1. Srey al Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de 3 Manual Shut down Pressing this button MENU 5 for longer switches the instrument off 4 Auto Shut down The instrument switches off automatically after three minutes of inactivity Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de 3 Button functions 3 1 N OK 1 4 11 i5 10 6 9 8 T 1 Area Volume Pythagoras 2 Plus Go Up 3 Tilt triangle 4 Confirmation 5 Go Right 6 Saving Historical data 7 Power On Measuring On Single continuous meas 8 Menu Power Off 9 Minus Go Down 10 Reference 11 Go Left 12 Clear Cancel Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de 4 Display screen general view Status Bar 69 08 55 Program selecttion A 56 189M 56580m av O J IM Measurement field Measurement type Result Bar The graphics screen of the measurement window is split into different areas Top second screen is the measurement functional field which contains the currently selected measuring program Just to the left right appears the program submenu which shows the measuring programs that can be selected by pressing the same key the required numbe
2. below 10 1 Tools 1 Timer In screen of Tools Timer Tools gt Timer 0 000s Select The unit of delay time is second press or move the cursor to select the digit of data and press Lo to increase or reduce the value press OK to save and return irn to upper interface or press M cancel the modification and return to the previous data Press N to call up the function the remaining seconds until measurement e g 10 9 8 are displayed in a countdown The last 5 seconds are counted down with a beep After the last beep the measurement is taken and the value is displayed 2 Staking Out Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de In screen of Tools Staking out Tools Staking 0 000mM Up or Down press Or gt move the cursor to select the digit of data and press Lo L to increase or reduce the value press OK to save and return to upper interface or press Ls M cancel the modification and return to the previous data Pressing the button N starts the laser measurement The display shows required stake out distance in the summary line between the stake out point and the instrument rear reference If the instrument moved slowly along the stake out line the displayed distance decreases The instrument starts to beep at a distance of 0 1m from the next stake out point The arrows in
3. start 3 Press OK button to triggle export function tile finis 1 Establish Connection between meter and terminals through data cable 2 Open editors like EXCEL and move the cursor where you want to start 3 Press OK button to activate export function till finished L I Only U series have such function A series haven t such application i Using this function not need to install specified software Excel file is applicable 10 2 Personal Set 1 Offset Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de In screen of Personal setting gt Offset press lt or gt move the cursor to select the digit of data and press Lo to increase or reduce the value press OK to save and return to previous interface or inna press I cancel the modification and return to the previous data An offset adds or subtracts a specified value automatically to or from all measurements 2 Brightness In screen of Personal setting gt Brightness The brightness of screen could be adjusted in 5 levels by pressing Lor V to be lighter or darker 3 Time Format In screen of Personal setting gt time format Three kinds of time format could be selected by pressing m V l ninm press OK to save and return to upper interface or press M cancel the modification and return to the previous data 4 G Sensor In screen of Per
4. symbol appears in the function field on the display as following to take No 1 and No 2 length the result is displayed on the ihn summary line Press M to delete any measured length and then press A to re measure 6 Double Pythagoras Press four times to activate the function the symbol display in function field as following to take No 1 2 and 3 length Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de the height is displayed on the summary line Press t to find additoinal information 6 Tilt measurement 1 Tilt measurement Press 4 button the symbol appears in the function field press A to take the inclination and the distance UJ The inclination sensor measures tilts between 45 a IEF During the measurement of tilt the instrument should be held without transverse tilt as far as possible within 10 The accuracy is 0 3 2 Auto horizontal measurement Press A twice the symbol appears in the functional field Press A button to measure angel and distance The summary line displays the result as the direct horizontal distance 3 Auto height measurement Press third times the symbol appears in the functional field Press N button to take both sloping sides the vertical height is displayed in the summary line 4 Triangular measurement Press 4 four times the symbol E appears
5. type locked unlocked no of order all data date time measurement function measurement types corresponding result additional information For example in function of volume measuemnt additional infomration such as ceiling floor area surface area of the walls circumference displays 3 Historical record delete Batch records delete siam When cursor select one of measurement type Press M then press OK to delete all the historical records belonging to this measurement type Single record delete mme press aor to browse the record then Press M ana press OK to delete the record Press dor V to browse the record then repeatedly press OK to loock and unlock the Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de record 10 System settings Menu gt Tools Menu gt Set Menu gt Personal Set ET E Menu gt Others 4 gt gt lt gt lt Level M Bubble kn LE Bright un e Reset O Timer Time Set Offset re o Factory Reset Staking Beep on Time Format About Us ES Y Temperature T Measure Unit o G Sensor EJ Fey Export p Angle Unit Language oo Press MENU 5 enter main screen press for V to move up and down find out setting type press to be next sub setting function Five kinds of funcitons proivded Tools Personal Set Set others which will be addressed
6. 59410 Fax 089 66559430 office cosinus de 11 Error Code Code Cause Corrective Measure Transverse tilt greater than Hold the instrument without any transverse tilt 10 O Main tilt direction angle too Measure angle up to max 45 high gt 45 accomplished on a leveled leveled surface surface 2 04 The calibration has not been Calibrate the device on an absolute Horizontal 252 Temperature too High 253 Temperature too Low 255 Receiver signal too weak Use target plate or change a good refection measurement time too long 256 Received signal too strong Target too reflective use target plate or do not aim at strong light objective Error Hardware error and owitch on off the device several times If the uncertainty error symbol still appears then your instrument is defective Please call your dealer for assistance Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de 12 Measurement steps Measurement steps Additional Function Information Red side measuring Green side result Area Volume Pyth agorean1 Pyth agorean2 Inclination measurement Auto Horizontal Auto Heights Triangular otaking out Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de 13 Technical specifi
7. Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de MileSeey S3 series handheld laser distance meter user guide 1 Overview MileSeey S3 series product measures up to 100m integrates tilt sensor and full color screen is specially for professional users Initial adoption of li ion battery which greatly enhances usage life and can last for several years In addition it is more green mOS V1 0 is an innovated and patent measuring system which has vivid colorful screen strong interactive interface and has M professional measuring functions The various supplement t OK functions and unique personal setting providing unexpected iN gt measuring experience and fun y EN The perfect combination of ergonomic design and fashion provides MENU b amazing functions and experience The product leads to a new era of professional measurement 2 Start up amp Shut down 1 Inserting replacing batteries Remove battery compartment lid by pressing it lightly insert the provided Li ion battery and close the cover Sl IEF Remove the batteries before any long period of non use to avoid the danger of corrosion a 7 Your strongly recommended to user li ion batteries which is produced by original laser meter producer 2 Start up Press N key to start up and directly go to the interface of single measuring see figure 69 20 55
8. cations Functional Spec S3A S3U Measuring units M in ft M in ft Laser Class Class 2M Class 2M Display 2 Inch Full color screen 2 Inch Full color screen Tilt measurements YES YES zer Angle measurement using tilt YES YES sensor 45 Staking out function LL RE LL ER Recall last values m 1000 Buzzer indication mew 0 Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de 14 Package Porch Li ion battery Power Charger A Data Cable 15 Contact ShenZhen MileSeey Technology Co Ltd ADD F 6 Building 9 Zhongguan Honghualing Industrial South Park 11 1213 Liuxian Ave Taoyuan Street Nanshan District Shenzhen 518055 P R China TEL 86 755 86329055 FAX 86 55 86 01592 Website www mileseey net
9. g gt Beep Press iso i to select ON or OFF the beep press OK to save and return to upper nama interface or press M cancel the modification and return to the previous data 4 Time Set In screen of Setting gt Time set press lt or gt move the cursor to select the digit of data and press Lor i to increase or reduce the value press OK to save and return to upper interface or press min M cancel the modification and return the previous data 5 Bubble In screen of Setting gt Bubble Press lor V to select ON or OFF the bubble which is display in the status filed in the niin screen press OK to save and return to upper interface or press M cancel the Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de modification and return to the previous data 10 4 Others 1 About us In screen of Setting gt Others About us Software information display Version Copyright en Press OKor Ill to go back to upper interface 2 Factory Reset In screen of Setting gt Others Factory Reset Press OK the device returns to the factory settings and stack and memory are deleted 3 Reset In screen of Setting gt Others Reset Press OK the device returns to the factory settings but the records are still in the memory Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 665
10. he previous one press OK to save niim and return to measurment interface or press M cancel the modification and return the previous data 8 Data locking 1 Data locking introduction Usually the instrument keeps and deletes the measurement data in sequence of first in first out The first in value will be deleted if total measurement data reach the maximum storage eg 30 records This function enable user to save data permanently except user deletes it manually from memory 2 Lock data in mode of measuring when measuring select data press a the dialog box pop up user to select save button then press OK to lock the data return to measurement interface 3 Lock unlock data in Historical record function In history data interface move cursor to navigate the data then OK to lock it And press OK again to unlock the data 9 Historical record 1 Historical record view Press A to call up the function press t Or to select the measurment type sorting by which all of the data record displays in sequnce of created time Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de All 1000 1000 ALL 18 30 18 20 15 23 P 14 50 lt 9 36 Pea B 28 aE 71 59 Q 2 View detail record 14 35 EZ 2012 02 02 13 20 54 4618M 5 5660 M 4 561 m Press to read detail informaton of this record including data
11. in the functional area Press A button to take 3 sloping sides respectively the area is displayed in the summary line Press t to find out each angel of the Triangular and circumference 7 Edit Measuring data Function Note this function is only enabled in measurement mode and at least a measured data display in the screen 1 Select data Press Lo to select measuring type in measuring process file left handside of the screen press gt to locate the corresponding data the data frame turning yellow indicates the data has been selected 2 Re measure When this data was selected press N to re measure the distance till the result is satisfied Press OK or D return to measurement interface 3 Adjust measurement result Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de When this data was selected press the cursor appears in the measurement type field press or move the cursor to select the digit of data and press Lor to increase or reduce the value press OK to save and return to measurment interface or an press M cancel the modification and return the previous data 4 Addition subtraction When this data was selected press t to appears in the measuremnt type field press N the next measurement is added to the previous In the same approach Press the The next measurement is subtracted from t
12. ion enable user to measure the minimum or maximum distance from a fixed Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de ofan measuring point User can press A or M to stop the function and The values for maximum and minimum distances are shown in the display as well as the last measured value in the summary line 3 Area Measuring 6 189M 4 589M 21 556M Press once the symbol CS appears in function filed of display Press N to take the first distance measurement e g Length Press A again to take the second distance measurement e g width The results of length width perimeter and area are displayed in the historical data line in order 4 Volume Measuring Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de 69 20 55 i U 6 189M 4 589M 4 556M Press tem twice the symbol appears in the function field on the display and the volume function activated as well Press N to take the first length measurement e g Length Next get the width then heights the final result is displayed in the summary line Press t and to display additional room information such as ceiling floor surface area of the walls circumference 5 Single Pythagoras Press three times to activate the function
13. r of times The measurement field contains the individual measurements of the measuring program with reference to a series of separate distance measurements Three lines are provided for last measurement data A horizontal line separates the measurement field and the result bar from one another 1 Status bar with time battery status bubble 2 Program selection with measurement instructions 3 Status of measurement Reference laser on 3 Measurement field 4 Result bar o Measurement type Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de 5 Measuring IEF in measuring mode user can press M to delete the current measured data and re measure 1 Single Measuring Following 3 entries lead to single measurement function see figure 69 20 55 p AL 96 189M 56 589M 16 079M Press A key to start up and directly go to the interface of single measuring gt It will be back to this mode after completing measurement every time User will be back to single measuring mode by press MENU 5 one or more times in menu setting interface Press N to activate the laser Press N again to trigger the distance measurement The result is displayed immediately 2 Continuous Measuring bei 1 56 189M 96 589M Press and hold down A the key until hear beep to activate continuous measurement This funct
14. sonal setting gt G Sensor You can calibrate the tilt sensor in the device Calibration requires two measurements on a level surface Put on the device on the level surface press OK Rotate the device horizontally through 180 press OK The tilt sensor is calibrated Personal Set gt G sensor EI B Personal Set gt G sensor Eh B Personal Set gt G sensor On A Level Surface Rotate the device G Sensor Finish Ga OK B horizontally 180 5 Language Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de In screen of Personal setting gt Language Press Lor to select the language press OK to save and return to upper interface ofan or press M cancel the modification and return to the previous language English is default language 10 3 Set 1 Measurement Unit In screen of Setting gt Measurement unit 4 type of units can be selected as Meter Feet Inch Feet amp lnch Press tod to select the unit press OK to save and return to upper interface or ofan press I cancel the modification and return to the previous data 2 Angle Unit In screen of Setting gt Angle Unit Two kinds of angel unit available 0 0 or 0 00 Press trot to select the unit press OK to save and return to upper interface or arsine press M cancel the modification and return to the previous data 3 Beep In screen of Settin
15. the display indicate in which direction the Meter needs to be moved in order to achieve the defined distance As soon as the staking out point is reached the symbol appears in the display 3 Level In screen of Tools Level Tools gt Level 95 3 mercury columns represents X y and 45 axis the value display when meter is rotated 4 Thermometer Cosinus Messtechnik GmbH Lise Meitner Stra e 6 85521 Ottobrunn www cosinus de Tel 089 66559410 Fax 089 66559430 office cosinus de Tools gt Temperature 122 fi 104 86 68 50 P fmm 14 A i E e i MW e In screen of Tools gt thermometer The thermometer records the current temperature of meter in the environment Both Fahrenheit and degree Celsius are displayed in the screen 5 Export In screen of Tools gt Export gt Real time Export in the Connection between meter and terminals through data cable when user press N to take single measurement date the data is automatically transmited to terminals without installing any additional software Battch Export Tools Export E Tools Export cH Tools Export EB Tools gt Exp c mmy Export Export Data exporting Export Export Connection established Data export successfully 1 Connect your terminals to press OK to continue please hold on your meter throught data cable 2 Open editors like EXCEL and move the curse whers you want om to