1. Gruetzner LUBRICUS m User Guide Lubricus Lubrication System LUB D1 LUB De LUB DS LUB D4 24 VDC version 04 2013 LUBRICUS Content General Information Warning scope of Supply Overview General safety details Intended use Extent of warranty General safety information Transport and storage Function Principle Communication Interface Connector PIN assignment Installation instruction Pulse signals details Functional problems error message and problems Service replacement of cartridge Technical Data Recommended tube length Mounting Disposal WwW WW O amp O ARS 11 11 12 12 Gruetzner GmbH version 04 2013 Gruetzner LUBRICUS m General Information Thank you very much deciding to use Lubricus Lubrication System Make sure that you familiarize yourself with the safety instructions of Lubricus Lubrication System and the accessories supplied with this unit This manual contains important safety information The Lubricus Lubrication System is a very compact lubrication pump for oil and grease up to NLGI 2 The pump requires 24 VDC power supply The lubricant reservoir 400 cm is contained in cartridge Supply pressure is up to 70 bar 1 000 psi The Lubricus Lubrication System Type D is available with up to 4 outlets Warning Lubricus Lubrication System is designed for use in normal industrial environment indoor as well as outdoor but is not suitable for mounting on moving
2. IMPORTANT Please pay attention not only to the safety instructions under this main point but also to those special security cautions that are mentioned on the other pages This symbol warns of electrical voltage This symbol warns of electrical voltage 4 version 04 2013 Gunnell LUBRICUS ant This heading is used if inaccurate compliance or non compliance with the operating Instructions or Attention specified work procedures etc may result in damage Points out special information Notes attached directly on the machine must be strictly followed and maintained in completely readable condition Qualification and training of the personnel The operation maintenance service and installation personnel must have appropriate qualifications for this work Responsibility and supervision of the personnel must be clearly defined by the end user operator If the personnel do not have the necessary knowledge they must be trained and instructed The operator must ensure that the personnel have completely understood the contents of the user information Non observance of the safety information can be dangerous Not observing the safety information can lead to danger for people environment and machines Not observing the safety information can mean the loss of any or all damage claims In special cases non observance can for example lead to the following dangers Failure of important plant functions Fa
3. Gruetzner LUBRICUS m Function Principle When you activate Lubricus Type D the piston pump starts to work and pump the lubricant in small quantities to the outlets The integrated microprocessor controls the function Communication with the machine controller is necessary Delivery rates and time between the lubrication intervals can be individually set by pulse signals The Lubricus Lubrication System uses a four pin socket to connect a M12X1 plug allowing communication with the machine controller An external 24 VDC power supply is used to switch ON and OFF voltage of 20 up to 30 VDC supplied to PIN 1 When voltage is supplied the lubrication pump is in operating condition If there are no errors Pump OK the input voltage will be transferred to the output signal PIN 4 indicating all is OK Once the voltage supply to PIN 1 is stopped switched OFF the pump rests and saves the current operating conditions in memory When the pump is turned back on the saved operating conditions will be continued PIN 4 relays the operating condition Connector PIN assignment connection to Lubicus Type D Connector PIN assignment M 12 x 1 PIN 1 input voltage 20 30 VDC color brown PIN 2 activation of the individual pump outlets color white PIN 3 Ground GND color blue PIN 4 Output Signal color black Details Peak current Imax during pump operation approx 350 mA typically lt 200 mA Standby current standby mode lt 20 m
4. equipment for example trucks Only use original Lubricus cartridge and original spare parts None original spare parts can destroy the Lubricus Lubrication System Scope of supply Standard delivery includes Lubricus Lubrication System Tube connector attaches to the outlet suitable for flexible tube 6 x 4 6mm outside and 4mm inside diameter Operating Instructions Overview The setup of your Lubricus Lubrication System is easy This user manual will learn you the basic operation and adjustments Ventilation Lock Pa Housing lt lt Connection M12x1 external control Important remark unused outlets must remain open to avoid damage to the pump 3 version 04 2013 LUBRICUS Gr vetzner n General safety details Everybody who is involved with the installation start up maintenance and operation of the Lubricus Lubrication System must read these instructions carefully Use in accordance with guide Lubricus Lubrication System is only allowed for industrial use Lubricus Lubrication System may only be put into service if it is integrated or attached to another Attention machine and will be operated together with that machine Lubricus Lubrication System may only be used according to the technical data see chapter technical data Unauthorized structural changes at the Lubricus Lubrication System are not permitted We do not assume liability for damages of persons or machines which result from tha
5. water Operation up to 1 m Combination with progressive systems possible Recommened tube length Keep in mind For low temperature For stiff grease more than NLGI 2 For difficult applications with high backpressure gt Shorten your tube as much as possible gt Minimum inner diameter is 4mm Q gt Avoid reductions of the inner tube 70 oo 60 SS low temperature 50 t stiff grease 40 a S S E backpressure n aT 10 bar Pressure bar Length m Chart Required pressure vs tube length tested with tubes 6 x 4 mm 11 version 04 2013 Gruetzner LUBRICUS m Mounting FlexxPump 2 srews 6mm for example M6x40 are required for a safe installation of your FlexxPump The optimum tightening torque of the screw is 5 Nm 3 points at the back assure a safe support a A an nen DAT a8 a ass Auflagqeflachen fasterinq support Disposal When disposing lubricant the waste disposal instructions of the lubricant manufacturer must be observed Disposal of Lubricus Lubrication System observe the regional valid laws and regulations The empty lubricant cartridges contain lubricant remains Please dispose with other oil contaminated garbage Gruetzner GmbH Kohlenhofstr 60 D 90443 Nurnberg www lubricus com Tel 49 911 277 399 0 Fax 49 911 277 399 99 version 04 2013
6. A Output signal PIN 4 High 20 30 VDC OK Low 0 V Error empty signal over current The outlet signal PIN4 can be charged with maximal 300mA Warning the exit is not short circuit proof A time delay fuse 1A is normally required Output signal in case of empty lubricant reservoir PIN 4 generates an alternating high and low signal switching with 0 5 Hz Pump function control after receiving a correct pulse signal at PIN 2 the pump starts to work During the function of the pump about 7s the output signal at PIN 4 is switching from High 20 30 VDC to Low 0 V By counting the signals of the pump function control there is a possibility to estimate the delivered quantity of lubricant and the remaining quantity in the lubricant reservoir delivery rate per pulse signal 0 15 cm 7 version 04 2013 Gruetzner LUBRICUS mt Installation and commissioning Identification of the pump outlets 11 12 1 3 1 4 Pulse signal details Indication in seconds accuracy 10 delivery rate per pulse signal 0 15 cm one outlet time between two pulse signals minimum 15 s aclivale 1 1 3s activate 1 1 1 2 3s 3s outlets will be served alternatty High and dispensed aqual quantities High from both outis minimal 15 5 Low aclivate 2 1 Highi gt 55 ooo Low aclivale 2 1 2 2 6s 6s High minimal 185 outiats will ba sarad altarnatly and dispensed equal quantitas from
7. both outlets High Low activate 1 1 1 2 2 1 22 outiats will ba sarwed altarnatly and dispensed aqual quantities Highi from all cutlets gt 55 Low 8 version 04 2013 4 Gruetzner e LUBEBRICUS om Functional problems Error messages faults The dedicated error message is given to PIN 4 E1 Empty lubricant reservoir PIN 4 generates an alternating high and low signal switching with 0 5 Hz Root cause lubricant cartridge is empty The pump will stop Corrective action replace cartridge Pump will continue to run as per active program E2 Back pressure too high over current Output Signal Low Root cause Back pressure was measured 3 x too high The lubrication point could be clogged the tube length could be too long or the grease is too stiff or has hardened The pump will stop Corrective action Trace reason for high back pressure gt Obar and correct it Switch unit OFF and On again The error message will be reset to 0 The pump will start again as per program in memory System error Switch unit OFF and On again Memory will not be erased Service replacement of cartridge Any further service is not necessary 1 Observe the safety instructions Switch off the pump Display report OFF 2 Take out ventilation locking turn clock wise to OPEN 3 Press the housing turn left and remove it 9 version 04 2013 t RICUS 4 Remove the empty cartr
8. idge 5 Remove protection from the new cartridge 6 Lubricate O Ring of the new cartridge slightly 7 Place the cartridge on the inlet 8 Place the pump upright on flat surface Reinstall the housin gently pressing while turning clockwise until hand tight 9 Install the ventilation lock and close it turn counter clockwise to CLOSE 10 Pump will work again according to settings error report will be deleted Gr uetznera GmbH version 04 2013 Gruetzner LUBRICUS m Technichal Data 196 Schlauchanschluk Schlauch 6 4 connection tube 6 4 abhangig von Schlauchanschlussteil Stecker M12x1 according to tube fittings connector WH2x4 Storage volume cartridge 400cm or max 500ml oilreservoir Lubricant oil or grease up to NLGI 2 Function principle piston pump Delivery rate per pulse signal 0 15 cm Number of outlets up to 4 Connection high pressure tube 6 x 4 flexible tube 6mm outside and 4mm inside Operating pressure max 70 bar Operating temperature 20 C to 70 C Operating voltage 24 VDC Dimensions max Width x height x depth 112 x 196 x 94 mm without tube fitting Weight without lubricant ca 1120g Integrated Control micro processor controlled Pressure monitoring integrated electronic monitoring backpressure Level monitoring integrated reedcontact Connector M12 x 1 4 pole for connection with PLC Protection class IP 65 suitable for under
9. ilure of prescribed methods of maintenance and preventive maintenance Endangering people due to electrical mechanical and chemical effects Endangering the environment due to leaks of dangerous materials Safety information for operators operating staff e Hot or cold machine parts are hazardous and must be protected from touching The protection on moving or rotating parts must not be removed e n case of leakages of dangerous media proper disposal not endangering environment and people must be ensured e Legal Regulation must be observed and complied Eliminate any danger due to electrical power Safety information for maintenance inspection and assembly work All maintenance inspection and installation work may only be carried out by trained specialists who have been informed appropriately by studying the user information closely All work must only be carried out when machine is shut down and while wearing appropriate protective clothing Always comply with the procedures for shutting the machine down that are described in the operating manual All the safety and protective equipment must be replaced immediately after completing work Environmentally hazardous substances that endanger the environment must be disposed in accordance with local regulations Secure the system during maintenance and repair work against intentional or unintentional operation Dispose of used lubricants in accordance with the safety data sheets of the lub
10. ort and storage Use suitable lifting gear for transport Do not throw or expose the Lubricus Lubrication System to strong shock loads Store the Lubricus Lubrication System in a cool and dry place to avoid corrosion of the system s individual parts Pay attention to the current safety and accident prevention instructions during the transport Wear suitable protection equipment if necessary Installation instruction The following conditions have to be satisfied during the installation of this Lubricus Lubrication System thus it can be assembled with other parts to a complete machine without affecting the safety and health of humans The housing of Lubricus should not be exposed to direct sunlight and or radiant heat preventing the formation of condensation Electrical connection Have the electric power supply connected only by a trained electrician e Connection and wiring of the electric components should be done by an expert trained in this field Te Check the voltage details with the existing power supply voltage Maintenance repair Disconnect the voltage feed before starting with maintenance or repair Maintenance and repair work may only be done with the system shut down Check the surface temperature of Lubricus Lubrication System due to danger of burning by radiant heat Always wear heat resistance gloves Protect the system from activation during maintenance and repair work 6 version 04 2013
11. ricant manufacturer Alterations and manufacture of spare parts without authority Rebuilding or altering the Lubricus Lubrication System is only allowed after consultation with the manufacturer Original spare parts and accessories authorized by the manufacturer are for safety purposes Using other parts results in loss of liability for claims resulting out of this For components retrofitted by the operator the manufacturer does not assume guarantee nor claims for damages 5 version 04 2013 LUBRICUS Gast n Prohibited methods of operation Operational security of the Lubricus Lubrication System is only guaranteed if it is operated in accordance with the operating instructions The limit values stated in the technical data must not be exceeded under any circumstances General risk reference All components of the system are designed in accordance with the prevailing regulations of the construction of technical machines in regards to operational safety and accident prevention Operation outside of these constraints can lead to dangers for the user respectively third persons or other technical facilities The Lubricus Lubrication System therefore may fulfil only in technically fault free condition its intended use This may only be carried out under compliance of the safety regulations and the attention of the operator s manual Therefore please regularly inspect the pump and its attachments for possible damage or leaks Transp
12. t Additional directives for use in accordance with the regulations e Pay attention to all notes in the operator s manual user guide Carry out all maintenance work e Follow all appropriate regulations for the work safety and accident prevention during life of the Lubricus Lubrication System Only qualified and authorized personnel can carry out required work on the Lubricus Lubrication System Attention Other uses or uses beyond those described above cannot be considered to be in accordance with the regulations Extent of warranty Warranties concerning operating safety reliability and capacity are only granted under the following conditions Assembly installation maintenance and repair are only carried out through trained specialist Hazardous hot or cold machine parts must be shielded to prevent touching The Lubricus Lubrication System must be used according to the instructions in the technical operating manual The rated technical data must not be exceeded in any case Retrofitting and repair work on the Lubricus Lubrication System may only be done by the manufacturer General safety information Basic information which must be followed during service operation and maintenance are listed as follows It is absolutely essential to read the operator s manual user guide by respective technical staff technical operator before installation and start up In addition to this it must be permanently available at the site