TROUBLESHOOTING BASIC OPERATION
Contents
1. GmbH Reeshoop 1 22926 Ahrensburg GERMANY info ultimed org e www ultimed org Detected A Detected Power LED LED Button Battery Status Positive Processing Powering up Low detection analysis D UO completed i No detection Ready Charging analysis completed amp Charging complete Card error INDICATOR KEY D Green ON Yellow ON Red ON System error SE vetlow blink Indicators will light only when unit is powered on and plugged in Unit will still charge in power off state BASIC OPERATION Press POWER button release when it lights WAIT until blinking stops collect sample and insert wy card press both latches to pull door open firmly Wait until NOT DJEDA Check LED stops indicators eRe blinking for result see chart Remove card place in original bag for protection NOTE To power off hold Power Button until light goes off Do not touch card s paper portion after analysis TAKING SAMPLES EXPLOSIVES or NARCOTICS sampling methods follow label instructions on each card type a direct method grinding grinding the card s sampling paper CARD EDGES directly into the sampled surface Protruding edge r o Recessed edge b direct method swiping c indirect method use hand or surface swipe cotton swab or glove Swipe must be FIRM Not all cards may be used for hand sampling check card label If card has pr
2. ADDITIONAL INSTRUCTIONS SAMPLING TIPS e Avoid damaging card label and sampling paper Cards need to be removed immediately after analysis Cards are not reusable e Carefully follow card label instructions for sampling procedure e Swiping requires fair amount of pressure applied to be fully effective e Powderize crystals e g crack cocaine or ammonium nitrate prill by grinding a grain of sand sized sample with the sampling paper e Remove excess powder by shaking it off or tapping card once e Avoid collecting excess dust or dirt as this can interfere with detection processing For liquids apply small drop on sampling paper with cotton swab eye dropper etc Allow liquid to dry slightly e Avoid damaging card label when sampling CLEANING Clean the insi with cleaning accessory Clean as needed or at a minimum of every 20 samples Refer to cleaning accessory packaging instructions NOTE Avoid contact between swab and internal parts of the unit other than card carrier VERIFYING UNIT The cards and unit may be verified to ensure proper performance For negative detection for each card type analyze new unused sampling card green NOT DETECTED light should come on For positive detection use the verification system provided with your unit Follow the instructions included in the verification system packaging If results differ call technical support at 49 4102 800 90 TROUBLES
3. HOOTING A detection cycle does not begin when door is closed Check for damage to switch or card bump detection triggering mechanism Fully insert card into carrier and close door firmly Make sure unit is fully powered on power button should be on and not blinking Both DETECTED and NOT DETECTED lights turn solid yellow a few seconds after starting a detection cycle indicates the card label was not recognized Try a new card making sure label isn t dirty damaged or peeling Close door firmly in a swift singular motion Make sure card type is supported by firmware version Both DETECTED and NOT DETECTED lights blink yellow indicates a system error requiring manual reset Perform a manual reset Hold power button down for 15 sec release wait 10 sec then power unit on Try a new card Unit does not turn on or a detection result is not returned after 3 minutes may indicate system computer is busy Perform a manual reset Hold power button down for 15 sec release wait 10 sec then power unit on Do not attempt to power on within 15 seconds after powering off Note Ensure battery has not drained plug unit in and power on The XCAT is used for presumptive field testing Field conditions and sampling efficiency can affect results TECHNICAL SUPPORT AND ORDERING For technical support to place orders obtain sampling card MSDSs and for firmware upgrades contact ulti med Products Deutschland
4. o carrier channels paper down label facing towards unit Firmly close door to start detection process leave unit positioned upright while processing WARNINGS e Tampering will void any warranty and may affect perfor mance do not break seal e Cards must be stored properly for accuracy see box label e Do not operate near ignition sources or while smoking Use in a well ventilated area Do not operate if housing is removed or damaged Do not allow water to enter unit Do not touch sample paper on processed cards e Maximum operating temperature is 120 F Do not expose battery to flame or temperatures above 130 F Refer to Sampling Card MSDSs for safety information 2015 RedxXDefense v 26
5. otruding bottom edge use that edge for swiping Avoid excess dirt on sampling paper GUNSHOT RESIDUE GSR sampling procedure The GSR sampling card can be used to sample hands clothes or surfaces Follow STEPS as shown Tacky adhesive Plain paper for dabbing for swiping v T a Uv sas MK PINS asav Lial Se O ke v3 e Sg 2 2 oS DANGER Contains flammable and corrosive liquids A AN CAT SAMPLING CARD When sampling hands inform subject you will be applying a very firm pressure with the sampling card GSR contamination is pay concentrated in t e blue areas shown STEPS for GSR sample collection and analysis at Remove the protective liner 2 DAB tacky adhesive strip over areas marked in blue beginning with back of hand then webbing between A thumb and forefinger then palm Back NOTE Dab hand a minimum Dab first using of 50 times tacky strip 3 Next SWIPE the same then swipe areas using paper with paper A portion 4 Lift the red tab and fold adhesive onto sampling paper a Press adhesive to paper firmly with thumb to prevent tearing Then pull red tab to fully extend liner 6 While still pressing on adhesive tightly wrap the liner around the sampling card Analyze in XCAT then repeat these steps on the other hand with another card ANALYZING SAMPLES After collection analyze sample using the XCAT Open door and slide card int