4
5. e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 11 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF ee D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 3 Software Preferences By pressing the Software Preferences button it is possible to select the language of the ALMIGOOx Ip WACHENDORFF 1 Prozesstechnik GmbH amp Co KGK S Y Ko Al arm M od em fy ADP webs com Main Functions Software Preferences Select Language New Configuration es English Load Configuration Italiano Save Configuration A Deutsch Update Device n Espanol Software Preferences iP i R Alarm Setting Phone Setting Input Setting Output Setting Or ka Date amp Time Setting Figure 7 Software Preferences window Copyright by Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 12 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF ee D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 3 1 Phone Setting By pressing the Phone Setting button it is possible to insert the PIN Code of the SIM Card Another thing that is possi
6. 5 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 2 4 Update Device By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if is necessary For doing this follow these instructions e Turn On the device e Connect the USB cable from the PC to the device e Select the COM port e Select which operations you want to do You can select only Write Firmware only Write Configuration or both of them e Press the Update Device button to start the upload When all operations are OK the Configuration Firmware on the device is correctly updated For the updating the device must be on Boot Mode This modality is self managed by the ALMIOGOx So when you press the Update Device button the device is automatically put on Boot Mode and when it have complete the operations is put on Normal Mode by ADFweb com Update Device Select COMport Select COMport O O coMm D Update Device Load Configuration Update Device e New Configuration Write Firmware Save Configuration Write Configuration GR Update Device Software Preferences D Phone Setting A Input Setting A Output Setting Date amp Time Setting Figure 5 Update Device window Copyright by Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew
7. 7 2014 D2 u WACHENDORFF 4 3 Profile Daily fw Wachendorff ALMIOGOx test222 Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de Date amp Time Setting __ DateTime e New Configuration Load Configuration Save Configuration E Update Device Software Preferences Phone Setting Input Setting Output Setting Date amp Time Setting gt sklyi ff Weekly2 Weekly 3 Daily Enable Profile Daily 1 00 00 03 00 06 00 09 00 11 30 12 00 15 00 18 00 21 00 23 30 Cia Ci Ci a a a a ff fnn MT A M MA M A MA MA mA mA A E o o A a 9 a A A A 9G A A A A A A A e 9 a Enable Profile Daily 2 00 00 03 00 06 00 09 00 11 30 12 00 15 00 18 00 21 00 23 30 E 0 A A A a A a a a a A A A A A A A al al al a 1 M M A E a A al a ag A A A A HH A a 9 a A a a a V Enable Profile Daily 3 00 00 03 00 06 00 09 00 11 30 12 00 15 00 18 00 21 00 23 30 vA MA M A A A M A A A A A A A A A A aj a a Ci CC a aC 9 a a 9 Ka ag a af 2 Date Figure 13 Date amp Time Setting gt Profile gt Daily window There is the possibility to define up to three Daily Profile Daily For enable the Profile the field Enable Profile Daily X must be checked For each day there are 48 time slot of 30 minutes each A If an user have a Profile but the Profile isn t enabled the user cannot per
8. 9 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 5 7 Analog Input The Analog Input is 0 10V DC type The conversion is made by a 10 bit ADC Connector Analog Input Port H Negativewire O O Positive wire max 10V DC SE A Warning Maximum voltage applied 10V DC 5 8 SIM For removing the SIM card from the housing you must push the Button and extract the SIM holder Sloti SIM Card Slot 5 9 USB The USB connector Connector2 is a Type B Female So the cable must be a Type B Male 5 10 Antenna The Antenna connector is a SMA Female Female Outer Shell and Female Receptacle so the Antenna must have a SMA Male connector Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 31 u WACHENDORFF 6 Mechanical Dimensions 95 mm 3 74 inch Made in Italy wp direkt de DO1 DOZ Di DIZ Ali 71mm 2 79 inch Housing PVC Weight 200g Approx Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 60 mm 2 36 inch Figure 15 Mechanical dimensions scheme for ALMIGOOx Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geis
9. EE 21 SE B AVC Hr E 21 4 2 PIONIE WEEK see ee ee ee ee ee 22 Aco FONG DA areas ee ee er 23 5 CONNECCION SC NCMO erar nee een een 24 Ol Ge leie E 25 5 2 F HL ON MOOS S caececaze cect ee E 26 EE 27 SWIG Mall le e EE 28 SO DOA UN es weg gc gp ee se ce we ae ee 30 ANO MOU E 31 TO WEE 31 SEENEN 31 EAR ne ME 31 6 Mecnanical Bill EE 32 TOROS MING NOMA AION ze ee 33 7 1 WONG CVG EG 34 7 2 Other regulations and StAndardsS ccccccceecceceeeeceeeeeeeeeeeseeesaeeeeseaeeesaeeeeseeeeeeas 34 7 3 Warranties and technical Gupport nenne nenne nenne nenne nnnnnennnnnnn 34 PARCU PONY EE 34 Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 2 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de Introduction The GSM I O and Alarm Modem is a powerful flexible and economic instrument which is used to control Digital and Analog I O by SMS or Phone Call The instrument is composed of the following module hardware with GSM connection USB interface that connects to a personal computer two Digital Input terminal two Digital Output terminal one Analog Input terminal and a free software for MS Windows Linux and MacOS The Software To obt
10. Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 WACHENDORFF D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de User Manual GSM Alarm Modem ALMIOGOx Version 1 0 M Alar Supply 12 m Modem 30 VDC 0 2 A max Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 e Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de Idee GIG TO BEE 3 WS SOTA ee ne 3 BET E Ee 3 TSO CUI POUL eebe 4 1 1 General ATOM OV EEN 4 ESA enee RE 4 1 3 Qualiied Personnel EE 4 A RESIOUA FANG bo ee ee 4 1 9 CE COMO ee een 4 2 INS dE 5 SEENEN 6 272 WO aC COMM gU de 7 2 3 SAVES COMMON Ofen nee ae ee ee 7 2A Beet DEVICE nee ee EE 9 3 Software Preferences nenne nenne nenne nnnne nenne nennennnnenn 12 3 1 PHONE Set I e na ae ne a ee 13 32 put SCHUNG era ame an anne ae aces anna en ea ee ee 14 Digital Setting 2u02200002snnnenennnenennnenennnnnennennennonnnnnnnnnnnn nennen nenne nnenne nenne nenn nnennennnnnnn 14 Analog Setting nenne nnennennnnnennnnnennnnennnn 15 3 3 Output Setting nenn nnnnnnnennnonnnnenennnnnenne nenne nnnnnennnnnnn 16 GM 16 Kee 19 4 NALS ee TIME
11. ain the software please go to http www wachendorff prozesstechnik de fernwartung und fernwirken alarmmodems T eleservice Alarmmodems ALMIOGO1 htmll This manual is referenced to the last version of the software present on our web site The software works with MS Windows MS 2000 XP Vista Seven 8 32 64bit Linux and MacOS Characteristics This product has the following characteristics 2 Digital Outputs 2 Digital Inputs 1 Analog Input SMS alert of the change of state of the Digital Analog Input Setting Output via SMS and or call Mountable on 35mm Rail DIN Power Supply 8 24V AC or 8 35V DC Temperature range 20 C 70 4 F 158 F Copyright by Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 32 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 1 Security Alert 1 1 General Information To ensure safe operation the device must be operated according to the instructions in the manual When using the device are required for each individual application legal and safety regulation The same applies also when using accessories 1 2 Intended Use Machines and systems must be designed so the faulty conditions do not lead to a dang
12. arranties and technical Support For fast and easy technical support for your products consult our internet support at www wachendorff prozesstechnik de Otherwise contact us at the address eea wachendorff de 7 4 Return Policy If while using your product you have any problem and you wish to exchange or repair it please do the following 1 Obtain a Product Return Number PRN from our internet support at Wachendorff Prozesstechnik GmbH amp Co KG Together with the request you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 34
13. atic hang Up after Hang Up Risings Number used for hang up after the numbers of rings expressed in the field Hang Up Rings e Under Ring Number used for trigger an event if the number of rings is under the value expressed in the field Ring Number e Above Ring Number used for trigger an event if the number of rings is above the value expressed in the field Ring Number For all operations there are the three possibilities like the use of SMS i e e Set output used for close the relay contact e Reset output used for open the relay contact K Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 19 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de e Impulse output used for make an impulse with a defined duration The duration of the impulse is defined with the field Pulse duration Milliseconds In the table it is possible to insert the various Phone Numbers and give a Profile for each Number The possible Profile are the same described in the subsection SMS of section OUTPUT SETTING Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Indus
14. ble to do is enable the Automatic switch of the Time this by acting the field Enable automatic switch in daylight saving time and beck Only for Europe This feature is available only for Europe Bu WACHENDORFF 1 Prozesstschnik GmbH amp Co KGK Y Ko Al arm M ode m BEER Phone Setting PIN Code e New Configuration 1234 wm Load Configuration Enable automatic changeover of daylight saving time Only for Europe m Save Configuration E Update Device Software Preferences Phone Setting Input Setting Output Setting Date amp Time Setting Figure 8 Phone Setting window Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 13 Wachendorff Prozesstechnik GmbH amp Co KG WACH e RI DORF fs IndustriestraBe 7 D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 3 2 Input Setting Digital Setting LR s Digital Setting Inputi f E i Digital Input 1 tis Send SMS if Digital Input change from value 0 to value 1 Bim Alarm activation time Milliseconds New Configuration Load Configuration Save Configuration Update Device Software Preferences Alarm Setting E Send SMS if Digital Input change from value 1 to value 0 Phone Setting Alarm act
15. chnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 27 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 5 4 Digital Input There are two types of Digital Input that the device can have e The one that controls with the signal on the Positive wire e The one that controls with the signal on the Negative wire Connector5 Connector6 Digital Input Digital Input 2 Port Coo n OO Descrip O Po O u 6 Negative wire Pigital Input DI S SC Negative wire iCal Input 2 D2 A Warning Maximum voltage applied 48V DC A Warning Minimum voltage applied 12V DC Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 28 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de Positive wire control In this case the Input have a fixed signal that is the ground of the signal Pin 6 8 and to the other Pin 5 7 there is the positive signal that can be applied or not Max 48V IT
16. e Setting Profile i DateTime BEIER 2 il o Date Enable Profile Weekly 1 00 00 03 00 06 00 09 00 11 30 12 00 15 00 18 00 21 00 23 30 Monday Tuesday Wednesday RE aa a a a a a a a a a g a m aa a a a a a a a a a Fa a a a FT a Ca Friday ap ea ea a Fa a aa a a Fa a a a a a aa aa a a a aaa a a aa a a FT KS KS a D KS KS KS KS ment HIPIPIEIEIEIEIEISISISIEIEIEIEIEIEIEIEIEIEIEEE EIEIEIEIEEEEEIEIEIEIEIEIEIEIEIEIEIEEEEE HEIPIPIPEEEIEIEIEIEISISISIRIRIREIEIEIEEE EIEIEIEIEEEEIEIEIEIEIEIEIEIEIEIEIEIEEEEE Si CH a CH a CH a u Sunday Figure 12 Date amp Time Setting gt Profile gt Weekly window There is the possibility to define up to three Weekly Profile Weekly 1 Weekly 2 Weekly 3 For enable the Profile the field Enable Profile Weekly X must be checked For each day there are 48 time slot of 30 minutes each A If an user have a Profile but the Profile isn t enabled the user cannot perform the event If you want to use one of Daily Profile you must insert one of these numbers in the Cell Profile of Output Setting gt SMS or Output Setting gt CALL sections e 1 for Weekly 1 e 2 for Weekly 2 e 3 for Weekly 3 Copyright by Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 0
17. enheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 32 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 7 Ordering Information The ordering part number is formed by a valid combination of the following ALMIOGO1 GSM Alarm Modem with 8 cm rod antenna ALMIOGO2 GSM Alarm Modem with mobile antenna 5m cable Accessories ALMOIGOx Software configurator PS24V03AA Power Supply for DIN rail 230VAC to 24VDC 3A KABUSB21 Programming Cabel USB A to USB B 1 8Meter Cabel Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 33 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 7 1 Disclaimer All technical content within this document can be modified without notice The content of the document content is a recurring audit For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user Wachendorff Prozesstechnik GmbH amp Co KG
18. erous situation for the operator i e independent limit switches mechanical interlocks etc 1 3 Qualified Personnel The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job 1 4 Residual Risks The device is state of the art and is safe The instrument can represent a potential hazard if they are inappropriately installed and operated by personnel untrained These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is danger for people to serious A injury or death and or the possibility of damage 1 5 CE Conformity The declaration is made by us You can send an email to eea wachendorff de or give us a Call if you need it Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 4 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF eege D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 2 Installation Extract the file downloaded from our web site and follow the procedure to install the software Use of S
19. form the event If you want to use one of Daily Profile you must insert one of these numbers in the Cell Profile of Output Setting gt SMS or Output Setting gt CALL sections e 4 for Daily 1 e 5 for Daily 2 e 6 for Daily 3 Copyright by Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 23 Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 WACHENDORFF D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 5 Connection Scheme Digital Output Digital Input 2 Port la L Port Dip Switch A Dipi Not used Dip2 Functioning Mode Device State Call orrai Boot Mode SIM CARD Fay WACHENDORFF C GSM Alarm Modem Supply 12 30 VDC 0 2 A max PIN ALMIOGO1 4 x Ian Made in Italy IODINE EO NE A wp direkt de DO1 DOZ Di Di2 Ali OV Ground V Positive wire V AC min 8V max 24V V DC min 8V max 35V Device State Modem State Figure 14 Connection scheme for ALMIOGO1 Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 24 Wachendorff Prozesstechnik GmbH
20. ivation time 100 Milliseconds Input Setting Output Setting Date amp Time Setting Figure 9 Input Setting gt Digital window The device has two Digital Inputs for both of them it is possible to do the same operations described in this section There are two possibilities Sending a SMS when the Input changing from 0 to 1 by checking the field Send follow SMS when Digital Input change from value 0 to value 1 Signal input 1 gt 8 VDC ISHS SES t Sending a SMS when the Input changing from 1 to 0 by checking the field Send follow SMS when Digital Input change from value 1 to value 0 Signal input 0 lt 3 VDC u SMS For both cases there is the possibility to insert also different phone numbers and different SMS texts For both cases the SMS will be sent only when the Input is to the other state for at least the time inserted in the field For a time major of Milliseconds Copyright by Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 14 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF ee D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de Analog Setting Digital amp Analog Input Analog Input 1 E Send SMS if value is higher tha
21. mp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 BE Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 2 2 Load Configuration By pressing the Load Configuration button it is possible to load an existing project by selecting one of the list that appears A device configuration can also be imported or exported e To clone the configurations of a GSM I O and Alarm Modem in order to configure another device in the same manner it is necessary to maintain the folder and all its contents e To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another name and open the new folder with the button Load Configuration Sw Wachendorff ALMIOGOx Example2 Bu WACHENDORFF Prozesstechnik GmbH amp Co KG S M S Al d rm M ode m Hauptfunktionen Projekt laden w hlen Sie eine vorhandenes Projekt Examplel Example2 Neues Projekt Projekt laden Projekt speichern FE E a E 3 E 3 3 Transfer Optionen x Alarm Einstellungen Telefon Eingang Ausgang Datum amp Uhrzeit Ok m Figure 3 Load Configuration window Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industrie
22. n Volt RTN Volt Sai DEER em Save Configuration ssa ee Alarm activation time Milliseconds New Configuration u Load Configuration is Hi 4911223336665 AE aeaa Update Device J R Software Preferences Alarm Setting NS ISIS E Send SMS if value is lower than 2 Volt RTN a Hysteresis m Phone Setting mr Add Row SMS Delete Row SMS Clear Table Alarm activation time Milliseconds sus es Pine amber Fee A wn Fee A Output Setting Date amp Time Setting Add Row SMS Delete Row SMS Clear Table Figure 10 Input Setting gt Analog window The device has one Analog Input The operations are described in this section There are two possibilities e Sending a SMS when the Input goes above a certain threshold voltage by checking the field Send follow SMS when Analog Input is Higher than Volt e Sending a SMS when the Input goes below a certain threshold voltage by checking the field Send follow SMS when Analog Input is Lower than Volt TNI e SHS For both cases there is the possibility to insert also different phone numbers and different SMS texts For both cases the SMS will be sent only when the Input is above or below for at least the time inserted in the field For a time major of Milliseconds Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angabe
23. n ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 15 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF ee D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 3 3 Output Setting The device has two Digital Outputs For both of them it is possible to do the same operations described in this section Le using SMS and or Call for trigger an event SMS Fle eae ps POLIT Ry WACHENDORFF Prozesstechnik GmbH amp Co KG S M ia Al arm M od em Main Functions Digital Output Digital Setting New Configuration we Output 1 Ab A Onpa Load Configuration by ADFweb com SMS Digital Output 1 Save Configuration E Modify Output by SMS f FSET output by SMS Turn On DO1 E E RESET output by SMS Turn Off DO1 ft E IMPULSE Output by SMS Impulse DO Pulse duration 100 Milliseconds Update Device Software Preferences LA E Enabled on Phone Number E Enabled on Password Alarm Settin SE Phone Setting Enabled users control phone number s 49225533667744 Mr Mustermann Input Setting 49998855336644 Er Mustermann Output Setting Add Row Number Clear Table Or ka Date amp Time Setting Figure 11 Output Setting gt SMS window By pressing the field SMS it is possible to enable the function of change the state of output using a SMS There are three possibilities e SET outpu
24. ng to the functioning mode the LEDs will have specifics functions see LEDS section Dip Switch A Dipi Not used Dip2 Functioning Mode Boot Mode Normal Mode K Note Using the GSM Alarmmodem ALMIOGOx software it is possible to put the device at Boot Mode for the updating of Project and or Firmware and also put the device at Normal Mode when these operations are finished This without restart the device and without operate with Dip Switch A Dip2 Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 26 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF ee D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 5 3 LEDS The device has got three green LEDs that are used to give information of the functioning status The various meanings of the LEDs are described in the table below 1 Device State Blink slowly Blink quickly Off Not initialized Call in progress Regular flashing Initializing 2 Modem State Off 3 second On second Ooff Initialized and connected to the phone cell Blink slowly Run 3 Device State Call Blink quickly Blink quickly Call in progress Led3 Green Device State Call Copyright by Wachendorff Prozesste
25. oftware GSM Alarmmodem ALMIOGOx Kack e Bu WACHENDORFF ei Prozesstechnik GmbH amp Co KG Sy M SS Al arm M O d em by ADFweb com Main Functions New Configuration Load Configuration Save Configuration Update Device Software Preferences m H x Alarm Setting Phone Setting Input Setting Output Setting Date amp Time Setting Ob i m Figure 1 Main window for ALMIOGOx Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 5 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF ee D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 2 1 New Configuration By pressing the New Configuration button it is possible to create a new project assigning the name in the field near the button OK that is used for create it le GI eleng Bn WACHENDORFF wf Prozesstechnik GmbH amp Co KG S M Al a r m M Oo d e m by ADFweb com Main Functions New Configuration Insert the name of new configuration New Configuration Load Configuration Save Configuration Update Device Software Preferences Phone Setting Input Setting Output Setting Date amp Time Setting Figure 2 New Configuration window Copyright by Wachendorff Prozesstechnik GmbH a
26. pdate also the Firmware in the ALMIGOGOx device Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 10 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de Warning A If the Fig 6 appears when you try to do the Update before require assistance try these points ALMIOG0x INIT PROTECTION Ver 1 004 FIRMWARE PROTECTION PROJECT PROTECTION Figure 6 Protection window e Check if the serial COM port selected is the correct one e Check if the Cable is connected between the PC and the device e Try to repeat the operations for the updating e Try to use another USB port e Try to restart the PC e Try with another PC e lf you are using the program inside a Virtual Machine try to use in the main Operating System e lf you are using Windows Seven or Vista make sure that you have the administrator privileges e Take attention at Firewall lock A In the case of ALMIGOOx you have to use the software GSM Alarmmodem ALMIGO0O1 http www wachendorff prozesstechnik de fernwartung und fernwirken alarmmodems html eID pim_download amp rid 281 amp did 5577 Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra
27. sible to change the Date amp Time of the device There are two possibilities e Insert an own Date amp Time by compiling the fields hh mm ss dd mm yy and then pressing the button Set Custom Date amp Time e Insert the PC date amp Time by pressing the button Set PC Date amp Time It is possible also read the Date amp Time of the device and also the Firmware Version by pressing the Read Status Device button For doing these operations it is necessary to connect the device through the USB to the PC and select the COM port A The device must be at Normal Mode A For the year yy you have to insert only the last two digits Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 21 Wachendorff Prozesstechnik GmbH amp Co KG WACH e RI DORF ffs IndustriestraBe 7 D 65366 Geisenheim 4 2 Profile Weekly Be Wachendorff ALMIOGOx test222 Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de Bu WACHENDORFF Prozesstechnik GmbH amp Co KG S M Si Al arm M od em Main Functions New Configuration Load Configuration Save Configuration Update Device Software Preferences Phone Setting Input Setting Output Setting Date amp Time Setting Date amp Tim
28. stra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF ee D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 2 3 Save Configuration By pressing the Save Configuration button it is possible to save the project There are two possibilities or save the current configuration by pressing the button Save or save with a new name by pressing the button Save As and writing the name in the field above the button Ip WACHENDORFF H Prozesstechnik GmbH amp Co Me Al arm M od em DEE Main Functions Save Configuration Save Current Configuration a Save Current Configuration As Insert new name of configuration New Configuration Load Configuration Save Configuration Update Device Software Preferences Alarm Setting Phone Setting I x Input Setting Output Setting Ol i m Date amp Time Setting Figure 4 Save Configuration window Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 8 Wachendorff Prozesstechnik GmbH amp Co KG WACH e RI DORF ffs IndustriestraBe 7 D 65366 Geisenheim Tel 49 0 67 22 99 6
29. t by SMS used for close the relay contact e RESET output by SMS used for open the relay contact e IMPULSE Output by SMS used for make an impulse with a defined duration The duration of the impulse is defined with the field Pulse duration Milliseconds A The maximum value that the impulse can have is 60000ms Copyright by Wachendorff Prozesstechnik GmbH amp Co KG IndustriestraBe 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 16 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de For all cases there is the possibility to insert in the field near the event the text of the SMS that is used for trigger the event If the field Enabled on Phone Number is checked only the phone number written in the table is able to do the operation to the Digital Output otherwise all numbers that send the defined SMS are able to do the operation If the field Enabled on Password is checked the SMS sent must contain the password written in the field near the command lt is possible to select only one of them both of them or none of them If none of them are selected all numbers can perform an event Below there are some examples of the functioning with all cases 4 It is possible
30. to write also other words in the SMS the important thing is that the SMS text have to contain exactly the text defined in the compositor 4 The Password can have a maximum length of 16 characters All characters are accepted If the field Send back an echo SMS is checked the device sends back to the sender the same SMS if the event is successful done In the table Enabled users control phone number it is possible to insert the various Phone Numbers and for each Number give a Profile The possible Profile are O Always enabled Weekly 1 Weekly 2 Weekly 3 Daily 1 Daily 2 Daily 3 Date 1 Not used in this moment Date 2 Not used in this moment Date 3 Not used in this moment O oo N Oa SS WN Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 17 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de Phone Number impt b_ aul e i Figure 11 Examples for Enabled on Phone Number and Enabled on Password Copyright by Wachendorff Prozesstechnik GmbH amp Co KG Industriestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne
31. triestra e 7 D 65366 Geisenheim Tel 06722 9965 20 Fax 78 Angaben ohne Gew hr Irrt mer und nderungen vorbehalten Stand 07 2014 20 Wachendorff Prozesstechnik GmbH amp Co KG WACHENDORFF a D 65366 Geisenheim Tel 49 0 67 22 99 65 20 Fax 49 0 67 22 99 65 78 www wachendorff prozesstechnik de 4 Date amp Time Setting By pressing the Date amp Time Setting button it is possible to change the Date amp Time of the device and create the Profiles The Profiles are used for limiting the time of the operations that the users that have assigned a Profile can perform A Profile O is used for give to an user the possibility to make the operations all the time in a day 4 1 Date amp Time Be Wachendorff ALMIOGOx test222 Bn WACHENDORFF Prozesstechnik GmbH amp Co KG S M Al arm M od em by ADFweb com d Main Functions Date amp Time Setting Date amp Time e New Configuration Select COMport ag wm Load Configuration GOM g Set Date amp Time EH Save Configuration Date amp Time mm ss mm yy e CS 12 Un oo ae i Update Device l P Software Preferences vn Alarm Setting Date Time Firmware Version Phone Setting Input Setting Output Setting Date amp Time Setting Ob kB Figure 12 Date amp Time Setting gt Date amp Time window In this section it is pos
32. will not be liable for accidental loss of use or inability to use this product such as loss of business income Wachendorff Prozesstechnik GmbH amp Co KG shall not be liable for consequences of improper use 7 2 Other regulations and standards WEEE information Disposal of old electrical and electronic equipment as in the European Union and other R European countries with separate collection systems mmm nis symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE The device respects the 2002 95 EC Directive on the restriction of the use of certain KoHS hazardous substances in electrical and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or RoHS 2002 95 EC CE MARKING C The product conforms with the essential requirements of the applicable EC directives 7 3 W