1. pairs 4 5 and 7 8 or All Span pairs 1 2 4 5 and 3 6 7 8 The type of power is displayed as PoE Standard complies with IEEE 802 3af Cisco Cisco pre standard power or Non Standard The voltage and polarity of the powered wire pairs are also displayed NOTE If power is detected on additional wire pairs a double headed arrow will appear next to Pair Pressing the UP DOWN cursor key will scroll through the additional wire pairs The voltage measurements are continuously updated in the POWER screen Pressing the INFO function key presents the POWER INFO Screen and starts a loaded power test The No Load and Load voltages are displayed The load test for a PoE Standard Link is about 10 Watts and the load test for a Cisco Pre Standard Link is about 5 Watts The loaded power test is not available for Non Standard power types or when less than 40 Volts is measured for PoE Standard and Cisco Pre Standard Links A voltage difference of about 0 5 to 1 0 Volts is typical for short cables 1 to 25 feet and 2 0 to 3 0 Volts is typical for long cables 200 to 300 feet Larger voltage drops indicate a problem in the cabling system or an under powered port Link Resistance is shown and is typically 0 5 Ohms for the port plus 2 0 to 2 5 Ohms per 100 feet of cable Higher resistance values indicate a problem with the cabling system Pressing the UP DOWN cursor key will scroll through any additional wire pairs t
2. ee SETUP Pressing the SETUP function key in any screen presents the Setup Screen The Up Down cursor key is used to display 1 Power Down Time Setup 2 Detection Level Setup 3 Units Setup and 4 Link Search Time Setup Press the SELECT function key to enter the displayed setup screen POWER DOWN SETUP The LanMaster 35 will automatically turn off after the time selected in the Power Down Setup screen Settings available are five minutes fifteen minutes thirty minutes and on must be turned off manually Press the SAVE function key to store the selected setting POWER DOWH TIME 5 MIH Exit Save DETECTION LEVEL SETUP The minimum voltage Detection level for the Power Test for PoE Standard and Cisco Pre Standard power is fixed at 40 Volts The minimum voltage Detection level for the Power Test for Non Standard power can be set from 12 5 Volts to 24 Volts the default is 18 Volts This allows the user to test for other types of power that may be on a connection such as some types of PBXs Pressing the Up Down cursor key changes the level in 0 5V increments Press the SAVE function key to store the selected setting UNITS SETUP The Units Setup Screen is used to select the units used when displaying the length measurement in the Length screen The Up Down cursor key is used to select Feet or Meters Press the Save function key to store the selected units Setup DETECTION LEVEL Tig 5 DC Exit Save Set
3. Io aa aee ON OFF BUTTON Nani CABLETRACKER 15 TONE PROBE OPTIONAL OVERVIEW The CableTracker Model 15 Probe identifies cables and terminations by detecting a trace tone signal transmitted by the LanMaster 35 When the Probe is near the correct cable pair or punchdown it indicates detection by emitting an audible signal with the same pattern that is selected on the LanMaster 35 SIGNAL SENOR m POWER ONH INDICATOR a j j TRAER Peace H ara POWER BUTTON A y ad patar iis ye AKER CABLE TRACING Connect the LanMaster 35 to the RJ 45 on a cable Turn on the Model 15 Probe by pressing and holding the button Place the probe tip near the cable or termination to be identified and the Probe will emit an audible signal The audible signal is loudest when the Probe is near the correct cable or termination point The volume can be adjusted by rotating the thumbwheel located above the button The Power ON indicator is illuminated when the unit is on and the battery has adequate voltage BATTERY The CableTracker Model 15 Probe operates on one 9 volt alkaline battery Remove the battery cover at the back of the unit connect the battery to the battery snap cable insert the battery in the battery well and replace the battery cover BATTERY LIFE The Model 15 Probe will operate for approximately 16 hours on one 9 volt alkaline battery When the battery i
4. WARRANTY Psiber Data Systems Inc warrants that the product shall be free from defects in parts or workmanship for a period of 12 months from the date of purchase if used in accordance with Psiber Data Systems Inc operating specifications THIS IS THE ONLY WARRANTY MADE BY Psiber Data Systems Inc AND IS EXPRESSLY MADE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE Should any parts or workmanship prove defective Psiber Data Systems Inc will repair or replace at Psiber Data Systems option at no cost to the Buyer except for shipping costs from the Buyer s location to Psiber Data Systems Inc This is Buyer s SOLE AND EXCLUSIVE REMEDY under this Agreement This warranty does not apply to products which have been subject to neglect accident or improper use or to units which have been altered or repaired by other than an authorized repair facility Return of Equipment To return a product to Psiber Data Systems Inc first obtain a Return Authorization number from our Customer Service by calling 619 287 9970 The RA must be clearly marked on the shipping label or the package will not be accepted by Psiber Data Systems Inc See sample label below To Psiber Data Sytems Inc 7075 K Mission Gorge Road San Diego CA 92120 RA XXXXXXXX LanMaster psiber and the Psiber logo are trademarks of Psiber Data Systems Inc Copyright 2006 P
5. hat have voltage and display Link Resistance for each pair Pressing the INFO function key returns to the POWER Screen POWER EMO SPAH Type PoE STANDARD 45 Al Setup Pairi 12 36 Exit Info POWER IMFO 12 3664 HoLoad 46 80 Load 47 5 Resistance 3 6 Ohms Exit Info Setup LINK TEST Pressing the LINK function key in the START screen begins a scan of the RJ 45 connection for Link signals If no Link signals are found a No Link Found message is displayed and EXIT and LENGTH function keys are provided When Link signals are detected the LanMaster 35 displays the connection as a LAN NIC or an Auto MDI X port the speed and duplex capabilites of the Link Partner When acu the Link is established the EXIT SETUP and PORT ID function keys are displayed Note If a Link Partner is not set to Auto negotiate the duplex mode is unknown shown as UN in the LINK screen This is due to the type of Link signals used in fixed modes PORT ID Pressing the PORT ID function key in the Link Screen presents the Port ID Screen As soon as this screen appears the LanMaster 35 begins transmitting a pattern of Link signals that will cause the hub Switch or NIC Link LED to blink or stay on continuously This will identify the specific port a all outlet or PC is connected Hubs and switches from various manufacturers have different specifications for the time it takes for Link signals to turn the Link LED on and off T
6. he LanMaster 35 has four different blink rates and a continuous mode that can be selected by pressing the Up Down cursor key An initial test directly at the hub or switch will determine the best blink rate setting before conducting a Port ID test at a wall outlet LENGTH The LENGTH function is only available when the LINK Test shows a No Link Found condition Pressing the LENGTH function key presents the LENGTH Screen Length is measured on pairs 1 2 and 3 6 with a minimum length of 6 feet 2 meters and a maximum length of 330 feet 100 meters The lengths of the two cable pairs may be slightly different depending on how the pairs are twisted together in the cable The length measurement is to the nearest open or short in the cable run Typically this is an open at the end of the cable disconnected RJ 45 or unterminated cable The LENGTH function should be used to identify cable faults and provide the approximate location The TONE function can then be used with the CableTracker 15 Tone Probe to pinpoint the fault location TONE Pressing the TONE function key in the START Screen presents the Tone Screen and the LanMaster 35 begins transmitting one of four tone patterns Pressing the Up Down cursor key changes the tone pattern LINK FOUND Port RUTO Link Her ISGHer Let Exit PortIO Setup PORT IO Rate MET LM Select LEHGTH Pair 1 2 108FT OFEH Pair 3 6 118FT OPEH Exit Setup TOHE T Pattern 1 Exit
7. s below the level required for the Model 15 to operate properly the Power ON indicator will not illuminate 6 BATTERY LIFE Duration The LanMaster 35 will typically provide about 5 to 6 hours of operation from a set of four AA alkaline batteries Auto Power Down The Lanmaster 35 will automatically turn off after the time selected in the Power Down Setup screen or will run continuously until manually turned off when ON is selected for Power Down Low Battery When the batteries are below the level required for the LanMaster 35 to operate properly a battery graphic appears in the upper right hand corner of the display SAFETY Disconnect any connections to the LanMaster 35 RJ 45 before opening the battery cover OPERATION To test a hub switch router or NIC connect a patch cable from the RJ 45 port on the equipment patch panel or wall outlet to the RJ 45 jack on the LanMaster 35 START SCREEN Turn on the LanMaster 35 by pressing the PWR button The unit displays an information screen and then the START screen for selecting a test POWER TEST Pressing the POWER function key begins a voltage scan of all wire pairs on the RJ 45 connection If no voltage s is found a No Power message is displayed and an EXIT function is provided to return to the START Screen When voltage s is detected the POWER display is presented The power configuration is shown as End Span pairs 1 2 and 3 6 Mid Span
8. siber Data Systems Inc All rights reserved P N 1005 0350 0001 Rev A Fa LANMASTER 35 POWER AND LINK TESTER USER GUIDE psiber BOX CONTENTS e LanMaster 35 Power and Link Tester Carrying Case User Guide e Four AA Alkaline Batteries CableTracker 15 Tone Tracing Probe Optional BATTERY The LanMaster 35 operates on four AA alkaline batteries Remove the battery cover at the back of the unit and insert the batteries with the orientation as shown Battery polarity is marked inside the battery well for reference TECHNICAL OVERVIEW The LanMaster 35 Power and Link Tester provides seven different test capabilities 1 tests network connections for IEEE 802 3af Cisco pre standard and non standard types of power 2 conducts a power test with an actual load to verify the amount of power available 3 measures Link Resistance 4 identifies speed and duplex modes for 10 100 1000baseTX Ethernet Links 5 provides a Port Identification function with selectable blink rates to locate which port on a hub or switch that a wall outlet is connected 6 measures the cable length only when the cable is not connected to active equipment 7 transmits a tone signal that allows the cable to be traced or a punchdown identified with the CableTracker 15 Tone Probe MECHANICAL FEATURES RJ 45 CONNECTION PO RT ONY EN Saye es a CURSOR KEYS NS f LEFT UP DOWN RIGHT Nie a
9. up UNITS SETUP Feet Meters Exit Save LINK SEARCH SETUP The Link Search setup screen is used to set the length of time that the LanMaster 35 will monitor a wire pair for Link signals The available settings are Normal default setting of about 2 5 seconds and Long about 5 seconds Use the Up Down cursor key to select the setting Some switches especially if configured for VoIP require a longer time to complete Link negotiations and the Long setting will provide more consistent Link detection Setup LINK SEARCH E Hormal Long Exit Save Setup
Download Pdf Manuals
Related Search
Related Contents
National Instruments cFP-21xx Switch User Manual Tennis Court Booking User Guide 2014.15-3 Magnavox 27MS343S CRT Television User Manual Samsung DVD-P183 User Manual Mode d`emploi Téléphone sans cordon à 25 voies avec SecureVoice Guide de l SIMULATIONS USING PSPICE & OSCILLOSCOPE TRAINING DRILL Copyright © All rights reserved.