Contents
1. ABB Copyright 2012 Busch Jaeger Elektro GmbH All rights reserved O BUSCH JAEGER V 1473 1 7932 Rev 01 17 12 2012
2. activation of the mains voltage the memory touch type controller switches the connected loads in dependence of the type of sensor as follows Flush mounted sensor type ON period 6810 21 10 80 seconds 6800 104 M or higher Dependent on the setting at the flush mounted sensor at least 1 minute at a time setting of 1 minute Exception is short time pulse JL O Note The On period is independent of the brightness set on the sensor 4 6 Extension units The following are possible extension units Normally open contact button e g 2020 US Switching dimming possible via extension unit button If a Busch Watchdog attachment is used with the 6550 U 10 only switching is possible Flush mounted insert 6805 U in combination with Busch Watchdog 180 sensors Operating Instructions 1473 1 7932 5 Operating Instructions Busch Dimmer Operation 4 7 Extension unit operation In connection with flush mounted sensors extension unit operation is possible via two models Activation via NO contact button Extension unit insert 6805 U Passive extension unit operation by means of NO push button The function performed on the NO contact push button causes the connected loads to be switched on as follows Flush mounted sensor type ON period 6810 21 10 80 seconds 6800 104 M or higher Depending on the setting on the flush mounted sensor O Note T The On period is i
3. on the 230V supply system may only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly 2 Intended use The device is to be used exclusively with the components that are supplied and licensed as described in chapter Setup and function 3 Environment Consider the protection of the environment Used electric and electronic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot All packaging materials and devices bear the markings and test seals for proper disposal Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies The products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EC WEEE and 2002 95 EC RoHS EU REACH ordinance and law for the implementation of the ordinance EC No 1907 2006 Operating Instructions 1473 1 7932 3 Operating Instructions Busch Dimmer Operation 4 Operation 4 1 General Lighting systems can be switched or dimmed directly via the touch type controller or alternatively via additionally connected push buttons extension units For operation the flush mounted insert has operating elements attached O N
4. 0 6810 21 101 0 8 1 2 m Bottom 6800 104 0 8 1 2 m stairwell 6800 104M Top 2 0 2 5 m room monitoring Operating Instructions 1473 1 7932 13 Operating Instructions Busch Dimmer Installation and electrical connection 7 5 Electrical connection Caution Risk of damaging the device due to excessive voltage When using different phases for the supply input L and the extension unit input 1 the voltage there could be too high 380 V Connect supply input L and the push buttons for extension unit input 1 to the same phase O Note If a protective conductor connection is used ensure that it is properly connected to the lamp and to the electronic ballast units 7 6 Extension unit input parallel operation Parallel operation Fig and Fig 3 The memory touch type controller can be operated via an extension unit In the process the following must be observed The maximum cable length depends on the admissible ripple voltage of the extension unit inputs The ripple voltage however must not exceed 100 V In practice this corresponds to a cable length of approx 100 m The number of the push buttons e g 2020 US at a cable length of 100 m is unlimited If illuminated push buttons e g 2020 USGL are used only push buttons with a separate N connection are admissible Contact parallel illumination is not admissible Do not install control and load line in t
5. 1473 1 7932 Rev 01 17 12 2012 Operating Instructions Busch Dimmer Memory Touch Type Controller 6550 U 101 6550 LLLI 6550 Memory Taststouer gerit f EVG 230V SOHr 4A DC 0 10V BN Sooo lal ae BUSCH JAEGER V Operating Instructions Busch Dimmer 1 SCIT t A 834 sats 3 2 Intended US inp Et bata Aaaa Ee ERE Ue E o ua e o edet tema 3 3 nurse Emm 3 4 Operation ee ae za a ee za ata ba SEC ia at ERR IM BEES 4 4 1 General ze aa i cae eed da ebur a aaa 4 4 2 Normal operatiori sistate cacat 0 ca Ca atat da a Rata ioe c tat e aaa a Ea ata dal a au a bee ite tae 4 4 3 Parallel operation extension unit eee eee eee neant aaa ana 4 4 4 Button mode ice so cai carea a ai a 3 RAEE a oa 2 a atol i i amy 0 a i i 5 4 5 Operation with Busch Watchdog flush mounted sensors type designation in the Busch Watchdog ee E P 5 4 6 Extension UNItS ss o dete tide e eda taa ee deese 5 4 7 Extension unit operation icio tne Ret ite niti ta ti o Di a et o a i Pa oues 6 4 8 Operation with the Busch Watchdog Presence 6813 or 6813 11 ccemme eee eee nene 6 4 9 Comfort timer control element 6455 cesses etes inini i e i 6 4 10 Adjusting the basic brightness if necessary emm emm emeret 7 4 11 Restoring the memory function after a mains power failure nenea nenea 7 5 Technical data irte a aa e xe er ite res D a EROR REM IEEE 8 6 Setup a
6. 60 90 90 100 60 20 20 60 100 Fig 2 Detection range Operating Instructions 1473 1 7932 Operating Instructions Busch Dimmer Installation and electrical connection 7 4 Mounting with Busch Watchdog Flush Mounted Sensors The memory touch type controller 6550 U 10 can be used in combination with the Busch Watchdog 180 flush mounted sensors 6810 21 10 6800 104 M or higher In this case a switching function ON OFF is possible but no dimming function The mounting height depends on the selection of the flush mounted sensor table For further information on mounting height the adjustment of the flush mounted sensors see the relevant operating instructions of the respective flush mounted sensor For push button operation please note the following The phase of the extension unit and the phase of the supply voltage must be the same and be connected to an electric circuit When laying lines ensure that there is sufficient distance between the control lines and load lines at least 5 cm The maximum line length of the extension unit cables is 100 m Changing the line routing of existing two way circuits and cross connections is not necessary 7 4 1 Mounting height application To guarantee an optimum function of the flush mounted sensors please observe the following table Flush mounted sensor Mounting height application Built in position of connecting screws type 6550U 1
7. he one cable to prevent unwanted switching processes For one electronic ballast For several electronic ballasts Fig Activation of the 6550 U 10 flush mounted version Operating Instructions 1473 1 7932 143 Operating Instructions Busch Dimmer Installation and electrical connection For one electronic ballast For several electronic ballasts Fig 3 Activation of the 6550 rail mounted version Fig 4 6550 U 10 for activation of several electronic ballasts gt 50 mA O Note Relay a serves for contact amplification and is not included in the scope of supply Operating Instructions 1473 1 7932 15 Operating Instructions Busch Dimmer Commissioning 8 Commissioning 8 1 Setting the operating mode on the slide switch Only valid for 6550 U 10 The memory touch type controller offers two different operating modes see also chapter Operation Normal mode Setting bottom I delivery status Button mode Setting top Il Es ts NL Fig 5 Slide switch 8 2 IR control element Only valid for IR remote control Mounting the IR control element 1 In the case of IR control element 6066 set the desired address first see Fig 6 2 Plug the control element onto the flush mounted version of the memory touch type controller Ensure that the IR control element does not jam in the frame Dismounting the IR control element Use the notches on the r
8. ight and left of the control element to lever it off Addressing of the IR control element The address of IR control element 6066 is is set on number 1 at the factory 1 If necessary change the address on the rear of the control element via the address wheel 2 Observe the IR receiving range when addressing Fig 1 and Fig 2 Fig 6 Addressing Operating Instructions 1473 1 7932 16 Operating Instructions Busch Dimmer 8 3 Fault rectification Commissioning Diagnosis Possible cause Fault rectification The device is permanently set to maximum brightness Control voltage 1 V 10 V is not connected Connect the control voltage 1 V 10 V Switch the mains power supply OFF ON Minimum brightness is set too high Adjustment minimum brightness Light does not come on Control voltage 1 V 10 V has short circuited Rectify short circuit Switch the mains power supply OFF ON Minimum brightness is set too low Adjustment minimum brightness Line side fuse is defective Replace fuse Fluorescent lamp is defective Replace fluorescent lamp Electronic ballast is defective Replace electronic ballast Controller is defective Replace controller Only valid for 6550 U 10 Diagnosis Possible cause Fault rectification LED of control element 6066 is OFF Infrared detection range influenced by extra
9. l current Maximum 50 mA DC Module width 2 MW 1 MW 18 mm applies only to Modular DIN Rail Component MDRC Ambient temperature range 0 35 C 6 Setup and function The device is intended for the activation of the following types of loads Qv 230 V incandescent lamps 220 230 V halogen lamps Low voltage halogen lamps with conventional transformers Nn RL 6 1 Features of function and equipment e 9 wire connection system neutral conductor is required For LED control via ballasts Without control element Norrilluminable e With integrated inrush current limiter Operating Instructions 1473 1 7932 8 Operating Instructions i Busch Dimmer Setup and function 6 2 Possible combinations Flush mounted MDRC 6550 U 101 6550 X X 6597 3099 X 2021 6 UK _ X Qui 6066 X 6543 O Note When using control element 6543 remove the plugged in illuminating element since it cannot be illuminated when combined with memory touch type controller 6550 U 10 Operating Instructions 1473 1 7932 9 Operating Instructions Busch Dimmer Installation and electrical connection T Installation and electrical connection Warning Electric voltage Risk of death due to electrical voltage of 230 V during short circuit in the low voltage line Low voltage and 230 V lines must not be installed togethe
10. nd function ee enere aa e a die poa i e C a Da ua ob aia add a at ate Ela a a 300 8 6 1 Features of function and equipment eeeessseee ian nei dentes deemed eene innere Deed 8 6 2 Possible combinations ee acasa e cae aaa a oo aaa o a d pa e atata 9 7 Installation and electrical connection mm eee eee nana nenea eee emana ae an 10 7 1 Requirements for the electrician 2 eiie i eec i cene TH d pi Ca tee sa dai 10 7 2 MOUNTING me ohh tan a o a at a id bel cag a ia t bea a au e 11 7 3 Installation with IR remote control taie ea at ct an i d c tt a e pini ees ined ner 12 7 4 Mounting with Busch Watchdog Flush Mounted Sensors enne 13 7 4 1 Mounting height application cai a ice a teet Dto i Led dee Seite tene a d d 13 7 5 Electrical coninection red der ler ae a ada aaa T 14 7 6 Extension unit input parallel operation emm enne nne 14 8 COMMISSIONING eet t ER RR EP HR EBERT RU EE ERE ER DP FERE NER DEUS TEET 16 8 1 Setting the operating mode on the slide switch mean eee neant ana 16 8 2 IR Control element cc pe coace ec eta e Da ot i Da Du i a de olita e Eat 16 8 3 Fault rectification ce cec aa eU eec eed te ta eee aa 17 Operating Instructions 1473 1 7932 2 Operating Instructions Busch Dimmer Safety 1 Safety Warning Electric voltage Risk of death and fire due to electrical voltage of 230 V Work
11. ndependent of the brightness set on the sensor Deactivation dimming is not possible via the extension unit Multiple activation when the lighting is switched on leads to a reset of the previously expired time Active extension unit operation Busch Watchdog with 6805 U and flush mounted sensors Since the main unit and extension unit each have a separate twilight value setting the current brightness conditions at the mounting position can be taken into consideration individually The actual switch OFF delay results when adding the time set on the main unit and on the extension unit In connection with flush mounted sensors 6800 104 M or higher it is recommended to operate the extension units with the short pulse time setting n when the times set on the main unit are to be precisely adhered to O Note Further information on the respective flush mounted sensor is contained in the respective operating instructions 4 8 Operation with the Busch Watchdog Presence 6813 or 6813 11 Detailed information is contained in the respective operating instructions 4 9 Comfort timer control element 6455 Detailed information is contained in the respective operating instructions Operating Instructions 1473 1 7932 6 Operating Instructions Busch Dimmer Operation 4 10 Adjusting the basic brightness if necessary With the 6550 U 10 the basic brightness is set via the attached control element With the 6550 it is set via a b
12. neous light e g sunlight illumination Remove extraneous light No mains power Connect mains power LED of 6066 flashes continuously Infrared detection range influenced by extraneous light e g sunlight illumination Remove extraneous light LED of 6066 does not flash at transmission signal No incoming signal Check reception of infrared signal Battery of IR remote control or wall mounted transmitter is empty Receiver outside if transmission signal Replace battery Check infrared detection range Operating Instructions 1473 1 7932 Operating Instructions Busch Dimmer A member of the ABB Group Busch Jaeger Elektro GmbH PO box 58505 L denscheid Freisenbergstrake 2 58513 L denscheid Germany www BUSCH JAEGER com info bje Qde abb com Central sales service Phone 49 0 2351 956 1600 Fax 49 0 2351 956 1700 Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by
13. operation extension unit Press the control element of the extension unit All memory touch type controllers are switched and dimmed simultaneously via the extension unit Lighting systems can also be operated with uniform brightness values Keep the control element of the extension unit pressed for 10 seconds The lighting systems are set to the maximum brightness value and can then be operated synchronously Operating Instructions 1473 1 7932 A Operating Instructions Busch Dimmer Operation 4 4 Button mode Only valid for 6550 U For operating mode Button mode the sliding switch must be set on II compare chapter Commissioning For button mode the relay output acts as NO contact button Button mode can be implemented both via the mechanical control elements the IR control element 6066 and via the extension unit input e Tapping The relay is activated for a brief period Holding The relay switches for the duration of the activation 4 5 Operation with Busch Watchdog flush mounted sensors type designation in the Busch Watchdog program O Note In these operating instructions both the Busch Watchdog Art No 6810 21 10 and the comfort sensors Art No 6800 10 M are designated as flush mounted sensors Please pay attention to the correct type assignment in the description The type designation can be found on the rear side of the respective device After the interruption or
14. ote ll The brightness value set last is retained after the switch off memory function The memory touch type controller only starts to control after the first operation from bright to dark the dimming direction being reversed with each stop At maximum brightness the memory touch type controller stops at minimum brightness the dimming direction changes If the dimmer is switched brighter the dimming direction is from minimum to maximum brightness 4 2 Normal operation For operating mode Normal operation the sliding switch must be set on I compare chapter Commissioning Activation Tap briefly on the control element The brightness value last set memory value will be automatically set After each dimming process the dimming direction is reversed and it is set darker or brighter Increasing the brightness Keep the control element pressed The current brightness value is adjusted brighter until the maximum brightness value has been reached Reducing the brightness Keep the control element pressed The current brightness value is adjusted darker until the minimum brightness value has been reached If the control element continues to be pressed the dimming direction changes and it is adjusted brighter again until the maximum brightness value has been reached Deactivation Tap briefly on the control element The current brightness value is saved as a memory value and the lighting system is deactivated 4 3 Parallel
15. r in a flush mounted socket 7 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the user of the electrical system e Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect from power 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth and short circuit 5 Cover or barricade adjacent live parts Use suitable personal protective clothing Use only suitable tools and measuring devices e Check the supply network type TN system IT system TT system to secure the following power supply conditions classic connection to ground protective earthing necessary additional measures etc Operating Instructions 1473 1 7932 L 40 2 Operating Instructions Busch Dimmer Installation and electrical connection 7 2 Mounting Warning Electric voltage Risk of death and fire due to electrical voltage of 230 V Work on the 230V supply system may only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly The flush mounted insert must only be installed in flu
16. sh mounted wall boxes according to DIN 49073 1 Part 1 or suitable surface mounted housings The MDRC must only be installed on mounting rails according to DIN EN 500022 The MDRC is latched onto the mounting rail O Note We recommend using a flush mounted box with an installation depth of 60 mm In combination with Presence Watchdog 6813 it must be installed on the ceiling of a room Warning Electric voltage There is the risk of personal injury and damage to property The control output 1 10 V of the memory touch type controller is no low voltage safety SELV Operating Instructions 1473 1 7932 11 Operating Instructions Busch Dimmer 7 3 Installation with IR remote control Installation and electrical connection The memory touch type controller 6550 U 10 can be used as a component within the IR remote control system In this case the memory touch type controller must be combined with the IR remote control element 6066 When installing with remote control the installation site should lie within the IR receiving range see Fig 1 and Fig 2 Please note that the IR receiving range may vary due to extraneous light e g sunlight illumination Coverage in connection with IR control element 6066 Detection range in connection with IR control element 6066 Fig 1 Coverage o 0 30 30 60 60 o 100 60 20 20 60 100 o B Q0 3 30 60
17. utton connected to terminal 1 1 Keep the control element pressed for approximately 30 seconds to enter the programming mode The memory touch type controller has switched to Programming mode when it jumps automatically to a minimum brightness value 2 Setthe lighting to the desired brightness value and then release the button Approximately 30 seconds after releasing the button the memory touch type controller jumps automatically back to maximum This indicates that the setting process has been carried out correctly If this is not the case please repeat the adjustment of the basic brightness 4 11 Restoring the memory function after a mains power failure During a mains power failure the memory touch type controller loses the previously set brightness value and switches on with the maximum brightness at its next operation The memory function is lost Procedure for restoring the memory function 1 Adjust the lighting according to the desired intensity 2 Switch the lighting off During the next activation the previous value is saved and set automatically Operating Instructions 1473 1 7932 Ly Operating Instructions Busch Dimmer Technical data 5 Technical data General Nominal voltage 230 V AC 10 96 50 Hz Nominal power 700 W VA Nominal current 4 A cos 90 9 or 3Acos 0 5 Power consumption 1W VA Extension unit input 230 V AC 10 96 50 Hz Control voltage 1 10 V DC Contro
Download Pdf Manuals
Related Search
Related Contents
Installation Manual The CAST Manual - Intelligent Agents Laboratory user manual Washing Machine Service manual - GB162-80kW/100kW - US(en) Black & Decker CM2035B Use & Care Manual Final Cut Pro 6: New Features (manual) Novatel Merlin XU870 User's Manual ISTRUZIONI XTAU1200/1215 (B) Copyright © All rights reserved.