1. SS TS 75 User Guide for the users of the garage door operators TM 60 TS 75 TS 100 Please read this user guide before using your operator Please read carefully the security advises on the following pages Please fill in the serial number of your operator You will find the serial number on your operator Factory controlled by x y x The number describes the person who x made the final controls on this operator x x a English y Important Safety Instructions for the Users Please read these safety instructions carefully for your own safety and the safety of others Your Seip TS door operator is up to the latest safety standards and provides a high level of safety in use Following the instructions on this page will ensure a long term trouble free operation A garage door operator is not a toy do not allow children to play with it Keep the hand transmitter out of reach of children Only use the hand transmitter when you can see the gara ge door If the garage door cannot be seen you could acciden tally close the door whilst a car or person is passing by When stowing the hand transmitter please take care that it is not activated accidentally Be aware that the buttons could be hit inadvertently and always stow the hand transmitter with its buttons facing upwards Whilst entering the garage store the hand transmitter safely so that nobody can activate the operator intentio
2. old batteries in the hand transmitter if you should experience a problem with the range please change the batteries first The lower the batteries run the lower the range will be Building materials of the garage In a garage made of concrete and steel you might reach a lower range than in an ordinary garage build of stone The more steel was used for the walls the shorter the range of your remote con trol Remote control activity in the area Radio and television transmitters close to your garage might reduce the range Older baby phones Especially older baby phones might influence the range of the remote control severely These devices send strong signals via the houses internal power supply net These signals also intrude other devices via the wall plug as eg the operator It is extreemely unlikely that the range will drop to an unaccept able distance If however problems should occure we will like to be helpful Additional Information 2 channel MINI transmitter optional extra 433 MHz rolling code Two Batteries Two batteries type CR1616 or DL1616 are required Voltage 2 3V 6V Used batteries must be disposed of according to national laws TN HomeLink Use with a HomeLink System The HomeLink System is becoming more and more popular in private households Most frequently it is being used in cars the HomeLink module is integrated in the car It allows the driver to activate the door oper
3. With such a device contact between the garage door and any obstacle is usually avoided Programming the Hand Transmitters Basics As a standard the operator is equipped with a 433 MHz AM remote control set The coding is done via rolling code the code is changed after each impulse receiver and transmitter agree com pletely automatic about the next code to be used New codes will be chosen out of a pool of billions of possible codes Your operator is equipped with our standard remote control set when you hand transmitters looks like the one shown on the right hand side The 4 channel MIDI transmitter is standard equipment the 2 channel MINI transmitter is available as an optional If your operator is equipped with another remote control set please refer to the manufacturers instructions for programming Programming Transmitter and Receiver To use a hand transmitter it must first be registered programmed by the receiver Only one hand transmitter button can be used for one receiver Registering the first hand transmitter The first hand transmitter e g no hand transmitter has been registered for the receiver yet must be learned directly via the operators main electronic 1 Press the LERN LEARN button on the main electronic for approx 3 seconds until the operator s light starts blinking and release the LERN LEARN button 2 Press the hand transmitter button you want to register to the receiver the operators ligh
4. industrial environments St raussendung f r Wohnbereich Gesch fts und Gewerbereiche sowie Kleinbetriebe EN 61000 6 2 2001 Generic standards Immunity for industrial environments Fachgrundnorm St rfestigkeit Industriebereich Low Voltage Directive EN 60335 2 95 2001 7 Niederspannungsrichtlinie Particular requirements for drives for vertically moving garage doors for residential use Anforderungen f r Antriebe von Garagentoren mit Senkrechtbewegung zur Verwendung im Wohnbereich EN 60335 1 1994 A1 1996 A2 2000 A11 1995 A12 1996 A13 1998 A14 1998 A15 2000 A16 2001 Safety of household and similar electrical appliances Sicherheit elektrischer Ger te f r den Hausgebrauch Safety in Use EN 12453 2000 Nutzungssicherheit Safety in use of power operated doors requirements Nutzungssicherheit kraftbet tigter Tore Anforderungen EN 12445 2000 Safety in use of power operated doors Test methods Nutzungssicherheit kraftbet tigter Tore Pr fverfahren ps bs Peter Seip Gesch ftsf hrer Walzbachtal J hlingen 16 06 2003 ANTRIEBS P Grombacher Stra e 83 75045 Walzbachtal J hlingen Germany www seip com EC Declaration of Confirmity EG Konformitatserklarung in accordance with the Radio and Telecommunications sate dem pies ae Rao Gadde Leth Terminal Equipment Act FTEG and Directive 1999 5 EC UNIKABONSENAEINEIEHEUNGEN UNG GEF ISENEINNE x y x Document No FU 16062003 x Dokum
5. nally or accidentally Your garage door may be above your cars roof and you may not be aware that the door has started moving Always watch the moving door and keep persons away until the garage door is either completely opened or closed Do not leave any obstacles in the garage doors operating range Obstacles such as bicycles left momentarily could be damaged when the operator is activated by another user The emergency release must be used with care when the garage door is opened the door might fall down if the springs are broken Before using the emergency release on an opened door your must ensure that neither persons nor obstacles are within the doors moving range Check the installation regularly for damages Check the automatic reversion monthly using a 40 mm high obstacle Check the function every time adjustments or changes are made to the garage door Should problems occur with your remote control then ple ase contact your dealer Repairs should only be carried out by an authorised dealer The light bulb may be exchanged by taking off the ope rators front cover Please unplug the power cord before taking off the front cover The remaining parts of the operator may only be opened by authorised personnel 4 channel MIDI transmit ter 433 MHz standard equipment Wall push button IP 44 standard equipment 2 channel MINI transmitter 433 MHz optional extra Key switc
6. ator with a push of button which is installed in his car Once programmed the driver does not need the hand transmitter to access the garage with his car The standard remote control supplied with the TS series is com patible with HomeLink systems manufactured by end of year 2002 beginning of year 2003 subject to technical alterations The procedure how to program the HomeLink device is de scribed in the car s manual please refer to those instructions Basic information on programming you first must register the hand transmitter with the operator The HomeLink system will then learn the code from the hand transmitter Please avoid to drop the hand transmitter parts could be damaged inside the transmitter That might lead to malfunctions Should a problem occur Most occuring problems are not necessarily caused by the operator but by the garage door Your TS operator is equipped with an automatic force measurement Dur ing the installation the operator memorises how much force it needs to open and close your garage door Changes to the door weight caused by the weather the door might go out of alignment slightly due to hot or cold weather conditions will not affect the operation of your door operator The operator will also adjust itself to the normal and slow changes of your garage doors performance caused by ageing In contrast rapid changes to the weight of the garage door will be recog nised by
7. ent Nr FU 16062003 x x y We Wir Seip Antriebstechnik GmbH Grombacher Stra e 83 75045 Walzbachtal J hlingen Deutschland declare that the product erkl ren da das Produkt SKR 433 Code B43A023004 Hand Transmitter as remote control for garage door operators Handsender als Fernbedienung f r Garagentorantriebe Short Range Device Funkger t geringer Reichweite SRD complies with the essential requirements of 3 and the other relevant provisions of the FTEG Article 3 of the R amp TTE Directive when used for its intended purpose bei bestimmungsgem er Verwendung den grundlegenden Anforderungen des 3 und den brigen einschl gigen Bestimmungen des FTEG Artikel 3 der R amp TTE entspricht 3 1 1 Article 3 1 a does not refer to this type of product 3 1 1 Artikel 3 1 a bezieht sich nicht auf diesen Produkttyp es gibt hierzu keine Norm Protection requirement concerning electromagnetic compatibility 83 1 2 Article 3 1 b Schutzanforderungen in Bezug auf die elektromagnetische Vertr glichkeit 3 1 2 Artikel 3 1 b EN 300 220 1 1997 EN 300 683 1997 EMV EMC Directive 89 336 EEC 92 31 EEC 93 68 EEC Be by Peter Seip Gesch ftsf hrer Walzbachtal J hlingen 16 06 2003 Out ANTRIEBS P Grombacher Stra e 83 75045 Walzbachtal J hlingen Germany www seip com
8. er button you want to use The operators light stops blinking the transmitter was succesfully programmed Quick reference Programming additional hand transmit ters from a distance Remark additional hand transmitters can be programmed either like the first transmitter or from a distance as explained below 1 Open the garage door After the garage door is closed for approx 50 cm and close you have got 10 seconds to pro it again ceede to step 2 2 Press buttons 1 2 simultaneousely on any registered transmitter for 3 sec The operators begins blinking release the hand transmitters buttons 3 Take the new hand transmitter and press the button you want to use shortly The operators light stops blinking the hand transmitter was successfully programmed 4 channel MIDI transmitter 433 MHz rolling code 4 Usable types of batteries A23 23A 23L EL12 VR 22 and MN 21 Voltage 12V Used batteries must be disposed of according to national laws Criterias influencing the range The TS operators are equipped with a high quality remote control set as a standard Nevertheless the remote control is the part of the operator which might be influenced by circumstances in the surroundings of the garage With our standard remote control you might reach a range of more than 100 meters In areas with high disturbancies the range will still be approx 50 meters The range might be influenced by
9. h optinal extra Using the Operator Devices There are different devices available to activate your operator Standard Equipment MIDI hand transmitter 4 channel Wall push button Optional Extra Key switch MINI hand transmitter 2 channel Code Lock other devices for example special entry systems The devices may be used alongside each other Usage The operator follows the principle OPEN STOP CLOSE This princi ple is valid for any device Starting from closing position of the door this means First impulse the door opens Second impulse the door stops Third impulse the door closes Fourth impulse the door stops Fifth impulse the door opens and so on Usually it will not be necessary to stop the operator during opera tion unless you realise there is an unexpected obstacle within the doors range Please also refer to the Safety Instructions on page 2 The operator registers an obstacle by touching it the garage door hits the obstacle and reverses to set the obstacle free again Dependant on the make of the garage door slight damages might occur on obstacles a cars paintwork might become scratched With an additional security device like a photocell optional extra the operator will stop as soon as an obstacle is recognised by the photocell Should the door be in the opening position the opera tor will only close the door once the obstacle has been removed from the photocells range
10. range of the garage door before using the emergency release EG Konformitatserklarung im Sinne der EG Richtlinien Niederspannungsrichtlinie 73 23 EWG mit Anderungen EC Declaration of Confirmity Low Voltage Directive 73 23 EEC and amendments Electro Ma gneticalCompatinility 89 336 FEC x Elektromagnetische Vertr glichkeit 89 336 EWG and amendments x mit Anderungen x Document No AN 16062003 Dokument Nr AN 16062003 A y We Wir Seip Antriebstechnik GmbH Grombacher Stra e 83 75045 Walzbachtal J hlingen Deutschland hereby declare that the following products comply to the mentioned EC regulations erkl ren hiermit da die nachfolgenden genannten Produkte den unten angegebenen EG Richtlinien entsprechen Type of Product Produktart Garage Door Operator Torantrieb Product Name Modell TM 60 TS 75 TS 100 SE 130 TS Approved according to 89 336 EEC and 73 23 EEC Gepr ft nach 89 336 EWG und 73 23 EWG Referring EC regulations Angewandte harmonisierte Normen Electromagnetic Compatibility EN 61000 3 2 2000 Elektromagnetische Vertr glichkeit Limits for harmonic current emissions Grenzwerte f r Oberschwingstr me EN 61000 3 3 1995 Corrigendum 1997 A1 2001 Limitation of voltage changes voltage fluctuations and flicker in publik low voltage supply systems Grenzwerte f r Spannungsschwankungen und Flicker EN 61000 6 3 2001 Emission standard for residential commercial and light
11. t stops blinking when the transmit ters signal was received The transmitter is now registered Registering additional hand transmitters When at least one hand transmitter has been registered by the receiver you may program additional hand transmitters from a distance 1 The garage door must be closed 2 Open the garage door approx 50 cm and close it again 3 After the garage door is closed you have got 10 seconds to press the buttons 1 2 simultaneously on the registered hand transmitter the operator s light then starts blinking 4 The light will keep blinking for another 10 seconds during that period of time you must press the button on the new hand trans mitter which you want to use with the operator Once the new transmitter is registered the operator s light stops blinking The procedure must be repeated for each new hand transmitter Clearing the receivers memory Keep the LERN LEARN button pressed for approx 15 sec The operators light and the red LED Diag will start blinking after 3 seconds After another 10 seconds the red LED DIAG will glow constantly You can then release the LERN LEARN button All previousely programmed hand transmitters are now cleared from the receivers memory Quick reference programming the first hand transmitter 1 Keep the LERN LEARN button pressed for approx 3 sec The operators light will start blinking 000000000 2 Press the hand transmit t
12. tacles are removed from the photo cells range of observation check if there is dirt on photo cell clean if necessary check if the hatch door is closed If the operators light is still blinking after checking all devices then please contact your dealer The dealer will also find it helpful if you counted the number of blinks given by the operators light it may give a hint concern ing the problem In case of a power failure You can disconnect your garage door from the operator using the emer gency release The emergency release is fitted to your operator in either way shown on the diagrams on the right If your garage door is the only entrance to your garage then you can disconnect the operator by using your garage doors lock and handle Unlock the door and turn the handle the operator will be disconnected automatically and you can open your door by hand If you have got a seperate entrance to your garage then you can enter your garage and pull the cord hanging down in front of your garage door The operator will be disconnected and the door can be opened by hand ATTENTION It might be dangerous disconnecting the operator from an open garage door If the doors springs are damaged or the door is not well balanced then it might drop down there is a high risk of injuries and damages If however you cannot avoid disconnecting the operator from an open garage door then you must make sure that there is no one within the
13. the operator the operator will then behave as if it had registered an obstacle In CLOSING directionthis means that the operator stops and reverses into opening direction to release a supposed obstacle In OPENING direction it means that the operator will stop and reverse a few centimetres into closing direction to release a supposed obstacle Dur ing the soft stop period in CLOSING direction the operator will reverse for a few centimetres the door will always remain open a few centimetres Rapid changes normally occur when a spring of your garage door is broken especially when the springs are covered by protectors you might not recognize the damage mechanical damages to the garage door happened e g by hitting the door with a car a new surface was attached to the garage door or the whole door was exchanged e g an increase of the doors weight In all of these cases the garage door needs to be maintained please contact your dealer When the operators light is blinking The operator is also equipped with an error system if an error should occur then the operators light will start blinking when you try to activate it The blinking light refers to errors caused by external devices the fol lowing steps only need to be followed if any of the devices mentioned are connected to your operator check all security devices connected to your operator photocell security beam or hatch door switch check that all obs