Operating instructions Door Station Stainless Steel -

image

Contents

1. 6 Slide in the inscription label carrier again At the same time position the inscription label with your finger Lo 7 Release the call button To do this press in the plastic key slightly and turn it clockwise until the call button is released from the lower position 8 Lock the call button To do this turn the plastic key clockwise again until it engages 9 For function test press the call button the call button is correctly locked when e the call button cannot be pressed in deeply and e an acknowledgement tone is heard when the call button is pressed If the call button is not correctly locked please repeat step 8 Opening Door Station Stainless Steel E i The included opening tool is required for opening the Door Station Stainless Steel 1 Turn the lower fastening bolt s with the opening tool to Open Single column door stations have one lower fasten ing bolt double column door stations have two lower fastening bolts The position of the fastening bolts is shown via small recesses on the lower side of the front panel A Take care with plastered walls With repeated opening of the door station with plastered walls the opening tool may damage the plaster 2 Lift the front panel from the lower attach
2. 602 0 Fax 49 0 21 95 602 191 www gira de info gira de GIRA 10 41 09 22 20 11
3. be connected to the multi function input _3 of the stainless steel door station s built in loudspeaker via the included connec tion cable The push button then has the same function as a call but ton and can therefore be used for example as a call but ton or for controlling a switching actuator Replacing inscription label Inscription labels For labelling the Gira Door Station Stainless Steel use only Gira inscription labels The transparent plastic labels are non fading weather resistant and wrinkle free With the included release code inscription labels for the first labelling are available free at www marking gira com 1 Unlock the call button with the enclosed plastic key twist the plastic key anti clockwise until it engages 2 Engage the call button press the call button firmly inwards by approx 1 cm Y The call button engages and stays in the pressed position 3 Grip under the glass cover with the flat side of the plastic key and twist out the inscription label carrier AN Do not remove the inscription label carrier Do not lift and remove the inscription label carrier 4 Remove the existing inscription label and slide the new inscription label into the inscription label carrier until it stops 5 Position the inscription label underneath the clips of the inscription label carrier
4. Installation and Operating Instructions Door Station Stainless Steel 2501 20 2502 20 2503 20 2504 20 2506 20 2508 20 RA 2509 20 2510 20 2512 20 Table of contents Device descripta re han nee are ol pees ohana ee ee rem 5 Installing Banel bOxs creta da e o to et ee e do de ds 6 INStallg front Panel is e e as ata 8 A ILL eae ean 9 MUulti f nctiominputsz sa SE le HE 9 Replacing inscription label 2a tie de ee idea 10 Opening Door Station Stainless Steel s2ssssnsssnnnnnsnnnnnnnnneennnrnnen nn 12 Operation la ats er ent er 13 Techniealidata a Kaiser Br Es ee 14 W rrantyas Asien E E E wend 14 Device description The Door Station Stainless Steel is a pre assembled vandalism protected door station for the Gira door communication system The front plate of high quality V2A stainless steel with a thickness of 3 mm is especially robust The call buttons are also made of durable stainless steel The illuminated inscrip tion labels are covered by a fully secured and flameproof glass plate The inscription labels can be opened via a covered mechanism and can then removed from the front Both the call buttons and inscription labels are uniformly illuminated with a white power saving LED element Loudspeaker and microphone are located behind the respective sound openings and are water resistant and vandal proof Wall anchors included Panel box Lo
5. cking plate Plastic bracket Catch strap hook Front panel Loudspeaker cover Microphone Name plate Call buttons SOON ODOARWN N Installing panel box max 20 mm IN Attention Installation and mounting of electrical devices may only be carried out by a qualified electrician 1 Select a suitable installation site and chisel an opening in the wall 2 If necessary mount the included wall anchor Note the following information when mounting the panel box e Ensure installation position is correct note the TOP labelling The panel box must be installed level With the later mounting of the Door Station Stainless Steel there is no possibility for correction The panel box must be installed as flush to the sur face as possible It must be ensured that the locking plate can be flush mounted later Maximum plaster compensation is 20 mm 3 Plaster in the panel box to be flush with the final surface maximum plaster compensation 20 mm 4 Mount the included plaster protection 5 Plaster the wall 6 Carefully remove the plaster and take out the plas ter protection Installing front panel 1 Insert the locking plate flushly into the panel box i Insert locking plate eve
6. ment 1 and pull it at an angle downwards from the upper attachment retainers 2 Operation Volume setting ERE 1 Systemprogr 3s Qu 2 o M Meier Sl The second person accepts the door call at the home station A INN Initiating a call ringing 4 o M Meier Sl g Systemprogr M Meier Y 1 Nu The volume can be set separately at each door station The volume setting must be made by two people Press the Systemprogr button on the control device for 3 sec to start programming mode Briefly press a previously assigned call button at the door station via receiver or speech button and starts speaking Briefly press the call button again at the door station Volume changes during the voice connection when the button is pressed There are four volume levels in total The next highest volume is set with each button press When he loudest volume level is reached the next button press sets he quietest volume level Ending the voice connection The most recently set volume level is saved in the door sta ion 6 Briefly press the Systemprogr button on the control device o exit the programming mode Press the call button to trigger a call tone at the assigned home station The button press is confirmed by an additional acknowledge ment tone If the conversation is accepted by the home statio
7. n the micro phone opening is illuminated blue Switching light on in conjunction with a switching actuator Licht 1 Y Press the call button to switch on light or another device via an assigned switching actuator The button press is confirmed by an additional acknowledge ment tone Technical data Connections Protection type Operating temperature Dimensions W x H x D 1 gang 2 gang 3 gang 4 gang 6 gang 8 gang 9 gang 10 gang 12 gang Warranty 2 screw terminals for 2 wire bus 2 screw terminals for additional supply 2 system bus connector strips 6 pole 1 video connector strip 2 pole 2 sabotage contact screw terminals IP 44 25 C to 70 C 140 x 198 x 40 mm panel box 160 x 218 x 3 mm front panel 140 x 265 x 40 mm panel box 160 x 285 x 3 mm front panel 140 x 332 x 40 mm panel box 160 x 352 x 3 mm front panel 250 x 265 x 40 mm panel box 270 x 285 x 3 mm front panel The warranty is provided in accordance with statutory requirements via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center Gira Giersiepen GmbH amp Co KG Elektro Installations Systeme Postfach 1220 42461 Radevormwald Deutschland Tel 49 0 21 95
8. nly The locking plate must not be twisted while being inserted into the panel box and must not be under tension Push the locking plate inwards until the plastic brackets touch the wall Fasten the locking plate with the 4 Allen bolts and locking washers included In order to guarantee a secure fastening of the front panel later the Allen bolts must be firmly tightened Fold out both lateral mounting retainers 1 slide the front panel of the Door Station Stainless Steel into the mounting retainers 2 and attach the catch strap of the front panel to the hook of the locking plate 3 Connect the 2 wire bus to the Bus terminals i Switch call button illumination off To permanently switch the call button illumination off remove the jumpers between BUS and ZV 5 Pull the front panel from the mounting retainers 1 and fold these in 2 6 Position the lower fastening bolt s of the front panel to Close I 7 Mount the front panel onto the guide bolts and press it on until the upper and lower fastening bolts E13 engage Starting up Once all of the devices door and home stations control device etc have been installed the door communication system can be started up Start up a door station is described in the system manual included with the control device Multi function input A mechanical push button can