Operating Instructions - ACS-CONTROL

image

Contents

1. ModBus operating modes B ADDE Default ASCII There are two different types of operating modes ASCII and RTU Modbus transfers no binary cycle but the ASCII Code Thus it is directly readable however the data throughput is smaller in comparison to the RTU Modbus RTU RTU Remote Terminal Unit transfers the data in binary coded This leads to a good data troughput even though the data cannot be evaluated directly as they first need to be transfered into a readable format Timeout TIOUT Default 090 noo TOD S E The monitoring of the data transfer is parameterised in seconds up to max 100 seconds there is no monitoring with an input of 000 The timeout is adjusted from the smallest to the largest digit with the navigation keys A Y and confirmed digit per digit with P After the last digit the device changes back into menu level Back to menu group level RET With P the selection is confirmed and the device changes into menu group level 5ER 20 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 5 4 5 Analog output parameters for analog output 1 Menu group level
2. Setting the initial value of the analog output 9U2 0F Default 00000 ge 297878 The initial value is adjusted from the smallest to the highest digit with A Y and confirmed digit per digit with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level Overflow behaviour 0U2 FL Default EDGE P EWE EoEnd 4 Eor a pP To recognise and evaluate faulty signals e g by a controller the overflow behaviour of the analog output can be defined As overflow can be seen either EDGE that means the analog output runs on the set limits e g 4 and 20 mA or TO DFF input value smaller than initial value analog output switches on e g 4 mA TO END higher than final value analog output switches on e g 20 mA If TO MIN or TO MAX is set the analog output switches on the smallest or highest possible binary value This means that values of e g 0 mA 0 VDC or values higher than 20 mA or 10 VDC can be reached With P the selection is confirmed and the device changes into menu level Back to menu group level RET With P the selection is confirmed and the device changes into menu group level 0U2 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307
3. Pl Mensen Selection reference of analog output DUTPT Default ACTUA ACELA nl TAH Hol id AUG E diFF P The analog output signal can refer to different functions in detail these are the current measurand the min value the max value the totaliser function sum function the constant value or the difference between current measurand and constant value If HOLD was selected the signal of the analog output will be kept It can be continued processing after a deactivation of HOLD With P the selection is confirmed and the device changes into menu level Selection analog output QUT RA Default 4 20 nm m Al In mj lA 4 Li Ul g HH h ci a P Three output signals are available 0 10 VDC 0 20 mA and 4 20 mA Select the desired signal with this function Setting the final value of the analog output OUT EN Default 10000 Ae geglghaza The final value is adjusted from the smallest to the highest digit with A VY and confirmed digit per digit with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level Setting the initial value of the analog output QUT OF Default 09000 7 7 z a s
4. jP p ageger The maximum constant value is selected and adjusted from the smallest to the highest digit with A Y and confirmed digit per digit with P A minus sign can only be adjusted on the highest digit After the last digit the display changes back into menu level Display DISPL Default ACTUR AcELA S mM AUA AHJA A a HolL g AUG con E d IF F With this function the current measuring value the min value max value the totaliser the process controlled hold value the sliding average value the constant value or the difference between constant value and current value can be allocated to the display With P the selection is confirmed and the device changes into menu level Brightness control LIGHT Default 75 1a A SAR The brightness of the display can be adjusted in 16 levels from 00 very dark to 15 very bright via this parameter or alternatively via the navigation keys from the outside During the start of the device the level that is deposited under this parameter will always be used even though the brightness has been changed via the navigation keys in the meantime 1 6 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de Menu
5. All parameters can be unlocked with this code after LOC has been activated under menu item RUN By pressing P for 3 seconds in operation mode the display shows CODE and enables the user to reach all parameters by entering the A CODE Under RUN the parameterisation can be activated permanently by selecting ULOC or PROF thus at an anew pushing of P in operation mode the code needs not to be entered again 5 3 Programming interlock RUN Activation deactivation of the programming lock or completion of the standard parameterisation with change into menu group level complete function range RUN Default ULOC oc amp P With the navigation keys A V choose between the deactivated key lock ULOC works setting and the activated key lock LOC or the change into the menu group level PROF Confirm the selection with P After this the display confirms the settings with and switches automatically to operating mode If LOC was selected the keyboard is locked To get back into the menu level press P for 3 seconds in operating mode Now enter the CODE works setting 1234 that appears using A Y plus P to unlock the keyboard FAIL appears if the input is wrong To parameterise further functions PROF needs to be set The device confirms this setting and changes automatically in operation mode By pressing P for approx 3 seconds in operation mode the first menu group INP is shown in the display
6. db db db db db db moa bb db lt gt For the operation mode special functions can be deposited on the O key This function is activated by pressing the key With TARA the device is set temporarily on zero and saved permanently as offset The device acknowledges the correct taring by showing 80000 in display SET TA switches into the offset value and can be adjusted via the navigation keys Via TOTAL the current value of the totaliser can be displayed after this the device switches back on the parameterised display value If TOT RE was deposited the totaliser can be set back by pressing of the navigation keys A Y the device acknowledges this with 00000 in the display EHT RE deletes the min max memory If HOLD has been selected the moment can be hold constant by pressing the O key and is updated by releasing the key Advice HOLD is activated only if HOLD was selected under parameter DISPL ACTUA shows the measuring value after this the device switches back on the parameterised display value The same goes for AVG here the sliding average value will be displayed Via SECAL a sensor calibration is done by pressing the zero key the operating diagram is shown in chapter 8 The constant value CONST can be called up via the key or adjusted digit per digit At AL 1 AL 4 an output can be set and therewith can e g a setpoint adjustment be done If NO is selected the O key is without any
7. zu Switch off switch on optional switching L MI output e g 7 132 For minimum 1 measuring cycle minimum 1s or maximum per actuator For calibration problems or 30 seconds holding time 1 IE Current measuring range value For minimum 1 measuring cycle minimum 1s or maximum per actuator Optional switch off switching output and display for minimum 1 measuring cycle or minimum 1s holding time Back to regular operation mode after Back to regular operation mode 1s or 1 measuring cycle 3 2 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 10 Technical data 96x48x120 mm BxHxD 96x48x139 mm BxHxD incl plug in terminal Panel cut out 92 0 0 8 x 45 0 0 6 mm Wall thickness up to 15 mm screw elements PC Polycarbonate black UL94V 0 EPDM 65 Shore black standard IP65 front IPOO back side Fixing Material Sealing material Protection class Weight approx 300 g Connection plug in terminal wire cross section up to 2 5 mm Display Digit height 14 mm Segment colour red optional green orange or blue Display range 19999 up to 99999 Setpoints one LED per setpoint Overflow Underflow horizontal bars at the top horizontal bars at the top 0 1 to 10 0 seconds Measuring range Measuring error gt 1k Q lt 1 000 kO 1 100 0 5 of mea
8. 49 0 8721 9668 30 ACS CONTROL SYSTEM fXg3 knowhow with system contsys less Your partner for measuring technology and automation Stand 04 2015
9. Ad hd Cy al P One can choose between the above shown physical units It will be displayed on the 5th digit of the display ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 13 Menu level Parameterisation level Number of additional setpoints SPCT Default 00 0 8 08e 30 additional setpoints can be defined to the initial value and final value so linear sensor values are not linearised Only activated setpoint parameters are displayed Display values for setpoints DI5 01 DIS 30 Ian zE I Under this parameter setpoints are defined according to their value At the sensor calibration like at final value offset one is asked at the end if a calibration shall be activated Analog values for setpoints NP 07 INP 30 g P g P g e N E pa mi The setpoints are always preset according to the selected input signal mA V The demanded analog values can be freely adjusted in ascending order Device undercut DI UND Default 9999 a P A P B gegn Cy Li With this function the device undercut can be defined on a definite value Display overflow DI OUE Defa
10. parameters and can be unlocked again with an individual code Optional the following functions are available a supply for the sensor a digital input for triggering of Hold Tara two analog outputs and interfaces for further evaluating in the unit With help of the galvanic isolated setpoints optional free adjustable limit values can be controlled and reported to a superior master display The electrical connection is done via plug in terminals on the back side Selectable functions like e g the recall of the min max value an averaging of the measuring signals a nominal presetting or setpoint presetting a direct threshold value regulation during operation mode and further measuring setpoints for linearisation complete the modern device concept ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 2 Assembly Please read the Safety advices on page 33 before installation and keep this user manual for future reference 48 0 Gap for physical unit After removing the fixing elements insert the device Check the seal to make sure it fits securely Click the fixing elements back into place and tighten the clamping screws by hand Then use a screwdriver to tighten them another half a turn N CAUTION The torque should not exceed 0 1 Nm The dimension symbols can be exchanged before installation via a channel on the side ACS CONTROL S
11. AWNO only at 0 4 20 mA 0 10V DC input function input 6 potentiometer measurement gt 1 kOhm up to lt 1000kOhm function output display 2 relay outputs changeover display 4 relay outputs display with analog output 0 10V 4 20mA switchable display 2 relay with analog output 0 10V 4 20mA switchable display 4 relay with analog output 0 10V 4 20mA switchable others outputs lt monu gt 0 standard configuration S standard protection IP65 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de Contents 1 2 3 4 10 11 12 Brief description Assembly Electrical connection Description of function and operation 4 1 Programming software PM TOOL Setting up the device 5 1 Switching on 5 2 Standard parameterisation flat operation level Value assignment for the triggering of the signal input 5 3 Programming interlock RUN Activation Deactivation of the programming interlock or change into professional or flat operation level 5 4 Extended parametersation professional operation level 5 4 1 Signal input parameters INP Value assignment for the triggering of the signal input incl linearisation 5 4 2 General device parameters FLT Superior device functions like Hold Tara min max permanent setpoint value function nominal value function averaging brightness control as well as the control of
12. D plug Connection RS485 Digital device M3 120 Q Pc DATAA 115 DATA B GND The interface RS485 is connected via a screened data line with twisted wires Twisted Pair On each end of the bus segment a termination of the bus lines needs to be connected This is neccessary to ensure a secure data transfer to the bus For this a resistance 120 Ohm is interposed between the lines Data B and Data A ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 3 1 9 Sensor alignment offset final value The device is equipped with a semi automatic sensor calibration SENSE A switching output operates the trimming resistor which exists in some sensors An adjustment of offset and final value takes place after which the sensor can be used directly Depending on parameterisation the calibration can be realized via the fourth key or via the digital input It is possible to key during the calibration steps So reference signals can be connected manually However the calibration will be interrupted after 30 seconds Press actuator for minimum 3 seconds Vit Activate optional switching output a For calibration U For minimum 1 measuring cycle minimum Dem ar a seconds holding 1s or maximum per actuator time I Current measuring range value eg 0 061 For minimum 1 measuring cycle or with actuator
13. defined by the hysteresis 1 0 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de Menu level Parameterisation level Function for threshold value undercut exceedance FU Default HIGH tau E A limit value undercut is selected with LOUU for LOW lower limit value a limit value exceedance with HIGH for HIGH higher limit value If e g limit value 1 is on a threshold level of 100 and allocated with function HIGH an alarm is activated by reaching of threshold level If the threshold value was allocated to LOW an alarm will be activated by undercutting the threshold value as long as the hysteresis is zero User code 4 digit number combination free available U CODE Default 0000 se glee te If this code was set gt 0000 all parameters are locked for the user if LOC has been selected before under menu item RUN By pressing P for 3 seconds in operation mode the display shows CODE The U CODE needs to be entered to get to the reduced number of parameter sets The code has to be entered befor each parameterisation until the A CODE Master code unlocks all parameters again Master code 4 digit number combination free available A CODE Default 1234 Gg gels sa L L L
14. selection by pressing the P button The display then switches back to the menu level again Rescaling the measuring input values ENDA Default 10000 gPa g e g l L With this function you can rescale the input value of e g 9 5 kQ works setting without applying a measuring signal Rescaling the measuring input values OFFA Default 0 g B g P g e g e With this function you can rescale the input value of e g 1 5 KQ works setting without applying a measuring signal I ga P Setting up the tare offset value TARA Default 0 jepe gpeg se gj The given value is added to the linearized value In this way the characteristic line can be shifted by the selected amount Setting up the balance point ADJ PT Default 08000 rij P H P The balance point for the final value can be chosen in from the measuring range by SENSE The preset 80 000 result from the widespread detuning of the melt pressure sensors The ADJ PT is only used by the sensor alignment SE CAL J e 1 Li Setting up the physical unit UNIT Default NO T A L Cc 4 a a a Ad T wi iy v
15. the device takes over both the display value and the analogue input value Setting the start offset value of the measuring range OFFS Default 0 JAgzgegeags 3E Enter the start offset value from the smallest to the highest digit with A Y and confirm each digit with P After the last digit the display switches back to the menu level If SENS was selected as input option you can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL the device takes over both the display value and the analogue input value L Setting the comma decimal point DOT Default 0 v v The decimal point on the display can be moved with A Y and confirmed with P The display then switches back to the menu level again 1 2 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de Menu level Parameterisation level Setting up the display time SEC Default 1 0 g then Do E o ooo e The display time is set with 4 Y The display moves up in increments of 0 1 up to 1 second and in increments of 1 0 up to 10 0 seconds Confirm the
16. the digital input and keyboard layout 5 4 3 Safety parameters COD Assignment of user and master code to lock or to receive access to defined parameter such as analog output and alarms etc 5 4 4 Serial parameters SER Parameter for interface definition 5 4 5 Analog parameters OUT and OUZ Analog outpur functions 5 4 6 Relay functions REL Parameter for setpoint definition 5 4 7 Alarm parameters AL1 ALY Actuator and dependencies of the alarms 5 4 8 Totaliser Volume metering TOT Parameter for calculation of the sum function Reset to factory settings Reset parameters onto the delivery state Alarms Relays Functional principle of the switching outputs Interfaces Connection RS232 and RS485 Sensor aligment Diagram of functional sequences for sensors with existing adjustable resistor Technical data Safety advices Error elimination N NN OO OO FF W N 10 10 13 17 18 19 22 24 26 27 28 29 30 31 33 34 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 1 Brief description The panel meter instrument DAL 311 is a 5 digit device for potentiometer values of gt 1kQ to lt 1000kQ and a visual threshold value monitoring via the display The configuration happens via 4 keys at the front or via the optional PC software PM TOOL The integrated programming interlock prevents unrequested changes of
17. to the menu level The activator for the reset is parameter driven via the 4 key or via the optional digital input Back to menu group level RET With P the selection is confirmed and the device changes into menu group level TOT Programming interlock RUN Menu group level 2 W v LI P Description see page 9 menu level RUN ra 6 Reset to default values To return the unit to a defined basic state a reset can be carried out to the default values The following procedure should be used e Switch off the power supply e Press button P e Switch on voltage supply and press P button until is shown in the display With reset the default values of the program table are loaded and used for subsequent operation This sets the unit back to the state in which it was supplied Caution All application related data are lost ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 29 7 Alarms Relays This device has 8 virtual alarms that can monitor one limit value in regard of an undercut or exceedance Each alarm can be allocated to an optional relay output S1 S4 furthermore alarms can be controlled by events like e g Hold or min max value Function principle of alarms relays Alarm Relay x Deactivated instantaneous value min max value hold value totaliser value slidi
18. Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 23 5 4 6 Relay functions Menu group level Alarm relay 1 REL I Default AL 1 A L A CAL CALE amp Each setpoint optional can be linked up via 4 alarms by default This can either be inserted at activated alarms ALI Y or deactivated alarms ALNI4 If LOGIC was selected logical links are available in the menu level L amp G 7 and CON I Access to these two menu levels is via LOGIC at all other selected functions these two parameters are overleaped Via ON OFF the setpoints can be activated deactivated in this case the output and the setpoint display are set not set on the front of the device The parameters CAL CAL OF and CAL EN can only be used in accordance with the semi automatic calibration Chapter 9 Sensor alignment At CAL the relay switches during sensor calibration at CAL OF during offset calibration and at CAL EN during the calibration of the final value With P the selection is confirmed and the device changes into menu level Logic relay 1 L06 7 Default OR m z no And And P Here the switching behaviour of the relay is defined via a logic li
19. Oo BB Al fill level water level pressure temperature flow visualization signal converter sensoric 2 u LRKSL LU Technical features e red display of 19999 99999 digits optional green orange blue installation 120 mm without plug in terminal min max memory e 30 adjustable setpoints display flashing at threshold value exceedance threshold value undercut e zero key for triggering of Hold Tara permanent min max value recording e volume metering totaliser e mathematic functions like reciprocal value square root squaring or rounding e setpoint generator e sliding average determination brightness control programming interlock via access code protection class IP65 at the front side plug in screw terminal e optional galvanic isolated digital input optional 1 or 2 analog outputs optional 2 or 4 relay outputs or 8 PhotoMos outputs e optional RS232 or RS485 interface e accessories PC based configuration kit PM TOOL with CD amp USB adapter for devices without keypad and for a simple adjustment of standard devices ACS CONTROL SYSTEM X kr em contsys Your partner for measuring technology and automation Order code power supply 100 240V AC 10 40V DC galvanic seperated 100 240V AC with sensor supply 24V DC 50mA and digital input 10 40V DC galvanic seperated with sensor supply 24V DC 50mA and digital input other voltages 1 sensor supply lt
20. TA switches into the offset value and can be adjusted via the navigation keys Via TOTAL the current value of the totaliser can be displayed after this the device switches back on the parameterised display value If TOT RE was deposited the totaliser can be set back by pressing of the navigation keys A W the device acknowledges this with showing 00008 in the display By allocation on EHT RE the min max memory is deleted At ACTUA the measuring value is shown after this the device switches back on the parameterised display value With LIGHT the brightness of the display is adjusted This setting is not saved and gets lost at a restart fo the device Via selection 21 7 L1 1 2 LI 1 3 L11 4 in case of 8 switching points L1 5 L1 1 8 threshold values can be addressed via the navigation keys they can be changed digit per digit or taken over by pushing the P key The adjustment is taken over directly an excisting limit value monitoring and the current measurement will not be influenced by this If NO is selected the navigation keys are without any function in the operation mode ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 1 7 Menu level Parameterisation level Special function O key TAST 4 Default NO EAr E
21. YSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 3 Electrical connection Type DAL 311x6x0S with a supply of 10 40 VDC galv isolated 18 30 VDC Type DAL 311x6x0S with a supply of 100 240 VAC DC 10 olololelolo olo 10 40 VDC or 100 240 VAQ Options 2 8 2 28 e o oO gt oO gt N o N oO Eo Digital Analog output 1 Analog output 2 input u e eh Relay 1 and 2 8 PhotoMos outputs alternative to analog output 2 e Q Q a oO Fi sS fi z a a Interface RS232 Interface RS485 Modbus protocol Modbus protocol DAL 311x6x0S with digital input and external voltage source Digital input 10 30 VDC ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 4 Description of function and operation Operation The operation is divided into three different levels Menu level delivery status This level was designed for the standard settings of the device Only menu items which are sufficent to set the device into operation are displayed To get into the professional level run through the menu level and parameterise PROF under menu item RUN Menu group level complete function volume Suited for complex applications as e g linkage of alarms setpoint treatment totaliser function etc In this level function groups which allow an extended paramet
22. a E This function is for instable display values where the display value is changed in steps of 1 5 10 or 50 This does not affect the resolution of the optional outputs With P the selection is confirmed and the device changes into menu level Arithmetics ARITH Default NO Eorp A Fra A Ssuar P Reciprocal v Root extraction Square With this function the calculated value not the measuring value is shown in the display With NO no calculation will be deposited With P the selection is confirmed and the device changes into menu level Sliding average determination AVG Default 72 HE ng P Under this menu item the number of measurements that need to be averaged are preset The averaging time results from the product of measuring time SEC and the averaged measurements AVG With selection of AVG in menu level DISPL the result is shown in the display and evaluated when entered in the alarm ALI AL4 or the analog output QUTPT Zero point slowdown ZERO Default 00 oH te At the zero point slowdown a value range around the zero point can be preset so the display shows a zero If e g 10 is set the display would show a zero in the value rang
23. again Selection of analog output QUT RA Default 4 20 Alan Ans A m LI um uu CIM wy Ol a P Three output signals are available 0 10 VDC 0 20 mA and 4 20 mA with this function the demanded signal is selected Setting up the final value of the analog output OUT EN Default 10000 o P pepe geger The final value is adjusted from the smallest digit to the highest digit with A V and digit by digit confirmed with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level Setting up the initial value of the analog output OUT OF Default 09000 3 P n Pla Plo E g egege aga The final value is adjusted from the smallest digit to the highest digit with A V and digit by digit confirmed with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level Threshold values limits L 7 Default 2008 AAGeGeG8o se This value defines the threshold that activates deactivates an alarm Hysteresis for limit values 4 1 Default 00000 AEG 2GA2geo se The delayed reaction of the alarm is the difference to the threshold value which is
24. and thus confirms the change into the extended parameterisation It stays activated as long as ULOC or LOC is entered in menu group RUN ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 1 1 5 4 Extended parameterisation Professional operation level 5 4 1 Signal input parameters Menu group level Pl Menue Selection of the input signal TYPE Default SENS Potentiometer values from gt 1 to lt 1000 kQ are available as works calibration without application of the sensor signal and as sensor calibration with applied measuring signal Confirm the selection with P and the display switches back to menu level Setting the end value of the measuring range END Default 10000 A JegrgegegS zE l L Set the end value from the smallest to the highest digit with A Y and confirm each digit with P A minus sign can only be parameterized on the highest value digit After the last digit the display switches back to the menu level If SENS was selected as input option you can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL
25. auterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 11 Safety advices Please read the following safety advices and the assembly chapter 2 before installation and keep it for future reference Proper use The DAL 311 device is designed for the evaluation and display of sensor signals DER Attention Careless use or improper operation can result in personal injury and or cause damage to the equipment Control of the device The panel meters are checked before dispatch and sent out in perfect condition Should there be any visible damage we recommend close examination of the packaging Please inform the supplier immediately of any damage Installation The DAL 311 device must be installed by a suitably qualified specialist e g with a qualification in industrial electronics Notes on installation e There must be no magnetic or electric fields in the vicinity of the device e g due to transformers mobile phones or electrostatic discharge The fuse rating of the supply voltage should not exceed a value of 6A N B fuse Do not install inductive consumers relays solenoid valves etc near the device and suppress any interference with the aid of RC spark extinguishing combinations or free wheeling diodes e Keep input output and supply lines separate from one another and do not lay them parallel with each other Position go and return lines next to one another Where po
26. ctivated by undercutting the threshold value as long as the hysteresis is zero Switching on delay TON I Default 000 pepeg se For limit value 1 one can preset a delayed switching on of 0 100 seconds Switching off delay TOF I Default 000 geroep se For limit value 1 one can preset a delayed switching off of 0 100 seconds Back to menu group level RET With P the selection is confirmed and the device changes into menu group level ALI The same applies for Al2 to AL ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 27 5 4 8 Totaliser Volume metering P State of totaliser TOTAL Default OFF OFF SEERA A CEENP S F The totaliser realizes measurements on a time base of e g I h there the scaled input signal is integrated by a time and steadily select STEAD or temporarily select TEMP safed Select the constant storage for consumption measurements and the quick storage for frequently filling processes During the constant storage STEAD the current sum value is saved at each totaliser reset Furthermore it is saved every 30 minutes in the not quick storage of the device If OFF is selected the function is deac
27. e from 10 to 10 below continue with 11 and beyond with 11 The maximum adjustable range of value is 99 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 1 5 Menu level Parameterisation level Solid contstant value CONST Default 0 al ALP aPgagsZe Li The constant value can be evaluated like the current measurand via the alarms or the analog output The decimal place cannot be changed for this value and is taken over from the current measurand So with this value a setpoint generator can be realised via the analog output Furthermore it can be used as calculated difference At this the constant value needs to be subtracted from the current measurand and the difference is evaluated in the alerting or via the analog output Thus regulation can be displayed quite easy with this parameterisation Minimum constant value CON Default 19999 1 Ci Ci Cc I a m P a P a l A P PJ Ll The minimum constant value is selected and adjusted from the smallest to the highest digit with 4 Y and confirmed digit per digit with P A minus sign can only be adjusted on the highest digit After the last digit the display changes back into menu level Maximum constant value CON NA Default 99999
28. earararat The initial value is adjusted from the smallest to the highest digit with A Y and confirmed digit per digit with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 2 1 Menu level Parameterisation level P Overflow behaviour 0 FLOU Default EDGE JEE Eo a itt H we To recognise and evaluate faulty signals e g by a controller the overflow behaviour of the analog output can be defined As overflow can be seen either EDGE that means the analog output runs on the set limits e g 4 and 20 mA or TO OFF input value smaller than initial value analog output switches on e g 4 mA TO END higher than final value analog output switches on e g 20 mA If TO MIN or TO MAX is set the analog output switches on the smallest or highest possible binary value This means that values of e g 0 mA 0 VDC or values higher than 20 mA or 10 VDC can be reached With P the selection is confirmed and the device changes into menu level Back to menu group level RET With P the selection is confirmed and the device changes into menu group
29. ed up via 4 alarms by default This can either be inserted at activated alarms AL6 8 or deactivated alarms ALN6 8 If LOGIC was selected logical links are available in the menu level L9G 7 and CON I Access to these two menu levels is via LOGIC at all other selected functions these two parameters are overleaped Via ON OFF the setpoints can be activated deactivated in this case the output and the setpoint display are set not set on the front of the device The parameters CAL CAL OF and CAL EN can only be used in accordance with the semi automatic calibration Chapter 9 Sensor alignment At CAL the relay switches during sensor calibration at CAL OF during offset calibration and at CAL EN during the calibration of the final value With P the selection is confirmed and the device changes into menu level Logic relay 5 L0G 5 Default OR ar nal Ang 5 nAnd Ja Here the switching behaviour of the relay is defined via a logic link the following schema describes these functions with inclusion of AL Tand AL 2 A1v A2 As soon as a selected alarm is activated the relay operates Equates to operating current principle mO ATVA2 A1AA2 The relay operates only if no selected alarm is active Equates to quiescent current principle And A1Aa2 The relay operates only if all selected alarms are active niAinld ATAA2 ATVA2 As soon a
30. erisation of the standard settings are availabe To leave the menu group level run through this level and parameterise ULOC under menu item RUN Parameterisation level Parameters deposited in the menu item can here be parameterised Functions that can be changed or adjusted are always signalised by a flashing of the display Settings that are made in the parameterisation level are confirmed with P and thus saved Pressing the O key zero key leads to a break off of the value input and to a change into the menu level All adjustments are saved automatically by the device and changes into operating mode if no further key operation is done within the next 10 seconds Change to parameterisation level and deposited values Menu level Keys for up and down navigation in the menu level Change into operation mode To confirm the changes made at the parameterisation level Parameterisation level Adjustment of the value the setting Change into menu level or break off in value input Change to menu level Menu group level Keys for up and down navigation in the menu group level Change into operation mode or back into menu level ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de Function chart 4 1 Parameterisation software PM TOOL Standard parameterisation Extended parameterisation Flat operation level p
31. et value of the measuring range OFFS Default 0 Brarala Enter the start offset value from the smallest to the highest digit with A V and confirm each digit with P After the last digit the display switches back to the menu level If SENS was selected as input option you can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL the device takes over both the display value and the analogue input value Setting the decimal point DOT Default 0 De 1100 Hl v Wo A A v The decimal point on the display can be moved with A Y and confirmed with P The display then switches back to the menu level again ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 9 Menu level Parameterisation level Setting up the display time SEC Default 1 0 Do 00g e Oo D SP The display time is set with A Y The display moves up in increments of 0 1 up to 1 second and in increments of 1 0 up to 10 0 seconds Confirm the selection by pressing the P button The display then switches back to the menu level
32. eters QUT LE Default ALL al E FS Analog output parameters can be locked or released for the user EN OF the initial or final value can be changed in operation mode OUT EQ the output signal can be changed from e g 0 20 mA to 4 20 mA or 0 10 VDC ALL analog output parameters are released NO all analog output parameters are locked Release lock alarm parameters AL LEU Default ALL al LIE 4 ALE This parameter describes the user release user lock of the alarm LIMIT here only the range of value of the threshold values 1 4 can be changed ALRN L here the range of value and the alarm trigger can be changed ALL all alarm parameters are released NO all alarm parameters are locked ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 1 9 Menu level Parameterisation level Device address ADDR Default 001 am Tem The device address is adjusted from the smallest to the largest digit with the navigation keys 4 Y and confirmed digit per digit with P A device address up to max 250 is available Interface data Baudrate 9600 bit s 8 databyte 1 stopbit no parity 8n1
33. function in the operation mode Special function digital input DIG IN Default NO Erf L c mo AP For the operation mode the above shown parameters can be laid on the optional digital input too Functions description see TAST 4 gt db lt gt gt db lt gt gt db db K Back to menu group level RET With P the selection is confirmed and the device changes into menu group level FLT 18 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 5 4 3 Safety parameters Menu group level n P Menu level Adjustment of user code U CODE Default 0900 gePgegegeg ge Via this code reduced sets of parameters QUT LE and AL LEV can be unlocked during locked programming Further parameters are not available via this code The U CODE can only be changed via the correct input of the A CODE Master code 1 Master code A CODE Default 1234 70 gH78 gee By entering A CODE the device will be released and all parameters unlocked Release lock analog output param
34. level QUT Selection reference of analog output QU2PT Default ACTUA Ack A A al TAH a la ZIC al Hod A E dir P The analog output signal can refer to different functions in detail these are the current measurand the min value the max value the totaliser function sum function the constant value or the difference between current measurand and constant value If HOLD is selected the signal of the analog output will be kept It can be continued processing after a deactivation of HOLD With P the selection is confirmed and the device changes into menu level 22 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de Menu level Parameterisation level Selection analog output OU2Z RA Default 4 20 0 04 0 0 Seo 4 e 3 output signals are available 0 10 VDC 0 20 mA and 4 20 mA Select the desired signal with this function Setting the final value of the analog output QU2 EN Default 10000 AL gF2gXglgsea The final value is adjusted from the smallest to the highest digit with A VY and confirmed digit per digit with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level
35. level Parameterisation level Display flashing FLASH Default NO nN v AIL AL amp cess AOA 5 P A display flashing can be added as additional alarm function either to single or to a combination of off limit condition With NO no flashing is allocated Assignment deposit of key functions TAST Default NO o gt lt gt lt gt P uf gt lt gt lt b gt lt gt gt gt lt gt db For the operation mode special functions can be deposited on the navigation keys A Y in particular this function is made for devices in housing size 48x24mm which do not have a 4th key O key If the min max memory was activated by EHTR all measured min max values are saved during operation and can be recalled via the navigation keys The values get lost by restart of the device If the threshold value correction LI 12 or L134 was choosen the values of the threshold can be changed during operation without disturbing the operating procedure With TARA the device is set temporarily on a parametrised value The device acknowledges the correct taring with 00000 in the display SET
36. ng average value constant value difference between instantaneous value and constant value or an activation via the digital input or the O key Switching threshold Threshold limit value of the change over Broadness of the window between the switching thresholds Working principle Operating current quiescent current Alin Operating current By operating current the alarm S1 S4 is off below the threshold and on on reaching the Threshold threshold On LOA a ee eee ee r r I o W 2 Ags 15 2 5 lt off Display Hysterisis Quiescent current By quiescent current the alarm S1 S4 is on below the threshold and switched off on Threshold reaching the threshold Alarms yo ua le 4 Off Display Hysterisis SF input Switching on delay l The switching on delay is activated via an 10 alarm and e g switched 10 seconds after Switching threshold reaching the switching threshold a short term 0 exceedance of the switching value does not 5 Time s cause an alarm respectively does not cause a switching operation of the relay The switching off delay operates in the same way keeps the alarm the relay switched longer for the parameterised time Alarm switching on delay 10 s Time s 30 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 8 Interfaces Connection RS232 Digital device M3 PC 9 pole Sub
37. nk the following schema describes these functions with inclusion of AL and AL 2 This parameter can only be selected if LOGIC was selected under REL 1 ar ATVA2 As soon as a selected alarm is activated the relay operates Equates to operating current principle or A1vA2 A1A A2 The relay operates only if no selected alarm is active Equates to quiescent current principle An g A1 Aa2 The relay operates only if all selected alarms are active m Alin a A1AA2 A1v A2 As soon as a selected alarm is not activated the relay operates With P the selection is confirmed and the device changes into menu level 24 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de Menu level Parameterisation level Alarms for relay 1 CO 1 Default A l Al AR mega P The allocation of the alarms to relay 1 happens via this parameter one alarm or a group of alarms can be chosen With P the selection is confirmed and the device changes into menu level Alarm relay 5 REL 5 The same applies for relays 6 8 Default AL 5 A JE N v CALOP 4 CALER P Each setpoint optional can be link
38. rofessional operation level Operation mode _ Operation mode OODON O 0000 88888 8585888 B AGO x x x U run prof P N Menu level B nn fun ULC 0 Input break O X Input break P or gt 10s or o gt 10s e N P O A a Menu level al A W C A on P Parameter level la v Underline P Takeover OJ Stop A Value selection V Value selection Part of the PM TOOL are the software on CD and an USB cable with device adapter The connection is done via a 4 pole micromatch plug on the back side of the device to the PC side the connection ist done via an USB plug System requirements PC incl USB interface Software Windows XP Windows VISTA With this tool the device configuration can be generated omitted and saved on the PC The parameters can be changed via the easy to handle program surface whereat the operating mode and the possible selection options can be preset by the program ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 5 Setting up the device 5 1 Switching on Once the installation is complete start the device by applying the voltage supply Before check once again that all electrical connections are correct Starting sequence For 1 second during the switching on process the segment test 8 8 8 8 8 is displayed followed by an indica
39. s a selected alarm is not activated the relay operates With P the selection is confirmed and the device changes into menu level ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 25 Menu level Parameterisation level Alarms for relay 5 ON 5 Default 4 5 N AS v 5 a vn 15 B78 F The allocation of the alarms to relay 5 happens via this parameter one alarm or a group of alarms can be chosen With P the selection is confirmed and the device changes into menu level Back to menu group level RET With P the selection is confirmed and the device changes into menu group level REL Dependency alarm 1 ALRN 1 Default ACTUA Z E L a v P E N v n v The dependency of ALARf I can be related to special functions in detail these are the current measuring value the min value the max value the totaliser value sum value the constant value or the difference between the current measurand and the constant value If HOLD was selected the alarm is hold and processed just after deactivation of HOLD EHTER causes
40. ssible use twisted pair So you receive best measuring results e Screen off and twist sensor lines Do not lay current carrying lines in the vicinity Connect the screening on one side on a suitable potential equaliser normally signal ground e The device is not suitable for installation in areas where there is a risk of explosion e Any electrical connection deviating from the connection diagram can endanger human life and or can destroy the equipment e The terminal area of the devices is part of the service Here electrostatic discharge needs to be avoided Attention High voltages can cause dangerous body currents e Galvanic isolated potentials within one complex need to be placed on an appropriate point normally earth or machines ground So a lower disturbance sensibility against impacted energy can be reached and dangerous potentials that can occur on long lines or due to faulty wiring can be avoided ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 3 5 12 Error elimination 1 The unit permanently indicates e The input has a very high measurement check overflow the measuring circuit e With a selected input with a low voltage signal it is only connected on one side or the input is open e Not all of the activated setpoints are parameterised Check if the relevant parameters are adjusted correctly The unit permanently sho
41. suring range lt 2 4 V OFF 10 V ON max 30 VDC R 5kO Display time i Digital input Accuracy Temperature drift 100 ppm K Measuring time 0 1 10 0 seconds Measuring principle U F conversion Resolution approx 18 bit at 1s measuring time ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 3 3 Analog output 0 4 20 mA burden s500 Q 0 10 VDC burden 210 KQ 16 bit Switching outputs Relay with change over contacts 250 VAC 5 AAC 30 VDC 5 ADC Switching cycles 30 x 10 at 5 AAC 5 ADC ohm resistive burden 10 x 108 mechanically Diversification according to DIN EN50178 Characteristics according to DIN EN60255 PhotoMos outputs Closer contacts 30 VDC AC 0 4A Protocol Modbus with ASCII or RTU protocol RS232 9 600 Baud no parity 8 Databit 1 Stopbit cable length max 3 m RS485 9 600 Baud no parity 8 Databit 1 Stopbit cable length max 1000 m Power supply 100 240 VAC 50 60 Hz DC 10 max 15 VA 10 40 VDC 18 30 VAC 50 60 Hz max 15 VA Memory EEPROM Data life 2 100 years 25 C Ambient conditions Working temperature 0 50 C Storing temperature 20 80 C Wheatering resistance relative humidity 0 80 on years average without dew EMV EN 61326 EN 55011 Conformity according to directive 2004 108 EG Safety standard According to low voltage directive 2006 95 EG EN 61010 EN 60664 1 34 ACS CONTROL SYSTEM GmbH L
42. the dependency either by pressing the O key on the front of the housing or by an external signal via the digital input With P the selection is confirmed and the device changes into menu level Example By using the maximum value ALARf T MAX VA in combination with a threshold monitoring FU 7 HIGH an alarm confirmation can be realised Use the navigation keys the 4th key or the digital input for confirmation 26 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de Menu level Parameterisation level Threshold values limit values L Default 2000 AGG 2g8o ga The limit value defines the threshold that activates deactivates an alarm Hysteresis for threshold values H 1 Default 00000 page eee0 se The delayed reaction of the alarm is the difference to the threshold value which is defined by the hysteresis Function for threshold value undercut exceedance FU Default HIGH 4 a A limit value undercut is selected with LOUU for LOW lower limit value a limit value exceedance with HIGH for HIGH higher limit value If e g limit value 1 is on a threshold level of 100 and allocated with function HIGH an alarm is activated by reaching of the threshold level If the threshold value was allocated to LOW an alarm will be a
43. tion of the software type and after that also for 1 second the software version After the starting sequence the device switches to operation display mode 5 2 Standard parameterisation Flat operation level To parameterise the display press the P key in operating mode for 1 second The display then changes to the menu level with the first menu item TYPE Menu level Parameterisation level Selection of the input signal TYPE Default SENS SCALE SESE P Potentiometer values from gt 1 to lt 1000 kQ are available as works calibration without application of the sensor signal and as sensor calibration with applied measuring signal Confirm the selection with P and the display switches back to menu level Setting the end value of the measuring range END Default 10000 PALALA ee L Set the end value from the smallest to the highest digit with 4 Y and confirm each digit with P A minus sign can only be parameterized on the highest value digit After the last digit the display switches back to the menu level If SENS was selected as input option you can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL the device takes over both the display value and the analogue input value Setting the start offs
44. tivated With P the selection is confirmed and the device changes into menu level Time base T BASE Default SEC SECS d o dS E Under this parameter the time base of the measurement can be preset in seconds minutes or hours Totaliser factor FACTO Default IEO EOS E At this the factor 1E0 1E6 respectively the divisor for the internal calculation of the measuring value is assigned Setting up the decimal point for the totaliser TOT DT Default 0 agaga e The decimal point of the device can be adjusted with the navigation keys A Y With P the selection is confirmed and the device changes into menu level 28 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de Menu level Parameterisation level Totaliser reset TOT RE Default 09000 AXgegla tea The reset value is adjusted from the smallest to the highest digit with the navigation keys A Y and digit per digit confirmed with P After the last digit the display switches back
45. ult 99999 0 e p ep eae gge j With this function the display overflow can be defined on a definite value Input variable of process value SIG IN Default A MERS ANERS MELS FP With this parameter the device can be controlled via the analog input signals A MEAS 10 VAC 50 VAC respectively 1 5 AAC or via the digital signals of the interface f BUS RS232 RS485 Modbus protocol With P the selection is confirmed and the device changes into menu level Back to menu group level RET With P the selection is confirmed and the device changes into menu group level INP 14 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden Iwww acs controlsystem delinfo acs controlsystem de 5 4 2 General device parameters Menu group level a P Menu level Display time DISEC Default 01 0 go CO0 e EA on de The display time is set up with A Y Thereby you switch up to 1 second in steps of 0 1 and up to 10 0 seconds in steps of 1 0 With P the selection is confirmed and the device changes into menu level Rounding of display values ROUND Default 00001 1 00005 4 coomo goas
46. ws e The input has a very low measurement check underflow the measuring circuit e With a selected input with a low voltage signal it is only connected on one side or the input is open e Not all of the activated setpoints are parameterised Check if the relevant parameters are adjusted correctly The word HELP lights up in the e The unit has found an error in the configuration 7 segment display memory Perform a reset on the default values and reconfigure the unit according to your application 4 Program numbers for parameterising e Programming lock is activated of the input are not accessible Enter correct code 5 ERRI lights up in the 7 segment display Please contact the manufacturer if errors of this kind occur The device does not react as If you are not sure that the device has been expected parameterised before then follow the steps as written in chapter 6 and set it back to its delivery status 36 ACS CONTROL SYSTEM GmbH Lauterbachstr 571D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de ACS CONTROL SYSTEM GmbH Lauterbachstr 57 1D 84307 Eggenfelden www acs controlsystem delinfo acs controlsystem de 3 7 SHOKCHOE ECK Hei BF fill level water level pressure temperature flow visualization signal converter sensoric Wir erwarten Ihren Anruf ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden Tel 49 0 8721 9668 0 Fax

Download Pdf Manuals

image

Related Search

Related Contents

American Standard T064700 User's Manual  【ぽん】 <図解入り> アメブロパーフェクトマニュアル ~アメブロ取扱説明書  Peerless YBA100 flat panel wall mount  SELECTRA PROXS - JAMPAR Multiplest Internacional  Association Models Supplement to the Certified Wireless  Communication Interface Manual  平成16年度採択課題 革新的ガンマ線計測システムの開発  VSC 2000 User`s Manual  Manual Alisadora pág.cdr  LEER-41001-LD9+LEEM-40201L-01  