Home
User Manual - Sütron electronic GmbH
Contents
1. 1 Switch off the power supply of the web panels and switch it on again es SU TRON a ILC 130 Starterkit AS OJIO at Wee Le eel Analog Input Figure 4 21 Visualization start page 4 17 S TRON Visualizing with the web panel 2 Click the Analog Input button to view the visualization of the analog input value ES STRON EEE ILC 130 Starterkit Analog Input Analog Input Value 10V ov Figure 4 22 Display of an analog input value Input_Analog variable 3 Adjust the starter kit potentiometer to modify the level of the bar graph 4 18 S SUTRON S TRON
2. The ILC 130 ETH has been started up successfully if the green FR LED is on 4 10 A 2 S TRON Visualizing with the web panel 4 4 WebVisit and parameterization of the visualiza tion project WebVisit is a software tool used to generate web pages With this software you can operate and monitor your automation project via a Java compatible standard browser The user interface of the web panel is defined here and process data from PC WorX is assigned to the graphic objects of the visualization e g buttons for I O com mands To make the introduction process easier a complete visualization project will be used see Chapter Loading and parameterizing the visualization project on page 4 12 The individual objects are assigned on the development computer The visualization is transmitted over Ethernet to the web server of the controller see Chapter Down loading the visualization project to the controller on page 4 15 The web panel browser accesses this data via the web server of the controller Only interpretation of this data allows successful visualization of the project To ensure that the program can be downloaded to the controller the computer must also be in the same network as the web panel and the controller see Chapter As signing the IP address of the web panel on page 3 6 4 4 1 WebVisit user interface For better orientation and navigation in WebVisit this section briefly describes the WebVi
3. c Dokumente und Finstellungen pyse04 Desktop 05 WP w isu File View Project ae Tools Window He Dial D FTP Download j SS SSS SS I m Connect Server 192 168 0 2 FN Anonymous login ILC_13 PxC_Lo IMasterf Quickst E FTP download for project c Dokumente und Einstelungenipyse04 Desktop QS WP Visualisierung ILC 130 Starterkit Quickstart prj Quickst E FTP download on target IP Adress 192 168 0 2 ee FTP download in target Folder flash I WAS OK For more informations read the ftpDowinload log file S C PROGRA 1 PHOENI 1 SOFTWAr 1 WebVisk FtpDownloadog bt Lee D tq Quic ks startte I Download Project CECE CEE CEE E ee EERE LEE BEE _ Came Figure 4 20 Downloading the visualization project 7 Close the window and exit WebVisit The visualization project has been downloaded to the I O controller The visualization can now be displayed via the web panel 4 16 A 2 S TRON Visualizing with the web panel 4 4 4 Web panel display If all settings have been made properly your web panel will display the visualization start page after a brief loading time This includes animated representations of LEDs which can be activated deactivated using the switches of the switch module A button can also be used to call another page of the visualization This page includes an an imated bar graph which represents an analog input value
4. Oper Suchen in E Vius ILC 130 Stater gt Ci Er Dateiname FrstSteps_ILC130 Dater Webi promet fies ped z Abbrechen eT a e Te ST ese ee Openenstingpeoiet ee D AG Figure 4 15 Open a visualization project The visualization project was loaded into WebVisit The left workspace shows the various project files 4 12 SUTRON Visualizing with the web panel 6 Double click the main teq file CRE WebVisit File Edit View Project Library Layout Tools Window Help D am eile 4 SG ex els 2 R main teq LT analog teq Bel mantec SSUTRON LA MsgBox teq nu a_0036040 git er A bar SuetronLago git a MasterPhoenix5_14_05 jar s lai FirstSteps_ILC130 ter ES ESNIE IER FirstSteps_ILC130 itq Figure 4 16 Activating the main teq file If all settings have been made properly you see the first page of your visualization project If an error message is displayed indicating that WebVisit cannot open the pdd csv file when opening the WebVisit project confirm the error message with OK Link the process data of the controller to the variables from WebVisit Proceed as follows 1 Open the Project gt Teq Configurations dialog box via the Project Phoenix Ad vanced menu item 2 Confirm any further error messages with OK 4 13 S SUTRON Visualizing with the web panel 3 Inthe dialog bo
5. 1 Right click to select the properties of the network environment My Network Plac es and afterwards the properties of your network card Open Explore Search for Computers Map Network Drive Network Connections BARRE BIC File Edit View Favorites Tools Advanced Help Show on Desktop m Rename gt x Search a Folders X Properties Address e Network Connections A Name Type Network Tasks LAN or High Speed Internet a Create anew MB Local Area Connecti LAN or High Speed Inter connection Disable 9 Set up a home or small Status office network Repair Change Windows Firewall settings Bridge Connections amp Disable this network device Create Shortcut amp Repair this connection Rename this connection Rename view status of this connection Change settings of this connection Other Places E Control Panel E My Network Places Figure 4 2 Network properties of the development environment 2 Inthe General tab select Internet Protocol TCP IP and click the properties button again 3 In the window that appears activate Use the following IP address 4 Use the following preliminary IP address for your development computer 192 168 000 001 4 2 A 2 SUTRON Visualizing with the web panel 5 The required subnet mask will be displayed automatically If this is not the case enter the following subnet mask manually 255 255 255 000 _ Lo
6. the target device 3 5 3 4 2 Assigning the IP address of the web panel 3 6 4 Visualizing with the web panel 4 1 4 1 Structure of the example project 4 1 4 2 Setting up the development environment 4 2 4 3 PC WorX and parameterizing the ILC starter kit 4 4 4 3 1 The PC WorX user interface 4 4 4 3 2 Loading and parameterizing the program 4 6 4 3 3 Downloading the program to the controller 4 10 4 4 WebVisit and parameterization of the visualization project 4 11 4 4 1 WebVisit user interface 4 11 4 4 2 Loading and parameterizing the visualization project 4 12 4 4 3 Downloading the visualization project to the controller 4 15 4 4 4 Web panel display 4 17 S S TRON Overall Table of Contents SUTRON Important Notes 1 Important Notes al gt 1 1 Symbols The symbols in this manual are used to draw your attention on notes and dangers This is the safety alert symbol It is used to alert you to potential personal injury haz ards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER This symbol is used to refer to instructions which if ignored or not carefully followed will result in death or serious injury WARNING This symbol is used to refer to instructions which if ignored or not carefully foll
7. to the machine itself or other property can arise from the use of this device The device fulfills the requirements of the EMC directives and harmonized Euro pean standards Any modifications to the system can influence the EMC behav ior 1 4 Target Group All configuration programming installation commissioning operating and mainte nance work in connection with the automation system must be performed by trained personnel only e g qualified electricians electrical engineers etc The configuration and programming personnel must be familiar with the safety con cepts of automation technology The operating personnel must have been trained in handling the controller and be familiar with the operating instructions The installation commissioning and maintenance personnel must have an education which entitles them to work on automation systems 1 2 S SUTRON Generally 2 Generally 2 1 Purpose of this quick start guide This quick start guide helps users starting to work with the web panel by visualizing a simple example project based on the ILC 130 starter kit This quick start guide explains how to Connect and start up the web panels Establish communication between web panel and I O controller Parameterize the I O controller Display an existing visualization project on the web panel It is assumed the user has knowledge and experience in the operation of PCs and Microsoft Windows op
8. your network administrator 3 5 S TRON Commissioning 3 4 2 Assigning the IP address of the web panel It does not suffice to define the target path to display the web visualization 1 To make sure that web panel and controller are in the same network follow the path and assign the IP address of the web panel e g 192 168 000 005 as well as its subnet mask 255 255 255 000 All addresses of the Network Settings have to be entered in the format XXX XXX XXX XXX Numbers smaller than 100 have to be filled up with leading zeros e g 192 168 42 1 gt 192 168 042 001 G SUTRON 085014003 Settings WA Activate Code and Logout after 10 min Network Settings Start URL below after 5 sec Update Exit TCP IP Info http 192 168 0 2 fe ee za Network Start DHCP Test Settings Settings Batchfile IP Address 192 168 000 002 Subnet Mask 255 255 255 000 Figure 3 7 Setting the IP address and subnet mask 2 Confirm with OK and return to the start screen Home gt Home gt Exit 3 Confirm the Save Registry to flash message with Yes 4 Perform a reset by switching off the supply voltage for a short time If you have stored a visualization project on the controller this project will be dis played after the reset 3 6 SUTRON Visualizing with the web panel 4 Visualizing with the web pa
9. SSS GS SUTRON User Manual Quick Start Web Panel with Micro Browser Part Number 80860 788 Version 1 Date 2011 10 07 Valid for Quick Start Web Panel with Version Date Modifications 1 2011 10 07 First edition This manual including all illustrations contained herein is copyright protected Use of this manual by any third party in departure from the copyright provision is forbidden No part of this manual may be reproduced trans lated or electronically or photographically archived or altered without the express written consent from S tron electronic GmbH Violations shall be cause for damage liability S tron electronic reserves the right to make any changes that contribute to technical improvement S SUTRON Overall Table of Contents Overall Table of Contents 1 WAVES OTA INNS nn ini ic 1 1 1 1 SYMBOIS E Ernst ras ae en dt sine dateeeey EA nt axel curated dan danses 1 1 1 2 Safety Notes cies okie aie cies Wade nage Rees 1 1 1 3 Intended Use stand sasaki ententes 1 2 1 4 Target Group iii 1 2 2 Generally Re pseu seneeteeterereagnee 2 1 2 1 Purpose of this quick start guide 2 1 2 2 Hardware software requirements 2 2 OS SORA ee ce eee teenie 3 1 3 1 Connecting the Device 3 1 3 2 Switching ON erasian iin edidaniclianenisieen 3 4 3 9 OPENER aeaa nee nn nl 3 4 BA BASIC S THINQS 2 25 Jeesizetes shaven decetaccceedh ese tele era fastete detente s Heawaeie eres 3 5 3 4 1 Assigning the start URL of
10. a protection class device For safe operation safety extra low voltage SELV in accordance with DIN EN 61131 must be used for the supply voltage Connector in the operating device 3 pin connector A suitable female connector strip is supplied Table 3 1 Pin assignment supply voltage Pin Designation Function 1 2 Low Noise Ground 2 OV Supply Voltage 0 V 3 24 VDC Supply Voltage 24 VDC mS NOTICE Damage Cables with finely stranded conductors with a minimum cross section of 0 75 mm 18 AWG and a maximum cross section of 2 5 mm 14 AWG must be used for the supply voltage IZ NOTICE Damage A separate conductor must always be provided for the protective grounding The conductor must have a minimum cross section of 1 5 mm 16 AWG and must be kept as short as possible DANGER Hazardous voltages Hazardous voltages can exist inside electrical installations that can pose a danger to humans Coming in contact with live parts may result in electric shock 3 1 S SUTRON Commissioning Use the following procedure to connect the device to the supply voltage 1 Strip approx 30 mm 1 181 off the outer cable sheath and approx 5 mm 0 197 off the wires 5 mm 0 197 30 mm 1 181 Figure 3 1 Preparing the cable 2 Fit the wires with wire end ferrules and connect the wires to the connector N Figure 3 2 Connecting the female connector strip 3 2 S SUTRON Comm
11. all PC based and embedded con trollers by Phoenix Contact This software combines individual hardware elements e g sensors actuators I O devices to form a complete automation solution Here it is defined which data is required during operation and how it is processed by the controller e g ILC 130 Thus PC Worx starts every visualization To make the introduction process easier a functional example program will be used see Chapter Loading and parameterizing the program on page 4 6 The individual elements are assigned on the development computer The program is downloaded over Ethernet to the controller see Chapter Downloading the program to the controller on page 4 10 To ensure that the program can be downloaded to the controller the computer must also be in the same network as web panel and con troller see Chapter Assigning the IP address of the web panel on page 3 6 4 3 1 The PC WorX user interface For better orientation and navigation in PC Worx this section briefly describes the PC WorX user interface The user interface consists of the following main components Menu bar toolbars main window and status bar The contents of the main window depend on the workspace Tool Bar Menu Bar Status Bar Main Window Figure 4 5 The PC WorX user interface The program contains several toolbars with different icons which enable frequently used operations to be executed quickly Alternatively these operat
12. cal Area Connection Properties Advanced Connect using E Intel 21140 Based PCI Fast Ethernet This connection uses the following items iv E QoS Packet Scheduler 4 Network Monitor Driver M E CES Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Uninstall M Show icon in notification area when connected M Notify me when this connection has limited or no connectivity Cancel Figure 4 3 Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Ouse the following IP address IP address Subnet mask Default gateway Obtain DNS server a Use the following DNS server addresses Preferred DNS server Alternate DNS server IP settings of the development environment 6 Confirm with OK and close all windows of the network environment Note the proxy settings of you PC web browser e g Internet Explorer 1 Open the LAN settings on the Connection tab of the Internet Options window 2 Disable the Use automatic configuration script checkbox Blank Page Windows Internet Explorer DER about blank Fi
13. e Edit View Favorite ol Favorites Blank Page lelp Delete Browsing History Ctrl Shift Del InPrivate Browsing Ctrl Shift P Reopen Last Browsing S Internet Options InPrivate Filtering InPrivate Filtering Settin General Security Privacy Conte Pop up Blocker SmartScreen Filter Manage Add ons To set up an Internet connection click Setup Dial up and Virtual Private Network settings Compatibility View Setti Windows Update Developer Tools Choose Settings if you need to configure a proxy Diagnose Connection Pri server for a connection ne Internet Options Local Area Network LAN settings LAN Settings do not apply to dial up connections Choose Settings above for dial up settings Local Area Network LAN Settings Automatic configuration Automatic configuration may override manual settings To ensure the use of manual settings disable automatic configuration C Automatically detect settings se automatic configuration script Proxy server Use a proxy server for your LAN These settings will not apply to dial up or VPN connections erver for local addresses Lan settings Enables you to change settings fa 7 100 Figure 4 4 Proxy settings of the Internet Explorer SUTRON 4 3 Visualizing with the web panel 4 3 PC WorX and parameterizing the ILC starter kit PC Worx is the common automation software for
14. erating systems Please refer to the documentation ILC 130 starter kit PC WorX and WebVisit to clarify any questions that are not dealt with here or when working on larger projects 2 1 S TRON Generally 2 2 Hardware software requirements Operating device TP57AT Micro browser version gt 1 5 15 122 24 V DC power supply and supply voltage cable Project environment ILC 130 STARTERKIT Phoenix Contact Art Nr 2988515 CD ILC 130 STARTERKIT Ethernet switch Phoenix Contact Order No 2891152 Ethernet patch cable cross over Phoenix Contact Order No 2744843 Development environment PC for configuration development computer with a CPU of at least 800 MHZ main memory of 512 MB minimum Java capable web browser e g Java Standard Edition SE6 or higher and 1x Ethernet TCP IP interface Windows XP version gt SP2 PC WorX Express WebVisit Basic Monitor keyboard and mouse The software can be downloaded as a demo version at www phoenixcontact com AX SW SUITE DEMO CD Order No 2985660 Please use Microsoft Internet Explorer 5 or later for software installation 2 2 SUTRON Commissioning 3 Commissioning 3 1 Connecting the Device The supply voltage is supplied via connector X1 Refer to the technical data for the permissible supply voltage of the operating device The device has reverse polarity protection In case of wrong polarity the device will not operate This is
15. ing steps can be called via menu items or predefined shortcuts The toolbars that are displayed vary depending on the workspace that is set When the mouse pointer is placed over an icon without clicking on it a tool tip ap pears The tool tip displays the name of the current icon In addition a short function description appears in the status bar 4 4 S SUTRON Visualizing with the web panel The workspace can be changed via the icons in the toolbar ae FER Activate IEC programming workspace Activate bus configuration workspace Activate process data assignment workspace Frequently used icons for compiling and debugging Make compile project corresponds to Build Make in the menu bar Switch debug mode on off Display project control dialog box 4 5 A 2 SUTRON Visualizing with the web panel 4 3 2 Loading and parameterizing the program The complete example program is available in compressed format as the FirstSteps_ILC130 zwe file at www suetron com support software 1 Save the FirstSteps_ILC130 zwe file on your PC e g under the default path for PC WorX Express C Program Files Phoenix Contact Software Suite Projects 2 Select the Open button in the message that appears PC WorX Express is started 3 Confirm the prompt asking whether the project should be extracted to the direc tory containing the zwe file with Yes if the file is to be extracted to this director
16. issioning 3 Plug the female connector strip onto connector X1 UNOG N gt N N S N A 2 N 5 F Figure 3 3 Female connector strip is plugged on 4 Secure the female connector strip in place with a screw type locking to prevent it from slipping out S SUTRON Commissioning 3 2 Switching On The web panel starts as soon as the supply voltage is connected The web panel is equipped with the Windows CE operating system suitable for the micro browser The micro browser uses the preset IP path IP address of the web servers and tries to display an HTML page 0 http 192 168 42 1 Figure 3 4 Display after startup A web visualization can only be displayed when web panel and web server of the controller are in the same network Please refer to Section 3 4 for information on ba sic settings 3 3 Operate The panel is operated via the touch function of the display by directly selecting the button that appears on the display IZ NOTICE Damage Pointed or sharp objects such as pens or fingernails can lead to irreparable dam ages of the touch screen Exclusively therefore use the fingertips or the aids indi cated in the technical data for the operation 3 4 S SUTRON Commissioning 3 4 Basic settings Data exchange between operating device and connected I O takes place over the standardized Ethernet interface The following parameters have to be assigned to en
17. nel 4 1 Structure of the example project The complete starter kit is supplied fully pre assembled Try out the starter kit straight away by connecting the mains cable to the power supply unit on the back of the board and to the 230 V AC supply voltage e Supply operating device and FL SWITCH with a voltage of 24 V DC e Connect the devices require for the example project TP57AT ILC 130 Starterkit FL SWITCH SFN 5TX with an Ethernet patch cable according to Figure 4 1 See device specific user documentation CD ILC 130 STARTERKIT or at www phoenixcontact com For additional examples of bus configurations programs and visualizations please refer to the software CDs for PC WorX and WebVisit or visit the Download Center at www phoenixcontact com for example Entwicklungsumgebung TP57AT IP Adress Stat SubnetMask con Editor 192 168 000 001 Subnet 255 255 255 000 IP 192 168 000 005 Subnet 255 255 255 000 ILC 130 ETH CAE yoy yy mal ee IP 192 168 000 002 SFN 5TX baa Subnet 255 255 255 000 Figure 4 1 Network structure of the example project 4 1 S TRON Visualizing with the web panel 4 2 Setting up the development environment After you have installed the device this section explains how to establish communi cation in the network between development environment and I O controller To do this proceed as follows
18. nt Bus Configurator Figure 4 11 Message window following BootP The IP address is now permanently stored on the I O controller Flash memory 4 9 S TRON Visualizing with the web panel 4 3 3 Downloading the program to the controller After you have loaded the program and parameterized the I O controller the program must be downloaded to the controller 1 Select Make from the toolbar 2 PC WORX Express FirstSteps_ILC130 FirstSteps_ILC130 A ILC 130 ETH 192 168 0 2 IP Settings Name Value E R Resource R STD_RES ILC130_3 uy Phoenix Contact S MI ILC 130 ETH 192 168 0 2 2 f E ade He INTERRIIS N rer nenea Figure 4 12 Downloading the program to the controller 2 If errors occur when compiling remove the errors and repeat the compiling pro cess until it is completed successfully Error messages must be removed Warn ing messages do not have to be removed The results of the compiling process are displayed in the message window together with details of the number of errors and warnings When downloading the program the desired configuration is transmitted and activated 3 Open the project control dialog and click on the Stop button Send the project by clicking the Send button The program is now in the main memory of the I O controller Check whether the controller is set to run mode In order to activate the program it is necessary to perform a cold restar
19. onne Extras 2 5 MBC 150 ETH 192 168 0 2 S R Resource R STOPES 11C130 3 S y INTERBUS 0 0 Wiera E unconnected Al IP PROFINET Configuration is checked Resource is checked STD_RES INTERBUS is checked ILC 130 ETH 0 0 0 Figure 4 8 Activating the bus configuration 8 Inthe bus configuration select the I O controller node in the example ILC 130 ETH 4 7 SUTRON Visualizing with the web panel 9 Select the IP Settings tab in the Device Details window 39 PC WORX Exp t 13 Hele Ede Yew Project Buld opine Extras 2 SE ILC 130 ETH 192 168 0 2 UP Settings R STOPES 1 C130_3 S hy INTERBUS 0 0 Wiera E unconnected ga QU 1 settings JIE Extended settings ff Communication fy CPU Service Eater E Bas ntertaces Dat a Di F IP PROFINET Configuration is checked Resource is checked STD_RES INTERBUS is checked ILC 130 ETH 0 0 0 41 buid Eno Wamings J Intos PLE Enow Print Bus Configurator For FL amp Figure 4 9 Selecting the IP settings of the I O controller 10 Enter the MAC address of the I O controller It is printed on the device and starts with 00 A0 45 PC WORX Exp ep 1x Hele Edt Yew poet Quid Onne Extras 2 S R Resource R STOPES 11C130 3 S y INTERBUS 0 0 Wiera vendor PhwentcContact D De
20. owed could result in death or serious injury CAUTION This symbol is used to refer to instructions which if ignored or not carefully followed could result in minor or moderate injury NOTICE This symbol and the accompanying text alerts the reader to a situation which may cause damage or malfunction to the device either hardware or software or sur rounding property Reference to source of information This symbol refers to detailed sources of information on the current topic 1 2 Safety Notes Read this manual carefully before using the operating device Keep this manual in a place where it is always accessible to all users Proper transportation handling and storage placement and installation of this product are prerequisites for its subsequent flawless and safe operation This user manual contains the most important information for the safe operation of the device The user manual in particular the safety notes must be observed by all person nel working with the device Observe the accident prevention rules and regulations that apply to the operating site Installation and operation must only be carried out by qualified and trained per sonnel 1 1 S TRON Important Notes 1 3 Intended Use The device is designed for use in the industry The device is state of the art and has been built to the latest standard safety re quirements However dangerous situations or damage
21. rver of the controller To download the visualization project on the I O controller proceed as follows 1 Download the project on the I O controller via the Project Download project menu item 2 Inthe Connect area set the IP address of the I O controller under Server 192 168 0 2 in the example 3 Click on Connect E Phoenix Contact Webvisit c Dokumente und Einstellungen pyse04 Desktop Q5 WP Visualisierung ILC 130 Starterlit Ouickstartaset x EE Ranuye bekis fom ob Import PPOs File ter Import Containers file ita s Project configurations Grid configurations Init Containers Init PPOs Guickst Generate HTML FTP Download Connect QE FR Anonymous login NO CONNECTION cts Gif to Bmp Server Alarming Trending Configurations gt Download VPI Applet Project info replace Haaa mel ss l Download project FTP Exit Cancel Figure 4 19 Downloading the project on to the I O controller and setting the IP ad dress 4 Click on Download Project 5 Confirm the Save changes to main teq message and the subsequent mes sage with OK The progress bar shows the transmission status 4 15 A 2 SUTRON Visualizing with the web panel 6 Confirm the message that appears once transmission is complete with OK IRS Phoenix Contact WebVisit
22. signation aaam Lo Phoenx Contact E Universal EP 1 Settings Ey Extended Settings Communication Aly CPU Service Edtor 3 Bus interfaces E Date si BootP Server deactivated BootP Server started successfully Won configured device MAC 00 A0 45 01 46 8C queries for its IP parameters via BootP Won configured device MAC 00 A0 45 01 46 8C queries for its IP parameters via BootP ETHERNET PROFINET You have entered an incorrect MAC address It has been automatically corrected Device Details You have entered an incorrect MAC address It has been automatically corrected 215 Bat Enoe J wamings J intos PLE Ema Pant bus Contigurator For Help press FL Figure 4 10 Entering the MAC address of the I O controller 4 8 GS SUTRON Visualizing with the web panel 11 Perform a cold restart for the I O controller To do this switch the supply voltage off and then on again after around 2 seconds The controller is temporarily assigned the IP address which is specified in the pro gram for the I O controller The following message appears in the message window in the Bus Configurator tab gt Configured device ILC130ETHL queries for its IP parameters via BootP The devi ILCLSOETH1 received its IP parameters IP Address 192 166 0 2 Subnet Mask 255 255 255 0 Defeult Gateway vie BootP N Buia Erow Warnings Infos PLO Enos Pa
23. sit user interface The user interface appears when WebVisit is started The main window is divided into two sections All open project files are displayed on the left hand side On the right hand side the graphic views for the open project are displayed and can be ed ited Menu bar RE Phoenix Contact WebVisit C Programme Phoenix Contact Software Suite 150 WebVisit Projects te__ Ea File View Project Library Tools Window Help Toolbar for graphic icons Di ca 10 pro ia es S 4 amp S x 66 a LT MsgBox teg 2 IMasterPhoenix5_14_05 jar Est ter test itq Project data Graphic views Toolbar Stature bar M mej seess a E eady Figure 4 14 WebVisit user interface 4 11 S TRON Visualizing with the web panel 4 4 2 Loading and parameterizing the visualization project The visualization project is available in compressed format as FirstSteps_ILC130 exe at www suetron com support software 1 Save the compressed WebVisit project web server project from the CD ILC 130 STARTERKIT to your hard disk FirstSteps_ILC130 exe Select the Open button in the messages that appear Extract the file to the project directory of your WebVisit installation Standard in stallation path C Program Files WebVisit Projects Visu_FirstSteps Start WebVisit Open the project FirstSteps_ILC130 prj file in WebVisit via the File Open project menu item
24. sure that the web panel is detected in the network e Exit the start display by clicking the Settings button 0 http 192 168 42 1 Figure 3 5 Start display You enter the menu Settings V 1 5 15 122 O SU TRON Settings W Activate Code and Logout after 10 min Start URL below after 5 sec http 192 168 0 2 Info Page Restore Save Test Settings OS Settings Figure 3 6 Menu window Settings Please note that the Code Activate button is disabled When you enable this but ton the menu window is protected with the password of the micro browser 3 4 1 Assigning the start URL of the target device In the menu window you can define the target path start URL for the micro browser The start URL comprises the IP address of the web server e g of an ILC and op tionally the HTML homepage that is to be opened e Now enter the IP address of the target device into the corresponding line of the display and the start HTML file of the project as follows http 192 168 0 2 entry html By default Phoenix Contact controllers are delivered with the preset IP address 192 168 000 002 When creating the HTML file WebVisit assigns the name of the homepage entry html by default The web panel must be in the same network as the controller Set IP address and 2 subnet mask accordingly Should you have any questions please contact
25. t Com NOs plete the sending by clicking on cold and close the STD_RES window 2 PC WORX Express FirstSteps_ILC130 Fle Edt view Project Buld Onine Extras 2 a f k 2 ER gt G Cm ad LA MER ee a E g FirstSteps_ILC130 A ILC 130 ETH 192 168 100 84 IP Settings E MN ILC1S0ETH192 168 100 84 ER Resource R STD_RESILCI30 3 D vendor Phoenix Contact E INTERBUS 0 0 D Designation ILC 130 ETH WB ti wi arajsr meo 1 D Functional description Inline Controller For Ethernet Networks With Unconnected D Device type PLCs D Device family ILCixx D Order number 2988803 _B Revision 01 3 00 D Station Name v D Device Name lt gt D Module Equipment ID D DNS PROFINET Device Name ILC130ETHI B mac Address EENE STEI Y tae Phoenix Contact D 1P Address 192 168 100 84 Universal D Subnetmask 255 255 255 0 D Default Gateway el IL 5 All ip Settings IE Extended Settings g Communication y CPU Service Editor 4 Bus 4 Required memory for Program Code 1588 bytes Required memory for Retain Data 0 bytes required memory for the Application Image 33200 bytes rredicted memory usage for Data 1700 bytes 41 Build Eros Wamings infos PLC Eros Print Bus Configurator 7 Figure 4 13 Project control dialog 38 0 C gt 2GB
26. x set the path under which you have saved the FirstSteps_ILC130 mwt PC WorX Express example project for the starter kit on your PC Project Buld Advanced r Phoen c PC WORX project settings MWT path fe Dckumente und Einstelungen pyseO4 Desktop QS WP Projekt ILC 130 Starterka Fiest FODCSV oan f Dokumente und Enstelungen pyse04 Desktop QS WP Projekt ILC 130 Starterkit x Figure 4 17 Path entry for the example project If the explorer cannot find the FirstSteps_ILC130 mwt file view all files in the Ex plorer 4 Select the FirstSteps_ILC130 mwt file and confirm your entry with OK Project Configurations Project Teq Configurations Project Applet Advanced Project Buld Advanced Project Advanced Project Phoenix Advanced Phoenix PC WORX project settings MWT path Browse CEE x Suchenin O Test le Ores D D FrstSteps_JLC130 e 0 Eve Frststeps LC 130 FrstSteps LC130 Vsu_FirstSteps_ILC130 Dateiname FustSteps_ILC130 Datetyp Webvisit roa files mt mme x Datename FratSteps_ILCT20 Datotyp ar Fies z Abbrechen Figure 4 18 Selecting the FirstSteps_ILC130 mwt file 4 14 A 2 S TRON Visualizing with the web panel 4 4 3 Downloading the visualization project to the controller After you have loaded the visualization project and parameterized it the next step is to download it to the web se
27. y Or select a different directory PC WorX Express extracts the file automatically 4 If PC WorX Express prompts you to overwrite layouts e g page layouts etc or bitmaps confirm this prompt with No to all Once PC WorX Express has un zipped the project it is available for you to view edit The following window appears dock r rech tne 0 2 6 COTE TONS TOFS dock B dod tmeciock tered ubie AND relation between an onboard input variable and a dock varu connected to an orboxd output varabio ONBOARD INPUT EITO INBOARD _OUTPUT_BITO vo Connecting an andog rout varuble with an analog otot warlable ror Arbo DORON AND Figure 4 6 PC WorX Express FirstSteps_ILC130 5 Select Extras BootP SNMP TFTP Configuration 4 6 S TRON Visualizing with the web panel 6 Activate the BootP_ Server active checkbox and confirm with OK PC WORX E oss FirstSteps_ILC130 B E MM ILC 130 ETH 192 163 0 2 S R Resource R STORES nC130_3 S INTERBUS 0 0 MBs ttenatzsrmeo s E unconnected IP PROFINET Configuration is checked Resource is checked STD_RES INTERBUS is checked ILC 130 ETH 0 0 0 gt ouis Eros Wamings Infor PLC Enon Print Bus Configurator 7 Figure 4 7 BootP settings The program information is set in the bus configuration workspace 7 Activate the Bus configuration icon in the toolbar Hele Ear yew project Bud
Download Pdf Manuals
Related Search
Related Contents
Heat Controller RADS-101J Vista User Guide, Version 1.11a OPTI DS1000I uninterruptible power supply (UPS) Thomson 40FZ5533W 40" Full HD Smart TV Wi-Fi White LED TV Crate Amplifiers EXCALIBUR GX-2200H User's Manual 2 - Instructions Manuals GABARITO OFICIAL APÓS ANÁLISE DE RECURSOS 01 D 02 C 03 APEX2 Quick Guide1 - Datamax Copyright © All rights reserved.
Failed to retrieve file