1. l LUG Gas Outlet pp u MAXITROL Page 2 of 8 Thank you for purchasing the PLUGI Gas Outlet The PLUG gas outlet makes it easy to move store or switch outdoor appliances Insert the gas plug fully into the new PLUGI gas outlet Push the switch to the ON position The appliance is now connected to the gas supply What To Do If You Smell Gas Do not try to light any appliance Do not touch any electric switch do not use any phone in the area Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department y a A MAXITROL General Notes Do not subject PLUGI gas outlet to open fire or excessive heat PLUGI is designed to operate at a max ambient temperature of 200 F 93 C Do not expose PLUGI to solvents oil dirt grease or other chemical agents Do not paint PLUGI cover plate or any of its components The cover plate may be cleaned with a damp cloth and a mild dish washing liquid Do not subject PLUG1 to mechanical stress Proper usage requires no excessive force m For performance reasons it is highly recommended that the gas plug supplied be used with the PLUG gas outlet If these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or death No attempt shall be made to convert the gas appliance from the gas specified on
2. ch to the ON position ON will be visible on top of switch The appliance is now connected to the gas supply Disconnecting a gas appliance from the PLUGI Gas Outlet Step 1 1 Push switch to the OFF position 2 Pull gas plug straight out of socket The appliance is now disconnected from the gas supply OFF position Maxitrol Company is a recipient of the Home Safety Council s Commendation Award for Product Innovation for Consumer Safety for it s Plugl gas outlet Use of the Commendation Seal next to the product indicated that the Council has evaluated the Plugl gas outlet based upon information furnished by the manufacturer and believes the product demonstrated an innovative use of safety features The Council does not test or endorse any products PLUG1 UG EN 06 2006 www plug1 com Made in Germany MAXITROL 2006 Maxitrol Company All Rights Reserved y
3. es and LP gas air mixtures Integrated excess flow valve Manual ON OFF gas switch function Pipe material CSST semi rigid copper tubing black iron pipe Mounting position The PLUG1 can be mounted in any position on a vertical surface CSA certified Integrated high temperature activated shut off device activates before temperature reaches 300 F 149 C Ambient temperature range 20 F to 200 F 29 C to 93 C Maximum pressure rating 5 psi 345 mbar Gas supply inlet connection 1 2 NPT Gas outlet connection 3 8 NPT Maximum nominal capacity of appliance 70 000 BTU hr 20 5 kW Gas plug cannot be disconnected from PLUG1 when switch is in the ON position Limited Warranty Disclaimers Exclusive Remedy and Limitation On Liability Maxitrol war rants that its product is manufactured free from defects in materials and workmanship under normal use and specifications and will operate as such for a period of one 1 year from the date of manufacture This limited warranty extends only to the original purchaser Damage and or injury due to or resulting from its shipment and or use not in accordance with specifications including but not limited to faulty installation ad justments exposure to excessive pressure temperature debris moisture and or corrosive chemicals improper application misuse or abuse non specified product or part modification or the negligence of others are not covered by the warranty and a
4. re not the responsibility of Maxitrol There are no other warranties expressed or implied y a A MAXITROL Integrated Excess Flow Valve Excess Flow Valve in normal OPEN position Shaded area represents gas flow Figure A Excess Flow Valve in CLOSED position Lea Gas supply is shut off Shaded area represents gas flow NOTE Excess Flow Valve auto matically reopens after repair has been made and gas plug is reinserted into Plug1 gas outlet DY AV ER VA WA A Figure B y N MAXITROL Components Manual ON OFF gas switch Socket behind Slider Plate Circular Opening in Slider Plate Gas Plug hose not included Snap On Cover Plate Pp _ MAXITROL Page 7 of 8 Connecting a gas appliance to the PLUGI Gas Outlet NOTE Without the gas plug inserted into the outlet no gas will flow regardless of the position of the ON OFF switch With the switch in the ON position it is not possible to connect the gas plug Step 1 The ON OFF gas switch must be in the OFF position to insert the gas plug ON label on switch will not be visible Step 2 Insert gas plug into the slider s circular opening Step 3 Move the slider plate upwards Step 4 Push the gas plug fully into the socket opening MAXITROL Page 8 of 8 Step 5 To turn on gas push the swit
5. the rating plate for use with a different gas without consulting the installation instruction the serving gas supplier or the equipment manufacturer for complete instructions Installation Requirements Installation of the PLUG gas outlet must be performed by a qualified installer or the gas supplier There are no serviceable parts inside Do NOT open PLUGI shall be installed in accordance with local codes or in the absence of local codes the National Fuel Gas Code ANSI Z223 1 NFPA 54 National Gas and Propane Installation Code CSA B149 1 as is applicable and operated in accordance with manufacturer s instructions Installation inspection and replacement must be performed by a qualified installer or the gas supplier The gas plug must be connected to an approved flexible appliance connector according to ANSI Z21 54 CSA 8 4 outdoors or Z21 69 CSA 6 16 Z21 24 CSA 6 10 indoors Suitable for use with natural manufactured mixed and propane LP gases and LP gas air mixtures a a A MAXITROL PLUG Product Features The PLUGI is a gas outlet and much more The PLUGI has an integrated excess flow valve that shuts off the gas flow when a predefined flow rate occurs figures A amp B In addition an integrated high temperature acti vated shut off device shuts off the gas flow when a predefined tempera ture occurs For indoor or outdoor use Suitable for use with natural manufactured mixed and propane LP gas
Download Pdf Manuals
Related Search
Related Contents
LOEWE Xelos 37 SL DR+ SGH 50 - Middleby Manuel d`utilisation Transcend 128MB SDRAM PC133 ECC Registered Memory Honeywell RTH7500D Instructions / Assembly Philips Sonicare Replacement brush head variety pack HX6005 Motorola Semiconductor Engineering Bulletin Hampton Bay DYX1691A Instructions / Assembly 高調波電流抑制対策 実施要領 - JEITA 一般社団法人電子情報技術 Logicube Omniclone Xi User's Manual Copyright © All rights reserved.