Home

15" Plus – Operators Manual

image

Contents

1. 15 Plus Operators Manual Operatos supplemet to Two 16 manual Congratulations on choosing a Rainbow Colour Changers product We thank you for your custom Please note that this product has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements It is essential to know the information and comply with the instructions given in this manual in order to ensure the fitting is installed used and serviced correctly and safely Carefully read this instruction manual in its entirety and keep it safe for future reference Please hand this manual over if you sell or give this product to somebody else General m Rainbow Colour Changers products are intended for professional use and should only be used by qualified personnel or under their supervision Follow all cautions and warnings indicated on the unit After unpacking this product please check if the device is intact If this is not the case please contact the support service Rainbow Colour Changers An der Talle 26 28 D 33102 Paderborn Germany Phone 49 0 52 51 14 092 28 Fax 49 0 52 51 14 092 90 info rainbow colour changers de Installation Make sure all parts for fixing the colour changer are correct Make sure the fixture is stable before positioning the Colour Changer Do not fix this device on or near flammable surfaces Usage m This product is designed for indoor use only For
2. If the unit is over trimmed The RCC will try to wind on more filter than there is on the roll At the last frame stop the RCC by setting the Frame selector to 0 Turn the Range trim anti clockwise to pay out more filter and then use the Frame control to wind the filter onto the roll Repeat until the last frame is wound on to the roll 7 Apply a small amount of tension to the scroll This is performed by pushing and turning the gold inner knob anticlockwise whilst holding the Black outer knob 8 Move the scroll back to the zero point by setting the Mode to F and controlling the speed on the Frames switch 9 Set the zero position by pushing the Gold and Black knobs together and positioning the seam between Frames 0 and to align to the outer edge of the roll IO Set the scroll tension further by pushing the gold inner knob anticlockwise whilst holding the Black outer knob The correct scroll tension varies with different scroll lengths and it is best to recheck scroll tension at 5096 when the scroller has been set This can be done by setting the Mode to E the address to 050 and controlling the speed on the frames selector Approximately 6 turns will give the correct tension fora colour 15 scroll cont 5 Plus Manual 7 Revision Printed April 10 1997 FITTING THE GEL STRING continued II Move the scroll back to the full point by setting the Mode to D and controlling the speed on the Frames switch
3. O e es e es e es c o 6 6 o 6 C373 Address Mode Frame Mode F 00 Output for Zero Set Trimming Fades the output level to 0096 irrespective of control input This can be used when loading filter in to the colour changer without the need for a control console The Frame selector is used to control the speed of the crossfade as follows Frame Selector Speed 0 and 4 E Stop Slow 2and F Medium 3 Fast Example Medium fade to 00 A 5 A 5 A 5 o o o o 15 o e e N o e G e G e G e e b e b e b Address Mode 15 Plus Manual 21 Revision Printed April 10 1997 RAINBOW SETUP TEST MODES CONT NOTE Gel Position after Exiting Test Modes Upon exiting any of the test modes and selecting one of the operational modes between Oand 7 the PlusCard will check for a valid DMX input If none is detected the gel position will remain at the last valid position before entering test mode If a valid level is detected move the gel at medium speed until the position equals to the input position from when it will track the input as per the mode frame and address settings This will give a smooth crossfade to position avoiding any undue stress on the scrolls As the Rainbow Colour Changer also has a permanent memory the position memory is retained on power down On power up the PlusCard will go to either the value on power down No DMX input or will move the gel at mediu
4. cables which connect the Rainbows carry both power and data and should be rated for both The connection of the units is as follows POWERING THE UNITS Rainbow Colour Changers are powered by a 24V DC supply which is derived from a central power supply This can either be a Maxi combined Power Supply Splitter or separate power supply splitter combination Traditionally the PSUs have been rated in terms of the number of 8 RCC units which can be driven from one supply This does not apply to the larger Rainbows which take approximately twice the current of the 8 colour changer One 15 RCC counts as two units So a 24 unit PSU or a Maxi PSU Splitter can supply 24 x or 2 x or 4x This also applies to the other scrollers as follows 8 TWO I6 UNIT 8 ALFRESCO 1 5 UNITS 15 PLUS 2 UNITS 8 LITE 2 UNITS 20 INCH 2 UNITS Light Curtain 2 UNITS 5 Plus Manual 2 Revision Printed April 10 1997 MODE 0 STANDARD OPERATION Mode Frame 15 Plus Manual Mode 0 Standard Operation Continuous Gel Position With Mode O selected and the Frame switch set to zero the Rainbow operates as a standard DMX decoder with proportional control The user selects the DMX address for each individual Adaress The gel speed is set by the speed of control input and the Rainbow type The fan is controlled by the standard HI LO fan speed switch on the rear of the Rainbow colour changer using the thre
5. filter position and the fan speed of individual Rainbows in the rig with two sequential DMX addresses Three preset maximum gel speeds are available for up to 12 bit resolution on slow crossfades limited by console fade time Mode 3 Address nn Gel Position nnn Fan Speed Gelspeed Max speed Dependent on model no of Frames I5 RCC 4 5s Resolution As DMX 8 Bit Mode 4 Addressnn Gel Position nn Fan Speed Gel speed Medium Resolution Upto I2 bit Mode 5 Addressnn Gel Position nn Fan Speed Gel speed Slow Resolution T to 2 bit A 5 4 5 5 ES G ES c y G e 4 oC ol e SB or SB or amp 0 b 0 b 0 b Address ok Address Fan Speed Frame by Frame Mode d TY Frame by Frame Control can be selected in this mode Set the Frame go rotary switch to the number of frames excluding Frame 0 5 Plus Manual 12 Revision Printed April 10 1997 Mode Frame Mode Frame 15 Plus Manual FAST THREE CHANNEL OPERATION Mode 6 Fast Control of Position Gel and Fan Speed The fast control gives standard operation of the colour changer but with the Gel speed controlled by DMX address 510 and the Fan speed controlled by DMX address 511 This is designed for where the lighting operator needs overall control of the fans and scrolls but without the need to individually select each Colour Changer For example in rehearsal where the designer is mov
6. rear of the PlusCard The different profiles for an colour scroll are shown below The scrolling speed between full colours is set by the relevant mode selected in modes 0 to 5 the gel moves at the preset speeds for modes 6 and 7 the inter frame gel speed is controlled by a DMX address Selecting Frame by Frame Mode The l6 position Frame select switch is labelled 0 9 and A F where A 10 B II etc Where proportional position control is required select the switch to position O Frame by Frame off For Frame by Frame operation select the number of frames after frame O For example 2 Colours Frame Frame 4 l6 Colours lt 16 Colours Frame F The Frame by Frame software has been designed to include hysteresis and dead bands between colours typically 4 This avoids any unwanted repeated changes due to noisy analog signals 18 Revision Printed April 10 1997 MODES 9 TO F RAINBOW SETUP TEST MODES rainbow 15 Plus Manual The PlusCard is fitted with a suite of test routines and diagnostic systems in the software This ensures that whether on the bench or in the rig the status of the system can be checked and the performance tested by the user without the need for an external control system or expensive test equipment These tests are selected by setting the mode switch to the one of the following settings When a test routine is selected other attributes
7. remain unchanged unless altered but control from DMX is halted until an operating mode is selected Mode 9 Fan Drive Test The internal and external fan control can be tested by selecting fan levels on the Frames selector Mode A Reserved for Future Development Mode B Self and Functional Tests The PlusCard is fitted with full self testing for factory and service use which are summarised below For a full description of the features check the Pluscard technical manual Mode Frame Function Description B RAM Test Posn test Fades Gel Position Up and Down Fan Test Fades Int Ext Fans Up and Down Switch Test 1 Checks Sw 1 2 3 6 in Posn 9 Switch Test 2 Checks Sw 1 2 3 6 in Posn 6 Jumper Check Checks jumper settings externally DMX Signal Check Indicates Program Version in PROM Indicates Program Version in SRAM Indicates correct l C communication operation Download via PC link has priority RHT Link has priority toF Reserved for future use ODWPOANDUAWN O 19 Revision Printed April 10 1997 RAINBOW SETUP TEST MODES CONT Mode C Micro Set of Gel Position This allows the setting of the gel position using I 2 bit accuracy This can be used to check the Frame tables or set accurate positioning The 12 bit accuracy allows the scroll to be divided into 4096 steps These levels are used to set frame by frame positions and for the ultra smooth slow crossfades using on board speed control The filter movement is at a p
8. smooth o scrolling between colours and consistently guiet colour changes por irrespective of the limits of the incoming DMX control signal Where AiO ool required the processor calculates fades using 12 bit levels which oo NC avoids the stepping associated with 8 bit DMX signals This is especially sp critical for slow fades on long gel strings and larger colour changers 15 22 26 etc When using speed control the 2 bit fade resolution is only effective if the PlusCard fade time is longer than the control signal fade Where speed control is required from the PlusCard the best results will be achieved if the position channel changes with time 0 and the time information is sent on the separate channel If power is disconnected and reconnected to the Rainbow the PlusCard will hold the last good DMX value Once it receives a new valid level it will fade at medium speed to achieve this level When the gel position matches the input level the PlusCard resumes normal operation This prevents the colour changers racing to a level if the power or data is accidentally lost 5 Plus Manual 17 Revision Printed April 10 1997 FRAME BY FRAME MODE 15 Plus Manual In all operating Modes 0 7 the PlusCard can be set to only display full frames of colours stepping from colour to colour when the control input crosses standard threshold levels This is called Frame by Frame mode and is controlled from the Frame control on the
9. speed 3 Channel Control with Frame by Frame operation As with other modes Frame by Frame operation is selected by setting the frame length No of Frames on the Frame switch on the rear of the Rainbow All of the other features available with 3 Control are possible with only full frames of colour displayed 14 Revision Printed April 10 1997 MODE 8 CONTINUOUS OPERATION MODE Mode 8 Continous Fade Mode In situations such as exhibitions a continuously changing colour may be required This has normally needed a control console to give constantly variable control input to the colour changer This is a a zo costly solution and also limits the resolution of the fade to the 8 bits Me of DMX Mode 8 in the Pluscard allows the user to set up a smooth ott ys fade across the complete length of the Gel String whilst the Rainbow Pi puhati is only supplied with 24 volt DC power C To select this feature simply set the Mode Selector to 8 TIMING OF AUTOMATIC FADES The fade timing is controlled by the Frame switch Set the Frame switch to for the slowest fadetime and F for the fastest fadetime Setting the Frame switch to 0 stops the movement In order that many Rainbows may be synchronised to each other the Pluscard will reset to zero on power up After a preset time approx 25 seconds the continuous operation will start with all colour changers synchronised together FAN CONTROL DURING AUTO OPERATION W
10. the fitting to operate well and reliably it should not be used in humid environments The ambient temperature should not exceed 40 C 104 F or fall below 0 C 32 F Avoid any liquids or metallic items entering the unit m Ensure adequate ventilation and do not block or cover any ventilation slots in the device they guarantee the reliable functioning of the unit and protect it against overheating The scroller may only be used in its standard position which is 60 from horizontal The colour changer may only be put into operation with original Rainbow Colour Changer power supply units PSU Check that the mains frequency and voltage correspond to those for which the PSU is designed as given on the surface label of the PSU Refer to the manual about the max amount of scrollers to be connected Maintenance All service work should be exclusively performed by qualified personnel Do not dismantle the scroller or modify it yourself Before starting any maintenance work or cleaning the scroller remove the power from the PSU The surface of the device may heat up due to the luminaire used Please let the scroller cool down before touching it Rainbow Colour Changers GmbH disclaims all liability for damage to the fitting or to other property or persons deriving from installation use and maintenance that have not been carried out in conformity with this instructions manual which must always accompany the fitting Ra
11. 12 Use the Range Trim potentiometer to accurately set the end position of the scroll This position is correct when the final seam is aligned with the outer edge of the Rainbow I3 Set the Mode Frames switch on the PlusCard to the required setting The scroll is now correctly installed with a scroll and trimmed From experience we suggest that you i Run the colour changers end to end a few times This allows the filter to find its natural position on the spindle It will also show any noise problems due to badly made scrolls ii Where many units are to run together run the colour changers to 95 and confirm alignment of all units Retrim where necessary iii Check the scroll tension at 5096 control input Mode E Addr 050 FITTING A BARNDOOR TO THE FRONT OF THE UNIT The removable front panel is fitted with four wheels for fitting a rotatable barndoor The barndoor is fitted by rotating the top left wheel on its bracket and inserting the barndoor as below Screw A Step Loosen Screw A until the bracket rotates The screw is captive and will not come out Step 2 Rotate the bracket Step 3 Insert the barndoor so that it freely rotates within the other three wheels Step 4 Rotate the bracket back to its original position and retighten Screw A 5 Plus Manual 8 Revision Printed April 10 1997 CONNECTION AND CABLING The Colour changers can be operated from either and analog or DMX digital signal The interconnecting
12. chnical specifications are subject to change without notification
13. e address selectors In modes 0 2 the internal tangential fan is controlled from the HI LO switch on the front panel of the pcb housing Mode 0 Standard Operation Frame by Frame Mode Frame by Frame Control can be selected in this mode Set the Frame rotary switch to the number of frames excluding Frame O See Page 7 for further instructions 10 Revision Printed April 10 1997 MODES I amp 2 STANDARD MODE PRESET GEL SPEEDS 15 Plus Manual Modes amp 2 Standard Control with Preset Gel Speeds In many cases standard Rainbow features may be required but high speed end to end changes are not necessary In Modes amp 2 the PlusCard can be set to limit the maximum gel speed for longer gel life even lower noise levels and smoother crossfades The speeds of the fans are still controlled by the HI LO switch on the rear of the Rainbow Mode Medium Speed Mode 2 Slow Speed The crossfades are calculated using 2 bit counters resulting in smoother crossfades especially critical on the longer gel string fitted to the 5 Plus Frame by Frame Mode Frame by Frame Control can be selected in this mode Set the Frame rotary switch to the number of frames excluding Frame O See Page 7 for further instructions Hi Revision Printed April 10 1997 MODES 3 TO5 2CHANNEL CONTROL Modes 3 5 Fan Control with preset Gel Speeds Mode Mode Mode Modes 3 5 allow an operator to control the
14. he RCC to be loaded without removing from the unit or laid on the bench Access is easy by removing the interchangeable front housing The PlusCard has position and speed control for simple loading without the need for a console or control signal The gel string is fitted and calibrated using the PlusCard as follows The 15 Plus RCC should be powered up 2 Remove front cover by pressing side catches in and slide the front housing up 3 Set Mode switch to 5 and the Frames to 2 The rolls will position themselves to the zero position Once the rolls have stopped set the Frames switch to O 4 The I5 Rainbow is trimmable between two and sixteen colours using the Range Trim I5 turn potentiometer on the front of the analog pcb The RCC is factory trimmed to colours 5 Laythe colour across the red roller and tape the leading edge of frame zero to the Blue roller Line up the edge of the filter with the marked line on the scroll 6 Holding the filter loosely set the Mode switch to D The frames switch controls the loading speed 0 Stop to 3 Fast Set the Frames setting to and the filter will load onto the blue roll using the red roll as a guide Regulate the speed using the Frame selector At the end one of the following will occur If the unit is under trimmed The RCC will stop at full before the filter has been fully loaded on the blue roll Turn the RANGE TRIM potentiometer clockwise to wind the extra filter onto the blue roll
15. hen Mode 8is selected the internal fan on the 15 Plus is controlled from the Fan switch on the lower front panel 5 Plus Manual 15 Revision Printed April 10 1997 FAN CONTROL FROM DMX ek dl An uud pan 15 Plus Manual With Modes 3 7 it is possible to control the fan from the DMX data input to the scroller With Fast operation Mode 6 all fans are controlled by DMX address 511 With 2 and 3 channel control each fan has its own address Important points when using DMX fan control are ek ek ek ek ek ek Once modes 3 7 are selected the HI LO fan switch on the Rainbow is disabled Control is reverse proportional such 0096 Full and FF OFF This can be reversed by a jumper setting on the pcb if needed This is useful if fan levels are to be patched in with light intensity A thermal sensor will override the fan control and bring the fans on to maintain an acceptable operating temperature on the pcbs If no DMX data is present for the address selected the fans will default to full speed The selected fan speed is indicated on the data light on the base of the Colour changer This can be disabled in software if required Fancontrol can be changed from proportional control to externally controlled HI LO selection via externally reprogrammable software 16 Revision Printed April 10 1997 SPEED CONTROL FROM DMX Theability to control the maximum gel speed is important for
16. inbow Colour Changers GmbH reserves the right to modify the characteristics stated in this instructions manual at any time and without prior notice SETTING THE HOOKWING POSITIONS Adaptor Mk II The 15 Plus Colour Changer for Fresnel Luminaires is supplied with a universal adaptor which allows fitting to a variety of different lanterns The four hookwings can be mounted on the plate in either diagonally or the 0 90 180 270 positions for pole operated or manual lamps The positions are set by loosening the retaining screws holding the hookwings and sliding until the correct number of holes are visible in the slot Where the configuration is to be changed from x to the hookwings can be slid off and easily repositioned The table below and over the page gives a full summary of the of luminaires and their Barndoor slide in dimensions N Fitting Positions Posn Ref Dims To Fit Luminaire Hook angle 412 ARRI Studio 5kW X Compact 4kW MSR 2 402 Strand Pollux 5kW X Pollux 2 5 5kW X Vega OkW X Sirio 2 5 4 6 KW HMI X ADB 5kW Studio SH50S SP50 t 2x2500W SH25S SP25S 3 396 Desisti 5kW Studio X Leonardo 4kW HMI 4 382 5 370 Lee Twister 6 355 Sachtler Director 2025H 3750H 1225D 2550D X 7 343 Arri Studio 2kW X Junior 5kW X Compact 2 5kW MSR ADB 2kW Studio SH20S SHF20S SP20 SPF20 5kW Baby CH50S CP50 2x1250W Fresnel SH12S SPI2S 9 322 Strand IO 313 Desisti Studio 2kW X 5 Plus Manual 5 Revisio
17. ing quickly between states the gel speed of the complete rig can be easily limited on a single fader to avoid all the scrollers jumping from state to state In the same way the fan speeds may be controlled for when total silence is required during a section of a show DMX Address 510 0 00 Max Speed FF Slowest Fade DMX Address 511 0 00 Fans Full On FF Fans Off The gel speed control follows an exponential curve allowing fine tuning of cues at faster times but allowing very long stepless cues to be executed For control consoles whose patch is limited to less than 512 dimmers an internal jumper can be set such that the speed and fan addresses are 191 192 Fast Frame by Frame Control Fast control setting can be used in frame by frame mode by setting the Frame selector to the number of frames in the gel string Fan and Gel Speed control are as above 13 Revision Printed April 10 1997 MODE 7 THREE CHANNEL CONTROL 15 Plus Manual Mode 7 Control of Position Fan Gel Speed Where total flexibility is required the Rainbow can be controlled using three control channels Lighting cues can be plotted with colour information limits on the maximum speed of gel movement and fan speeds Each Rainbow uses three independent DMX addresses for control of these features For example Ay G Ay c h c V qu BA one eee ii i i rainbow Address Gel Position Address Gel Speed Fan
18. m speed to the new DMX input value 5 Plus Manual 22 Revision Printed April 10 1997 APPENDIX A DIAGNOSTIC LEDS The Plus Card is designed to use both the existing diagnostic leds on the base of the Rainbow and two rear mounted leds to give feedback as to the operational status of the PlusCard and the input signal In normal operation the diagnostic LEDs indicate the following DATA Led Green Base of Colour Changer Fan Speed Off No Valid Digital Data is being received Proportional Fan Speed Indication 2 Hz Slow Flash Slow Fan Speed to Quick Flash Fast Fan Speed On Fans Off Modes 3 7 Fans not under control of PlusCard Modes 0 2 Out of Valid Address Range Slow Flash Set address is outside range of 1 512 for DMX 8 s on 8s off Software Parameter Download When downloading via an RPC link the DATA led will flash to indicate correct data transfer to the PlusCard DIAG Led Red Rear panel Processor Status Normal Operation Hz Flash Healthy Processor Status Other Check processor performance diagnostics Program Version Check Modes B 7 and B 8 No of flashes Software version EXT Led Yellow Rear Panel Proportional to the voltage to the external fan will be extinguished if there is a short circuit on the external fan port 5 Plus Manual 23 Revision Printed April 10 1997 APPENDIX B DOWSER DIMMER SHUTTER CONTROL The PlusCard is designed with an external C communications por
19. n I Printed April 10 1997 PREPARING THE GEL STRINGS The manufacture of a good gel string is important for the smooth and quiet running ofthe colour changer Rainbow Colour C hangers offer a rapid scroll making service please contact your local dealer for this facility If you are manufacturing your own gel strings they should be cut as follows 410mm 16 15 560mm 22 05 660mm 26 0 e Good quality colour scrolls ensure the smooth and quiet running of the colour changers e Frames should be connected together with Special High Temperature Tape connected to the front side ofthe filter Tape can be ordered from Rainbow Colour C hangers Ensure that sides are parallel and the bottom edge is straight The frames should be taped edge to edge avoiding overlapping the colours e We suggest that you avoid mixing polyester and polycarbonate gels because they expand at different rates and will cause uneven travel THERMAL MANAGEMENT The 5 Rainbow is fitted with a tangential fan for efficient cooling across the full width of the filter frame The fan can be controlled from either the HIGH LOW switch or the proportional fan control on the PlusCards The filter life is dependent on many factors such as the lamp colour type and whether heatshield is fitted 5 Plus Manual 6 Revision Printed April 10 1997 FITTING THE GEL STRING The Gel String is fitted from the front of the unit This allows t
20. reset medium speed The levels are set in hexadecimal using the Address and Frames switches as follows Address 0 255 Most significant 8 bits of level Coarse Frame 0 F x Least significant 4 bits of level Fine Selection of Position ADE 2 92 Highest 8 bits AD x 173 Address Setting Lowest 4 bits E Frames Mode D 10096 Output for Loading Trimming Fades the output level to 100 irrespective of control input This can be used when loading and trimming the colour changers on the bench to avoid the need for a DMX controller The speed of the fade is controlled by the Frames selector as follows Frame Selector Speed 0 and 4 E Stop Slow 2 and F Medium 3 Fast Example Slow fade to 00 4 5 A 5 5 ES c ES c Es c e oN N i e SB SB amp 0 b b Q b Address 15 Plus Manual 20 Revision Printed April 10 1997 RAINBOW SETUP TEST MODES CONT Mode E Percentage Level Set using Address Selector Selects an output level between 0l and 99 irrespective of the control input This can be used to trim the scroll or to compare with a console output The percentage level is selected on the Address Selectors and the speed is controlled from the Frame selector as follows Address Level Frame Selector Speed 01 01 96 0 and 4 E Stop nn nn 96 Slow 99 99 96 2 and F Medium 3 Fast Example Slow movement to 50 46 A 5 5 x T WD D l lt UN uw OON ES NI c
21. t to supply power and control signals to an external dowser This is connected via the 6 way connector on the rear panel of the colour changer When the dowser is connected it is sensed via the port and an extra control channel is allocated for dowser drive This means that all modes have one extra operating parameter as follows ER DOWSER GEL POSITION FAN SPEED DOWSER GEL POSITION FAN SPEED 6 FAST DOWSER GEL POSITION DOWSER GEL POSITION GEL SPEED FAN SPEED The dowser can be set to default as the last control channel via a hardware jumper on the pcb 23 m For furtherinformation on the control of dowsers and external devices with the Pluscard please contact Rainbow C olour C hangers 5 Plus Manual 24 Revision Printed April 10 1997 rainbow COLOUR CHANIG ERIS Worldwide Distribution Premier Lighting Products International GmbH An der Talle 24 28 D 33102 Paderborn Germany Tel 49 0 52 51 14 092 28 Fax 49 0 52 51 14 092 90 www plp international com salesOplp international com 2007 Rainbow Colour Changers GmbH Rainbow is a registered trademark of Rainbow Colour Changers GmbH German Distribution Lightpower GmbH An der Talle 24 28 D 33102 Paderborn Germany Tel 49 0 52 51 14 32 0 Fax 49 0 52 51 14 32 80 www lightpower de info lightpower de This manual is valid from the 1 of July 2007 All previous manuals are herewith not valid any longer All te

Download Pdf Manuals