Home

User Manual - ads-tec

image

Contents

1. e The device meets the DIN EN 60068 2 6 test requirements sinus excitation e The device meets the DIN EN 60068 2 27 test requirements shock resistance test Note All connected components as well as cable connections must also meet these requirements for compliance with the EMC legislation For this reason screened bus and LAN cables including screened connectors must be used and installed according to the instructions in this user manual Note By using the CE conformity declaration in this document you can find detailed information about the standards applicable to this device ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 9 Warning This is equipment of class A This unit might cause radio interferences in living areas in this case the operator might be obliged to take suitable protective measures at the operator s expense 1 8 EQUIPMENT VERSIONS The system is available in two equipment versions Platform including a Flash SSD Platform without any rotating mass storage medium hard disc etc and with an embedded operating system Windows CE 6 0 XP embedded for stationary use with a standard Ethernet Platform including a hard disc Equipped with a hard disc for stationary use e g in the manufacturing department using a standard operating system 1 9 SCOPE OF DELIVERY Please check that all of the following components are contained in t
2. 8 4 AUTOMATIC BRIGHTNESS ADAPTATION Note The application of Automatic brightness adaptation allows the user to configure the respective display brightness The display brightness can be changed manually or alternatively automatically by enabling the Automatic brightness adaptation which controls the brightness automatically depending on the ambient light level Once the automatic brightness control is enabled the brightness can no longer be modified by using the front keys We distinguish between two different control modes with the automatic control Day mode Night mode Separate display brightness levels can be programmed for either of both modes amp Automatic brightness control Display Dimming Automatic display dimming Disp Brightness for day mode 100 s Sea Disp Brightness for night mode 30 Operating Mode Es Night mode Day mode Note The threshold for Day Night mode has to be determined individually by the user for each device The day mode is enabled as soon as the ambient brightness is high enough The display brightness should be set to a slightly higher level than at night The night mode is enabled if the ambient brightness level is low The display brightness can be set to a lower level in this mode The operating mode of the automatic control can seamlessly be changed between day and night mode by using a slide control The closer the slider is to the day mode position
3. e Start installer from the service CD e Follow on screen instructions install the driver select the language and confirm the restart of the computer Note You can make further changes to the basic settings of the soft keyboard if required More information about this topic you ll find in the Readme file in the installation folder for the soft keyboard ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 38 9 TECHNICAL DETAILS OPceoixSeries ml ms Display Data Display 12 1 TFT 15 1 TFT 1024 x 768 Pixel 1024 x 768 Pixel Represented max 256K colours max 16 1 Mio colours Colours Automatic or manual display brightness adjustment TouchScreen Resistive Industrial Touchscreen Computer Data Processor Atom 1 6 GHz RAM 1 GB oder 2 GB DDR2 RAM Chipset Intel SCH US15W chipset incl integrated graphic controller Graphic memory max 8 MB shared Mass storage 2 x Flash SSD 1 x Flash SSD over interal USB Connection over interal USB Connection 2 5 Automotive Harddisk 40 GB UDMA 2 5 SSD PATA 2 2 GB Interfaces COM 1 RS232 connectable 5V power supply for scanner 1 x PS 2 Mouse Keyboard 2 x USB 2 0 1 x USB 2 0 in Front panel disconnectable Network 2 x Ethernet 10 100 1000MBit RJ 45 General Data External Dimenions 338 x 261 x 62 mm 400 x 305 x 65 mm Weight ca 3 3 kg ca 4 3 kg Protection Class Power consumption 100W 110W ads tec GmbH Heinr
4. CE net Windows XP embedded or Windows XP Prof and a soft keyboard are already installed ex factory The keys on the front panel are occupied with the following functions by a specific driver in the soft keyboard 8690090 6 Note If the software keyboard is not installed only the functions for display settings and volume control are active The controller display will not be output on the display in this case Level 1 Activate and deactivate the soft keyboard for letter character input using the touch screen Level 2 Decrease display brightness Level 1 Change task Alt ESC in Windows Level 2 Increase display brightness Level 1 Not connected Level 2 The volume can be decreased with devices equipped with an audio output Level 1 Right mouse key function Level 2 The volume can be increased with devices equipped with an audio output Shift key SHIFT for activating the second keyboard level This key must be pressed simultaneously with the desired function key The key functions can be modified in accordance with customer specific requirements Above described functions are pre set ex works 5 2 SOFT KEYBOARD If an operating system is installed ex works the soft keyboard is also preinstalled If the operating system is delivered separately with the device the soft keyboard must also be installed on site By using the soft keyboard data can be entered via the touch screen like with an exter
5. DEVICE The following documents are essential for setting up and operating this device USER MANUAL THIS DOCUMENTATION Contains information for installation commissioning and operating the device along with technical data of the device hardware WEBSITE By using the website www ads tec de you can download drivers software user manuals leaflets and flyers from the Download section on the website Note We would recommend to make use of our website contents www ads tec de in order to ensure an optimised data quality and to be quickly and comprehensively informed of any technical modification SERVICE CD Contains drivers and user manuals Note The service CD menu automatically starts if the autostart option for removable media is activated The service CD was created by using Adobe Flash The service CD menu is even available if the Flash Player is not installed 1 2 EXPLANATION OF USED SYMBOLS Warning The Warning symbol refers to activities which could cause personal injury or damage to the hardware and software Note The Note symbol describes conditions which unconditionally have to be observed in order to ensure trouble free operation Additionally hints and advice for the efficient use of this device and for software optimisation are given using this symbol HE ads tec GmbH e Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 7 1 3 DATA FIGURES AND M
6. ensuring safe and proper operation of the device e The device can be cleaned by using a soft cloth and a commercially available glass cleaning agent e g Sidolin with low alcohol content Warning Any leads e g power leads interface cables may only be connected if the device is switched off in order to avoid damaging the device 2 1 OPERATING LOCATION The control system is designed for use inside a switching cabinet You must ensure compliance with the specified environmental conditions Using the device in non specified environments for example on board ships or in areas that might contain explosive gases or in extreme heights is prohibited Warning The device may only be switched on after acclimatising to the ambient temperature in order to avoid condensate accumulation The same applies if the device has previously been exposed to extreme temperature variations To avoid overheating in operation The device must not be exposed to direct radiation by sunlight or any other light or heat source 2 2 DAMAGE DUE TO IMPROPER USE If the control system shows any obvious damage e g caused by improper operating or storage conditions or by improper use or handling you must immediately put the device out of operation and protect it from being accidentally switched on 2 3 WARRANTY REPAIR During the warranty period any repair must be carried out by the manufacturer or by persons duly authorised by the manufacturer
7. manufacturer should preferably be used If the soft keyboard is actively displayed on the monitor the use of the external keyboard for control purposes is limited The keyboard must be connected before switching the device on because the keyboard interface is initialised in the process of booting If the keyboard is plugged in while the device is running without having had the keyboard connected while booting it will not be functional ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 26 6 4 NETWORK CONNECTION RJ45 If the drivers required for functioning are installed on the device the control system may be integrated in an Ethernet network supporting the 10 100 1000Mbit standard by using the Ethernet 10 100 1000BaseT network connector Specifications of this network topology must be observed in this case You can install the drivers required for functioning from the enclosed service CD should they not be installed on the device SIGNAL NAME 108 1 TX d TX RX NC NC RX NC NC CO N O 0 A W N Note The device has two separately integrated network controllers of the Realtek RTL 8111c Family PCle Gigabit Ethernet type Note PXE booting is only possible by using the LAN1 port ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 2 6 5 SERIAL COM INTERFACE RS232 The serial interface is used for digita
8. temperature in order to avoid condensate accumulation Make sure to meet the permissible voltage requirements for this device After switching off and before switching on you must wait for at least 5 seconds Note The screen of a data cable must always be connected with the connector housing EMC Under the embedded operating system interfaces must explicitly be enabled and required drivers must be installed in order to be able to use them 4 1 AVAILABLE INTERFACES Note If the case is connected with earth potential at the provided PE contact e g by connecting the PE contact with the device plug the electrical insulation is no longer given This also applies if the device is installed by using a metal retainer clip If you want to have the device electrically insulated from the power supply you have to use a method of installation that ensures appropriate insulation 4 2 CHECK FOR OPERATIONAL READINESS Check the device for any hidden damage potentially caused by improper transport operating or storage conditions or by improper use or handling e g smoke development from the device etc If any damage is detected the device must be put out of service immediately and protected from accidental switch on ads tec GmbH Heinrich Hertz Str Le D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 18 5 OPERATION 5 1 FRONT CONTROL KEYS Depending on the device equipment version an operating system Windows
9. 8 8 SOFT KEYBOARD Here you can configure the soft keyboard application A large variety of settings like layout or commands can individually be adapted Softkeyboard General Layout Keys amp Macro Information Softkeyboard keyboard lanquage Colors Font amp Shade Hem Keys Auto detect language Background Keys Background Sequences Lock keys Start up and close v Chl Esc Ctl Activate by mouse not available w Ctrl Alt Del Alt Switch autologon available Y v Alt F4 AltGr 7 Alt Tab Softkeyboard position lin top of all other windows v A zc Unlock when closing not activated Y Restore Defaults Cancel Apply All changes must be confirmed by pushing the Save button 8 9 SCREEN MOB The Screen Mob application was developed in order to disable the touch screen of the device for a certain period of time This function can be used for cleaning the touch screen Touch screen disabled Remaining time 50 s ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 3 8 10 SOFT KEYBOARD INSTALLATION The soft keyboard must be installed from the enclosed service CD in order to ensure usability of the 5 keys except for the VMT series where you have 6 keys underneath the monitor The installation has to be carried out as described below e Plug in connector of external drive at the device e Switch on PC insert driver CD into drive after booting
10. AC Eingangsspannung Directive of the European Parliament and of the Council on the approximation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits Applies only for products with 50 1000V AC input voltage CE Kennzeichnung CE marking 11 Das oben beschriebene Produkt ist konform mit den Anforderungen der folgenden Dokumente The product of the declaration described above is in conformity with the requirements of the following documents EU harmonisierte Normen EMVIEnc EN 55022 2006 A1 2007 EN 55024 1998 A1 2001 A2 2003 EU harmonized Standards EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Sicherheit safety EN 60950 1 2006 A11 2009 Ort Datum Leinfelden Echterdingen 24 05 2011 Place and date of issue Name und Unterschrift Name and signature Quality Manager Manager Business Unit Data Systems Diese Erkl rung bescheinigt die bereinstimmung mit den genannten Richtlinien ist Jedoch keine Beschaffenheits oder Haltbarkeitsgarantie nach 443 BGB Die Sicherheits und Einbauhinweise der mitgelieferten Produktdokumentation sind zu beachten This declaration certifies the conformity to the specified directives but does not imply any warranty for properties The safety and installation documentation accompanying the product shall be considered in detail ads tec GmbH e Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 41 O
11. ODIFICATION All texts data and figures are non binding All these materials are subject to modification due to technological progress Our products comply with all provisions and requirements of the legislation at that point in time when the products leave our company premises The operator operating company bears sole responsibility for the compliance with any consecutive new technological development or adherence to any consecutive new legislatory provision as well as for the observance of their obligation as the operator operating company 1 4 TRADE MARKS We would like to emphasise that all names of hardware and software products used in this documentation as well as all brand names of corresponding companies are subject to the general copyrights of the intellectual property in terms of trademarks brand names and patents Windows Windows CE are registered trademarks of Microsoft Corp Intel Pentium Atom Core 2 are registered trademarks of Intel Corp IBM PS 2 and VGA are registered trademarks of IBM Corp CompactFlash is a registered trademark of the Compact Flash Association RITTAL is a registered trademark of Rittal Werk Rudolf Loh GmbH amp Co KG Any other national and international trademarks and product names shall hereby also be recognised 1 5 COPYRIGHTS This manual including all contained figures is protected by copyright law Any use of this manual by a third party in non compliance with the
12. PC6015 EG Konformit tserkl rung EC Declaration of Conformity ads tec Hersteller Adresse ads tec GmbH Raiffeisenstr 14 Manufacturer Address 70771 Leinfelden Echterdingen Germany Produktbeschreibung OPC 6015 Modell Model DVG OPC6015 xxx yy Productdescription XXX Ist eine fortlaufende Nummer zwischen 001 bis 899 und definiert die System Konfigurationen Is a continuous number between 001 to 899 and defines the System configurations yy Zwei unterschiedliche Buchstaben abh ngig vom Betriebssystem Two varying letters depending on the Operating System Das oben beschriebene Produkt stimmt in der von uns in Verkehr gebrachten Ausf hrung mit den Bestimmungen folgender Europ ischer Richtlinien berein The product described above in the form as delivered is in conformity with the provisions of the following European Directives 2004 108 EC Richtlinie des Europ ischen Parlaments und des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber die elektromagnetische Vertr glichkeit Anwendung trifft nur zu bei Produkten ohne Funk Kommunikation Directive of the European Parliament and of the Council on the approximation of the laws of the Member States relating to electromagnetic compatibility Applies only for products without Radio Communication 2006 95 EC Richtlinie des Europ ischen Parlaments und des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend elektrische Betriebsmittel zur Verw
13. Technical details chapter Note If the case is connected with earth potential at the provided PE contact e g by connecting the PE contact with the device plug the electrical insulation is no longer given This also applies if the device is installed by using a metal retainer clip If you want to have the device electrically insulated from the power supply you ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 22 have to use a method of installation that ensures appropriate insulation How to proceed if a PE system is used You must adhere to the following figure in order to ensure a correct installation of the PE system PE Aufbau PE mounting Linsenschraube M4x8 verz DIN7985 lens head screw M4x8 verz DIN7985 Z Scheibe 4 3mm Form A DIN 6797 lock washer 4 3mm Form A DIN 6797 U Scheibe B 4 3 M4 verz DIN 125 U washer B 4 3 M4 verz DIN 125 PE Kontakt PE contact U Scheibe B 4 3 M4 verz DIN 125 U washer B 4 3 M4 verz DIN 125 Z Scheibe 4 3mm Form A DIN 6797 lock washer 4 3mm Form A DIN 6797 ads tec GmbH Heinrich Hertz Str Le D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 23 6 1 SPEAKERS The OPC60xx is equipped with two internal speakers Note The volume can be set up by using the device front keys When activating the described key combinations the volume level is modified If the soft keyboard is installed the s
14. Version 2 0 User Manual e em lex MM va le tec wl e b PD 8 hi the rugged world of IT Stand 31 10 2014 Industrial PCs OPC6012 6015 2 Product Portfolio Tablet PCs IT infrastructure Terminals Industrial PCs Copyright ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen Germany ads tec GmbH e Heinrich Hertz Str Le D 72622 N rtingen acis tec Industrial PCs OPC6012 6015 3 INDEX About us met mh web et h wf et zb OO OO d OO P GAMM 4 1 4 2 SEENEN 5 Remarks occa eee ee sa se are een ieee eee tee Eee 6 Relevant documentation for the device cccccseesseeeeeceenseeeeeeensseeeseeesseeeeeoensseeeseoeseeessooenes 6 Explanation of used E le Le EE 6 Data figures and modification u ae 7 EE 7 OY NGS a ae ote se arene etre re cece cee ee steele aan aero 7 Environmenmal NEE 8 Elle E FE 8 Ge UU eu ne E H EEGENEN 9 Operating UV dote EE 10 Operating E E e EE 10 Damage due to improper TEE 10 WaN TED AUN E E E E 10 Treatment and disposal of lithium batteries uzau0000022an0000nnnnnnnnonnnnnnnnnnnnnnnnnnnnnn 11 IOUS OU Wer 1 E E EE E 12 MOUNINO ME 13 External Device Dimensions for OPC601 2 ccccccsesseecenseeeeenseeeeeesseeseenseeseonseeseonseessones 13 Installation Layout for OPC6012 uunuuennnnnaannannnnnnnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnn 14 External Device Dimensions for OPC6015 cccccseseeecee
15. be connected In this case you d have to ensure that the used device is suitable for industrial environments Warning Connecting or disconnecting external drives during operation is not admissible since it cannot be excluded that the drive might be in use while connecting or disconnecting it Data loss might result in the event of non compliance ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 29 8 SOFTWARE amp DRIVER INSTALLATION The device will be delivered with a pre installed Windows Linux operating system depending on what the customer wants The drivers required for this are already installed and the operating system will be enabled by entering the licence information Should an initial installation be required please follow the following steps With a newer operating system like Windows XP the network card and graphics card will properly be recognised during the initial installation so that only the touch screen driver and the soft keyboard must be installed separately Note If the hard drive was formatted the operating system can be reinstalled by using one of the existing interfaces An external keyboard is required for installation 8 1 INSTALLING THE OPERATING SYSTEM The device does not have any integrated CD drive The installation of the operating system can therefore only be carried out by using the USB interface Procedure for installation e The
16. boot drive in the system Bios must be switched to USB in order to boot the device from the USB interface e Restart the device and insert a Windows CD e Install Windows and set up the basic data e With devices including touch screens the touch screen driver as well as the soft keyboard should be installed in order to ensure their full functionality With Windows CE 6 0 or Windows XP embedded a complete image can also be installed by using a USB stick ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 30 8 2 TOUCH SCREEN DRIVER INSTALLATION Note When installing the driver you ll have to take in account that the touch screen monitor is internally connected with the USB interface Touch screen monitor and PS2 mouse can be operated simultaneously The installation has to be carried out as described below Switch on PC and boot Access the service CD by using the Explorer and start the Installer file in the TouchScreen folder Follow the on screen instructions and acknowledge the licence terms and conditions Once the installer has completed the installation shut down the computer and restart it subsequently After restarting the touch screen monitor has to be calibrated If the driver does not automatically start activate the setup menu via Start gt Settings gt Control panel gt Elo Touchscreen Via the Calibration data menu calibrating the touch
17. endung innerhalb bestimmter Spannungsgrenzen Anwendung trifft nur zu bei Produkten mit 50 1000V AC Eingangsspannung Directive of the European Parliament and of the Council on the approximation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits Applies only for products with 50 1000V AC input voltage CE Kennzeichnung CE marking 11 Das oben beschriebene Produkt ist konform mit den Anforderungen der folgenden Dokumente The product of the declaration described above is in conformity with the requirements of the following documents EU harmonisierte Normen EMV emc EN 55022 2006 A1 2007 EN 55024 1998 A1 2001 A2 2003 EU harmonized Standards EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Sicherheit Safety EN 60950 1 2006 A11 2009 Ort Datum Leinfelden Echterdingen 18 04 2011 Place and date of issue Name und Unterschrift Name and signature Quality Manager Manager Business Unit Data Systems Diese Erkl rung bescheinigt die bereinstimmung mit den genannten Richtlinien ist jedoch keine Beschaffenheits oder Haltbarkeitsgarantie nach 443 BGB Die Sicherheits und Einbauhinweise der mitgelieferten Produktdokumentation sind zu beachten This declaration certifies the conformity to the specified directives but does not imply any warranty for properties The safety and installation documentation accompanying the product shall be considered in detail ads
18. eyboard installation WEE 37 ele Te TUE 38 Service and SUP DOM D 39 ads VOC 1 0 e GE 39 Bell ee Le le 39 CE conformity declaration cccssccsessccsnsecsesseccnseccesseenseecnseecenseeonseeoasssonsesseas 40 ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 9 ABOUT US ads tec GmbH Raiffeisenstr 14 D 70771 Leinfelden Echterdingen Phone 49 711 45894 0 Fax 49 711 45894 990 www ads tec com As a supplier of high tech equipment ads tec supports large enterprises and globally operating groups of companies with state of the art technology know how that is always up to date and delivery of comprehensive services in the area of automation data and system technology AUTOMATION ads tec puts entire solutions for automation into practice from the planning to the commissioning and has particularly specialised in manipulation and material manipulation technology DATENTECHNIK The Data Technology division develops and manufactures PC based solutions and holds a wide range of industrial PCs thin clients and embedded systems available SYSTEMTECHNIK ads tec has specialised in the adaptation and optimisation of operational systems and develops software tools to complement the offered hardware platforms ads tec GmbH e Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 6 1 REMARKS 1 1 RELEVANT DOCUMENTATION FOR THE
19. he Save button ads tec GmbH Heinrich Hertz Str Le D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 34 8 6 ON OFF PUSHBUTTON CONFIGURATION The ON OFF pushbutton configuration allows to change the behaviour of the ON OFF pushbutton REGULAR MODE The ON OFF pushbutton switched the device on and off P Power Button Configuration Configuration Current setting Normal Mode Description Power Button can be used to turn the YMT6 on and off Apply Cancel SECURE MODE The ON OFF pushbutton only switches the device on The switch off function is disabled P Power Button Configuration Configuration Current setting Safe Mode v Normal Mode Description Safe Mode Power Button can only be used to turn the YMT6 on Note If the secure mode is used the device can only be shut down by the software ads tec GmbH e Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 35 8 7 EXEMPLARY RFID APPLICATION The exemplary RFID application was developed in order to test the function of the RFID reader S ads tec RFID sample application for RFID reader No RFID reader found Note Function only for devices with RFID possible Note In the Interfaces section of the manual you can find more information about the topic of RFIDs ads tec GmbH e Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 36
20. he packaging e 1x device e 4 pin Lead through connector from Phoenix Contact e Service CD Optional delivery scope e Operating system ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 10 2 OPERATING INSTRUCTIONS This device contains electrical voltages and extremely sensitive components The manufacturer or a service partner authorised by the manufacturer should be consulted if you plan to make any modifications For this type of work the device must be switched off at the mains and the power lead must be disconnected Suitable measures for avoiding electrostatic discharge towards parts of the components when touching the equipment must be taken If the device is opened by an unauthorised person hazards for the user might arise and any warranty claim will cease General instructions e All users must read this manual and have access to it at all times e Installation commissioning and operation may only be carried out by trained and qualified staff e The security instructions and the manual itself must be observed by all persons who work with this device e Atthe location of use the valid guidelines and regulations for accident prevention must be observed e The manual contains the most important instructions on how to use this device in a safe way e Appropriate storage proper transport installation and commissioning as well as careful operation are prerequisites for
21. ich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 39 10 SERVICE AND SUPPORT ads tec and its partner companies offer your customers a comprehensive service and support which ensures availability of a fast and competent support with respect to all upcoming questions related to ads tec products or assemblies Since the devices manufactured by ads tec are also used by associate companies these devices might be configured in customer specific ways Should any questions arise with respect to these specific configurations and software installations they can only be answered by the system manufacturer For devices not directly purchased from ads tec we don t deliver any support The support is delivered by our associate companies in these cases 10 1 ADS TEC SUPPORT The ads tec support team is available for direct clients from Monday to Friday from 08 30 AM to 05 00 PM using the following phone number Phone 49 0 7022 2522 202 Fax 49 0 7022 2522 2602 Email support ads tec de 10 2 COMPANY ADDRESS ads tec GmbH Heinrich Hertz Str 1 D 72622 Nurtingen Germany Phone 49 0 7022 2522 0 Fax 49 0 7022 2522 400 E Mail mailbox ads tec de Home www ads tec de ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 40 11 CE CONFORMITY DECLARATION OPC6012 EG Konformit tserkl rung EC Declaration of Conformity ads tec Hersteller Adresse ad
22. ing signals are displayed e LED lights green The device is ready for operation Power ON e LED is off The device is switched off POWER OFF 5 4 TOUCH SCREEN The control system is equipped with a touch screen monitor The touch screen monitor is internally connected with the USB interface The driver software required for using the touch screen is integrated in the corresponding operating system or can alternatively be installed from the enclosed service CD ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 21 6 INTERFACES 6 1 INTERFACE SETUP COM1 4 3F8h COM2 Touch 3 2F8h 6 2 24V DC POWER SUPPLY The supply voltage is provided via a lead through terminal including a screw connection Phoenix Contact COMBICON MC 1 5 4 STF3 81 The figure shows the socket inside the device 1 PE bE bY 2 oV DC ee Ss 3 NC 4 24V DC Voltage tolerance e Input voltage 24 V DC 20 Current consumption The current consumption of this device depends on the equipment version e g if a heater or WLAN etc is installed e Switch on current 7A 1ms e Standby current consumption 0 25mA e Regular operation 1 3A without heater without any additional load on the USB ports and without delivering the 5V supply for the scanner Note The power supply can be protected with a slow blow fuse of up to 4A Note The typical power consumption of this device is indicated in the
23. international copyright law shall hereby be prohibited Any reproduction translation and electronic or photographic archiving or modification requires previous written agreement by ads tec GmbH In the event of non compliance you shall be obliged to compensate for damages ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 8 1 6 ENVIRONMENTAL CONDITIONS The device may be operated under the following conditions Failure to observe these specifications will terminate any warranty for this device Ads tec cannot be held liable for any damages arising due to improper use and handling e Temperature in operation 20 55 C for storage 30 60 C e Humidity In operation 10 85 without condensate For storage 10 85 without condensate e Vibration resistance Standard EN 60068 2 6 1G 10 150 Hz Additionally applies MIL STD 810F 01 2000 annex C figure 514 5C US highway truck transportation e Shock resistance Standard EN 60068 2 27 5 G with a half wave of 11 ms duration 1 7 STANDARDS This device complies with the requirements and protective aims of the following EC regulations e This device meets the test requirements for granting the CE sign according to the European test standards EN 61000 6 4 and EN 61000 6 2 e This device complies with the test requirements in accordance with DIN EN 60950 VDE0805 IEC950 Safety of Information Technology Equipment
24. l data transmission The RS232 interface can be connected by using a commercially available 9 pin SUB D cable Note Pin 9 of the serial interface connector can be used for additional switching of a 5V power supply e g for operating a serial barcode scanner The COM 5V switch in the service slot of the device must be put in the ON position in order to use this function A subsequent restart of the computer might be required in order to properly activate this function PIN NUMBER SIGNAL NAME 1 DCD RxD TxD DTR GND DSR RTS CTS oO oO N O oOo A W N RI oder 5V DC max 1 A Note This interface is not electrically isolated ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 28 7 DRIVES 7 1 HARD DRIVE FLASH SSD The storage medium is selected according to the customer requirements The following options are available for storage Flash SSD A Flash SSD with a storage capacity of at least 1GB is used Its capacity depends on the desired operating system and the additional programmes to be installed Note Recommendation for the choice of storage medium with a basic installation SSD Flash memory Windows CE 6 0 Windows XP embedded Hard disk Windows XP Professional 7 2 EXTERNAL DRIVES By default no drive for removable media CD floppy disk is integrated in the device Instead the system provides a USB interface to which an external drive can
25. nal keyboard ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 19 OCcCoOoocoe fas LL LE ofa ERDOODODODODO OB apononoonoonnM AAH A iam Alt HOW TO OPERATE THE SOFT KEYBOARD FROM VERSION 3 11 Activate and deactivate the soft keyboard for letter character input using the touch screen Switches numeric keys on and off Num only if numeric keys are visible Switching between different representations Alphanumeric keys Numeric keys gt Function key bar Soft keyboard representation zoom in ele Soft keyboard representation zoom out Note If a function is to be activated which requires pressing two keys at the same time e g Alt F4 these keys have to be pushed one after another at the soft keyboard and the special keys Shift Alt and Ctrl must always be pushed first Due to differences in programming of a large variety of software we cannot ensure that the soft keyboard works properly with all software programmes When deactivating the soft keyboard the previously active state alohanumeric numeric keys or function keys will be stored and will be displayed when re activating the keyboard ads tec GmbH Heinrich Hertz Str Le D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 20 5 3 STATUS INDICATORS SYS LED BICOLOURED Depending on the colour and type of flashing different device states are displayed by the SYS LED The follow
26. nseeecenseeeeeseeeseenseeseonseeseoeseessonas 15 Installation Layout for OP COONS une ee 16 OMENS Si e e e EE 17 NIE E MENACES ae 17 Check for operational readiness un22a000000000nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nun 17 Operati nenne nenne ne nennen 18 FLONLCONILOL E 18 SON e I HE 18 STATUS MENU te ce ee ee ee een 20 WO UG TS CNC HE 20 ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 4 7 1 7 2 10 10 1 10 2 11 Ju at 21 mMer aCe SED tetera sie se scnetstcwni Se ceded E E 21 ZAV DC DOW CR DEE 21 SPEAKELS geed 23 USE COMO CUO e E 24 PS 2 e al e E 25 Network dee deit d E 26 Serial COM interface A ME 27 DIVES ora A E 28 Hard anve ER EE 28 XLS HIV CS an een 28 Software amp driver installation uu 2u00022000a200 n00nanunnnnunnnunnnnunnnnunnnnnnnnunnnnn 29 Installing the operating system BE 29 Touch screen driver Installation ee een 30 Configuration Center ccccccssssnssseeeecceeecnnnsseeeeceeeecnnasseeeeeeeeconnasseeeeeeneoonasseeeeeeeeooonssseeeees 31 Automatic brightness adaptation EE 32 USB LOCK e Te EE 33 ON OFF pushbutton CONfiQuratiOn ccceeeeesscceseeneeeeeeseeceessnseeeeeeeeooeassseeeeesseooensneeeeees 34 Exemplary RFID AD DNC AU ON aecstesaniceccnsicvecncasensenssissweussanauennerscecssunssesexeneccsaviweesssxecdssnseuedsetreensat 35 BOI OVO Ai E 36 STEEN Nees 36 Soft k
27. only ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 11 2 4 TREATMENT AND DISPOSAL OF LITHIUM BATTERIES This device contains a lithium battery for supplying the system clock with power as long as the supply voltage is not connected The battery has a life cycle of 3 5 years depending on which load is applied Note The more the battery is exposed to higher temperatures the faster it ages Warning There is an acute risk of explosion should the wrong type of battery be used Warning Do not put lithium batteries into a fire do not solder on the cell body do not recharge them open them short circuit them do not reverse their polarity or heat them up over 100 C dispose of them properly and protect lithium batteries from direct sun light humidity and condensation Lithium batteries may only be replaced by the same type or by a type recommended by the manufacturer The lithium battery must be disposed of according to the local legislation at the end of its life cycle ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 12 2 5 NOTES ON SAFETY Warning Installation works at the device are only permitted if the device is disconnected from the power supply and protected from accidental switch on Note Always adhere to the safety measures applicable when handling components at risk of being destructed by electro
28. s tec GmbH Raiffeisenstr 14 Manufacturer Address 70771 Leinfelden Echterdingen Germany Produktbeschreibung OPC 6012 Modell Model DVG OPC6012 xxx yy Productdescription XXX Ist eine fortlaufende Nummer zwischen 001 bis 899 und definiert die System Konfigurationen Is a continuous number between 001 to 899 and defines the System configurations yy Zwei unterschiedliche Buchstaben abh ngig vom Betriebssystem Two varying letters depending on the Operating System Das oben beschriebene Produkt stimmt in der von uns in Verkehr gebrachten Ausf hrung mit den Bestimmungen folgender Europ ischer Richtlinien berein The product described above in the form as delivered is in conformity with the provisions of the following European Directives 2004 108 EC Richtlinie des Europ ischen Parlaments und des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber die elektromagnetische Vertr glichkeit Anwendung trifft nur zu bei Produkten ohne Funk Kommunikation Directive of the European Parliament and of the Council on the approximation of the laws of the Member States relating to electromagnetic compatibility Applies only for products without Radio Communication 2006 95 EC Richtlinie des Europ ischen Parlaments und des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen Anwendung trifft nur zu bei Produkten mit 50 1000V
29. screen monitor can be started and the crosses appearing in a succession on the monitor have to be pushed for calibration If the cursor position perfectly matches the touch point of your finger you can exit this control menu by pushing OK ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 31 8 3 CONFIGURATION CENTER CONFIGURATION The start page of the Configuration Center provides you with an overview of which ads tec applications are installed on the device Additionally you can start any of these applications from the Configuration Center by double clicking on it Configuration Center t amp 3 Se 3 CN o Automatic brightness Ignition Key Locking USBLock Power Button control Configuration Configuration RFID Sample Softkeyboard Screen Mob Application Information For configuration please double click an application INFORMATION In the Information section device specific data like the device type the firmware version and the serial number are listed The information you ll find here must be indicated whenever you need to contact the support department Configuration Center t Configuration Device YMT6 Serial Number A OO Board Revision 03194 C 00 DVG Number MT6015 065 44 44 00 Firmware Version 0 53 BIOS Version 0 50 ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 32
30. static discharges EN 61340 5 1 EN 61340 5 2 ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 3 MOUNTING 3 1 EXTERNAL DEVICE DIMENSIONS FOR OPC6012 ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen Industrial PCs OPC6012 6015 3 1 INSTALLATION LAYOUT FOR OPC6012 1 Ausschnittt im Schaltschrank ZZ 14 ads tec GmbH Heinrich Hertz Str Le D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 3 2 EXTERNAL DEVICE DIMENSIONS FOR OPC6015 ads tec GmbH e Heinrich Hertz Str 1 e D 72622 N rtingen 15 Industrial PCs OPC6012 6015 16 3 3 INSTALLATION LAYOUT FOR OPC6015 a Ausschnitt im Schaltschrank ads tec GmbH Heinrich Hertz Str Le D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 17 4 COMMISSIONING The power supply connection and interfaces of this device are installed underneath a protective cover This cover has to be removed in order to connect the power supply lead and the interface cables All supply leads and all required data leads have to be connected before commissioning All supply leads and all required data leads have to be connected before commissioning Warning The device must be switched off before connecting or disconnecting any cables in order to prevent damage to the electronics The device may only be switched on after acclimatising to the ambient
31. tec GmbH e Heinrich Hertz Str 1 e D 72622 N rtingen Ye Eiter
32. the darker the ambient light must be before the display brightness is changed to night mode And vice versa the closer the slider is put to the night mode position the brighter the ambient light must be before the display brightness is increased to the value set up for the day mode In order to save the changes you ll have to push either Save or OK ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 33 8 5 USB LOCK FUNCTION The USB lock function enables you to lock the USB ports if required and to avoid access by unauthorised people MESSAGING In the Messaging section you can set up whether a message should be output in the event that a USB port is locked or not Additionally the locking process can be logged in the event log PASSWORD PROTECTION In order to avoid any unauthorised access to the USB Lock programme the settings made can be provided with password protection In this case the settings can only be modified if the password was entered correctly USB INTERFACES The desired USB ports can individually be locked by using the Lock button zH USB Lock Feedback Show message when usb device was blocked a Write message to event log when usb device was blocked Password protection a Activate password protection For the current settings USB Ports r USB port rear outer r USB port rear inner ch USB port Front All changes must be confirmed with t
33. ystem volume is additionally displayed by a display bar Increase system volume Decrease system volume ads tec GmbH Heinrich Hertz Str Le D 72622 N rtingen Ye Eiter Industrial PCs OPC6012 6015 24 6 2 USB CONNECTIONS The USB interfaces are used for connecting peripherals with USB connection These interfaces comply with the USB 2 0 standard requirements PIN NUMBER SIGNAL NAME 1 VDC 2 D 3 D A GND Note The device supports a maximum of 8 external USB mass storage devices If a USB Flash SSD is integrated a maximum of 7 USB mass storage devices can be connected Note The USB interfaces can be individually locked by using the Lock USB software tool USB CONNECTION IN THE FRONT PANEL One USB interface can be accessed from the front The interface is located under a plastic cover underneath the display The cover has a tab on the right hand side which is used for opening The plastic cover of the USB interface must be returned in protective position after use ads tec GmbH Heinrich Hertz Str 1 e D 72622 N rtingen ET Eiter Industrial PCs OPC6012 6015 25 6 3 PS 2 CONNECTOR A keyboard can directly be operated by using the PS 2 socket connector PIN NUMBER SIGNAL NAME 1 Keyboard Data Maus Data GND 5V Keyboard Clock O a fF O N Maus Clock Note Since the timing of the integrated controller is specifically set up for cherry keyboards keyboards of this