Home

Installation and Operating Instructions

image

Contents

1. insert the shorter osf pin delivered with the device in the middle of the hole in the valve shaft If the pin is too loose in the hole it can be fastened with a little adhesive or grease to facilitate mounting of the controller For later operation of the system it is immaterial whether the pin is loose because it is centred by the housing of the controller Preparation of the controller The controller must be in the position Filter position on delivery To equalise height differences of the valve shafts it is necessary in the case of some valves to stick one or more of the self adhesive spacer disks delivered with the device under the housing of the controller Proceed as follows to determine whether one or more spacer disks are needed Move the 6 way valve into the position Filter Mount the EUROTRONIK 10 on the valve without spacer disk See Mounting of the EUROTRONIK Push the feeler gauge delivered with the device between the EUROTRONIK and valve If the feeler gauge fits between the EUROTRONIK and valve exactly the gap is optimal agent feeler gauge If the EUROTRONIK wobbles on the valve one or more spacer disks must be stuck under the EUROTRONIK see sketch below Thereafter the EUROTRONIK must be mounted again and the test with the feeler gauge repeated After mounting it is irrelevant whether the feeler gauge remains inserted or is removed If the feeler gauge is removed the resultant play has
2. the 6 way valve can be moved into the position Empty The key for this is also located in the housing cover For maintenance purposes the valve can also be moved into the position Closed with a further key The respective valve position and position changes can be read on an LCD display in the housing cover without having to open the housing The valve disk is lifted before turning to protect the star seal The pump is switched off during this time Technical specifications Dimensions 245mm x 140mm x 95mm Power supply 230V 50Hz Power consumption of the controler Breaking capacity max 1 1 kW AC3 Motor operated valve 230V System of protection IP 54 Usable valves Praher 11 and 2 Ambient conditions 0 40 max 95 r H non condensing Speck 11 2 and 2 Midas 11 2 and 2 Astral 11 2 With appropriate adapter Astral 2 Hayward 112 Static water pressure O Water column above the valve max 3 0m Operating Instructions EUROTRONIK 10 Page 2 Table of contents Page Function 1 Technische Daten 1 Mounting 3 Preparation of the 6 way valve 3 Preparation of the controller 3 Mounting on an Astral 2 valve 4 Mounting on Astral Midas and Hayward valves 4 Mounting of the EUROTRONIK 4 Electrical connection 4 Connection of any 230 V filter controller 5 ae Connection to a filter controller of the series BET Peeicontroi Pws 6 ae Connection to an filter controller in the series TE meeicontror 6 Operating e
3. the EUROTRONIK switches the filter pump off when the valve is moved The contact K2 causes a forced switching on of the filter pump during backwashing cycles outside the filter times Operating Instructions EUROTRONIK 10 Page 7 The contact K1 in the EUROTRONIK supplies the terminal U2 with power during backwashing and clear rinsing while for the rest of the time the terminal U3 is live A motor operated valve can be connected to these terminals to replenish the water lost during the rinsing cycles The contact K4 in the EUROTRONIK is only closed when the valve is in the final position Backwash and can be used to operate an additional backwash pump The osf pressure switch art no 2000599015 can be connected to the terminals 70 and 77 It is screwed into the manometer connection in the 6 way valve The metal body of the pressure switch must be grounded This switch triggers a backwashing cycle when the pressure limit that has been set is exceeded irrespective of how the switch clock in the EUROTRONIK has been programmed LCD display Controller ON OFF Backwash manual Set time Program switch clock Operating elements s 9 EUROTRONIK 10 Close valve Empty swimming pool Change values Backwash and clear rinsing times LCD display Do 14 46 Normal operating display showing the current time and valve position Filtern Heben gt The backwashin
4. Installation and Operating Instructions EUROMEITRONIK 10 CE Art no 3104811201 Function The electronic backwash controller EUROTRONIK 10 makes it possible to expand an existing filter controller e g filter controllers in the PC or PCP series into an automatic filter and backwash controller The EUROTRONIK which is mounted on the 6 way valve with a protected quick coupling automatically moves the valve into the correct position and operates the filter pump The time of the backwashing and clear rinsing cycles is adjustable and can be seen in the LCD display The switch contacts to operate the filter pump are floating contacts so that the EUROTRONIK 10 can be combined with as many types of filter controller as possible The backwashing cycle can be carried out both on a time control by way of the integrated digital switch clock as well as pressure dependent basis The adjustable pressure switch art no 2000599015 is not included in the delivery package It is also possible to start the backwashing cycle manually with a key in the housing cover A connection for a 230 V motor operated valve enables withdrawal of the water needed for the backwashing cycle directly from the swimming pool instead of from the overflow collecting tank and replenishment of fresh water during backwashing An additional floating relay contact can be used during backwashing to operate a second pump backwash pump or blower To empty the swimming pool
5. RONIK contains electronic components that react sensitively to the discharging of static electricity the tools used must first be discharged by touching a grounded metal part The electronic components should not be touched as far as possible Operating Instructions EUROTRONIK 10 Page 10 ay j Fortnightly E intermittent backwashing Intermittent backwashing The EUROTRONIK 10 offers two possibilities of controlling the filter pump during backwashing a Constant backwashing with continuous operation of the filter pump during the complete backwashing time b Intermittent backwashing with repeated switching on and off of the pump during the backwashing time for better loosening of the filter sand The right switch in the DIP switch is used to switch between intermittent backwashing and constant backwashing The bottom switch position is for constant backwashing factory setting and the top switch position for intermittent backwashing Fortnightly backwashing If in the case of pools subject to little use a backwashing cycle is only to be started every second week the left switch in the DIP switch must be switched into the top switch
6. d the last time displayed is saved automatically and the normal operating display appears again Programming the switch clock The integrated weekly switch clock for automatic backwashing and clear rinsing is Ci programmed with the key I Operating Instructions EUROTRONIK 10 Page 9 Dauer 1 Press the key k Ruck 120 appears in the display 2 The desired duration of backwashing in seconds can then be set with the keys J and Vv The maximum backwashing time that can be set is 900 seconds 15 minutes If a backwashing time of 0 seconds is set the switch clock is inoperative Dauer 3 Press the key Ef again gt Klar 10 appears in the display 4 The desired duration of clear rinsing in seconds can then be set with the keys J and v The maximum clear rinsing time that can be set is 120 seconds 2 minutes 5 Press the key les again gt 1 Spul appears in the display 6 The desired point in time for backwashing can then be set with the keys 5 and v 7 Further backwashing cycles can then be programmed as described in points 5 and 6 A total of 15 backwashing cycles per week can be programmed 8 To save the switch times press the key J again If during setting more than 10 seconds pass without a key being pressed the last switch time displayed is saved automatically and the normal operating display appears again If backwashing times have already been programmed they ca
7. e pressure limit that has been set is exceeded irrespective of how the switch clock in the EUROTRONIK has been programmed Modern filter controllers from ost from 1994 on are already equipped with special terminals for connection to EUROTRONIK backwash controllers They simplify connection of the filter controller to the EUROTRONIK and also make it possible to use 400 V rotary current pumps Operating Instructions EUROTRONIK 10 Page 6 ae Connection to a filter controller of the series GE reexconto Pws EUROTRONIK 10 P Pressure switch Mains 4 Backwash pump 230V 50Hz 230V max 1 1kW e ri Moto operated 4 valve m ry a PELcoNtol Filter pump The connection between the EUROTRONIK 1 and PCP filter controller is limited to four wires The filter pump heater and dosing equipment remain directly connected to the PCP The contact K3 of the EUROTRONIK switches the filter pump off when the valve is moved The contact K2 causes a forced switching on of the filter pump during backwashing cycles outside the filter times The contact K1 in the EUROTRONIK supplies the terminal U2 with power during backwashing and clear rinsing while for the rest of the time the terminal U3
8. g cycle has been started The valve disk is first lifted Ruckspul Drehen gt The valve disk is turned into the position Backwash Ruckspul Senken gt The valve disk is lowered into the position Backwash Ruckspul 4 39 The backwashing cycle is running The remaining backwash time is displayed in R cksp l min sec Heben gt After backwashing the valve disk is lifted again Klarsp l Drehen gt The valve disk is turned into the position Clear Rinse Klarsp l Senken gt The valve disk is lowered into the position Clear Rinse Klarsp l 0 10 The clear rinsing cycle is running The remaining rinsing time is displayed in Klarsp l min sec Heben gt The valve disk is lifted to be turned into the position Filter Filtern Drehen gt The valve disk is turned back into the position Filter Filtern Senken gt Filtern Heben gt Entleere Drehen gt Entleere Senken gt Entleere Pumpe an Entleere Heben gt Geschl Drehen gt Geschl Senken gt Geschl Ventil Geschl Heben gt ausgesch Drehen gt ausgesch Senken gt ausgesch Ger t ist aus Schalter defekt Operating Instructions EUROTRONIK 10 Page 8 The valve disk is lowered into the position Filter The valve disk is lifted to be turned into the position Empty The valve disk is turned into the position Empty The valve disk is lo
9. ge 13 Servomotor This line shows whether the servomotor in the EUROTRONIK to turn the 6 way valve is on or off The following displays are possible Servomotor OFF The servomotor is off Servomotor UP The servomotor lifts the valve disk or turns it into the next position Servomotor The servomotor lowers the valve disk DOWN When the servomotor is shown in the top line of the service terminal it can be switched on or off 1 The following display appears after pressing the key I Stellmotor AUS Handsteuerung des Antriebes 6 Wege Ventil 2 The valve disk can be lifted and turned with the key A Renewed pressing of the key A switches the servomotor off again 3 The valve disk can be lowered into one of the valve positions with the key V The motor is switched off when the bottom final position is reached or the key is pressed again 4 The normal diagnostics display reappears when the key J is pressed again Note The drain of the swimming pool must be installed in such a way that the pipe Is higher than the water level at least at one point A suitable ventilation valve must be installed at the highest point The function of this ventilation valve is to ventilate the drain pipe whenever the filter pump is not in operation This then prevents unnecessary water loss in the event of a leaking multiple way valve These installation and operating instructions must be observed We wish you lots of fun and relaxati
10. ible Interlock OFF The relay contact between terminals 3 and 5 K3 is open the filter pump is disabled Interlock ON The relay contact between terminals 3 and 5 K3 is closed operation of the filter pump is enabled When the interlock is shown in the top line of the service terminal it can be switched on or off Operating Instructions EUROTRONIK 10 Page 12 1 The following display appears after pressing the key Verriegelung AUS Handsteuerung des Kontaktes zw Klemmen 3 5 2 The filter pump can be enabled with the key Al K3 closed and disabled again with the key V K3 open 3 The normal diagnostics display reappears when the key H is pressed again Forced switching on This line shows whether the EUROTRONIK switches on the filter pump during backwashing clear rinsing or emptying The following displays are possible Forced on OFF No switch on command from the EUROTRONIK K2 open Forced on ON The EUROTRONIK has switched on the filter pump K2 closed When the forced switching on is shown in the top line of the service terminal it can be switched on or off 1 The following display appears after pressing the key I Zwangseinsch AUS Handsteuerung des Kontaktes zw Klemmen 2 4 2 The filter pump can be switched on with the key Al K2 closed and switched off again with the key V K2 open 3 The normal diagnostics display reappears when the key 1 is pressed again Auxiliary pump Thi
11. is live A motor operated valve can be connected to these terminals to replenish the water lost during the rinsing cycles The contact K4 in the EUROTRONIK is only closed when the valve is in the final position Backwash and can be used to operate an additional backwash pump The osf pressure switch art no 2000599015 can be connected to the terminals 70 and 77 It is screwed into the manometer connection in the 6 way valve The metal body of the pressure switch must be grounded This switch triggers a backwashing cycle when the pressure limit that has been set is exceeded irrespective of how the switch clock in the EUROTRONIK has been programmed Connection to an Hi filter controller in the series Mi Poaircontor e g PC 230 PC 230 ES PC 230 ES Special PC 400 PC 400 ES PC 400 ES Special PC 25 PC 2000 EUROTRONIK 10 Pp Pressure switch Mains Backwash pump 230V 50Hz 230V max 1 1kW P Motor operated valve ee ae a RTA i PaaLcontrol _c Filter pump The connection between the EUROTRONIK 1 and filter controller is limited to four wires The filter pump heater and dosing equipment remain directly connected to the filter controller The contact K3 of
12. lements 7 LCD display 7 Switching the controller on off 8 Setting the time 8 Programming the switch clock 8 Backwashing manual 9 Emptying the swimming pool 9 Closing the valve 9 DIP switch on the upper circuit board 9 Intermittent backwashing 10 Fortnightly backwashing 10 Service terminal only for service personnel 11 Operating cycles of the backwash controller 11 Input signals 11 Microswitch 11 Light scanners 11 Interlock 11 Forced switching on 12 Auxiliary pump 12 Motor operated valve 12 Servomotor 13 Operating Instructions EUROTRONIK 10 Page 3 Mounting The controller must be mounted in accordance with its system of protection so that it is protected against moisture The ambient temperature should lie between 0 C and 40 C and should be as constant as possible The relative humidity should not exceed 95 and no condensation should occur Direct incidence of heat or sunlight on the device must be avoided The power supply to the device must be connected via an all polar main switch with a contact gap width of at least 3 mm The device must be switched off before the housing is opened Shorter osf pin Preparation of the 6 way valve Before mounting the EUROTRONIK it must be ensured that the valve moves easily and is free of dirt The 6 way valve must be in the position Filter when mounting the controller In this position the handle of the valve must be removed by driving the fastening pin out of the valve shaft Then
13. n be deleted with the key I 1 Press the key J repeatedly until the backwashing time that is to be deleted appears in the Mi 14 00 display 2 Spul 2 Set the backwash time on 2 Spul with the keys and between Sun 23 59 and Mon 0 00 To delete the switch time press the key J again Backwashing manual i A backwashing cycle can be started manuall at any time irrespective of how the switch clock has been programmed with the key L The duration of the backwashing cycle is the same as that entered during programming of the switch clock This key can also be used to end a backwashing cycle already in progress Emptying the swimming pool I When the key is pressed for longer than 5 seconds the valve is turned into the position Empty and the filter pump switched on Emptying can be stopped by pressing this key again Closing the valve me The key is used to turn the valve into the position Closed for service purposes In this PN valve position the filter pump is disabled The valve is turned back into the position Filter by pressing this key again DIP switch on the upper circuit board Intermittent backwashing and fortnightly backwashing can be activated with a DIP switch on the upper circuit board inside the EUROTRONIK The housing has to be opened to access these operating elements The power supply to the device must be switched off first Since the interior of the EUROT
14. n the actuator completely to the right approx 453 The slides must then catch in the guide grooves of the valve when released The valve shaft may not be turned with the device when clipping on the controller _ The osf pin in the valve shaft must now be caught in the slot of the coupling Electrical connection Only authorised electricians may carry out electrical connection balancing and service work The following connection diagrams and all valid safety regulations must be followed When working on the open housing precautions must be taken to protect the electronic components against electrostatic discharges Operating Instructions EUROTRONIK 10 Page 5 Connection of any 230 V filter controller EUROTRONIK 10 Pressure switch Backwash pump _230V max 1 1kW Mains 230V 50Hz r Motor operated valve st o pam E Output o PAMP Filter pump Filter controller 230V 230V max 1 1kW g All conductive components must be integrated in the local equipotential bonding system In the case of the mains connection it must be ensured that both controllers work on the same phase L1 The contact K3 in the EUROTRONIK is closed when the
15. no negative influence on the operation of the system Operating Instructions EUROTRONIK 10 Page 4 Mounting on an Astral 2 valve A special adapter is needed for mounting on an Astral 2 e valve This adapter is placed on the valve in such a way that we Final e the screws point downwards and catch in the recesses in the valve e the two recesses on the side point to the words Filter and Backwash These adapters are obtainable from MEI under the article number 1200299200 Mounting on Astral Midas and Hayward valves Since the guide grooves in the valve bonnets of Midas Astral and Hayward valves are narrower the two yellow slides on the bottom of the controller must be replaced by the red slides delivered with the device when using these types of valve Replace slides if necessary It s not allowable to use a Astral Valve with bayonet lock Stick on spacer disks if necessary Mounting of the EVROTRONIK Press the two slides yellow or red in completely at the same time Place the controller on the valve carefully so that the coupling of the controller encompasses the valve shaft and the pin Slides into the slot of the coupling Make sure that the coupling is not pushed into the housing of the controller when doing so Since the coupling does not always fit on the valve shaft easily because of dimensional tolerances in the case of some valves the housing cover should be closed during mounting Then tur
16. on in your swimming pool Subject to change 6 August 2015 Operating Instructions EUROTRONIK 10 Page 14
17. position If it is in the bottom switch position factory setting every switch command of the switch clock is carried out In the top switch position only one backwashing cycle per week can be programmed with the switch clock This backwash command is only carried out every second week Operating Instructions EUROTRONIK 10 Page 11 Service terminal only for service personnel An osf service terminal art no 3010000900 can be connected to this controller for optimum adjustment of the controller to the different types of swimming pool and to facilitate commissioning an and fault diagnosis The connector for this is mounted on the circuit l board inside the device The power supply to the controller o must be switched off before opening the housing and plugging in the service terminal Plugging the service connector in or out when the device is on can destroy the device The operating time meter appears in the display of the service terminal after switching on the controller e g p Betriebsstunden insgesamt 238 Connector for service terminal Davon einge schaltet 200 Further pages can be called up with the keys A and X If necessary the val
18. s line shows whether the EUROTRONIK switches on an auxiliary backwash pump with the help of the contact K4 The following displays are possible Auxiliary pump OFF The pump is off K4 open Auxiliary pump ON The pump is on K4 closed When the auxiliary backwash pump is shown in the top line of the service terminal it can be switched on or off 1 The following display appears after pressing the key Zusatzpumpe AUS Handsteuerung des Kontaktes zw Klemmen 6 7 2 The backwash pump can be switched on with the key Al K4 closed and switched off again with the key Y K4 open 3 The normal diagnostics display reappears when the key H is pressed again Motor operated valve This line shows whether a motor operated valve is opened or closed by the relay contact K1 The following displays are possible Motor valve CLOSED The motor operated valve is closed terminal U3 is live with mains power Motor valve OPEN The motor operated valve is open terminal U2 is live with mains power When the motor operated valve is shown in the top line of the service terminal it can be opened or closed 1 The following display appears after pressing the key I Motorventil ZU Handsteuerung des Motorventils an Klemmen U2 U3 2 The motor operated valve can be opened with the key A and closed again with the key v 3 The normal diagnostics display reappears when the key lis pressed again Operating Instructions EUROTRONIK 10 Pa
19. ues in the top line can be changed after pressing the key Operating cycles of the backwash controller The following counter statuses are shown Backwash Number of completely carried out backwash cycles Empty Number of emptying cycles Close Number of closing cycles Input signals The current input signals of the EUROTRONIK are shown in this line Pressure switch Switch status of a pressure switch connected to terminals 10 and 11 B fortnightly Switch position of the left DIP switch backwash fortnightly B interval Switch position of the right DIP switch intermittent backwashing Microswitch The current status of the microswitch in the bottom part of the housing which is used by the controller to detect whether the valve disk has been lowered is shown on this page Light scanners The measured values of the light scanners which are used by the controller to detect the valve positions are shown on this page Two values are shown for each of the five light scanners The value in brackets should lie between 30 and 70 The other value should be more than 700 when the housing is open and should fall notably on approaching a reflecting object The following lines enable the service technician to check the output relay of the controller Interlock This line shows whether the relay K3 is on This relay is used to switch off the filter pump when the valve is turned or is in the position Closed The following displays are poss
20. valve has reached one of its final positions This prevents the filter pump from being switched on by the filter controller during the adjusting process The contact K2 in the EUROTRONIK is only closed when the valve is in the final positions Backwash Clear Rinse or Empty The filter pump is then supplied with power by the EUROTRONIK so that a backwashing cycle is also possible outside the filter times set on the filter controller If the possibility of backwashing outside the filter times is not necessary the jumpers between L1 and 2 and between 4 and 5 can be dispensed with Phase coincidence between the EUROTRONIK and filter controller is then not necessary with the result that the filter controller can be supplied with power directly from the mains The contact K1 in the EUROTRONIK supplies the terminal U2 with power during backwashing clear rinsing and emptying while for the rest of the time the terminal U3 is live A motor operated valve 230 V can be connected to these terminals to replenish the water lost during the rinsing cycles The contact K4 in the EUROTRONIK is only closed when the valve is in the final position Backwash and can be used to operate an additional backwash pump The osf pressure switch art no 2000599015 can be connected to the terminals 10 and 11 It is screwed into the manometer connection in the 6 way valve The metal body of the pressure switch must be grounded This switch triggers a backwashing cycle when th
21. wered into the position Empty The valve is in the position Empty The filter pump is on The valve disk is lifted to be turned into the position Closed The valve disk is turned into the position Closed The valve disk is lowered into the position Closed The valve is in the position Closed The filter pump is disabled The EUROTRONIK has been switched off The valve disk is lifted to be turned into the position Filter home position The valve disk is turned into the position Filter home position The valve disk is lowered into the position Filter home position The EUROTRONIK is off The valve is in the position Filter The bottom final position of the valve disk has not been detected The microswitch in the bottom part of the housing is possibly damaged When the fault has been repaired the controller can be switched off and back on again with the key 5 Switching the controller on off power supply to the device If the valve is not in the position Filter when the controller is The controller is switched on and off with the key Note This does not switch off the switched off it is turned there automatically Setting the time The time and weekday are set with the key G Mo 14 46 1 Press the key Uhrzeit appears in the display 2 The time can then be set with the keys A and Y To save the time press the key again If during setting more than 10 seconds pass without a key being presse

Download Pdf Manuals