Home
Source Four HID PARTM CE User Guide
Contents
1. color frame retaining clip 4 Hold the lens by the edge and position it so the convex side faces the back of the fixture Figure 4 5 From the top of the fixture slide the lens behind the lens catchers and position its base behind the tabs on the bottom of the lens rotation ring 6 Gently push the top of the lens inward until it snaps behind the spring clip Retaining clip f Spring clip ii 1 Tab Figure 4 Colour frame retaining clip usage The colour frame holder is equipped with a spring loaded retaining clip that prevents colour frames and accesso ries from falling out Make sure the Source Four HID PAR CE has the colour frame retaining clip in the locked position when hanging 0 Note Make sure to use colourframes or accessories with a 17 cm inside diameter 1 Release the retaining clip by pushing it sideways The retaining clip opens 2 Insert the colour frame 3 Press the retaining clip down until it locks Retaining clip in the locked position fe Figure 5 Cleaning the reflector Unplug the fixture before attempting to clean the reflector Remove the lamp before attempting to clean the reflector Remove the lens so you can access the reflector from the front of the fixture See Removing a lens on page 6 c um Remove dust with a blast of oil free air or wipe with a clean soft lint free cotton cloth If this is sufficient to remove dust go to step 7 Otherwise continue to s
2. Source Four HID PAR CE User Guide CC DECLARATION OF CONFORMITY We Electronic Theatre Controls Europe Limited Unit 5 Victoria Industrial Estate London W3 6UU United Kingdom declare under sole responsibility that the product Product name Product type model Lot Batch Serial number Item numbers Source Four HID luminaires 405HID 410HID 419HID 426HID 436HID 450HID 41530 HID 42550 HID 426HIDJ 436HIDJ 450HIDJ 2550HIDJ PAR EAHID PARNel HID n a n a one of each type to which this declaration relates is in conformity with the following Standards EN60598 1 2000 EN60598 2 17 1990 BS EN 60922 1997 Luminaires General reguirements and tests Luminaires Particular reguirements Specification for luminares for stage lighting television film and photographic studios outside and indoor eguiv BS 4533 102 17 1990 Auxileries for lamps Ballasts for discharge lamps excluding tubular flu orescent lamps General and safety reguirements Following the provisions of EU LV Directive s 73 23 EEC ENb5015 1996 EN61000 3 2 2001 EN61000 3 2 1995 London United Kingdom Limits and methods of measurement of radio disturbance characteristics of electrical ligthing and similar eguipment Electromagnetic compatibility EMC Limits Limits for harmonic current emissions eguipmetn input current up to and including 16 A per phase Class C Electromagnetic compatibility EMC Limits Limitatio
3. d Pad silicon reflector mount Screw 6350cmx1 9 cm PhPHMS black zinc Clip gel retainer Spring retainer Lens rotation ring Screw 6350 cmx 6350 PhFIMS black zinc Spring clip rotator Plug focus knob Rotator pressure clip Clutch plate black anodized Nut 8 cm Source 4 Par safety screen 5 2 required Quantity Required 1 1 1 English This page intentionally blank Source Four HID PAR CE 11 Americas m 3030 Laura Lane P O Box 620979 Middleton Wisconsin 53562 0979 USA m Tel 608 831 4116 m 800 688 4116 m Fax 608 836 1736 m 800 555 8912 Europe m Unit 4 Victoria Industrial Estate Victoria Road London W3 6UU UK m Tel 44 0 20 8896 1000 m Fax 44 0 20 8896 2000 Asia Room 605 606 Tower Ill Enterprise Square 9 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong m Tel 852 2799 1220 m Fax 852 2799 9325 Web www etcconnect com m Email US mail etcconnect com m UK mail etceurope com m Asia mail etcasia com Service service etcconnect com m Toll free 800 775 4382 m Comments about this document techcomm etcconnect com Copyright 2003 Electronic Theatre Controls Inc All Rights Reserved Product information and specifications subject to change 7061M1015 m Rev A Released 4 03
4. dary suspension point on the Source Four HID PAR CE e Ifthe external cable is damaged it shall be replaced by ETC or our service agents Always hang the Source Four HID PAR CE with the colour frame held securely behind the PAR retaining channel Always replace the lamp if it becomes damaged or thermally deformed e Lighted objects at this distance or greater will not exceed 90 C temperature from projected light Disconnect the unit from power before all cleaning and maintenance The Source Four HID PAR CE is suitable for indoor use with a maximum ambient temperature T 45 C e Maximum exterior surface temperature T 3 200 C Amultilingual label sheet is included with this manual Affix the label of the appropriate language over the existing warning label on the extension yoke Do not cover ETC trademark or CE mark The Source Four HID PAR CE contains a CE safety screen that covers the lens in the event of accidental dis charge Do not remove the safety screen Keep the luminaire at least 0 7 meters away from anything it is shining on dq om E Source Four HID PAR CE 3 English Wiring and power information A plug of at least 2 5 amp 220 240V rating should be attached to the fixture s mains lead The wires in the mains lead are 1 5mm each and coloured in accordance with the following code Green and Yellow Earth Blue Neutral 1 Brown Live WARNING _ The CE Source Four HID PAR CE must be ea
5. down as if to close it until it snaps into place over the tab inside the rotating ring Place the left housing on a flat surface with the lens end pointing to the right Install the lens rotation ring 8 into the left housing 3 5 Install the rotator pressure clip 12 into the left housing 3 with screw 9 and tighten firmly 6 Place the spring 7 on the long end of the gel retainer clip 6 and insert the short end into the left housing 2 Install the reflector 1 into the left housing 3 The reflector must be seated securely on the reflector mount pads behind the ridge Position the reflector with the single orientation tab on the bottom and fit it into the single slot on the base of the left housing The edge of the reflector mount pads should be visible Pull the reflector tight against the edge of the housing Hint This is easier if you hold the left housing with your left hand and put your left index finger through the hole on the back of the reflector Make sure the reflector is seated firmly the orange pads should be visible 10 Attach the right housing 2 to the left housing 3 using the three 6350 cm x 1 9cm screws 5 Make certain the gel retainer clip is in place 11 Check for ease of movement of the gel retainer clip 6 The clip should latch into the left housing in the down position and not bind If it is tight work several times to loosen using channel locks pliers or wrench 12 Ver
6. ed 6 x 22mm Many facets sized 6 x 12mm 21 x 34 Oblong beam shape 30 x 51 Oblong beam shape Changing Source Four HID PAR CE lenses Change lenses if they become cracked or badly scratched Source Four HID PAR CE lenses get hot while the unit is in operation CAUTION Never operate the Source Four HID PAR CE without a lens in place Let the fixture cool before handling the lens Removing a lens 1 Disconnect power to the fixture before handling 2 Place the fixture on a flat stable work surface Do not install or remove lenses with the unit hanging 3 Position the lens rotation ring with the spring clip at the top of the unit directly below the retaining clip 4 Tilt the front of the fixture down at least 45 degrees 5 Press the spring clip with your finger to release the lens Figure 2 6 Allow the lens to drop forward from under the clip 7 When the lens drops remove your finger allowing the lens to slide forward until it rests on the lens catchers Figure 3 8 Carefully remove the lens from the fixture Spring clip hy SC TM Tab pour Lens Retaining clip Figure 2 catcher Figure 3 6 Source Four HID PAR CE English Installing a lens 1 Disconnect power to the fixture before handling 2 Position the fixture with the front of the unit the lens side facing you and tilted slightly Figure 2 3 Position the lens rotation ring with the spring clip at the top of the fixture directly below the
7. glass with your fingers If you touch the lamp during installation clean it carefully with rubbing alcohol and a clean lint free cloth before operation 4 Insert lamp base into socket assembly Figure 1 5 Push down on the lamp base until the lamp seats firmly 6 Reinstall the lamp housing by aligning the bolt hole and tightening the knurled bolt CAUTION Replace the lamp if it becomes damaged or thermally deformed Improperly installed lamps will cause premature lamp and socket failures Figure 1 Ballast information The only acceptable voltage is 120V 10 50 60HZ The standard operating current is 1 5 Amps The standard inrush current is lt 14 Amps Room ambient temperature should not exceed 40 C The lamp ignition voltage is 4 5Kv non hot restrike The ballast case temperature should not exceed 75 C e The ballast is attached to the Source Four yoke by two screws and is non removable WARNING DO NOT power the Source Four HID PAR CE with a dimmable power supply Dimming will damage the ballast and void the warranty Source Four HID PAR CE 5 English Lens identification Lenses for the Source Four HID PAR CE come in four versions The type or beam spread can be identified by the lens texture VNSP Very narrow spot Narrow spot Clear glass Stipple glass slight diffuse texture 15 Round beam shape 19 Round beam shape MFL Medium flood Wide flood Fewer facets siz
8. ify that the lens rotation ring rotates smoothly but does not spin loosely 13 Snap the focus knob plug 11 into the bottom of the fixture assembly as shown in the Source Four HID PAR CE Housing Assembly diagram on page 6 8 Source Four HID PAR CE English Spare parts list 13 14 Source Four HID PAR CE Final Assembly Reference Number 1 10 11 12 13 14 Part Number 7061A2022 7061A2022 1 7061A2203 0X 7061A2203 1X 7061A3039 7061A3039 1 HW5125 HW5126 HW5139 HW5172 HW5270 HW522 HW8144 HW8144 1 Description S4 HID PAR base assembly black S4 HID PAR base assembly white CE HID PAR Lamp socket assembly black CE HID PAR Lamp socket assembly white HID PAR yoke bracket black HID PAR yoke bracket white Bolt carriage Washer flat Washer split ring lock Bolt hex Bolt spinlock Washer flat Handle yoke knob black Handle yoke knob white Quantity Required 1 N N N mM Source Four HID PAR CE 9 English Spare parts list Source Four HID PAR CE Housing Assembly Reference Number 1 2 3 4 10 11 12 13 14 not pictured 10 Source Four HID PAR CE Part Number 7061A3014 7061A3025 7061A3026 7061A4001 HW391 7061A3005 HW750 7060A4012 HW3106 7061A3013 HW6128 7061A3029 7061A3031 HW402 7061A1030 Description Reflector EA painted Housing right PAR painted Housing left PAR painte
9. n of voltage fluctua tions and flicker in low voltage supply systems for eguipment with rated current lt 16 A Adam Bennette Place of issue 13th December 2002 date of issue Electronic Theatre Controls Europe Ltd Unit 5 Victoria Industrial Estate Victoria Road London W3 6UU U K Name of authorised person gt hd beable signature of authorized person Registered office Grant Thornton House Melton St London NW1 2BW England English Source Four HID PAR CE guidelines Please note the following precautions prior to use The Source Four HID PAR CE is intended for professional use only Read the entire User Guide before using eguipment Please note the following safety precautions e The Source Four HID PAR CE is NOT dimmable Dimming or regulated voltage will damage the ballast and void the warranty Do not mount the Source Four HID PAR CE on or near a flammable surface Use the Source Four HID PAR CE in dry locations only where humidity does not exceed 90 percent e The fixture is for indoor use only and is not intended for outdoor use For temporary installations mount and support the Source Four HID PAR CE only by the primary suspension yoke holes Suspend the fixture from a hook clamp or a stand mount using a securely tightened steel bolt up to 12 mm flat washer and locking washer n addition to primary suspension attach a safety cable Model 400SC or chain to the secon
10. rthed Current rating 240V 2 5 amp maximum Operating fre 50 60Hz quency Accessories ETC Part Colour frame 19 cm sq 17 cm inside diameter 7061A3047 Safety cable 79 cm 7061A1022 C clamp 7060A2009 Top hat 7 62 cm PSF1022 Top hat 15 24 cm PSF1023 Half hat PSF1027 Cross baffle top hat PSF1031 Egg crate louver PSF1028 Weighted base PSF1032 Gel Extender 7 62 cm PSF1030 Gel Extender 15 24 cm PSF1029 Barn door PSF1019 HID Lamp type and general information Do not use lamps other than the following types in the Source Four HID PAR CE Use of lamps other than speci fied below will void CE safety compliance and your warranty Lamp Type Manufacturing Codes Watts Base Bulb LCL Ave lnitial Color Hrs lumens temp CDM T 150W 830 150 G12 T6 56mm 9000 14000 3000 K CDM T 150W 942 150 G12 T6 56mm 9000 12700 4000 K Ceramic Metal be 150 012 T6 56mm 9000 14000 3000 K Halide ss 1 __ MBI150 T 30 150 012 T7 57mm 6000 11500 3000 K MBI150 T 40 150 G12 T7 57mm 6000 11250 4000 K 4 Source Four HID PAR CE English Installing the lamp 1 Disconnect power to the Source Four HID PAR CE before installing the lamp 2 Loosen the knurled bolt on the back of the lamp housing and pull the housing out 3 Holding it by the base remove the lamp from its box Note To avoid premature lamp failure do not touch the lamp
11. tep 5 m Dampen a clean soft lint free cotton cloth with a mild soapy water solution and gently wipe the reflector 6 Remove any soapy water residue with a clean soft lint free cotton cloth dampened with water Reinstall a lens before using the fixture CAUTION _ Do not use glass or window cleaners on the reflector Chemicals in the cleaners will harm the reflective coating Do not use paper towels or harsh materials to wipe the reflector These materials can scratch the surface of the reflector Source Four HID PAR CE 7 English Housing assembly instructions If you take apart the Source Four HID PAR CE for any reason please use the following steps for reassembly Improper reassembly will result in void of warranty and loss of performance Tools required Phillips and flat head screwdrivers rubber mallet channel locks pliers or crescent wrench 1 Install the clutch plate 13 onto the left housing 3 and secure with nut 14 The right housing has three screw holes on its side and one hole for the yoke bolt The left housing only has two bolt holes for the yoke Install the four reflector mount pads 4 in the right 2 and left 3 housing There are two recessed places in each housing for the pads Insert the spring clip 10 with the open end facing the lamp into the lens rotation ring 8 Place a flathead screwdriver in the spring clip slot and gently tap with a rubber mallet Using your finger press the clip
Download Pdf Manuals
Related Search
Related Contents
Samsung En Güçlü Emiş özelliğine sahip SC8200 Filtreli Elektrik Süpürgesi, 2400 W Kullanıcı Klavuzu (Windows 7) aero 12 / User`s Manual - DAS Audio Télécharger ce fichier Copyright © All rights reserved.
Failed to retrieve file