PDC – Pulse Data Capture Modul Montage- und
Contents
1. 6 M Bus modules The PDC as M Bus module is used for integra tion of water meters in wired M Bus networks Connecting PDC M Bus modules with impulse emitting water meters enables reading of the water meter via Bus Technical specifications PDC M Bus Number of conductors 2 Cable length 15m Electromagn fulfils the European Compatibility Directive 89 336 EEC Cable assignment white M Bus 1 brown M Bus 2 Fig Connection sketch PDC M Bus INPUT A en Bus a INPUT B M BUS 2 7 AES Key The PDC modules send their data contents only encrypted AES 128 device specific According to OMS To enable reception of the data contents and their further processing the AES Key has to be furnished to the respective recipients of the AES Key ZENNER provides the AES keys to the devices usually by means of electronic delivery and via download or customer specific file in the future 8 Readout data logger The PDC modules have an internal memory data logger The readout of the data which are not al ready transmitted in the above data telegrams is carried out by means of the optical interface using MinoConnectRadio the ZR optical head IrCombi Head and appropriate software Data logger See point 2 Table General Specifications 13 9 Smart Meter functions Self monitoring The module has an integrated battery status monitoring Leakage detection If over a period of 24 hours 96 quarter hour values
2. This is averaged over a 15 minute period In the event store date and time of the event are stored Pipe burst detection For PDC M Bus Pipe burst is detected when the flow rate has exceeded a given value gt 30 of Q3 during a 30 minute period This is aver aged over a 15 minute period In the event store date and time of the event are stored 10 Disposal Attention This device contains a non remova ble and non rechargeable lithium battery Batteries contain substances which could harm the environment and might endanger human health if not disposed of properly To reduce the disposal quantity so as unavoid able pollutants from electrical and electronic equipment in waste old equipment should be reused prior or materials recycled or reused as another form This is only possible if old equipment which con tains batteries or other accessories are disposed Therefore please contact the department of your local authority which is responsible for waste disposal Alternatively a waste disposal via ZENNER is possible Your local or municipal authority or the local waste disposal company can give you informa tion relating the collection points for your used equipments ZENNER International GmbH amp Co KG R merstadt 6 D 66121 Saarbr cken Telephone 49 681 99 676 30 Telefax 49 681 99 676 3100 E Mail info zenner com Internet www zenner com Attention Do not dispose of the devices with domestic was
3. su richiesta S1 C1 AES 128 secondo le specifiche OMS specifica per dispositivo su richiesta specifica per cliente valore data di scadenza valore mensile valori mensili storici Informazioni di stato typisch 20 40s 25 mW 6 Moduli M Bus II PDC come modulo M Bus viene utilizzato per integrare i contatori dell acqua nelle reti cabla te M Bus Collegando i moduli PDC M Bus con i contatori dell acqua ad emissione di impulsi possibile effettuare la lettura del contatore dell acqua tramite bus Specifiche tecniche PDC M Bus Numero dei 2 conduttori Lunghezza cavi 1 5 m Compatibilit elettro alla direttiva europea magnetica conforme 89 336 CEE Assegnazione cavi bianco M Bus 1 marrone M Bus 2 Illustrazione Schema di collegamento PDC M Bus INPUT A END Bus a INPUT B M BUS 2 GND 7 AES Key I moduli PDC trasmettono i propri pacchetti dati soltanto crittografati AES 128 specifica appa recchi conforme alle indicazioni OMS Per con sentire la ricezione dei pacchetti dati e la loro ela borazione nei rispettivi destinatari va impostata la AES Key Generalmente ZENNER fornisce le AES Key dei dispositivi tramite invio elettronico in futuro sar possibile anche tramite download o mediante un file creato specificamente per il cliente 8 Lettura del logger dati moduli PDC dispongono di una memoria interna logger dati La lettura dei dati che non vengono gi trasme
4. PDC incl Contatto Reed PDC incl Modulo EDC pulse per MTKD N per tipo il contattore M 3 Installazione e o integrazione del modulo PDC in un contatore moduli PDC ZENNER sono stati progettati anzitut to per tutti i contatori dell acqua ZENNER attrezza bili con i generatori di impulsi versione N Fonda mentalmente un PDC pu essere collegato a tutti i contatori con un ingresso ad impulsi adeguato 3 1 Collegamento integrazione del modulo PDC IP68 con estremit cavo aperta al con tatore con uscita di impulsi esistente Collegare il cavo del generatore di impulsi con il cavo del PDC utilizzando un connettore cavi e possibilmente prestando attenzione alla polarit corretta bianco Reed contatto Yo Ingresso impulsi Non per comando Push Pull Solo per comando Open Collector NPN bianco o Open Drain canale N l LI Lo se Lunghezza minima impulsi 20 ms Open Collector marrone GND Frequenza massima impulsi 25 Hz 3 2 Collegamento integrazione del modulo PDC IP54 con il trasmettitore contatti di un contatore qualsiasi Collegare il cavo del generatore di impulsi del contatore con i rispettivi morsetti sulla scheda di circuito PDC Illustrazione Schema di collegamento PDC _ 00000090 Ol OO INPUT A GND INPUT B 3 3 Montaggio integrazione del modulo PDC con generatore di impulsi installato in produzione ZENNER nei rispettivi contatori dell acqua ZENNER Si prega di far riferimen
5. the flow value is never zero then this indicates a leak The PDC module sets corre sponding bits Is the flow rate remains zero during one quar ter of an hour before reaching 96 quarters of an hour with no flow the algorithm restarts If 96 quarters of an hour were running with flow leakage remains set until during 8 quarters of an hour in a row the flow remains zero The event memory stores the date and time of the event Meter stop detection blockade If no meter progress will be detected by the PDC module over a period of 4 weeks meter stop blockade is detected The blockade deemed to be revoked if a meter reading difference of gt 10 liters occurs in a quar ter of an hour Meter oversized detection Meter is oversized when the flow never exceed 0 1 Q3 10 of Q3 This is averaged over a 15 minute period It is counted how many times the flow rate of 10 of Q3 is not achieved If the flow rate is not reached after 30 days meter oversized is detected If once a flow rate of gt 10 from Q3 averaged is reached by a quarter of an hour the detection is permanently disabled and the status meter oversized deleted The algorithm can be restart ed via optical head 14 Deise 772 Francais Ital Undersized detection counter If the flow rate is continuously higher as Q3 permanent flow over a 6 hour period this indicates an undersizing of the meter and the message meter undersized will be detected
6. 24 h 96 Vier telstundenwerte der Wert des Durchflusses nie Null ist dann deutet dies auf eine Leckage hin Das PDC Modul setzt entsprechende Bits Ist der Durchfluss w hrend einer Viertelstunde Null vor Erreichen von 96 Viertelstunden ohne Dur chfluss startet der Algorithmus neu Wurden 96 Viertelstunden mit Durchfluss er reicht gilt Leckage solange als gesetzt bis 8 Viertelstunden in Folge der Durchfluss Null war Im Ereignisspeicher werden Datum und Uhrzeit des Ereignisses gespeichert Erkennung Z hlerstillstand Blockade Wenn ber einen Zeitraum von 4 Wochen kein Z hlerfortschritt vom PDC Modul erkannt wird wird Z hlerstillstand Blockade erkannt Die Blockade gilt als aufgehoben wenn in einer Viertelstunde eine Z hlerstandsdifferenz von gt 10 Liter auftritt Erkennung Z hler berdimensioniert Z hler ist berdimensioniert wenn der Durch fluss nie gr er ist als 0 1 Q3 10 von Q3 Dabei wird ber 15 Minuten gemittelt Es wird gez hlt wie oft der Durchfluss von 10 von Q3 nicht erreicht wird Wird der Durchfluss nach 30 Tagen nicht erreicht wird Z hler berdimensio niert erkannt Wird einmalig ein Durchfluss von gt 10 von Q3 gemittelt ber eine Viertelstunde erreicht wird die Erkennung dauerhaft deaktiviert und der Sta tus Z hler berdimensioniert wieder gel scht Der Algorithmus kann per Optokopf wieder neu gestartet werden Erkennung Z hler unterdimensioniert Wenn
7. Slide PDC over the wall bracket to the PDC clicks Dismounting of the PDC from the wall bracket Use screw driver or similar tool to push the upper strap of the wall bracket backwards and then pull the PDC downwards Data content wM Bus M Bus The PDC module can be delivered with various data telegram Telegram content Current value Current date Due Date value Previous month value Further 11 monthly values Status information 1 Status information 2 Type Type Type A B C LE x x x x x x x x x x x x x x x x x x Data telegram according OMS Spec typical transmission interval type A 40 sec Type B 40 sec wM bus manufacturer specific telegram typical transmission interval 20 sec 12 5 Radio modules The PDC wireless M Bus radio modules are avail able in T standard optionally and on request in S or C mode Various data telegrams are available The module operate unidirectional and usually send every 20 40 seconds Special versions are available on request and in certain quantities Specifications PDC radio Transmission mode wire less M Bus unidirectional T1 default optionally 1 C1 AES 128 OMS device Encryption specific optionally customer specific Transmission mode date due date monthly Contents of the value historical monthly package value values Status information Transmission interval typically 20 40s Transmission power 25 mW
8. de piles non amovibles et non rechargeables Lithium Ces piles contiennent des substances pouvant nuire a l environnement et la sant humaine si leur limination n est pas effectu e de mani re professionnelle Pour r duire la quantit de d chets ainsi que les polluants difficilement d gradables issus d appa reils lectriques et lectroniques les appareils usag s doivent tre recycl s en priorit resp les mat riaux qui les composent doivent tre r utili s s ou valoris s sous une autre forme Ceci n est possible que si les appareils usag s qui contiennent des piles ou autres composants sont limin s de fa on professionnelle Pour tous renseignements veuillez vous adresser aux autorit s communales charg es du recy clage ZENNER peut galement liminer votre appareil usag Les points de reprise de vos appareils usag s sont disponibles par exemple la mairie locale aupr s des d chetteries locales Compteurs Zenner S A R L 7 rue Gustave Eiffel F 87410 Le Palais sur Vienne T l phone 05 55 38 37 O9 T l copie 05 55 38 37 15 Courriel zenner france zenner com Internet www compteurs zenner fr 22 Attention Les appareils usages ne doivent pas tre jet s avec les ordures m nag res Vous contribuez ainsi la protection les res sources naturelles et la promotion du recy clage durable des mat riaux Pour toutes questions contactez info zenner com Vous trouverez des
9. der Durchfluss ber eine Dauer von 6 Stunden ununterbrochen gr er als Q3 Dauer durchfluss ist deutet dies auf eine Unterdi mensionierung des Z hlers hin und es wird Z hler unterdimensioniert erkannt Dabei wird ber 15 Minuten gemittelt Im Ereignisspeicher werden Datum und Uhrzeit des Ereignisses gespeichert Erkennung Rohrbruch Bei PDC M Bus Rohbruch wird erkannt wenn der Durchfluss w hrend einer zusammenh n genden Periode von 30 Minuten einen gegebe nen Wert gt 30 von Q3 berstiegen hat Dabei wird ber 15 Minuten gemittelt Im Ereignisspeicher werden Datum und Uhrzeit des Ereignisses gespeichert 10 Entsorgung Das Ger t enth lt eine nicht entnehmbare und nicht aufladbare Lithium Batterie Die Batterien enthalten Stoffe die bei nicht fach gerechter Entsorgung der Umwelt schaden und die menschliche Gesundheit gef hrden k n nen Um die Abfallmengen zu reduzieren sowie nicht vermeidbare Schadstoffe aus Elektro und Elektronikger ten in Abf llen zu reduzieren sol len Altger te vorrangig wiederverwendet oder die Abf lle einer stofflichen oder anderen Form der Verwertung zugef hrt werden Dies ist nur m glich wenn Altger te die Batterien oder sonstige Zubeh rteile des Produktes wieder dem Hersteller zur ckgef hrt werden Unsere Gesch ftsprozesse sehen in der Regel vor dass wir bzw die von uns eingesetzten Fa chfirmen Altger te inklusive Batterien und sons tigem Zub
10. emisi n Potencia de emisi n M Bus inalambrico unidireccional T1 est ndar opcional S1 C1 AES 128 conforme a OMS especifica de aparato especifico de fabrica o sin codificaci n opcionalmente valor actual fecha de lectura especificada valor del mes actual valores mensuales hist ricos Informaciones de estado tipico 20 405 25 mW 33 6 M dulos M Bus EI PDC como m dulo de M Bus sirve para la in tegraci n de contadores de agua en redes de M Bus conectadas por cables Mediante m dulos de M Bus de PDC conectados a contadores de agua por impulsos es posible de este modo una lectura de contadores de agua a traves del bus Datos t cnicos del M Bus PDC Numeros de hilos de cable 2 Longitud del cable Tom se corresponde con La compatibilidad la directiva europea electromagn tica 89 336 CEE Kabelbelegung wei M Bus 1 braun M Bus 2 Gr fico Esquema de conexi n PDC M Bus ENTRADA A TIERRA ENTRADA B TIERRA 34 Deutsch English Francais Italia 7 Clave AES Los m dulos envian sus paquetes de datos solo codificadas AES 128 especificos de aparato conforme a OMS A fin de permitir la recepci n de los paquetes de datos y su posterior procesa miento se debe disponer la clave AES en el re ceptor correspondiente Por lo general ZENNER proporciona las claves AES para los aparatos mediante una nota de entrega electr nica y en el futuro tambi n mediante de
11. energy meter with pulse output in walk by or drive by system m Radio transmission of the readings to mobile or stationary receivers m Remote reading via M Bus systems By the means ofthe PDC module conventional meters with pulse output can be integrated in radio or M Bus systems in an easy and cost efficient way For this purpose the pulse output of the meter is to be connected with the battery powered PDC module For ZENNER water meter retrofittable with pulser ZENNER provides corresponding PDC modules with ex works installed pulse output The PDC module is available in following versions m RADIO wireless M Bus module according to OMS standard 868 MHz EN 13757 4 M Bus wired M Bus module EN 13757 3 Both models are available as versions filled with resin and protected from moisture entering The PDC modules are each powered by a lithium cell that depending on the PDC version and on number of input channels and the transmission interval has a lifespan of up to 15 years Scope of delivery PDC module with mounting kit and installation instructions possibly with Pulse Generator con nected ex works for specific ZENNER water meter Deutsch L17121 Francais 2 General Specifications General Specifications Battery Voltage Pulse duration Pulse pause Battery life Ambient temperature Protection class Requirements for pulse encoder incl connection cable Fig 1 PDC incl Reedswitch for
12. informations mises a jour sur ce produit ainsi que notre manuel de montage sur notre site www compteurs zenner fr Technische nderungen vorbehalten F r etwaige Irrt mer und Druckfehler bernehmen wir keine Haftung SAP150691 150805_DE EN FR ITA_ES 1 Breve descrizione Trasmissione di impulsi ad un convertitore M Bus con o senza fili Il modulo PDC Pulse Data Capture consente di integrare i contatori con uscita ad impulsi nei siste mi radio o nei sistemi di misurazione intelligente Condizioni di utilizzo tipiche Lettura radio dei contatori dell acqua con usci ta ad impulsi o dei contatori di altre tipologie di energia con uscita ad impulsi nei sistemi Walk by o Drive by m Trasmissione radio dei dati rilevati dal conta tore a ricevitori mobili o fissi m Lettura remota dei contatori tramite impianti M Bus Il modulo PDC consente di integrare i contatori convenzionali con uscita ad impulsi negli impianti radio o M Bus in modo facile ed economico A tale scopo l uscita ad impulsi del contatore deve essere collegata al modulo PDC a batteria Per i contatori dell acqua attrezzabili con un genera tore di impulsi ZENNER fornisce appositi moduli PDC con generatore di impulsi installato in fase di produzione Il modulo PDC disponibile nelle seguenti versioni m RADIO modulo M Bus wireless conforme allo standard OMS 868 MHz EN 13757 4 m M Bus modulo M Bus con fili EN 13757 3 Entrambi i modelli sono disp
13. pulse width 20 ms Max pulse frequency 25 Hz Fig Connection sketch PDC 01208000 Ol OO INPUT A GND INPUT B 3 3 Mounting retrofit PDC with ex works installed ZENNER pulser to corresponding ZR water meters Please refer to the relevant installation instruc tions of the pulser and take the PDC as de scribed in section 3 4 in operation 3 4 Commissioning PDC The commissioning is performed via the optical interface The parameters to be programmed using a laptop with the Global ZENNER meters Manager GMM software Configuration Manager license the universal interface MinoConnectRadio with Bluetooth interface and the associated special ZENNER infrared optical head IrCombiHeaad Al ternatively the use of an Android handhelds with a MeterReaderLight license instead of a laptop is possible Configure at least m serial number of meter connected to the PDC module m Initial value present value of the register of the connected meter m Pulse value of the connected meter The respective transmission interval is preset Additional setting parameters m Reset logger values m Reset status bits manipulation error m AES key depending on the software license Activation takes place automatically when the PDC module has received more than 10 pulses from the meter 11 4 Wall mounting of PDC Install wall bracket with the en closed wall plugs and screws as shown below on a flat wall surface
14. sito www zenner com 29 Technische nderungen vorbehalten F r etwaige Irrt mer und Druckfehler bernehmen wir keine Haftung SAP150691 150805_DE EN FR ITA_ES 1 Descripci n abreviada Convertidor de impulsos a M Bus inal m brico o de impulsos a M Bus cableado El modulo PDC Pulse Data Capture sirve para la conexi n de contadores con salida de impulsos a sistemas de radio o sistemas Smart Metering Casos de aplicaci n tipicos m Lectura v a radio de contadores de agua con salida de impulsos o contadores de otros tipos de energ a con salida de impulsos lectura m vil Walk by o Drive by Transmisi n v a radio de datos del contador a receptores m viles o fijos m Lectura a distancia de contadores a trav s de instalaciones M Bus Con ayuda del m dulo PDC se pueden integrar de forma sencilla y econ mica contadores con vencionales con salida de impulsos en instalacio nes v a radio o M Bus Para ello la salida de impulsos del contador se conecta con el m dulo PDC el cual funciona con bater a Para los contadores ZENNER preequi pados posteriormente equipables con emisores de impulsos ZENNER ofrece el m dulo PDC co rrespondiente con el emisor de impulsos conec tado de f brica 30 Deutsch English Francais Italia El m dulo PDC se encuentra disponible en las siguientes versiones m RADIO m dulo M Bus inal mbrico wM bus conforme al est ndar OMS 868 MHz EN 13757 4 m M Bus m dul
15. ult rieur du PDC avec un g n rateur d impulsions ZENNER mont usine a un compteur d eau quipable ZEN NER correspondant Veuillez vous r f rer aux instructions d installa tion du g n rateur d impulsions et mettre le PDC en service comme d crit au paragraphe 3 4 3 4 Mise en service du PDC La mise en route se fait avec l aide d un interface optique Les param tres configurer sont pro gramm s au moyen d un PC portable avec le lo giciel licence Configuration Manager ZENNER GlobalMeterManager GMM l interface univer sel MinoConnectRadio avec interface Bluetooth et la t te optique associ e IrCombiHead de ZEN NER Alternativement Putilisation d un terminal portable sous Android avec une licence Meter ReaderLight la place d un PC portable est ga lement possible Doivent tre configur s au minimum m Numero de s rie du compteur connect au module PDC Valeur initiale Position initiale du compteur Valeur d impulsion du compteur connect Lintervalle de transmission respectif est pr con figur Autres param tres configurer R initialisation valeurs concentrateur R initialisation des bits d tat manipulation erreur m Cl AES d pendant de la licence du logiciel Lactivation se fait automatiquement lorsque le module PDC a r ceptionn plus de 10 impulsions en provenance du g n rateur 4 Montage du calculateur 9 Modules radio sur le mur Les modules PDC w
16. 10 litres par Y h appara t Reconnaissance compteur surdimensionn Le compteur est surdimensionn si le d bit n est jamais sup rieur a 0 1 Q3 10 de Q3 Une moyenne est effectu e au bout de 15 minutes Un comptage permettant de savoir combien de fois le d bit de 10 de Q3 n est pas atteint est effectu Si le d bit n est pas atteint apr s 30 jours le compteur est reconnu comme comp teur surdimensionn Si une seule fois un d bit gt 10 de Q3 en moyenne durant d heure est atteint la recon naissance est d sactiv e de fa on durable L algorithme peut tre red marr au moyen de la t te optique Reconnaissance compteur sous dimensionn Le compteur est sous dimensionn lorsque le d bit est sup rieur Q3 d bit permanent durant plus de 6 heures de fa on ininterrompue et est reconnu alors comme compteur sous dimensionne Une moyenne est effectu e sur une p riode de 15 minutes La date et l heure de l v nement sont enregis tr es dans le journal des donn es Reconnaissance rupture tuyauterie Concerne le module PDC M Bus L v nement Rupture tuyauterie est reconnu si le d bit at teint un chiffre pr indiqu gt 30 de Q3 durant une p riode ininterrompue de 30 minutes Une moyenne est effectu e sur 15 minutes La date et l heure de l v nement sont enregis tr es dans le journal des donn es 21 10 Elimination Attention Cet appareil est pourvu
17. 408 T l grammes de donn es conforme aux sp cifications OMS transmission Intervalle de transmission typique type A 40 sec Type B 40 sec Puissance de wM Bus t l gramme de donn es sp cifique au fabricant intervalle 25 mW de transmission typique 20 sec transmission 19 6 Modules M Bus Le module PDC dans sa version M Bus est destin a l int gration de compteurs d eau dans des r seaux M Bus cabl s Le raccordement de modules M Bus PDC avec des compteurs d eau mettant des impulsions permet la rel ve de ces compteurs via Bus Donn es techniques PDC M Bus Nombre de fils 2 Longueur de cable 1 5m se Correspond la directive Compatibilit Ge oie europ enne 89 3366 EWG Cablage Blanc M Bus 1 Brun M Bus 2 o 992000 Figure PFOA Sch ma de raccordement PDC M Bus INPUT A eu Bus a INPUT B M BUS 2 20 Deutsch English Italiano 7 Cl AES Les modules PDC envoient leurs stocks de don n es uniquement de mani re crypt e AES 128 sp cifique l appareil conforme OMS Pour per mettre la r ception et le traitement ult rieur des stocks de donn es il est indispensable de t l charger la cl AES dans le r cepteur ZENNER fournit les cl s AES pour les appareils en g n ral au moyen d un bon de livraison lectronique ou dans un fichier d termin avec le client 8 Lecture concentrateur de donn es Les modules PDC disposent d une m moire in terne
18. GREAT AIS LI EnergieTechnik PDC Pulse Data Capture Modul Pulse Data Capture Montage und Bedienungsanleitung Impuls zu wireless bzw wired M Bus Konverter EJ LA Installation and operating instructions Pulse to wireless or wired M Bus Converter BI Notice d installation et d utilisation WN Convertisseur d impulsions en protocole M Bus filaire ou sans fil D istruzioni per il montaggio e l utilizzo Trasmissione di impulsi ad un convertitore M Bus con o senza fili Manual de montaje y operaci n Convertidor de impulsos a M Bus inal mbrico o M Bus cableado Alles was z hlt 1 Kurzbeschreibung wireless bzw wired M Bus Konverter Das PDC Pulse Data Capture Modul dient zur Einbindung von Z hlern mit Impulsausgang in Funksysteme bzw Smart Metering Systeme Typische Anwendungsf lle m Funkauslesung von Wasserzahlern mit Impul sausgang oder Z hler anderer Energiearten mit Impulsausgang im Walk by oder Drive by Verfahren m Funk bertragung der Z hlerdaten an mobile oder station re Empf nger m Z hlerfernauslesung ber M Bus Anlagen Mit Hilfe des PDC Moduls lassen sich auf ein fache und kosteng nstige Weise konventionelle Z hler mit Impulsausgang in Funk oder M Bus Anlagen integrieren Dazu wird der Impulsausgang des Z hlers mit dem batteriebetriebenen PDC Modul verbunden F r mit Impulsgeber nachr stbare ZENNER Was serz hler bietet ZENNER entsprechende PDC Mo
19. MNK N 10 3 6V min 20 ms min 20 ms depending on the mode number of channels used wM Bus package type transmission frequency up to 15 years is possible 10 C 40 C 15 C 60 C temporarily Electronics filled with resin to avoid moisture entering max 300 Q or max max 0 3V ON max 1000pF OFF Data logger Annual Due date values max 16 max 192 plus max Monthly values 192 biweekly values Daily values max 96 Quarter hour values max 96 zum Fig 2 Fig 3 PDC incl Reedswitch for PDC incl EDC Pulse module MTKD N for meter type M 3 Installation respective retro fitting of the PDC to a meter The ZENNER PDC modules are designed primar ily for all water meters of ZENNER which can be retrofitted with a pulse generator model N Basi cally a PDC can be connected to any meter with suitable pulse output 3 1 Connection retrofitting of PDC IP68 with open cable end to meter with existing pulse output Connect the pulse output of the meter with the PDC cable Use a cable connector and possibly observe the correct polarity white mM Reed contact Log EM white pulse Open collector brown GND 3 2 Connection retrofitting PDC IP54 with pulse output of any meter Connect pulse output cable from the meter to the corresponding terminals on the PDC circuit board Pulse Input No push pull drive Only for npn or n channel Min
20. PDC incl contactos PDC incl EDC m dulo pulso Reed per MTKD N para el tipo de contador M 31 3 Instalaci n o montaje posterior del PDC en un contador preequipado Los m dulos PDC de ZENNER se han desarro llado principalmente para todos los contadores de agua ZENNER posteriormente equipables con emisor de impulsos modelo N Generalmente el PDC se puede conectar a todos los contadores con una salida de impulsos adecuada 3 1 Conexion montaje posterior del PDC IP68 con terminal de cable libre al contador con Salida de impulsos existente Conectar el cable del emisor de impulsos del con tador con el cable de conexi n del PDC utilizar para ello un conector de cables y dado el caso prestar atenci n a que la polaridad sea correcta Entrada de impulsos blanco iNo apto para control push pull contacto reed eno iSolo para control de colector abierto NPN blanco o drenaje abierto canal N impulso colector abierto Duraci n m nima de impulso 20 ms brown GND Frecuencia maxima de impulsos 25 Hz 3 2 Conexi n montaje posterior del PDC IP54 con el dispositivo de contacto corres pondiente del contador Conectar el cable del emisor de impulsos del contador con el borne de conexi n correspon diente de la placa del PDC Gr fico Esquema de conexi n PDC ENTRADA A TIERRA ENTRADA B TIERRA 32 Deutsch English Francais Italiano 3 3 Montaje montaje posterior del PDC co
21. S 868 MHz EN 13757 4 m M Bus module wired M Bus EN 13757 3 m Les deux mod les sont galement dispo nibles scell s et ainsi prot g s de l humidit entrante Ces modules PDC sont respectivement ali ment s par une batterie au lithium qui selon le mod le et le nombre de canaux d entr e et d intervalles de transmission a une dur e de vie pouvant aller jusqu a 15 ans Contenu de la livraison Module PDC avec kit et notice de montage pos sibilite de connecter un g n rateur d impulsions depart usine pour un compteur d eau specifique de ZENNER 2 Specifications generales Specifications generales Tension de la batterie Dur e de l impulsion Pause entre les impulsions Dur e de vie de la batterie Temp rature ambiante Classe de protection Exigences pour le g n rateur d impulsions y compris le c ble de connexion Figure 1 PDC incl Reedswitch for MNK N 3 6V min 20 ms min 20 ms varie en fonction du mode nombre de canaux utilis s type de t l gramme de donn es wM Bus fr quence de transmission possible jusqu 15 ans 10 C 40 C 15 C 60 C temporairement Electronique remplie de r sine pour viter que l humidit n entre max 300 Q ou max 0 3V ON max 1000pF OFF Concentrateur de donn es Valeurs date max 16 rep re annuelles max 192 plus max 192 Valeurs mensuelles valeurs semi mensuelles Valeurs journali
22. a superficie lo mas plana posible conforme a la siguien te ilustraci n Deslizar el PDC desde abajo sobre el soporte de pared hasta que el PDC encaje Desmontaje del PDC del so porte de pared Con un des tornillador u otra herramienta similar presionar hacia atras la pestafia del soporte de pa red que sobresale un poco del PDC montado y a continuaci n deslizar el PDC hacia abajo Contenido de datos wM Bus M Bus EI m dulo PDC esta disponible con diferentes telegramas de datos Contenidos de protocolo Valor actual Fecha actual Valor de fecha de lectura Monatswert Vormonat Valor del mes anterior Informaci n de estado 1 Informaci n de estado 2 tipo tipo tipo A B C x x x x x x x x x x x x x x x x x x Telegrama de datos en conformidad con OMS intervalo de emisi n tipico tipo A 40 s tipo B 30 s wM Bus telegrama especifico del fabricante intervalo de emisi n tipico 20 s 5 Modulos de radio Los m dulos de M Bus inalambricos PDC estan dis ponibles en el modo T estandar y de forma opcio nal a demanda en los modos S 0 C Hay disponibles variantes con diferentes telegramas de datos Los m dulos funcionan de forma unidireccional y suelen emitir cada 20 40 segundos Hay modelos especiales sobre pedido y con una cantidad garanti zada correspondientemente Datos t cnicos PDC radio modos de transmisi n Codificaci n Contenido del paquete Intervalo de
23. b 2 Abb 3 PDC inkl Reedkontakt PDC inkl Reedkontakt PDC inkl EDC Pulsemodule f r MNK N f r MTKD N f r Z hlertyp M 3 Installation bzw Nachr stung des PDC an einen Z hler Die ZENNER PDC Module wurden in erster Linie entwickelt f r alle mit Impulsgeber nachr stba ren ZENNER Wasserz hler Ausf hrung N Grunds tzlich kann ein PDC an alle Z hler mit geeignetem Impulsausgang angeschlossen wer den 3 1 Anschluss Nachr stung PDC IP68 mit offenem Kabelende an Z hler mit vorhande nem Impulsausgang Impulsgeberkabel vom Z hler mit dem Anschlusskabel des PDC verbinden dazu Ka belverbinder verwenden und ggf auf korrekte Polarit t achten Pulseingang Wei Nicht f r Push Pull Ansteuerung Reed Kontakt spas Nur f r Open Collector NPN oder Wei Open Drain N Kanal Ansteuerung pulse Open Collector Minimale Pulsl nge 20 ms Maximale Pulsfrequenz 25 Hz Braun GND 3 2 Anschluss Nachr stung PDC IP54 mit dem jeweiligen Kontaktgeber des Z hlers Impulsgeberkabel vom Z hler mit den entsprechenden Anschlussklemmen der PDC Platine verbinden Abb Anschlussschema PDC INPUT A GND n INPUT B GND ES 3 3 Montage Nachr stung PDC mit ab Werk angeschlossenem ZENNER Impul sgeber an entsprechende nachr stbare ZENNER Wasserz hler Bitte die jeweilige Montageanleitung des Impuls gebers beachten und das PDC gem Beschrei bung unter Punkt 3 4 in Betrieb nehme
24. ci n de contador sobredimensionado El contador estar sobredimensionado cuando el caudal no sea nunca mayor que 0 1 Q3 10 de Q3 Se determina a lo largo de 15 minutos Se cuen ta con qu frecuencia no se alcanza el caudal del 10 de Q3 Si no se alcanza el caudal trans curridos 30 d as se detecta contador sobredi mensionado Si se alcanza una vez un caudal gt 10 de Q3 determinado a lo largo de un cuarto de hora la detecci n se desactiva de forma autom tica y el estado contador sobredimensionado se vuel ve a borrar El algoritmo se puede reiniciar me diante el cabezal ptico Detecci n de contador subdimensionado Si el caudal es mayor que Q3 de forma ininte rrumpida durante seis horas caudal permanen te esto indica un subdimensionado del conta dor y se detecta contador subdimensionado Se determina a lo largo de 15 minutos En la memoria de incidencias se guardan la fe Cha y la hora de la incidencia Detecci n de rotura de tuber as En el M Bus del PDC Se detecta rotura de tuber a si el caudal supera un valor indicado gt 30 de Q3 durante un per odo continuado de 30 minutos Se determina a lo largo de 15 minutos En la memoria de incidencias se guardan la fecha y la hora de la incidencia 35 10 Eliminaci n Atenci n Este equipo contiene piezas no susti tuibles y baterias no recargables Litio compro bar dependiendo del producto Estas baterias contienen sustan
25. cias que pue den da ar el medioambiente y la salud si no se eliminan correctamente Para reducir la cantidad de residuos de equipos electr nicos y el ctricos todos los materiales viejos deben ser reutilizados si es posible o ser reciclados Esto es s lo posible con equipos antiguos que contienen bater as u otros accesorios Por lo tanto por favor contacte con el departamento de eliminaci n de residuos de su zona o localidad Alternativamente es posible la eliminaci n a tra v s de ZENNER La autoridad local o provincial o la empresa encargada de la eliminaci n de residuos pueden informarle de los puntos m s cercanos para la recogida de los mismos ZENNER International GmbH amp Co KG R merstadt 6 D 66121 Saarbr cken Telefono 49 681 99 676 30 Fax 49 681 99 676 3100 E Mail info zenner com Internet www zenner com cc ro o SS Atenci n No eliminar los equipos con los residuos dom sticos De esta manera colaboramos en la protecci n de los recursos naturales y promovemos el reci claje de los materiales Para cualquier duda puede contactar www zenner es Encontrar las informaciones m s recientes sobre este producto y la versi n m s actual de este manual en Internet en www zenner es Technische nderungen vorbehalten F r etwaige Irrt mer und Druckfehler bernehmen wir keine Haftung SAP150691 N uy E a w u Ww a 12 3S B
26. concentrateur de donn es La lecture des donn es qui ne sont pas d j transmises dans les t l grammes de donn es pr c dentes se fait au moyen de l interface optique utilisant MinoCon nectRadio la t te optique de ZR IrCombiHead et le logiciel appropri Concentrateur de donn es Voir point 2 Tableau des sp cifications g n rales 9 Fonctions intelligentes Autodiagnostic Le module dispose d une fonction de surveil lance de la batterie integree Reconnaissance fuites Lorsque sur une p riode de 24h 96 valeurs enregistr es par d heures la valeur du debit nest jamais quivalente a z ro cela signifie la pr sence d une fuite Le module PDC definit des bits en cons quence Si le d bit quivaut a z ro durant Y d heure avant que les valeurs enregistr es par Y d heure n aient atteint le chiffre 96 sans debit l algorithme red marre nouveau Si les valeurs enregistr es par Y d heures at teignent 96 avec d bit une fuite est reconnue tant que durant 8 d heures de suite le d bit n a pas atteint le chiffre O La date et l heure de l v nement sont enregistr es dans le journal des v nements Reconnaissance Arr t du compteur blocage Si aucune avance du compteur n est reconnue par le module PDC durant une p riode de 4 semaines un arr t du compteur blocage est d tect Le blocage du compteur est consid r comme annule si une difference du compteur de plus de
27. dule mit ab Werk angeschlossenem Impulsge ber an TEEN English Francais Italia Das PDC Modul steht in folgenden Modell varianten zur Verf gung m FUNK wireless M Bus Modul gem OMS Standard 868 MHz EN 13757 4 m M Bus wired M Bus Modul EN 13757 3 Beide Modellvarianten sind auch vergossen und somit gesch tzt gegen Eindringen von Feuchtigkeit erh ltlich Die PDC Module werden jeweils von einer Li thiumzelle versorgt die je nach PDC Variante abh ngig von Anzahl der Eingangskan le und dem Sendeintervall eine Lebensdauer von bis zu 15 Jahren hat Lieferumfang PDC Modul mit Befestigungsset und Mon tageanleitung ggf mit bereits ab Werk an geschlossenem Impulsgeber f r bestimmte ZENNER Wasserz hler 2 Allgemeine technische Daten Allgemeine technische Daten Batteriespannung 3 6V Pulsdauer min 20 ms Pulspause min 20 ms Batterielebensdauer abhangig von der Betriebsart Anzahl genutzter Kan le wM Bus Pakettyp Sendeh ufigkeit bis zu 15 Jahre m glich Umgebungstemperatur 10 C 40 C 15 C 60 C vor bergehend Schutzart Elektronik vergossen gegen Eindringen von Feuchtigkeit max 300 Q bzw max 0 3V EIN max 1000pF AUS Anforderungen an Pulsgeber incl Anschlussleitung Datenlogger Jahrliche Stichtagswerte max 16 max 192 zzgl max Monatwene 192 Halbmonatswerte Tageswerte max 96 Viertelstundenwerte max 96 ZENKER Abb 1 Ab
28. ed elettronici i rifiuti degli apparecchi andreb bero riutilizzati o i rispettivi materiali andrebbero riciclati Ci possibile solo riportando al produt tore i rifiuti degli apparecchi contenenti batterie o altri componenti del prodotto nostri processi commerciali prevedono gene ralmente che la nostra azienda o eventuali ditte specializzate da noi incaricate ritirino e smalti scano opportunamente i rifiuti degli apparecchi comprese batterie e accessori vari una volta so stituiti e o arrivati alla fine della loro vita Qualora rispetto a quanto indicato non sia stata stabilita nessuna altra regola contrattuale in alternativa i rifiuti degli apparecchi e i rispettivi accessori si possono consegnare gratuitamente anche pres so la nostra sede in Talstra e 2 09619 Mulda Zenner provvede in ogni caso a verificare che lo smaltimento avvenga in maniera consona ZENNER Srl Societ Unipersonale Via XXV Aprile 8 1 40016 San Giorgio di Piano BO Telefono 39 051 890 22 00 Fax 39 051 665 03 10 E Mail info zenneritalia it Internet www zenneritalia it Attenzione Gli apparecchi non possono essere dismessi nei rifiuti comunali rifiuti domestici In questo modo si contribuisce alla protezione del le risorse naturali e al riutilizzo dei prodotti usati Per ulteriori domande contattare info zenner com Le informazioni pi recenti su questo prodotto e la versione aggiornata di questo manuale sono disponibili in Internet al
29. eh r nach deren Austausch bzw Ende der Nutzungsdauer wieder mitnehmen und fach gerecht entsorgen Sofern diesbez glich keine andere vertragliche Regelung getroffen wurde k nnen alternativ die Altger te und Zubeh r auch bei unserer Betriebsst tte in 09619 Mulda Talstra e 2 kostenlos abgegeben werden Zen ner stellt in jedem Fall die fachgerechte Entsor gung sicher ZENNER International GmbH amp Co KG R merstadt 6 D 66121 Saarbr cken Telefon 49 681 99 676 30 Telefax 49 681 99 676 3100 E Mail info zenner com Internet www zenner com 8 META Englishes Achtung Die Ger te d rfen nicht ber die kommunalen Abfalltonnen Hausm ll entsorgt werden Sie helfen dadurch die nat rlichen Ressourcen zu sch tzen und die nachhaltige Wiederverwer tung von stofflichen Ressourcen zu f rdern A Fragen richten Sie bitte an info zenner com Die neuesten Informationen zu diesem Produkt und die aktuellste Version dieser Anleitung finden Sie im Internet unter www zenner de Technische nderungen vorbehalten F r etwaige Irrt mer und Druckfehler bernehmen wir keine Haftung SAP150691 150805_DE EN FR ITA_ES 1 Short Description Pulse to wireless or wired M Bus Converter The PDC Pulse Data Capture module is used for the integration of meters with pulse output in radio systems or smart metering systems Typical application m Wireless remote read out of water meters with pulse output or other types of
30. ireless M Bus radio sont dispo Installer l adaptateur de mon nibles en T standard en option et sur demande en tage avec les chevilles et les mode S ou C vis comme indiqu ci dessous Diff rents t l grammes de donn es sont dispo sur une surface murale plane nibles Le module fonctionne de mani re unidirec Faire coulisser le PDC par en tionnelle et envoie des donn es en r gle g n rale bas sur l adaptateur jusqu ce toutes les 20 40 secondes Des versions sp ciales que le PDC s enclenche sont disponibles sur demande et dans certaines quantit s D montage du PDC de l adap tateur mural Avec un tour nevis ou un outil similaire pousser la languette situ e l g rement au dessus du PDC mont en arri re et faire glisser le PDC ensuite vers le bas T l grammes de donn es wM Bus M Bus Le module PDC est livrable avec des t l grammes de donn es diverses State de donn es ne nr kr Sp cifications PDC radio wireless M Bus Valeur actuelle x x x Mode de unidirectionnel T1 transmission par d faut Date actuelle x x en option S1 C1 Valeur date rep re x x x Cryptage AES 125 OMS sp cifique l appareil Maleuramois x x x date date ch ance aleur mensuell 11 valeurs mensuelles x Contenu des stocks ve ur ensuelle supplementaires historique des valeurs de donness mensuelles Informations Information d tat 1 x x x 2 d tat Information d tat 2 x x x Intervalle d RES typique 20
31. n 3 4 Inbetriebnahme PDC Die Inbetriebnahme erfolgt ber die optische Schnittstelle Die einzustellenden Parameter werden mittels Laptop mit der ZENNER Global MeterManager GMM Software Configuration Manager Lizenz dem Universalinterface Mino ConnectRadio mit Bluetooth Schnittstelle und dem zugeh rigen speziellen ZENNER Infrarot Optokopf IrCombiHead programmiert Alternativ ist auch der Einsatz eines Android Handhelds mit einer MeterReaderLight Lizenz anstelle eines Laptops m glich Zu konfigurieren ist mindestens m Z hlernummer des an das PDC angeschlossenen Z hlers m Anfangsz hlerstand aktueller Stand des Rollenz hlwerks des angeschlossenen Z hlers m Impulswertigkeit des angeschlossenen Z hlers Das jeweilige Sendeintervall ist voreingestellt Weitere einstellbare Parameter m R cksetzung Loggerwerte m R cksetzung Statusbits Manipulation Fehler m AES Key abh ngig von der Softwarelizenz Die Aktivierung erfolgt automatisch sobald das PDC Modul mehr als 10 Impulse vom Geber empfangen hat 4 Wandmontage PDC Wandhalter mittels beiliegen der D bel und Schrauben gem nachfolgender Abbil dung auf eine m glichst ebene Wandfl che montieren PDC von unten auf den Wandhalter aufschieben bis das PDC ein rastet Demontage des PDC vom Wandhalter Mit einem Schraubendreher oder hn lichem Werkzeug die obere etwas ber das montierte PDC herausstehende Lasche des Wandhalters nach hi
32. n emisor de impulsos ZENNER conectado de f bri ca a contadores de agua ZENNER preequipados Por favor tener en cuenta el manual de monta je del emisor de impulsos y poner en servicio el PDC conforme a la descripci n que aparece en el punto 3 4 3 4 Puesta en servicio del PDC La puesta en servicio se realiza a traves de la interfaz ptica Los par metros se programan mediante el or denador port til con el software de ZENNER GlobalMeterManager GMM licencia Configura tionManager la interfaz universal MinoConnec tRadio con interfaz Bluetooth y el correspondien te cabezal ptico infrarrojo especial IrCombiHead de ZENNER Como alternativa tambi n es posi ble utilizar un terminal port til Android con una licencia MeterReaderLight en lugar de un port til Se debe configurar como m nimo m N mero del contador conectado al PDC m Estado inicial del contador lectura actual de la relojer a de rodillos del contador conectado m Valor de impulsos del contador conectado El intervalo de env o correspondiente est preajustado Otros par metros ajustables m Restablecimiento del datalogger m Restablecimiento de bits de estado manipulaci n error m Clave AES dependiente de la licencia de software La activaci n se realiza autom ticamente en cuanto el m dulo PDC ha recibido m s de 10 impulsos del emisor 4 Montaje en pared del PDC Montar el soporte de pared mediante los tacos y tornillos en un
33. nten dr c ken und danach das PDC nach unten abziehen Datentelegramminhalte wM Bus M Bus Das PDC Modul ist mit unterschiedlichen Daten telegrammen lieferbar Datentelegramm Aktueller Wert Aktuelles Datum Stichtagswert Monatswert Vormonat Weitere 11 Monatswerte Statusinformation 1 Statusinformation 2 Typ Typ Typ A B C x x x x x x x x x x x x x x x x x x Datentelegramm OMS konform Sendeintervall Typ A typisch 40 Sek Typ B typisch 40 Sek wM Bus herstellerspezifisches Telegramm Sendeintervall typisch 20 Sek 5 Funkmodule Die PDC wireless M Bus Funkmodule sind im T Standard optional und auf Anfrage im S oder C Mode erh ltlich Es stehen Varianten mit unterschiedlichen Datente legrammen zur Verf gung Die Module funktionieren unidirektional und senden in der Regel alle 20 40 Sekunden Sonderaus f hrungen sind auf Anfrage bei entsprechender Abnahmemenge m glich Technische Daten PDC Funk bertragungsmodi Verschl sselung Datentelegramm inhalt Sendeintervall Sendeleistung wireless M Bus unidirektional T1 Standard optional S1 C1 AES 128 nach OMS ger tespezifisch optional kundenspezifisch aktueller Wert Stichtag aktueller Monatswert historische Monatswerte Statusinformationen typisch 20 40s 25 mW 6 M Bus Module Das PDC als M Bus Modul dient zur Integration von Wasserz hlern in drahtgebundene M Bus Netze Mit
34. o M Bus cableado EN 13757 3 Ambas variantes est n disponibles en versi n herm ticamante sellada y por ello protegida contra la entrada de humedad Los m dulos PDC se alimentan con una bater a de litio que en funci n de la variante de PDC dependiente del n mero de canales de entrada y del intervalo de emisi n ofrece una vida til de hasta 15 a os Conjunto de suministro M dulo PDC con juego de fijaci n e instruccio nes de montaje dado el caso con emisor de im pulsos conectado de f brica para determinados contadores ZENNER 2 Datos t cnicos generales Datos t cnicos generales Tension de bateria Duraci n de impulso Pausa entre impulsos Vida til de la bater a Temperatura ambiente Tipo de protecci n Requerimientos del emisor de impulsos incl l nea de conexi n Gr fico 1 PDC incl contactos Reed per MNK N 3 6V min 20 ms min 20 ms dependiendo del modo de funcionamiento n mero de canales utilizados tipo de paquete wM Bus frecuencia de emisi n hasta 15 a os h 10 C 40 C 15 C 60 C temporalmente Electr nica hermeticmente sellada contra la entrada de humedad max 300 Q o max 0 3V entrada max 1000pF salida Datalogger Valores de fecha de lectura max 16 anuales max 192 mas max 192 Valores mensuales p valores quincenales Valores diarios m x 96 Valores de cuarto de hora m x 96 Gr fico 2 Gr fico 3
35. o pari al 10 del Q3 non viene raggiunto Se il flusso stabilito non viene raggiunto entro 30 giorni si rileva una condizione di contatore so vradimensionato 28 Se si raggiunge un flusso gt 10 di Q3 per una volta in un quarto d ora il rilevamento viene disa bilitato in maniera permanente e la condizione di contatore sovradimensionato eliminata L algo ritmo pu essere riavviato tramite il lettore ottico Rilevamento contatore sottodimensionato Se il flusso risulta maggiore di Q3 flusso con tinuo ininterrottamente per 6 ore significa che si verificato un sottodimensionamento del contatore e viene riconosciuta la condizione di contatore sottodimensionato Il calcolo viene eseguito rispetto ad un intervallo di 15 minuti La memoria eventi registra data e ora dell evento Rilevamento rottura tubi Per un modulo PDC M Bus La rottura del tubo viene rilevata nel caso in cui il flusso superi un valore specifico per 30 minuti gt 30 di Q3 Il calcolo viene eseguito su un intervallo di 15 mi nuti La memoria eventi registra data e ora dell evento 10 Smaltimento Attenzione questo apparecchio contiene una batteria non ricaricabile al litio che non pu es sere rimossa Le batterie contengono sostanze che potrebbe ro danneggiare l ambiente e la salute umana se non smaltite in modo adeguato Per ridurre la quantita di rifiuti e la presenza di prodotti nocivi inevitabili negli strumenti elettrici
36. onibili anche nella versione con resina riempitiva per pro teggere dall umidit I moduli PDC vengono alimentati rispettivamen te da una cella al litio che in base alla versione del modulo PDC secondo il numero dei canali di ingresso e dell intervallo di trasmissione pu durare fino a 15 anni Contenuto della confezione Modulo PDC con kit di montaggio e istruzioni per il montaggio possibilmente collegato in pro duzione con un generatore di impulsi per alcuni specifici contatori dell acqua ZENNER 23 2 Specifiche generali Specifiche generali Tensione della batteria Durata impulsi Pausa tra impulsi Durata della batteria Temperatura ambiente Classe di protezione Requisiti per il generatore di impulsi tra cui cavo di collegamento Illustrazione 1 PDC incl contatto Reed per MNK N 24 3 6V min 20 ms min 20 ms in base alla modalit di funzionamento numero di canali utilizzati tipo di pacchetto wM Bus frequenza di trasmissione fino a 15 anni 10 C 40 C 15 C 60 C temporaneamente Resina riempitiva per impedire all umidit di penetrare nei componenti elettronici max 300 Q e o max 0 3V ON max 1000pF OFF Logger dati Valori annuali alla data di scadenza max 16 max 192 pi max 192 Valori mensili Re valori bisettimanali Valori giornalieri max 96 Valori ogni quarto d ora max 96 ZENER Illustrazione 2 Illustrazione 3
37. pporto parete fino a farlo incastrare Smontaggio del modulo PDC dal supporto parete con un cacciavite o un utensile simile premere all indietro la linguetta superiore leggermente spor gente dal modulo PDC monta to e quindi tirare verso il basso il modulo PDC Contenuti dati wM Bus M Bus Il modulo PDC disponibile con diversi telegrammi dati Contenuto tipo tipo tipo telegramma A B Gus Valore attuale x x x Data attuale x x Valore data di scadenza x x x Valore mese precedente x x x Altri 11 valori mensili x Informazione di stato 1 x x x Informazione di stato 2 x x x Telegramma dati secondo le specifiche OMS intervallo di trasmissione tipico di tipo A 40 sec tipo B 40 sec wM Bus telegramma specifico del produttore intervallo di trasmissione tipico 20 sec 26 5 Moduli radio I moduli radio PDC wireless M Bus sono disponibili nella modalita T standard e a scelta e a richiesta in modalit S o C Sono disponibili svariate varianti con telegrammi dati diversi I moduli funzionano in modalit unidirezionale e ge neralmente trasmettono ogni 20 40 secondi Even tuali versioni speciali sono disponibili su richiesta nel rispetto di determinati quantitativi minimi Specifiche PDC radio Modalit di trasmissione Crittografia Contenuti del pacchetto dati attuale Intervallo di trasmissione tipico Potenza di trasmissione M Bus wireless unidirezionale T1 standard
38. res max 96 Valeurs enregistr es par heure max 98 Figure 2 Figure 3 PDC incl Reedswitch for PDC incl EDC Pulse module MTKD N for meter type M 17 mn Deutsch English Italiano Espa a 3 Installation resp mise en place ult rieure d un PDC sur un compteur Notre PDC est destin en premier lieu tous les compteurs d eau qui peuvent tre quip s ult rieurement d un g n rateur d impulsions mod le N A la base un PDC peut tre connect chaque compteur muni d une sortie impulsionnelle correspondante 3 1 Connection ult rieure d un PDC IP68 avec bout de ligne ouvert sur un compteur avec sortie impulsionnelle existante Connecter la sortie impulsionnelle du compteur avec le c ble du PDC Utiliser un connecteur pour c ble et si possible respecter la polarit correcte Entr e impulsionnelle blanc Pas de commande push pull Contact Reed ern Uniquement pour commande par blanc collecteur ouvert NPN ou Open Drain Le Collecteur ouvert Longueur d impulsion 20 ms Fr quence d impulsion maximale 25 Hz marron GND 3 2 Connection ult rieure d un PDC IP54 avec le contacteur du compteur Raccorder le cable du g n rateur d impulsions du compteur avec les bornes de raccordement du circuit imprim Figure Sch ma de raccordement PDC 0409090 ON OO INPUT A GND a INPUT B GND SS 18 3 3 Montage
39. scarga o a trav s de un archivo determinado especificamente por el cliente 8 Lectura del registrador de datos Los m dulos PDC disponen de una memoria interna datalogger La lectura de datos que no se transfieran ya en los telegramas de datos se realiza a trav s de la interfaz 6ptica mediante MinoConnect el cabezal ptico IrCombiHead de ZENNER y el software correspondiente Datenlogger v ase punto 2 Tabla Datos t cnicos generales 9 Funciones de Smart Meter Autocomprobaci n El m dulo dispone de una comprobaci n de estado de la bateria integrada Detecci n de fugas Si el valor de caudal no es nunca cero duran te un periodo de 24 h 96 valores de cuarto de hora esto sera se al de una fuga El m dulo PDC establece los bits correspondientes Si el caudal es cero durante un cuarto de hora antes de alcanzar 96 cuartos de hora sin cau dal el algoritmo se reinicia Si se alcanzan 96 cuartos de hora con caudal se considerara existente la fuga hasta que el flujo haya sido cero durante 8 cuartos de hora seguidos En la memoria de incidencias se guardan la fe cha y la hora de la incidencia Detecci n de parada del contador bloqueo Si el m dulo PDC no detecta ning n avance del contador por un per odo de cuatro semanas se detectar la parada del contador bloqueo El bloqueo se considerar anulado si en un cuar to de hora aparece una diferencia de estados del contador gt 10 litros Detec
40. ssi nei summenzionati telegrammi dati avviene tramite l interfaccia ottica utilizzando Mi noConnectRadio il lettore ottico IrCombiHead e un software adatto Logger dati Vedi punto 2 nella tabella Specifiche tecniche generali 27 9 Funzioni Smart Meter Autodiagnostica Il modulo prevede un monitoraggio integrato del lo stato delle batterie Rilevamento perdite L assenza di almeno un valore pari a zero in un intervallo di 24 h 96 valori per quarto d ora nel valore di flusso indica la presenza di una perdita Il modulo PDC invia alcuni bit corrispondenti Se il flusso rimane pari a zero per un quarto d o ra prima di raggiungere i 96 quarti d ora senza flusso l algoritmo riparte Se si raggiungono i 96 quarti d ora con flusso presente la perdita rimane impostata fin tanto che il flusso non risulta pari a zero per 8 quarti d ora La memoria eventi registra data e ora dell evento Rilevamento arresto contatore Blockade Se il modulo PDC non rileva alcun progresso del contatore in 4 settimane viene riconosciuto un arresto del contatore Blockade L arresto si considera superato se entro un quar to d ora si verifica una differenza di stato nel con tatore gt 10 litri Rilevamento contatore sovradimensionato Il contatore sovradimensionato se il flusso non supera mai 0 1 Q3 il 10 di Q3 L analisi viene effettuata rispetto ad un intervallo di 15 minuti Viene contata la frequenza con cui il fluss
41. te In this way you will help to protect natural re sources and to promote the sustainable reuse of material resources A For any question please contact info zenner com The most up to date information about this prod uct and of our installation notice can be found at www zenner com 15 Technische nderungen vorbehalten F r etwaige Irrt mer und Druckfehler bernehmen wir keine Haftung SAP150691 150805_DE EN FR ITA_ES 1 Description succincte wireless bzw wired M Bus Konverter Le module PDC Pulse Data Capture est utilis pour l int gration dans des syst mes radio ou in telligents de compteurs avec sortie impulsionnelle Applications typiques m Lecture distance de compteurs d eau systeme walkby ou driveby m Transmission par radio des donn es du compteur vers des r cepteurs mobiles ou stationnaires m Lecture distance via des installations M Bus Notre module PDC permet l int gration de comp teurs conventionnels dans des installations M Bus ou radio de maniere simple et efficace Pour ce faire la sortie impulsionnelle du compteur est raccord e au module PDC qui lui fonctionne a pile Pour les compteurs d eau ZENNER qui pables d un g n rateur d impulsions nous pro posons des modules PDC correspondants munis d un g n rateur d impulsions 16 Le module PDC est disponible dans les versions suivantes m RADIO module wireless M Bus conform ment au standard OM
42. tels an Impuls Wasserz hler anges chlossenen PDC M Bus Modulen ist somit eine Auslesung der Wasserz hler ber den Bus m glich Technische Daten PDC M Bus Anzahl Kabeladern 2 Kabell nge 1 5 m Elektromagn entspricht der Richtlinie Vertr glichkeit 89 336 EWG Kabelbelegung wei M Bus 1 braun M Bus 2 Abb Anschlussschema PDC M Bus INPUT A END maus 2 INPUT B m eus a o 8 DTA English Francais Italiano 7 AES Key Die PDC Module senden ihre Datenpakete nur verschl sselt AES 128 geratespezifisch nach OMS Um den Empfang der Datenpakete und deren weitere Verarbeitung zu erm glichen ist im jeweiligen Empf nger der AES Key zu hin terlegen ZENNER liefert die AES Keys zu den Ger ten in der Regel mittels elektronischem Lie ferschein k nftig auch per Download oder per kundenspezifisch abgestimmter Datei 8 Auslesung Datenlogger Die PDC Module verf gen ber einen internen Speicher Datenlogger Die Auslesung der Da ten welche nicht bereits in den vorgenannten Datentelegrammen bertragen werden erfolgt ber die optische Schnittstelle mittels MinoCon nectRadio dem ZENNER Optokopf IrCombiHead und einer entsprechenden Software Datenlogger Siehe Punkt 2 Tabelle allgemeine Technische Daten 9 Smart Meter Funktionen Selbst berwachung Das Modul verf gt ber eine integrierte Batterie status berwachung Erkennung Leckage Wenn ber einen Zeitraum von
43. to alle istruzioni di instal lazione del generatore di impulsi in questione e mettere in funzione il modulo PDC secondo quanto descritto al punto 3 4 3 4 Messa in funzione del modulo PDC Il modulo si attiva tramite interfaccia ottica Pro grammare i parametri utilizzando il software GlobalMeterManager GMM ZENNER licenza di ConfigurationManager l interfaccia universa le MinoConnectRadio con interfaccia Bluetooth installato in un computer portatile e il corrispon dente lettore ottico a raggi infrarossi IrCombiHe ad ZENNER In alternativa possibile utilizzare al posto di un computer portatile anche un pal mare Android con licenza MeterReaderLight La configurazione minima richiede Numero di serie del contatore collegato al modulo PDC Valore iniziale valore attuale del registro del contatore collegato m Valore impulsi del contatore collegato Il rispettivo intervallo di trasmissione preimpo stato Altri parametri impostabili m Reset dei valori logger m Reset dei bit di stato manipolazione errori m AES Key in base alla licenza software L attivazione avviene automaticamente non ap pena il modulo PDC ha ricevuto pi di 10 impulsi dal generatore 25 4 Montagg io a parete del modulo PDC Installare le staffe da muro con i tasselli e le viti forniti con formemente all immagine se guente su una parete che sia il pi liscia possibile Far scor rere il modulo PDC dal basso sul su