1. CEAG Explosionsgesch tzte Leuchten f r Zone 2 und Zone 22 Serie nLLK 10 Explosion protected light fittings zone 2 and zone 22 Series nLLK10 Luminaires pour atmospheres explosives zone 2 et zone22 S rie nLLK10 3 3465 000 170 D E F a Betriebsanleitung Operating instructions W foxe me M an e e COOPER Crouse Hinds CZ Tento n vod k pou it si m Zete vy dat ve sv m mate sk m jazyce u p slu n ho zastoupen spole nosti Cooper Crouse Hinds CEAG ve va zemi DK Montagevejledningen kan overs ttes til andre EU sprog og rekvireres hos Deres Cooper Crouse Hinds CEAG leverand r E En caso necesario podra solicitar de su representante Cooper Crouse Hinds CEAG estas instrucciones de servicio en otro idioma de la Union Europea EST Seda kasutusjuhendit oma riigikeeles v ite k sida oma riigis asuvast asjaomasest Cooper Crouse Hindsi CEAG esindusest FIN Tarvittaessa t m n k ytt ohjeen k nn s on saatavissa toisella EU n kielell Teid n Cooper Crouse Hinds CEAG edustajaltanne GR Eav xpe ao e peta paon Twv OONyIWV XPNOE WG o GAAN YAwooa me EE utope va Intndei ato Tov AVTITPOOWITTO TNG Cooper Crouse Hinds CEAG H A kezel si tmutat t az adott orsz g nyelv n a Cooper Crouse Hinds CEAG c g helyi k pviselet n ig nyelheti meg l Se desiderate la traduzione del manuale operativo in un altra lingua della Comunit Europea potete richieder
2. 7 3 kg 4 Installation N Die f r das Errichten und Betreiben von elektrischen Betriebsmitteln gelten den Sicherheitsvorschriften und des Ger tesicherheitsgesetzes sowie die allgemein anerkannten Regeln der Technik sind einzuhalten Transport und Lagerung der Leuchte ist nur in Original verpackung und in angegebener Lage gestattet T5 Lampen 16 mm werden am Lebensdauerende von der EOLSchaltung als fehlerhaft erkannt und abgeschaltet nLLK 10 Bei besonderen Umwelteinfl ssen wird empfohlen den Entl ftungsstutzen GHG960 1954 R0002 zu verwenden Die Leuchte mit der Vorzugsleuchtrichtung nach unten montieren 4 1 Offnen und Schlie en der Leuchte CT Den Zentralverschluss mit Steckschl ssel Schl sselweite SW 13 um ca 90 bis zur Raststellung drehen und Schutzwanne abklappen siehe Bild 3 Schutzwanne ein und ausbauen siehe Bild 6 und 7 J Die Schutzwanne ist wahlweise beidseitig scharnierbar CT Schutzwanne zum Verschlie en der Leuchte fest an das Leuchtengeh use andr cken und den Zentralverschluss um 90 drehen 4 2 Montageabmessungen siehe Bild 2 Beachten Sie beim Befestigen des Montage zubeh rs an der Leuchte die max Gewinde tiefe der Montagebohrung von 12 mm Verwenden Sie keine zu langen Schrauben Montagezubeh r siehe CCH CEAG Katalog 4 3 Netzanschluss Zum ffnen des Anschlussraumes gr nen Drehgriff in Pfeilrichtung bis zum Anschlag drehen dann ziehen und d
3. BVS 10 ATEX E 149 Kennzeichnung nach 94 9 EG und Norm Gas II 3G Ex nA de IIC T4 Gc Staub amp Il 3D Ex tc IIIC T80 C Dc IP66 Bemessungsspannung Konformitatserklarung 220 V 240 V AC 220 V 240 V DC Bemessungsfrequenz 50 60 Hz Lampenbest ckung Leuchtstofflampen T5 16 mm nach 14WHE IEC 60081 28 W HE IEC 60081 35 W HE IEC 60081 Schutzart nach EN IEC 60529 IP 66 Schutzklasse nach EN IEC 61140 zul Umgebungstemperatur nLLK 10 14 14 25 C bis 50 C nLLK 10 28 28 25 C bis 50 C nLLK 10 35 35 25 C bis 45 C mit Durchgangsverdrahtung nLLK 10 14 14 25 C bis 45 C nLLK 10 28 28 25 C bis 45 C nLLK 10 35 35 25 C bis 40 C Lagertemperatur in Originalverpackung 40 C bis 60 C Klemmverm gen Schraub Anschluss klemme 2x je Klemme einadrig mehradrig min 1 5 mm 1 5 mm max 6 0 mm 6 0 mm Leiterquerschnitt bei Durchgangs verdrahtung 2 5 mm f r max 16A Leitungseinf hrung Kunststoff M25 x 1 5 f r Leitungen 8 bis 17 mm Metallgewinde M20 x 1 5 A Nur f r festverlegte Leitungen Pr fdrehmoment f r Kabel und Leitungs einf hrung M25 x 1 5 5 0 Nm Pr fdrehmoment f r Entl ftungsstutzen M25 x 1 5 10 0 Nm Pr fdrehmoment f r Druck schraube f r min Kabel 5 00 Nm f r max Kabel 3 50 Nm Leuchten und Montage abmessungen siehe Bild 2 Leuchtengewichte nLLK 10 14 14 ca 4 0 kg nLLK 10 28 28 ca 6 0 kg nLEK 1035 35 ca
4. fixation voir fig 2 Respecter lors de la fixation des accessoires de montage au luminaire que les trous de fixation doivent avoir une profondeur du pas de 12 mm au maxi Ne pas utiliser de vis trop longues Accessoires pour le montage voir le catalogue CCH CEAG 4 3 Branchement sur secteur Afin d ouvrir la bo te de connexion tourner la poign e rouge jusqu sa but e puis la tirer et rabattre la trappe voir Introduire le c ble par l entr e de c ble voir fig 4 et 5 Utiliser c bles avec conducteur en cuivre pour connexion au r seau L air et les lignes de fuite l int rieur du luminaire ont t con us pour r sister un degr d encrassement 2 EN CEI 60644 EN CEI 60598 1 EN CEI 60079 0 6 1 remarque 3 Lors du raccordement du luminaire avec le c ble souple s assurer d avoir la bonne d charge de traction raccords filet s vas s avec au minimum l indice de protection IP66 Cooper Crouse Hinds GmbH 7 G n ralement seuls des bouchons de fermeture et des entr es de c ble certifi s peuvent tre utilis s Pour garantir le mode de protection contre l inflammation nA utiliser uniquement des bornes avec au minimum l ndice de protection IP66 Respecter le mode d emploi du fabricant NEn cas d entr es de c ble non utilis es leur disque protecteur doit tre enlev et l entr e doit tre ferm e avec un bouchon de fermeture couple de 3 5 Nm Lorsqu un
5. technischen Daten sind zu beachten Betriebsmittel vor ffnen spannungs frei schalten Mehrfaches kurzzeitiges Einschalten vermeiden Umbauten oder Ver nderungen an der Leuchte sind nicht zul ssig Die Leuchte ist bestimmungsgem in unbesch digtem und einwandfreiem Zustand zu betreiben Als Ersatz d rfen nur Originalteile von Cooper Crouse Hinds CCH CEAG verwendet werden Reparaturen d rfen nur von CCH CEAG oder einer qualifizierten Elektrofachkraft durchgef hrt werden Betriebsanleitung w hrend des Betriebes nicht in der Leuchte belassen 2 Normenkonformit t Diese explosionsgesch tzte Leuchte entspricht den aufgef hrten Normen in der separat beigelegten Konformit tserkl rung und ist gem ss DIN EN ISO 9001 2008 entwickelt gefertigt und gepr ft Diese Leuchte ist zum Einsatz in explosions gef hrdeten Bereichen der Zonen 2 22 gem EN IEC 60079 10 1 und 2 geeignet 1 Intensive Sonneneinstrahlung in Regionen mit hohen Umgebungstemperaturen kann im Leuchteninneren zu unzul ssig hohen Erw rmungen f hren Eine Reduzierung der Lebensdauer des EVGs kann eine Folge hiervon sein Zur Vermeidung sollten in diesen Regionen tags ber die Leuchten ber einen Lichtsensor geschaltet werden P COOPER Crouse Hinds 3 Technische Daten Leuchten mit Zweistiftlampenfassung G5 nLLK 10 14 14 2X14WHE nLLK 10 28 28 2 x 28 W HE nLLK 10 35 35 2 x 35 W HE Baumusterprufbescheinigung
6. ventives appropri es Il n est pas permis de transformer ou de modifier le luminaire Le luminaire ne doit tre exploit que pour la fonction qui lui est d volue et qu en tat intact et parfait Seules des pi ces de rechange d origine CEAG doivent tre employ es pour le remplacement Des r parations ne doivent tre ex cut es que par CEAG ou par un lectricien qualifi Ce mode d emploi ne doit pas tre laiss dans le luminaire pendant son exploitation 2 Conformit avec les normes Ce luminaire pour atmosph re explosive correspond aux exigences de la norme reprises dans la d claration de conformit jointe s par ment et aux r gles instructions de CE appareils et systemes prot g s pour l emploi d termin en atmosph re explosive 94 8 CE et compatibilit electromagnetique 2004 108 CEE ll a t con u construit et test selon l tat actuel de la technique et selon DIN EN ISO 9001 2008 Ce luminaire convient a l utilisation en atmosph re explosive de zone 2 et 22 selon EN CEI 60079 10 1 et 2 Le rayonnement solaire intensive dans des r gions temp rature ambiante lev e peut provoquer l int rieur du luminaire un chauffement extensif Ceci peut impliquer une r duction de dur e de vie consid rable Pour pallier cela il est pr coniser d utiliser un interrupteur photo lectrique P COOPER Crouse Hinds 3 Caract ristiques techniqu
7. bouchon de fermeture est mis toujours utiliser les deux joints d tanch it Introduire le cable par l entr e de cable voir fig 5 Utiliser les deux joints d tanch it pour les cables de 8 a 12 mm et le joint ext rieur seul pour les cables de 12 a 17 mm Veiller au propre logement du joint d tancheit demeur dans la presse toupe Connecter les c bles aux bornes PE N L1 L2 L3 suivant le rep rage des bornes voir sch ma des connexions sur page 3 D nudage des conducteurs 8 9 mm En cas d occupation simple de la borne il n est pas n cessaire de replier le conducteur boucle Serrer aussi les bornes non utilis es 4 4 Mise en place de la lampe AN utiliser que des HE lampes homologu es pour ces luminaires voir Caract ristiques techniques et plaque signal tique Introduire la lampe double broche G5 jusqu sa but e dans les deux douilles de mani re que les deux broches de chaque c t de la lampe soient prises par la douille Puis tourner la lampe en position de crantage selon fig 9 AAttention Remplacement de la lampe uniquement hors tension 5 Mise en service Avant la mise en service des luminaires il faut v rifier s ils sont branch s et fonctionnent en conformit avec ce mode d emploi et avec d autres r glements applicables Des mesures d isolation ne doivent tre effectu es ou entre PE et le conducteur ext rieur L1 L2 L3 ainsi qu entre PE e
8. device with a box spanner opening of the spanner SW 13 through 90 to its lock in position and fold down the protective bowl see fig 3 1 Fit in and remove the protective bowl acc to fig 6 and 7 J The protective bowl can at option be hinged on either side To close the light fitting press the protective bowl tightly onto the luminaire housing and turn the central locking device through 90 4 2 Mounting dimensions see fig 2 When fixing the mounting accessories onto the light fitting observe the max depth of thread of 12 mm Do not use too long screws Installing the light output upwards additional protection has to be assembled to avoid permanent water accumulations at the protective bowl gasket area Accessories for mounting See CCH CEAG catalogue 4 3 Mains connection To open the connection box turn the green handle to its stop in the direction of arrow then pull it and fold down the flap see fig 4 5 For power connection use cables with copper conductor O The air and creep distances inside the light are designed for soiling level 2 EN IEC 60644 EN IEC 60598 1 EN IEC 60079 0 6 1 Note 3 O When connecting the light to a flexible cable ensure the correct strain relief trumpet screw with at least IP66 protection class Only cable entries and sealing plugs certified to 94 9 EC may be used To guarantee protection type nA use only cable entries with at least IP66 protection c
9. e lampes 7 R paration Avant de remplacer ou d enlever des composants il faut observer le mode suivant Mettre l appareil hors tension avant de l ouvrir ou de le r parer N utiliser que des pieces de rechange approuv es d origine CCH CEAG Voir liste des pi ces de rechange CCH CEAG Sous r serve de modification ou de suppl ment de cette s rie de produits Quant l enl vement des d chets veuillez respecter la r glementation nationale en vigueur Quant l enl vement des d chets veuillez respecter les r glements nationaux respec tifs gen vorbehalten 3 3465 000 170_a D E 51 12 St Technische Anderun Betriebsanleitung g ltig ab 51 2012
10. es Luminaires avec douille de lampe double broche G5 nLLK 10 14 14 2x14W nLLK 10 28 28 2 x 28 W nLLK 10 35 35 2x35 W Certificat d essai CE du mod le type CE Declaration de Conf BVS 10 ATEX E 149 Marquage selon directive 94 9 CE Gaz x 11 3G Ex nA de IIC T4 Gc Poussi re II 3D Ex tc IIIC T80 C Dc IP66 Lampes 4a utiliser Lampes fluorescentes a T5 16 mm 14 W HE CEI 60081 28 W HE CEI 60081 35 W HE CEI 60081 Indice de protection selon EN CEI 60 529 IP 65 Classe d isolation selon EN CEI 61140 Temp rature ambiante admissible 1 nLLK 10 14 14 25 C 50 C nLLK 10 28 28 25 C 50 C nLLK 10 35 35 25 C 45 C pour l interconnexion nLLK 10 14 14 nLLK 10 28 28 25 C 45 C nLLK 10 35 35 25 C 40 C Temp rature de stockage dans l emballage original 40 C 60 C Capacit de serrage des bornes sans vis 25 C 45 C 2 x par bornes a visser unifilaire multifilaire min 1 5 mm 1 5 mm max 6 0 mm 6 0 mm Section transversale du conducteur en cas d interconnexion 2 5 mm pour 16A au maxi Entr e de cable en plastique modele standard M25x1 5 pour cables d un de 8 17 mm Entr es de c ble en m tal M20 x 1 5 Couple pour l entr e de c ble M25 x 1 5 5 0 Nm Couple pour la vis de pression 3 5 Nm pour tan cher le c ble ou le bouchon de ferme ture Dimensions des luminaires et de fixation voir fig 1 Poids des lumina
11. hen PE und N durchgef hrt werden Me spannung max 1kVAC DC Me strom max 10 mA CT Die Leuchte nur im geschlossen betrieben nLLK 10 6 Instandhaltung N Die f r die Instandhaltung Wartung und Pr fung die geltenden Bestimmun gen sind einzuhalten zum Beispiel EN IEC 60079 17 Wartung Im Rahmen der Wartung sind vor allem die Teile von denen die Schutzart abh ngt zu pr fen z B J Geh use und Schutzwannen auf Risse und Besch digungen CT Dichtungen auf Besch digungen J Klemmen Verschraubungen und Verschlussstopfen auf festen Sitz CT Wegen der Gefahr elektrostatischer Aufladung darf die Leuchte nur mit einem feuchten Tuch oder Schwamm gereinigt werden Benutzen Sie dazu nur bliche Haushaltssp lmittel in vorgeschriebener Verd nnung mit Wasser Die Wassertemperatur darf maximal 50 C betragen Sp len Sie anschlie end mit klarem Wasser nach da sonst Spannungsrisse in der Schutzwanne entstehen k nnen CT Beachten Sie f r den Lampenwechsel die Wechselintervalle gem Vorgabe der Lampenhersteller 7 Instandsetzung N vor dem Austausch oder der Demon tage von Einzelteilen ist folgendes zu beachten Schalten Sie das Betriebsmittel vor dem ffnen oder vor Instandhaltungsarbeiten erst spannunstfrei Verwenden Sie nur CCH CEAG Originaler satzteile siehe CCH CEAG Ersatzteilliste Programm nderungen und Erg nzungen sind vorbehalten Bei der Entsorgung nationale Abfallbesei t
12. ie Klappe ab Klappen siehe Bild 4 und 5 F r den Netzanschluss Leitungen mit Kupferadern verwenden CT Die Luft und Kriechstrecken im Inneren der Leuchte sind f r den Verschmutzungsgrad 2 ausgelegt EN IEC 60644 EN IEC 60598 1 EN IEC 60079 0 6 1 Anmerkung 3 CT Beim Anschlie en der Leuchte mit flexibler Leitung ist auf entsprechende Zugentlastung zu achten Trompetenverschraubungen mit mind Schutzart IP66 Es d rfen nur nach 94 9 EG bescheinigte Kabel und Leitungseinf hrungen KLE s und Verschlussstopfen verwendet werden Um die Z ndschutzart nA zu gew hr leisten nur KLES mit der Mindestschutzart IP66 verwenden Die entprechende Betriebsanleitung des Herstellers ist zu beachten A Bei nicht benutzten Kabel und Leitungseinf hrungen ist die Schutz scheibe zu entfernen und durch einen bescheinigten Verschlussstopfen Pr f drehmoment 3 5 Nm zu verschlie en Beim Verschlie en mit einem Verschluss stopfen stets beide Dichtungseins tze verwenden mindestens Schutzart IP66 Nicht benutzte Gewindebohrungen f r KLEs sind mit einem bescheinigten Schraubverschluss zu verschlie en mindestens Schutzart IP66 Cooper Crouse Hinds GmbH 3 Cooper Crouse Hinds GmbH Die Leitungen sind durch die Kabel und Leitungseinf hrung einzuf hren siehe Bild 5 g F r Leitungen von 8 bis 12 mm sind beide Dichtungseins tze von 12 bis 17 mm ist nur der uBere Dichtungseinsatz zu verwenden Der korre
13. igungsvorschriften beachten Die Kunststoff materialien sind mit Materialbezeichnungen versehen P COOPER Crouse Hinds 1 Safety instructions For skilled electricians and trained personnel in accordance with national legislation including the relevant standards and where applicable in acc with IEC 60079 14 on electrical apparatus for explosive atmospheres Observe the national safety rules and regulations for prevention of accidents and the following safety instructions which are marked with an A in these operating instructions O The light fitting is not suitable for use in hazardous areas of zone 0 1 and zone 20 21 The requirements of the EN IEC 60079 31 regarding excessive dust deposits and temperature to be considered from the user The technical data indicated on the light fitting are to be observed Disconnect equipment before opening Avoid powering up repeatedly for short periods of time Changes of the design and modifications to the light fitting are not permitted The light fitting shall be operated as intended and in undamaged and perfect condition Only genuine Cooper Crouse Hinds CCH CEAG spare parts may be used for replacement Repairs may only be carried out by CCH CEAG or a qualified electrician Do not keep these operating instructions inside the light fitting during operation 2 Conformity with standards This explosion protected light fitting meets the requi
14. ires nLLK 10 14 14 ca 4 0 kg nLLK 10 28 28 ca 6 0 kg MELK 1035 35 ca 7 3 kg nLLK 10 4 Installation A Lors de l installation et de exploitation des appareils lectriques les r glements nationaux ainsi que les r gles de la technique g n ralement reconnues doivent tre respect s Le transport et le stockage ne sont permis que dans l emballage original et dans la position sp cifi e AMise en place de la lampe Respectez les consignes de s curit par le fabricant de lampes N utiliser que des lampes homologu es pour ces luminaires voir Caract ristiques techniques et plaque signal tique Les lampes T5 16 millim tres la fin de leur vie sera d tect en tant que d fectueux et d coup par l EOL circuit L environnement dans un tat sp cial qu il pourrait tre n cessaire d utiliser une respiration et bouchon de drainage GHG960 1954 R0002 4 1 Ouverture et fermeture du luminaire Tourner le verrou central avec la cl a douille ouverture de cl SW 13 de 90 dans sa position de crantage et rabattre la vasque de protection voir fig 3 et 4 Monter et d monter la vasque de protection suivant fig 6 et 7 La vasque de protection est pourvue d une charni re des deux c t s ce qui permet de la suspendre de chaque c t Pour fermer le luminaire presser la vasque de protection contre le bo tier du luminaire et tourner le verrou central de 90 4 2 Dimensions de
15. king 40 C up to 60 C Supply terminal clamping capacity 2x per screw terminal single wire multi wire min 1 5 mm 1 5 mm max 6 0 mm 6 0 mm Conductor cross section with through wiring 2 5 mm for max 16 A Cable entries moulded plastics 25 C up to 45 C 25 C up to 45 C 25 C up to 40 C M25x1 5 for cable 8 to 17 mm Metal thread M 20 x 1 5 For permanently laid cables only Test torque for M25 x 1 5 cable entry 5 0 Nm Test torque for pressure screw 3 5 Nm for sealing off the cable or the blanking plug Dimensions of light fittings and for mounting see fig 2 nLLK 10 14 14 ca 4 0 kg nLLK 10 28 28 ca 6 0 kg ALEK 1035 35 ca 7 3 kg 4 Installation N Observe the respective national regulations as well as the general rules of engineering which apply to the installation and operation of electrical apparatus Transport and storage of the luminaire is permitted in original packing and specified position only Observe the safety instructions of the lamp manufacturer A Only use such lamps that have been certified for these light fittings see technical data and type label T5 lamps 16 mm at their lifes end will be detected as faulty and will be cut off by the EOL circuit In special environment condition it could be necessary to use a breathing and drainage plug GHG960 1954 R0002 nLLK 10 4 1 Opening and closing the light fitting O Turn the central locking
16. kten Sitz des verbleibenden Dichtungseinsatzes in der Verschraubung muss sichergestellt sein O Die abisolierten Leitungen gem Klemmenbezeichnung siehe Schaltplan Seite 2 sind in die Steckklemmen einzufuhren Abisolierlange 2 5 mm 8 9mm CT Bei Verwendung von mehr oder feindrahtigen Anschlussleitungen sind die Aderenden entsprechend den geltenden nationalen und internationalen Vorschriften zu behandeln z B Verwenden von Aderendh lsen Sind Schraubklemmen vorhanden m ssen auch nicht benutzte Klemmen angezogen werden Bei Einfachbelegung der Klemmen kein Umbiegen Schlaufe der Adern notwendig 4 4 Einsetzen der Lampen Ah Nur HE Lampen gem den techni schen Daten und dem Typenschild einsetzen Keine HO Lampen mit gleichen Abmessungen verwenden Die Zweistiftsockellampe G5 in beide Fas sungen bis zum Anschlag einstecken so dass an jeder Seite der Lampe beide Stifte im Ein griff der Fassung sind Danach die Lampe in Raststellung drehen siehe Bild 8 und Bild 9 N Achtung Lampenwechsel nur im ausgeschalteten Zustand Option automatische Abschaltung ber 2 poligen Leuchtenschalter beim ffnen der Schutzwanne 5 Inbetriebnahme g Vor der Inbetriebnahme ist die korrekte Funktion und Installation der Leuchte in bereinstimmung mit dieser Betriebsanleitung und anderen zutreffenden Bestimmungen zu berpr fen g Isolationsmessungen d rfen nur zwischen PE und AuBenleiter e L1 L2 L3 sowie zwisc
17. la al vostro rappresentante Cooper Crouse Hinds CEAG LT ios naudojimo instrukcijos i verstos J s gimtaja kalb galite pareikalauti atsakingoje Cooper Crouse Hinds CEAG atstovybeje savo alyje LV o ekspluat cijas instrukciju valsts valod varat piepras t jusu valsts atbildigaj Cooper Crouse Hinds CEAG p rst vniec b M Jistg u jitolbu dan il manwal fil lingwa nazzjonali tag hom ming and ir rappre entant ta Cooper Crouse Hinds CEAG f pajji hom NL Indien noodzakelijk kan de vertaling van deze gebruiksinstructie in een andere EU taal worden opgevraagd bij Uw Cooper Crouse Hinds CEAG vertegenwoordiging COOPER Crouse Hinds GmbH Neuer Weg Nord 49 D 69412 Eberbach Germany Fone 49 0 6271 806 500 Fax 49 0 6271 806 476 Internet http www CEAG de E Mail sales cch de cooperindustries com P Se for necess ria a tradu o destas instrug es de operag o para outro idioma da Uni o Europeia pode solicita la junto do seu representante Cooper Crouse Hinds CEAG PL Niniejszainstrukcj obs ugi w odpowiedniej wersji j zykowej mo na zam wi w przedstawicielstwie firmy Cooper Crouse Hinds CEAG na dany kraj S En vers ttning av denna montage och sk tselinstruktion till annat EU spr k kan vid behov best llas fr n Er Cooper Crouse Hinds CEAG representant SK Tento n vod na obsluhu V m vo Va om rodnom jazyku poskytne zast penie spolo nosti Cooper C
18. lass The corresponding manufacturer s Operating Manual must be observed Where cable entries are not used the protective glass must be removed and sealed with a certified sealing plug test torque 3 5 Nm If sealing with a sealing plug always use both sealing inserts IP66 Unused threaded holes for cable entries are sealed with a certified screw plugscrew IP66 Cooper Crouse Hinds GmbH 5 Cooper Crouse Hinds GmbH CT Introduce the cable through the cable entry see fig 5 g Use both sealing inserts for cables from 8 to 12 mm and the outer sealing insert only for cables from 12 to 17 mm Pay attention to the proper fit of the sealing insert remaining in the cable gland g Plug the bared conductors to the terminals in accordance with the terminal marking see wiring diagram page 2 stripping length 2 5 mm 8 9mm O When screw terminals are used also tighten vacant terminals With single connection of the terminal no bending loop of the conductor required g If screw terminals are fitted unused terminals must also be tightened With single component terminals the wires do not need to be bent loop 4 4 Fitting the lamps N Only use HE lamps that have been certified for these light fittings see Technical data and type label The bi pin lamp G5 is to be inserted to its stop into both holders so that both pins on either side of the lamp engage in the holder Then turn the lamp to its lock in po
19. rements of the standards specified in the EC Declaration of conformity enclosed separately It has been designed manufactured and tested according to the state of the art and according to DIN EN ISO 9001 2008 The light fitting is suitable for use in hazardous areas of zone 2 22 according IEC EN 60079 10 1 and 2 0 Intensive sun radiation in areas of high ambient temperatures may cause inadmissible temperature rise inside of the luminaire This may result a decrease in lifetime of the electronic ballast EVG Therefore those luminaires should be switched off during daytime by a photocell control P COOPER Crouse Hinds 3 Technical data Light fittings with G5 bi pin cap nLLK 10 14 14 2 x14 W HE nLLK 10 28 28 2 x 28 W HE nLLK 10 35 35 2 x 35 W HE Statement of Confirmation EC Declaration of conf BVS 10 ATEX E 149 Marking accd 94 9 EC and directive Gas II 3G Ex nA de IIC T4 Gc Dust II 3D Ex tc IIIC T80 C Dc IP66 Rated voltage see table 1 Rated frequenzy 50 60 Hz Lamps to be fitted Fluorescent lamps T5 16 mm 14 W HE IEC 60081 28 W HE IEC 60081 35 W HE IEC 60081 Protection acc to EN IEC 60529 IP 66 Insulation class to EN IEC 61140 max permissible ambient temperature nLLK 10 14 14 25 C up to 50 C nLLK 10 28 28 25 C up to 50 C nLLK 10 35 35 25 C up to 45 C with through wiring nLLK 10 14 14 nLLK 10 28 28 nLLK 10 35 35 Storage temperature in original pac
20. rouse Hinds CEAG vo Va ej krajine SLO Navodila za uporabo v Va em jeziku lahko zahtevate pri pristojnem zastopni tvu podjetja Cooper Crouse Hinds CEAG v Va i dr avi Schaltplan Montagebilder Wiring diagrams Illustrations for mounting ol schwarz black schwarz black schwarz black schwarz black blau blue gr n gelb green yellow Lampe lamp 1 Schwarz black Schwarz black gr n gelb green yellow Schwarz black Schwarz black amp zz Wei white optional option Lampe lamp 2 732 14W 1332 28 W 1632 35 W 400 14 W ad 70028W M8 nLLK S 08 700 35W 12 tief deep profond KT Sechskant Hexagon SW13 6 max 8 5 9 5 m 1 DV zweiseitige Durchgangsverdrahtung 1 Sicherheitshinweise Zielgruppe Elektrofachkrafte und unterwiesene Personen nach EN IEC 600079 14 Beachten Sie die nationalen Unfall verh tungs und Sicherheitsvor schriften und die nachfolgenden Sicherheitshinweise die in dieser Betriebsanleitung mit einem gekennzeichnet sind CT Diese Leuchte darf nicht in explosions gef hrdeten Bereichen der Zonen 0 1 und 20 21 eingesetzt werden Die Anforderungen der EN IEC 60079 31 in Bezug auf berm ige Staubablagerungen und Temperatur sind vom Anwender zu beachten Die auf der Leuchte angegebenen
21. sition see fig 8 Attention Lamp exchange must be carried out while energy is switched off Option automatic double pole switch while opening the protective bowl 5 Taking into operation CT Prior to operation check the light fitting for its proper functioning and installation in compliance with these operating instructions and other applicable regulations CT Only carry out insulation measurements between PE and the external conductor L1 L L2 L3 as well as between PE and N measuring voltage max 1 kV AC DC measuring current max 10 mA CT Die Leuchte nur im geschlossen betrieben nLLK 10 6 Maintenance N Observe the national regulations applicable to the maintenance servicing and test of electrical apparatus as well as the general rules of engineering e g EN IEC 60079 17 Servicing When servicing in particular those compo nents that affect the type of protection will have to be checked e g Housing and protective bowl for any cracks or damages Gaskets for their perfect condition J Terminals and blanking plugs for their firm fit Because of the risk of an electrostatic charge the light fitting shall only be cleaned with a damp cloth or sponge Only use customary household washing up liquid diluted in water as specified The water temperature may be max 50 C After that rinse with clear water to prevent the risk of tension cracks in the protective bowl g Lamp replacemen
22. t Keep replacement intervals as specified by the lamp manufacturer 7 Repair N Prior to replacing or removing any components observe the following Cut the apparatus off the voltage before opening it or carrying out repairs Only use certified genuine CCH CEAG spare parts See CCH CEAG spare parts list Subject to alteration or supplement of this product series Regarding waste disposal observe the relevant national regulations All components are marked with relevant material signs P COOPER Crouse Hinds 1 Consignes de s curit Pour le personnel lectricien qualifi et le personnel instruit suivant la r glementation l gale y compris les normes respectives ainsi que le cas ch ant CEI 60079 17 pour apppareils lectriques utilisables en atmosph re explosive Veuillez respecter les prescriptions nationales de s curit et de pr voyance contre les accidents ainsi que les consignes de s curit qui sont marqu es d un dans ce mode d emploi Ce luminaire ne convient pas a l emploi en atmosph re explosive de zones 0 1 et 20 21 Les exigences des EN CEI 60079 31 en ce qui concerne des d p ts de poussi re d mesur s et une temp rature doivent tre consid r es par l utilisateur Les caract ristiques techniques indiqu es sur le luminaire doivent tre respect es Avant d ouvrir enveloppe d brancher le dispositif de la tension ou prendre des mesures pr
23. t N tension de mesure 1 kV CA CC au maxi courant de mesure 10 mA au maxi COOPER Crouse Hinds GmbH Neuer Weg Nord 49 D 69412 Eberbach Germany Fone 49 0 6271 806 500 Fax 49 0 6271 806 476 Internet http www CEAG de E Mail sales cch de cooperindustries com 6 Entretien NEn ce qui concerne l entretien le test et la r eparation des appareils lectriques pour atmosphere explosive les r glements nationaux y applicables par exemple CEI 60079 17 ainsi que les r gles de la technique g n ralement reconnues devront tre respect s Entretien Lors de l entretien surtout les composants dont d pend le mode de protection doivent tre v rifi par ex Le bo tier et la vasque de protection pr sentent ils des fissures ou des signes d avarie Les joints d echanteite sont ils efficaces Les bouchons d obturation et les bornes sont ils bien serr s Vu le risque d une charge lectrostatique le luminaire ne doit tre nettoy qu avec un chiffon humide et non fibreux ou qu avec une ponge Utiliser uniquement un d tergent m nager dilu avec de l eau comme prescrit La temp rature de l eau ne doit pas d passer 50 C au maxi Rincer ensuite l eau claire afin d viter que n apparaissent des fissures dues la contrainte exerc e sur la vasque de protection Remplacement de la lampe Respecer les intervalles de remplacement selon L indication du fabricant d
Download Pdf Manuals
Related Search
Related Contents
notice - Summilux.net Neutron Engineering Inc. - Fu Da Tong Technology Co., Ltd. 取扱説明書 Kullanma Klavuzu Quickstart Fiche emploi - La Littorale 25.02.2015 Citycable passe au tout numérique le 16 mars Samsung SCX-4521F manual do usuário Compteurs d`énergie mono- et triphasés et de l`indicateur de Bedienungsanleitung Brinsea Mini Eco Copyright © All rights reserved.