1. IRONIC Communication Ports If you want to use several of these functions at the same time one simply adds the value E g Value 5 transmits P84 P387 and P388 via broadcast Parameter 165 196 RS485 addresses 1 32 Menu Communication RS485 Unit N Accuracy 1 Default setting 0 Password level 1 Parameters 165 196 define the serial numbers of the slave inverters connected If the parameter is set to zero 0 it defines the end of the list of slave inverters If you are interested in setting up this form of communication please load the instructions for the Ethernet browser from the CD supplied or download them from www solutronic de 11 2 Ethernet and web server With the help of a PC you can use the Ethernet link 5 to control the inverter via a web browser or SOLPLUS If you connect your inverter to a network and configure it you can call up and read out data from your inverter via any PC connected to the network Parameter 110 113 IP Adress of the inverter Menu Comunication Unit Accuracy 1 Default setting 192 Password level 1 Parameter 110 113 define die IP Adress of the inverter Parameter 114 117 Subnet mask of the inverter Menu Device Configuration Unit Accuracy 1 Default setting 255 Password level 1 Parameter 114 117 define the subnet mask of the inverter If you are interested in setting up this communication so you can find the instructions on t
2. O O 3 Ground bl n Labelling on the assignment port side of the connector X4 L L Pi SP80 120 User Manual_A1_EN 2014 04 24 doc S B LUJ energy 11 29 IRONIC Connections of the Inverter 4 1 Degree of protection IP 65 The IP 65 degree of protection rating means the inverter is suitable for semi outdoor installation To ensure that this degree of protection is complied with please observe the following The cover of the inverter must ever be closed and its seals intact Penetrations not in use must be sealed with suitable tight connectors or dummy plugs They are enclose in the scope of supply Open the inverter only in dry environment take place Blind caps MC 4 Connector seals Tyco MC 4 Inverter connector Suitable connector or dummy plug DC X1 X2 X3 DC PV String connectors for connectors Multicontact PV BVK4 32 0716 DC PV String connectors for connectors Multicontact PV SVK4 32 0717 DC PVString f for connectors connectors n and 1394739 1 AC X4 The mating connector is supplied with the inverter type Wieland RST 2515 96 051 4554 3 M12 X6 X7 The dummy plug is supplied with the inverter e g Phoenix Contact SAC 4P MS RJ45 X5 The dummy plug is supplied with the inverter e g Harting Han 3A RJ45 SP80 120 User Manual_A1_EN 2014 04 24 doc S o LUJ energy 12 29 IRONIC Operating the Inverter 5 Operating the Inverter 5 1 Switching the inverter on and o
3. SOLPLUS 80 SOLPLUS 100 and SOLPLUS 120 1 2 More Information More information on how to operate your new inverter can be found on the accompanying CD and on our download page at www solutronic de The CD contains the following documents and software SP100 SP120 Installation Instructions DimenSOL dimensioning tool program for designing SOLPLUS installations SOLPLUS communication software for the PC and user manual Instructions for master slave network yield monitoring Instructions for Ethernet browser SOLPLUS inverters have been developed manufactured and tested with great care and incorporate the very latest technology Our manufacturing procedures are in accordance with the stipulations of ISO 9001 If you encounter any problems or have any questions please do not hesitate to get in touch with us 1 3 Abbreviations The following abbreviations are used in this manual SOLPLUS Read out and monitoring software for use with all Solutronic inverters DC Direct current direct voltage electrical value on the input side of the inverter AC Alternating current alternating voltage electrical value on the output side of the inverter PV Photovoltaic Generator Generator interconnection of several solar modules to form a string or a number of parallel strings IGBT Insulated gate bipolar transistor EMV Electromagnetic compatibility Password level 1 measured value cannot be changed Password level 1 client Password
4. or Restart in progress Constantly lit red Fault in at least one phase of the inverter If the LED on the inverter lights up red or red green read up the fault description in the Installation Instructions manual or note down the warning alarm fault message indicated on the display and contact your fitter It is best if you read out all the data supplied by the SOLPLUS inverter the last fault displayed fault memory data logger and list of all parameters SP80 120 User Manual_A1_EN 2014 04 24 doc S o LUJ energy 14 29 IRONIC Using The Display 6 Using The Display 6 1 Functions of the controls The inverter has an LCD display that is used to monitor and set the main values This enables the operator to display important values and control the inverter even without a PC the AC side Display Button navigation field The operator uses the 5 button control element to navigate through the menu Specific values can be displayed changed and stored with the aid of these 5 buttons see table below Individually settable values are protected by a password to prevent them from being changed accidentally The display itself has 4 lines each consisting of 20 characters During normal operation the display is inactive It switches itself on for 10 minutes if one of the following situations occurs e The inverter switches itself on because the voltage across the solar generator has increased to the extent that the elec
5. ccccccccceeeeeeeeeeeeseeeeeeseeeeeeseeeeeeeseeeeeesaeeeeeseeeeeesseeeesseaseessseeeessaeeees 19 9 1 Reading out yield data on the display cccccccccssscecesececeseeecseeceeseeseseeseaeeeseaeeensueeeneeeeens 19 IA UDES e ee ere ee eee ene ee eee a a 21 9 2 1 AV e e E ese see E ep esters syed E tae E ce aetesaie AAE eee cseee cutee 21 9 2 2 aaeeeo i A se acca E A E E E A A A oy dacet reeset neeces 21 923 Anua energy 1OQGCN ssassn peaa sara 22 10 Main MenU a annnennsnnnennnnnnnnnnnrrsnrnerrsnrrsrnsrrnrrrsnrrnrrsnrrrrrnnrrsrrontrnrrnrrsnirnnranrnnrrnninnrrnrnnrrnnnrn ereenn 22 10 1 Setting PALAMECHETS cc ccccecccccssscecceeeeccceseeeceeseecceaseeecsugececeeeeeeseseeessageeessaueeessageeesssaeeeeess 22 11 COMMUNICATION Ports ccccceeeceeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeesseeeesseeeeeeseeeeeessaeeessaeeeeeseaeeeesaeeeeesaneeees 23 1 Communicating with several inverters by means of the master slave network 05 23 2 Ethernet And web SOPVe cccccccccsesecceeeeecsececeueeesesecceaseessaeeeseecenesenesageeeseeessaeeessaesenseeeens 24 3 SOLPLUS communication SOPWALE cccccceececeeeeeeeeeeeeeeeseeeeeeseeeeeeseaeeeessaeeeeeseeeeesaeeeeeas 24 12 Data EOC ON piace tice seat zn eee wicca cf a clr aka al Se ite ct tbc E cedar ean 25 12 1 Resetting to default SettingS ccccceccccsseeccsesececeeseeecseseeecseuseecseaeeeessageeessagseesssaseeessageees 26 13 Other Palani ler S sieaa ER
6. intermittent tone when an alarm is given The inverter generates a continuous tone as long as the inverter is suffering from a fault and is deactivated If the cause of the fault is no longer present the continuous tone stops being emitted The inverter generates an intermittent tone when an alarm is given The signal generator is always Off Parameter 147 Device class Menu Development Unit pee Accuracy 1 Default setting 120 Password level 4 Parameter 147 displays the inverter model Model designation 80 SOLPLUS80 gt Z o SOLPLUS 80 SOLPLUS 100 SOLPLUS 120 SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 26 29 IRONIC Maintenance and Cleaning Parameter 148 Serial number Menu Configuration Unit oa Accuracy 1 Default setting 0 Password level 4 Parameter 147 displays the serial number of the inverter At the same time this parameter serves as the address of the inverter in the network This value must be set accordingly in the SOLPLUS program Parameter 271 Display parameter Menu Configuration Unit Accuracy 1 Default setting 0 Password level 1 If you set parameter 271 to a value that is not 0 the parameter with this parameter number will be constantly displayed on the third line in the basic start screen of the display Example You want to see the value of parameter 8 Energy today displayed constantly on the display without having to press a button To
7. level 2 installer Passwort Level 3 Safety Passwort Level 4 Master SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 4 29 IRONIC Notes about The User Manual Solutronic Energy GmbH Kuferstrasse 18 D 73257 Kongen Tel 07024 96128 0 Fax 07024 96128 50 info solutronic de www solutronic de 1 4 Symbols used in this document Please read and observe the following safety instructions in this manual The danger classes describe the risks of non observance of the safety instructions The safety instructions describe the following danger classes per ANSI Attention denotes a warning that if not observed can result in property damage AN Caution Caution denotes a warning that if not observed can result in personal injury AN Warning Warning denotes a warning that if not observed can result in death or serious injury Danger denotes a warning that if not observed will result in death or serious injury he S Useful information and tips to help you operate the SOLPLUS inverter to best effect SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LU energy 5 29 IRONIC Safety 2 Safety 2 1 Safety in general Please read the following safety information and instructions before you put the SOLPLUS inverter into operation for the first time in order to avoid personal injuries and or property damage These instructions must be complied with at all times Do to attempt to install or p
8. you return to the base window The main menu is accessed by pressing the arrow key to the right Before entering the main menu the password is requested The sequence A gt V A gt VPA up right down up right down confirmed with OK enters the main menu Inside the main menu you could modify in several submenus the desired parameters By pressing the left key you return to the base window The actual value menu could be accessed by pressing the arrow key left It is separated into four menu groups Inside you could access several parameters By pushing the arrow key left again you reach the following menus At the end you get back to the base window more information on the display menu can be found on the CD and the download section at www solutronic de Actual value menu te Actual value menu Actual value menu for ner A nere SC amp lt q VieLDWoNTTOR SP80 120 User Manual_A1_EN 2014 04 24 doc Basic configuration SOLPLUS 35 PAC 3416 W grid feed mode Menu Y Basic menu 7 Basic menu energy today 0 0kWh energy total 0 0kWh amount euro today 0 0 amount euro total 0 0 firmware version 1 29 SPP Address 2 IP 192 168 0 99 11 56 17 time 15 12 2011 data slave data P i installation data pe J SOLU ners IRONIC Password request Press key combination and i E o Enter password 4 5 Confirm with OK Ie ae Main menu Main me
9. 5 B 4 3 Ground bl 11 1 Communicating with several inverters by means of the master slave network The master slave network is used to network several inverters in an installation For this purpose all inverters are connected in parallel by means of ports X6 6 and X7 7 X6 and X7 interconnected so use 1 1 cables with M12 plug in connectors which you can purchase from Solutronic through your fitter If you make up the cables yourself all you need to connect up are terminals 2 RS485 A 3 Ground and 4 RS485 B One of the inverters in the installation is defined as the master The display of this master inverter then shows the most important data of the slave inverters The master also records and displays the current power levels and the yields of the slaves Parameter 164 RS485 master Menu Communication RS485 Unit a Accuracy 1 Default setting 0 Password level 1 Parameter 164 defines whether this inverter is assigned at the master Bedeutung Inverter is not defined as master 0 The unit is RS485 master and sends every 10 seconds the parameter 84 Power reduction 1 2 The unit is 485 Master and evaluates the phase error bit Supply imbalance of the various slaves If grid imbalance detected this bit is sent to the slaves 4 It is sent P387 Voltage extern and P388 Cosinus Phi extern every 10 seconds via broadcast to the slaves SP80 120 User Manual _A1_EN_ 2014 04 24 doc S o LUJ energy 23 29
10. E E E E E E E EE E 26 14 Maintenance and CIaning ccccsssccccceseccccesseecceseeecsaseeecseseeeseugeeecsaneeecseaseeessageesssageeesseaes 27 14 1 Cleaning the Cooling INS sss icici char E E E a 27 14 2 GCIEANING the display sie aetsnwanaesesiansunavvce nner n E EA E EE EER ERER 27 15 Display navigati n SOLPLUS 30 120 oscusesecssucasiewanmaivansndasuaecoceadwunecbddmehduvanwtaduvedeateumedesbwemesueel 28 15 1 FeS Or UNS MA OI G aan a TE E E E E bees 29 SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LU energy 3 29 IRONIC Notes about The User Manual 1 Notes about The User Manual Thank you for deciding to buy a SOLPLUS inverter from Solutronic Energy This manual describes how to user your SOLPLUS inverter Please keep it somewhere where you have ready access to it whenever you need to Please comply at all times with the safety precautions we refer to in this manual In order to keep the description short the section on communication deals mainly with the details of display communication For all other means of communication reference is made to the relevant manuals You can carry out all parameter settings described here using the respective means of communication available Note The password level of the safety relevant parameters has changed from FW 2 65 Please refer to the current parameter list which is available on the website SOLUTRONIC 1 1 Scope This User Manual applies to the following Solutronic inverters
11. SOLU 7ersv IRONIC Solutronic Energy GmbH Kuferstrasse 18 D 73257 Kongen Fon 49 0 70 24 9 61 28 0 Fax 49 0 24 9 61 28 50 www solutronic de SOLPLUS 80 120 User Manual SOUL POUS SOLPLUS 80 SP120 User Manual Firmware 1 45 RS 2014 04 Version A1 Subject to change without prior notice Contents SOLPLUS 60 120 User Manual tcatencenaaciuenatewvandsueniacdatasdused siascued wasn suseetacssadneecsase RAEE VOE eE 1 1t Notes ADOUC The User Manual bixcdstescxedsass cavdenie leat ri aE aa eueitwes tose aai a aieea 4 si R E E P T T E E T TT ETS 4 L Morc NaN a a EE E E E AE O E EE ate oeseannsuee 4 To ADO VI ON er E E A T E 4 t4 Symbols sed in this document asirasi a A E 5 Be NY E penta ec ec E E A A A A T A A E E E E E ee 6 21 Salety MOA A aacsetestaccnte erect otal tne is Rectan ses acetaetanniaiodaseeusdsdiee centtenadteseanaaderteeenasseaeu eben 6 22 i 810 216 BU Loy amp epee ene er ee eee ane en ern E E ee ee een eee ene ener eee eee 6 23 NSD MNS IC CONN Sys es sae te cece dba a cttw NEE ERA E E AENOR 6 2 4 Non observance of this User Manual cccccccceecceeeeeeeeeseeeeesseeeeeeseeeeeesaeeeeesaeeeeeeaeeeeeesaaeeeeas 7 ee Mm 2012 a e a E E a a e e er eee ne ee ree 8 2 5 1 Explanation of the symbols used on the nameplate ccccscccceeceeeeeeceeeeseeeeseeeessees 9 3 INOU O e E ne ene EA ort ae E e E E e E eee 10 4 Connections of the Inverter ccccccsccccsssseecce
12. arge period S N 0938 0001 SP120 IP 65 MC4 PAG 3416 W MAC 0021EC050001 grid feed mode Menu SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LU energy 9 29 IRONIC Introduction 3 Introduction Each SOLPLUS inverter features a number of interfaces and communication ports via which the data of the inverter can be read out A total of approximately 300 inverter parameters can be read out The data provided by the inverter are divided into the following categories 1 Yield and display values These values represent the instantaneous values of the inverter They are actual values and display values that cannot be altered 2 Setting values These are values that can be set and altered individually Depending on the importance and meaning of the parameters these values can be set by the end customer the fitter or the utility company For security purposes different password levels are incorporated SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 10 29 IRONIC Connections of the Inverter 4 Connections of the Inverter SOLPLUS 80 120 DC connections Tracker 1 X1 6 M12 RS485 X6 DC connections Tracker 2 X2 M12 RS485 X7 DC connections Tracker 3 X3 8 Additional PE connection 3 AC grid connection X4 9 DC isolator ctheret X Connection label plug X4 view on Pin assignment of X6 and X7 the port side of the connector X4 br 12 V 1 O OC 2 RS485 A wh bk RS485 B 4
13. arising from faulty installation of the inverter Among these consequences are e Damage to the display and keyboard foil deterioration of readability e Fading of the print on the housing the look of the housing deteriorates Therefore chose the place of installation for the inverter so that the device is not directly or indirectly exposed to UV radiation e The device must not be exposed to direct sunlight e The device must be protected from reflections by glass facades or PV modules 2 4 Non observance of this User Manual Solutronic Energy shall accept no liability for damages resulting from non observance of the warnings given in this User Manual Read the operating maintenance and safety instructions before you put the device into operation for the first time If you are not able to understand the language used in this documentation sufficiently please contact and inform the supplier of the situation Trouble free and safe operation of this inverter presumes proper professional and workmanlike transportation storage mounting and installation as well as careful operation and thorough maintenance SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 7 29 IRONIC Safety 2 5 Nameplate You can identify the model of your inverter by looking at the nameplate The nameplate which carries the precise type designation of the inverter is located on the right hand side of the housing The example below shows the namep
14. bination lock If you now want to change parameter settings of the inverter proceed as follows Enter the customer password to open the main menu Enter your access code under parameter 267 Change the parameters you want to change Deliberately enter an incorrect access code under parameter 267 As long as parameter 267 is set to 0 values can not be changed It is not possible to read out the numbers entered as access code 1 You must therefore make a note of these numbers and keep them safe If however you do happen to forget or lose these numbers the inverter can only be re enabled again by the manufacturer In this case Solutronic will provide you with a special code that will enable you to reset the access code SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 18 29 IRONIC Reading Out Yield Data 9 Reading Out Yield Data 9 1 Reading out yield data on the display The inverter is equipped with an integrated energy meter that calculates and adds up the energy fed into the mains power supply The energy meter of the inverter deliberately indicates a value approx 1 5 lower than that actually fed into the grid The purpose of this is to ensure the inverter does not indicate to you the owner a value that is higher than that recorded by the calibrated export meter of your power supplier In the basic start screen press the VW button to display the basic menu The basic menu displays the followin
15. d buttons to change the value of the digits After entering the desired value press x to confirm it You will find the entire menu navigation tree in the Appendix 7 Checking The Default Settings After switching on the inverter the first time please check that the date day of the week time language and credit payment settings are correctly set 7 1 Setting the date and time Parameter 97 Date Menu Device Configuration Unit Accuracy TT MM JJJJ Set today s date under parameter 97 Parameter 98 Time Menu Device Configuration Unit Accuracy hh mm ss Set the instantaneous time under parameter 98 SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 16 29 IRONIC Password Protection 7 2 Setting the language Parameter 99 Language Menu Device Configuration Unit Accuracy Default setting 0 Password level 1 Set the language under parameter 65 Use the following values 0 German English 6 Turkish o O 7 3 Setting the credit payment value Parameter 29 Compensation Euro per kWh Menu Yield Control Unit a Accuracy Default setting 0 Password level 1 The default setting ex works is the credit sum valid for rooftop installations in Germany at the time of delivery 8 Password Protection Parameter 37 Password request and password level Menu Unit Accuracy 1 Default setting 0 Password level 1 You password is saved under th
16. do this set parameter 271 to the value 8 14 Maintenance and Cleaning Check at regular intervals that your SOLPLUS inverter is functioning properly If the heat sinks become soiled e g through dirt or dust we can no longer guarantee that the heat that arises inside the SOLPLUS inverter is properly dissipated Such soiling and inadequate heat dissipation has a very negative effect on the performance output service life and safety of the inverter Do not open the inverter There are no components inside the inverter that can be maintained or cleaned by the end user 14 1 Cleaning the cooling fins The surface of the inverter housing can become hot when the inverter is in operation Very hot Do not touch Switch the inverter off before you clean the cooling fins Caution the inverter requires at least 5 min to discharge Clean the cooling fins using a suitable brush 14 2 Cleaning the display Never use a caustic abrasive or solvent based cleaning agent If the display is difficult to read due to dust or dirt use a damp cloth to wipe it SP80 120 User Manual_A1_EN 2014 04 24 doc S O LUJ energy 27 29 IRONIC Display navigation SOLPLUS 80 120 15 Display navigation SOLPLUS 80 120 Base window by pressing a button the display turns on and the main screen appears The basic menu is accessed by pressing the down arrow key on the display In the basic menu the yield values can be read By pressing the arrow key left
17. eseeeceeseeecseseeceuseeessaueeecsagseeeseaseeessaeessegeeesssaseeeenes 11 4 1 Degree of protection IP 65 wise wewciis icc cciisa iadactiemetnatdunsedavawanenudaien sodastienintienldindusjenticlvasudlachivanenaddamcndeuisiete 12 5 Operating the Inverter oa idiesiecrds setornerenittion dudarencaitenaitcienveia lduniedadeivundpalsdlun ada seleuweinatiadaddansintionadactiomnspasdsiaeatoauds 13 5 1 Switching the inverter on and Off siccosescsavesvensacnsueaseuesedadsartraue idee niniin Kaiia aR aatia 13 S2 821 raS GS eee ee ee E E EE E N 14 O USN TOOD PIA een EE E EE E EAEE 15 O1 Foncions ONE CONTOS seses E E EEEE E 15 OZ Using TIS CISDIAY COMMONS sererai eE a Ea e EEANN OREAREN 16 T Checking The Default SCUING Sriicescscscctnesenscetnnde scan seadacenntusughdawalindadasaedsoncneseuddavslauenieneasianinvinuatamedses 16 7 41 Setting the date and time cccccccecccccesececcseeeccseeeecseuseeceeaeeecsaueeecseseesseaseeessageeessaeeessaaees 16 7 2 Setting the lANQUAGE cccccccssseccceseeeceeececceeueeecseuececseuseeecsageeessueeecsaaeeesssseeessageeessageeesssaaes 17 7 3 Setting the credit payment value ee cceecccecseeeeceeeeeeeeeeeeeeeeaaeeeesaeeeeeeseueeeseeueeesaeneeesaeeeeesaess 17 9 Password OU COU reed cs cinne enna eee cote O ee EEEE EE oy ane ETE EEn EE 17 8 1 Customised protection of the inverter settings cccceccccsseseeeeeeeeeeeseeeeesseeeeeeseeseesaaeeessaaeees 18 9 Reading Out Yield Data ic
18. ff Only ever switch the inverter one or off by means of the DC isolator 9 Disconnect the AC side before turning off the inverter on the DC switch 9 The DC isolator can remain switched on during normal operation Never disconnect the DC plug connectors 1 3 while the inverter is operating The electric arc that would arise if you did could kill you or result in you suffering serious injury In the event of an emergency the inverter may also be disconnected from the DC voltage of the PV modules by means of the DC isolator 9 while the installation is up and running SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 13 29 IRONIC Operating the Inverter 5 2 Operating states The operating states of the SOLPLUS 80 SOLPLUS 120 inverters are indicated by means of a light emitting diode LED and on the display The LED has two colours and indicates the instantaneous operating state of the inverter The actual operating state is indicated on the display For the operating state to be identified the DC side of the inverter must be connected to the PV modules and a minimum voltage of approx 280 V must be input into the inverter SOLPLUS 80 120 display What the operating states means Explanation Display content Constantly lit Grid feed mode green Flashing green Initialisation or standby e g because the voltage of the solar generator is too low Flashing red green Fault has occurred
19. g parameters Parameter 1 2 and 3 Power L1 L2 L3 Menu Actual values Output Unit W Accuracy 1 W This parameter displays the amount of power instantaneously being fed into the grid by the individual trackers Parameter 231 232 and 233 UDC 1 2 3 Menu Actual values Input Unit Volt Accuracy 1V This parameter displays the instantaneous DC voltage of the modules of the individual trackers Parameter 234 235 and 236 DC current 1 2 3 Menu Actual values Input Unit A Accuracy 1A This parameter displays the instantaneous DC current of the individual trackers Parameter 8 Energy day Menu Actual values Yield monitor Unit kWh Accuracy 0 001 kWh Default setting 0 Password level 2 This parameter displays the amount of energy generated by the inverter on a particular day SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 19 29 IRONIC Reading Out Yield Data Parameter 12 Energy total Menu Actual values Yield monitor Unit kWh Accuracy 1 kWh This parameter displays the total amount of energy generated by the inverter Parameter 27 Euros today Menu Actual values Yield monitor Unit Euro Accuracy 0 01 Euro Default setting 0 Password level 2 This parameter displays the yield i e the amount of money generated by the inverter today Parameter 28 Euros in total Menu Actual values Yield monitor Unit Euro Accuracy 0 01 Euro Default setting 0 Password level 2 Th
20. he enclosed CD or at www solutronic de 11 3 SOLPLUS communication software SOLPLUS is Solutronic s evaluation program for SOLPLUS inverters e Connection to the inverter via Ethernet analogue modem GSM modem and RS485 e Configuration of the inverter e Reading out of the various files that the inverter supplies list of all parameters fault memory annual energy logger etc e Display of the yields in clearly laid out graphics e Display of the data logger in clearly laid out graphics e All parameters can be read out Simple operator control and a Help function make it possible to monitor how your PV installation is functioning and its yield SP80 120 User Manual_A1_EN 2014 04 24 doc S O LUJ energy 24 29 IRONIC Data Logger If you are interested in using SOLPLUS to scan your inverter please load the program and the instructions for installation and use of SOLPLUS from the CD supplied or download them from www solutronic de 12 Data Logger You can record up to 8 parameters in the data logger You can chose which recording interval you want We recommend that you use SOLPLUS to display the parameters recorded Parameter 130 Data logger cycle Menu Data Logger Unit min Accuracy 1 Default setting 5 min Password level 1 The longer the data logger clock pulse you set the longer the recording time of the data logger and the less precise the temporal resolution of the data Parameter 133 140 Data logger
21. is parameter When operating the inverter from the display the password is always AP V AP V when operating via a PC the password is always the serial number of the inverter You have to enter the password in order to open the main menu of the inverter or to be able to change parameter values on the PC There are other passwords that enable the fitter or utility company to make safety relevant settings Fitters have to request these passwords from Solutronic SP80 120 User Manual_A1_EN 2014 04 24 doc S O LUJ energy 17 29 IRONIC 8 1 Customised protection of the inverter settings To protect the inverter and its parameter settings against unauthorised changes it is possible to assign an access code to the inverter This is especially important if your inverter is accessible via a modem or the internet Since the password for parameters of password level 1 is the serial number of the inverter anyone could change your parameter settings You can prevent this from happening by setting the following parameter accordingly Parameter 267 Access code 1 Menu Device Configuration Unit Accuracy 1 Default setting 0 Password level 1 As long as parameter 267 is set to 1 values can be changed If you enter a number between 1 and 65535 for parameter 267 access to the inverter will in future be blocked and no changes will be able to be made without first entering this number under parameter 267 again This parameter acts like a com
22. is parameter displays the total yield i e the total amount of money generated by the inverter since it was installed Parameter 122 Maximum power level today Menu Actual values output Unit W Accuracy 1 W This parameter displays the maximum power level fed into the grid today Parameter 123 Operating hours today Menu Actual values Inverter Unit h Accuracy 0 1 h This parameter displays the length of time the inverter has already been switched on today The meter starts running as soon as the solar generator delivers an adequate voltage Parameter 124 Operating hours total Menu Actual values Inverter Unit h Accuracy 0 1h Default setting o Password level 4 This parameter records and stores the total length of time the inverter has been switched on since it was first started up SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 20 29 IRONIC Reading Out Yield Data Parameter 7 Efficiency Menu Actual values Inverter Unit Accuracy 0 1 This parameter displays the current level of efficiency of the inverter This value is calculated from the DC voltage and DC current A value calculated manually on the basis of the AC and DC data may differ from this value due to measurement tolerances Repeated measurements have confirmed that the value displayed under this parameter is very accurate Parameter 70 71 72 Temperature inverter L1 L2 L3 Menu Actual values Inverter Unit C Acc
23. late of a SOLPLUS 120 The nameplate of the SOLPLUS 80 100 has exactly the same layout Nameplate of a SP 120 L 4 www solutronic de infogsalutronic de DC Eingang AC Ausgang DC input AC output Max Eingangsspannung Nennspannung Frequenz Max input voltage Nominal voltage frequency 3 x 850 V AC 3 x 230 400 V 50 Hz Betriebsspannungsbereich Nenn Ausgangsleistung Operating voltage Nominal output power 3 x 345 750 V 12 000 W Max Eingangsstrom Max Ausgangsstrom Max input current Max output current 3x 13 2 A 3x 18A Selbsttatige Freischaltung Automatic disconnection device Netzgekoppelter On grid Solarwechselrichter inverter Made in Germany Made in Germany S N 0938 0001 SP120 IP 65 MC4 MAC 0021EC050001 SP80 120 User Manual A1 EN 2014 04 24 doc SOLU energy IRONIC 8 29 Safety 2 5 1 Explanation of the symbols used on the nameplate The nameplate provides the following information Attention Hot surfaces A Attention and danger Ce X Observe the operating instructions Waste Electrical and Electronic Equipment WEEE Solar inverters must not be disposed of with household waste Please return the device to Solutronic after it has reached the end of its useful life Attention The inverter may still carry voltage even after it has been disconnected from the PV installation and grid Please be sure to wait until the capacitors have fully discharged disch
24. ly yield for every day of the year The inverter is equipped with a memory that stores the yield for 365 days This memory is cyclical i e after a year it overwrites the old values stored Use the and lt buttons to scroll through the months and the A and WY buttons to scroll through the days 10 Main Menu You can change the parameters of the inverter in the main menu In the basic start screen press the button and then The values that can be changed are protected by a password The password for end customers is always the following button combination A gt V A gt Y Then confirm by pressing Gr In the main menu mark the submenu items you want using the V or A button and select by pressing OK e Input Output Menu e Inverter Menu e Safety Menu e Grid Monitoring Menu e Communication Menu e Options Menu e Data Logger Menu e RS485 Addresses Menu e Monitoring Menu 10 1 Setting parameters In the submenu mark the parameters you want using the V or A button and select by pressing E9 Mark the individual digits in the parameter using the or lt button Use the V or A button to change the value of the digits After entering the desired value press to confirm it SP80 120_User Manual_A1_EN_2014 04 24 doc S O LUJ energy 22 29 IRONIC Communication Ports 11 Communication Ports Ethernet X5 6 M12 RS485 X6 M12 RS485 X7 Pin assignment of X6 and X7 br 12 V 1 2 RS485 A wh bk RS48
25. nction has been started and successfully ended see chapter entitled Yield monitoring Alarms Contains a list of the last 6 alarms These are stored in the sequence in which they occurred with date and timestamp The above files can be read out using SOLPLUS Solutronic Energy GmbH Kuferstrasse 18 D 73257 Kongen Tel 49 0 7024 96128 0 Fax 49 0 7024 96128 50 info solutronic de www solutronic de SP80 120 User Manual_A1_EN 2014 04 24 doc S O LUJ energy 29 29 NQRONIC
26. nu Device Configuration fee J k Safety p k k e 2 _ Power Reduction P J Reactive Power P Communication P Datal a atalogger gt 1 k Maintenance gt T _ Yield Control b J es af 28 29 Display navigation SOLPLUS 80 120 15 1 Files of the inverter The inverter generates various files which can be generated and read out via one of its communication ports more t Fault memory Contains the fault memory a list of the last 100 faults These are stored in the sequence in which they occurred with date and timestamp List of all parameters A table showing all the parameters of the inverter with parameter number parameter name parameter value and unit p Fala can be changed je L eean e values of the nce Annual energy logger A table in the form of a ring memory endless loop memory about the preceding year with the achieved yield of each respective day in 0 1 kWh Configuration of data A description of the configuration contents of the data logger logger with the estimated storage times Installation monitoring A list with the yield values of the master irradiation sensor and all slaves as well as the yield values of the master sensor and all slaves relative to the connected nominal DC output This list is in the form of a ring memory endless loop memory and has been created over the course of the preceding year It cannot be read until the integrated yield monitoring fu
27. parameter 1 to data logger parameter 8 Menu Data Logger Unit Parameter numbers Accuracy 1 Default setting 1 Password level 1 Default setting ex works o 133 Parameter 1 DL Power output L1 Parameter 1 DL Power 133 Parameter 1 DL Power output L1 L1 137 Parameter 5 DL Power output L5 Parameter 5 DL Power output 137 Parameter 5 DL Power output L5 134 Parameter 2 DL Power output L2 138 Parameter 6 DL Power output L6 135 Parameter 3 DL Power output L3 139 Parameter 7 DL Power output L7 432 Parameter 4 DL Power output L __ 3 Parameter 8 DL Power output L8 In the default setting 3 parameters are stored per clock pulse This means that around 5 000 data entries can be recorded in the ring memory in a 5 minute cycle clock pulse before the memory is overwritten by the new data In the case of a 5 minute clock pulse and 14 hours of sunshine per day the data logger is full after roughly 89 hours and begins overwriting the first data entries stored these entries should therefore be read out before they are overwritten Possible settings The 8 parameters available can be used to configure the content of a data logger line as desired The minimum parameter number in each case is 0 the maximum number 254 Please refer to the Appendix for the parameter numbers Note that the list of parameters from 133 to 140 begins with values that are not zero The first entr
28. tronics are being supplied with power e One of the buttons is pressed The backlight of the LCD display switches on for 2 minutes when a button is pressed 10 minutes after the last time a button has been pressed the display is deactivated SP80 120 User Manual_A1_EN_ 2014 04 24 doc S o LUJ energy 15 29 IRONIC Checking The Default Settings 6 2 Using the display controls The basic start screen is displayed when the display is switched on Pressing one of the menu control buttons will call up the menu assigned to it Displays the yield data of the inverter in kWh and You can also call up the data of the slaves and of the installation as a whole via this menu control button Press lt to return to the basic start screen Displays the 3 AC phases of the inverter in detail Press to return to the basic start screen Displays the 3 DC trackers of the inverter in detail Press Ok to return to the basic start screen Open the password entry box that gives you access to the main menu Enter the customer password A gt V A P VW and confirm by pressing Qk Press lt to return to the basic start screen In the main menu mark the submenu items you want using the V and A buttons and select by pressing In the submenu mark the parameters you want using the V and A buttons and select by pressing Qk Mark the individual digits in the parameter Use the and lt buttons to select the digits and the A an
29. uracy 1 C This parameter represents the current inverter temperature in the respective module Parameter 13 14 and 15 Mains voltage L1 L2 L3 Menu Istwerte Ausgang Unit VV Accuracy 1V This parameter displays the instantaneous grid voltage of the phases connected Parameter 148 Serial number Menu Configuration Unit oe Accuracy 1 Default setting Password level 4 This parameter displays the serial number of this inverter You require this serial number to set up a master slave network and configure SOLPLUS In the event of a fault message alarm you need to tell the fitter this serial number 9 2 Submenus You open the various submenus by marking the relevant entry in the basic menu and pressing 9 2 1 Slave data In a master slave network you can display the most important data of the slaves on the master Scroll through the slaves using the and lt buttons Prerequisite for this is that you have defined this inverter as the master and entered the addresses serial numbers of the slaves See section 11 1 Communicating with several inverters by means of the master slave network 9 2 2 Installation data In a master slave network you can display the most important data of the entire installation on the master The same prerequisites apply as for 9 2 1 SP80 120 User Manual_A1_EN 2014 04 24 doc S O LUJ energy 21 29 IRONIC Main Menu 9 2 3 Annual energy logger The inverter records the dai
30. ut the SOLPLUS inverter into service until you have read through all the documentation supplied thoroughly Read through these safety instructions and all other user instructions and tips before you begin work with this device If you sell on hire out or pass on this device to someone else in some other way make sure that you give the new user these safety instructions too 2 2 Intended use This device must be used only for the purpose described in this User Manual The inverter is designed for use in grid connected photovoltaic installations All safety regulations must be complied with All installation work must be carried out precisely as described in this manual No modification of any kind to or in this device or to its external wiring is permitted Any such modification could lead to serious safety problems and danger to life and limb 2 3 Safety instructions AN Warning Improper use of these devices non observance of the warnings given in this manual and improper tampering with the safety functions can lead to property damage personal injury electric shock and in extreme cases death The surface of the inverter housing can become hot when the inverter is in operation Very hot Do not touch High voltage due to incorrect connection Risk of fatal or bodily injury from electric shock SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LU energy 6 29 IRONIC Safety Solutronic Energy is not liable for the consequences
31. y that is 0 means the end of the logger list The data logger of the inverter now creates files every day which the inverter saves to guard against loss in the event of a power failure After you have changed the configuration of the data logger you have to delete the entire data logger memory You do this by setting parameter 66 Set default values to the value 70 Delete data logger SP80 120 User Manual_A1_EN_ 2014 04 24 doc S O LUJ energy 25 29 IRONIC Other Parameters 12 1 Resetting to default settings Parameter 66 Set standard value Menu Configuration Unit Accuracy 1 Default setting 0 Password level 1 Possible settings If you set parameter 66 to the value 10 all parameters covered by password level 1 Customer are reset to their default settings delivery status To enable this function you have to set password level 1 Customer beforehand If you set parameter 66 to the value 70 the values recorded in the data logger will be deleted To enable this function you have to set at least password level 1 Customer beforehand 13 Other Parameters Parameter 45 Function signaller Menu Maintenance Unit or Accuracy 1 Default setting 0 Password level 1 The inverter generates an intermittent tone as long as the inverter is suffering from a fault and is deactivated If the cause of the fault is no longer present the intermittent tone stops being emitted The inverter generates an