Operating Instructions Surface-mounted outdoor station with
Contents
1. stripped bus line with approx 5 mm of insulation into the bottom section of the housing 5 Mount the bottom section of the housing to the wall with the accompanying screws Push the PCB downward to screw in the upper mounting screws 6 Connect the 2 wire bus to the bus terminals S S 5 od iJ Jumpers between BUS and ZV The wire jumpers between BUS and ZV are required for opera ay BUS tion of the colour camera Thus the illumination of the call but tons at the outdoor station cannot be switched off If an external supply is connected to the ZV terminals the jump ers between ZV and BUS must be removed Start up 7 Push the PCB into the upper position 8 Set the camera lens in the desired direction see Setting range of coverage Page 10 9 Remove the protective film on the lens 10 Attach the camera cover 11 Ensure proper seating of the speech cover and colour cam era sealing rings 12 Set the upper section of the housing in place press on it firmly and screw in the Torx screws i Measures for theft protection Instead of using Torx screws you can also use the optional Tri Wing screws to secure the top section of the frame Once you have installed all of the devices outdoor and home stations video control unit etc you can start up the door com munication system Start up is described in the system manual included with the video control unit Ran
2. Operating Instructions Surface mounted outdoor station with colour camera and call push button 1 gang 1269 65 66 67 Surface mounted outdoor station with colour camera and call push button 2 3 gang 1270 65 66 67 GIRA Table of contents Device description Functional scope of the colour camera Selection of the installation site senenenee 6 Mounting wae ed Start up nn NR Bar 8 Range of coverage of the colour camera eee 9 Setting range of coverage Operations ie eee eee essen Changing theilabel pl tess 2 kenne se Technical data Acceptance of guarantee Device description The surface mounted outdoor station with colour camera is a prefabricated unit and is part of the Gira door communication system The basic structure of a surface mounted outdoor station is pre sented in the example of the surface mounted outdoor station with colour camera and call push button 2 3 gang 1 2 3 4 5 1 hoy v O 0000 0000 ooo0o00 d ooooo0 2 c IE I j 9 8 7 6 1 Housing bottom section 6 Call push button covers 2 Colour camera 7 Housing top section 3 Cable inlet 8 Speech cover 4 Connection terminals 9 Call push button 3 gang 5 Sealing rings Functional scope of the colour camer
3. a The colour camera of the flush mounted outdoor station has the following product features Automatic day night switching The camera switches from daytime operation colour presenta tion to night mode black and white presentation and back again at an ambient brightness of 1 lux Good display results are achieved due to the high degree of light sensitivity in night mode even with poor lighting conditions up to 0 1 lux The integrated white LEDs ensure an even field of view illumina tion in night mode Large range of coverage The colour camera can be swivelled manually by 20 horizontally and vertically during start up A very large field of view in the door entry area results in conjunction with the 100 range of coverage of the camera Camera heating The integrated temperature dependent camera heating pre vents condensation from forming on the camera cover due to changing weather conditions and thus provides a clear view Camera cover The splash water resistant cover made of impact resistant plas tic can be easily replaced if damaged e g through vandalism Selection of the installation site The selection of the installation site and good illumination are critical for good picture quality No backlighting Do not point the camera toward strong background lighting such as streetlamps or yard illumination Prevent strong sunlight from hitting the lens Picture background Avoid pointing the camera t
4. a video control unit 3rd and 4th camera via external additional supply 24 V DC 2 system bus plug strips video plug strip plug strip connection for future applications CCD sensor 1 3 50 aperture angle 00 angular coverage of the camera 40 with 20 swivelling PAL 500 H x 582 V 380 TV lines 1 lux 0 1 lux up to 1 100000 s 1 20 m 1 50 m 20 C to 50 C Acceptance of guarantee The warranty is provided in accordance with statutory require ments via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center Gira Giersiepen GmbH amp Co KG Elektro Installations Systeme Postfach 1220 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de GIRA 10 41 01 82 22 11
5. e outdoor station Exit programming mode at the control unit by briefly press ing the Systemprogr button M Meier ON Licht Ov Initiating a call ringing Press the call push button to trigger a call tone at the assigned home station The button press is confirmed by an additional acknowledgement tone Switching light on in conjunction with a switching actuator Press the call push button to switch on light or another device via an assigned switching actuator The button press is con firmed by an additional acknowledgement tone Changing the label plates To change the label plates the call push button cover can simply be lifted up Carefully lift the call push button cover e g with a screwdriver 2 Change the label plate 3 Replace the call push button cover and press on it firmly Suitable label plates can be obtained with the optional Gira label ling software and the appropriate Gira labelling sheets Technical data Power supply Connections of camera insert Image capture element Wide angle objective Visible range of coverage Detectable area Colour system Pixels Horizontal resolution Switching threshold colour to B W operation Light sensitivity in B W operation Electronic shutter close time Camera inst height min height Recommended installation height Temperature range 2 cameras vi
6. era lens is adjusted properly and whether the view of a person in front of the door is optimal Lock the lens carrier by tightening both Torx screws again 6 Remove the protective film on the lens 7 Reattach the camera cover 8 Set the upper section of the housing in place press on it firmly and screw in the Torx screws Operation 1x 1x 3s ix Systemprogr us ee L SITZ 1 Systemprogr r g Volume setting The volume can be set separately at each outdoor station The volume setting must be made by two people 1 Start programming mode at the control unit by pressing the Systemprogr button for 3 seconds until the yellow LED next to the button starts flashing Briefly press a previously assigned call push button at the outdoor station The second person accepts the door call at the home sta tion via receiver or speech button and starts speaking Briefly press the call push button at the outdoor station again The volume changes when the button is pressed during the voice connection There are five volume levels in total The next highest volume is set with each button press When the loudest volume level is reached the next button press sets the quietest volume level End the voice connection The most recently set volume level is saved in th
7. ge of coverage of the colour camera The CCD sensor element of the colour camera has an angular coverage of 100 If this angular coverage is not sufficient for your installation sce nario you can swivel the area to be captured by 20 in all direc tions Outdoor station Front door Range of coverage of the camera in non swivelled state Outdoor station Front door Range of coverage of the camera when it is swivelled by 20 Setting range of coverage i Protective lens film The protective film on the lens of the colour camera protects the sensitive optics from scratches and soiling Leave this film on the lens as long as possible and avoid touch ing the lens directly after the protective film has been removed 1 Remove with the housing frame open the gt O oo cover from the colour camera 2 Slightly loosen both Torx screws to the left and lt gt Q a gt right of the camera lens e 1 Do not screw the screws out completely When adjusting the lens carrier it is sufficient to slightly loosen he screws Do not completely unscrew the screws from their brackets 3 Set the camera lens in the desired direction 4 At the TFT display of the connected home sta tion check whether the set angle of the cam
8. oward extremely light picture back grounds and backgrounds with stark contrasts Illumination LEDs integrated in the camera provide even field of view illumi nation in the darkness i Black and white mode in poor lighting conditions In poor lighting conditions lt 1 lux or with the field of view illu mination switched on the colour camera provides black and white pictures only If the entry area is equipped with additional illumination ensure that the light source does not shine directly into the camera from the front The best installation site of an external light source is above the colour camera Installation height The recommended installation height of the colour camera is 1 50 m At this installation height people with an average height of 1 80 m are presented optimally The minimum installation height is 1 20 m Mounting A Attention Installation and mounting of electrical devices may only be car ried out by a qualified electrician i Movable PCB The PCB can be pushed downward for mounting and for con nection of the bus line 1 Select the installation site The cable duct leading into the bottom section of the housing is used for line guidance The installation height of the outdoor station can be varied via the line outlet in this way 2 Mark the mounting holes using the hole template part of the packaging 3 Drill the holes 6 mm and insert the accompanying plugs 4 Guide the