Home
Radio Access Control Operating Instructions
Contents
1. The current status of the memory location is displayed via the two LEDs LED L and LED E Status occupied non occupied blocked LED L OFF ON ON LED E ON OFF ON In order to alter the status of the selected memory location press button L e Case a Memory location is occupied gt Memory location is blocked e Case b Memory location is blocked gt Blocking is cancelled Note It is not possible to block non occupied mem ory locations Note This is how to end programming without saving data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously 3 Function Test After switching to the function text menu F is displayed and the set impulse length of the relay impulse in seconds Alga Press button L The radio access control transmits a master telegram and the relay is switched The dis play flashes for the period of the impulse length You can use this function for example to transfer the mastercode to the door controls Note This is how to end programming without saving data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously 69104 0608 GB Function Modes There are three function modes e Operating mode e Learn delete mode e Additional function mode Operating Mode De
2. tails are in the chapter Additional Func tion Mode gt Length of the Relay Impulse Memorize the individual transmitter tele grams into the Radio Access Control The details are in the chapter Learn Delete Mode gt Memorizing Transmitter Telegrams If needed set additional additional func tions For this read the chapter Additional Function Mode Switch back to operating mode by press ing buttons L and E simultaneously The radio access control is now ready to operate Screw on the casing cover 69104 0608 GB Operating Mode When a radio telegram is received LED L lights up After receiving a memorized telegram e the memory location of the telegram is displayed e amaster telegram is transmitted and or e arelay impulse is generated Learn Delete Mode In order to switch to the learn delete mode press one of the buttons The first non occupied memory location is displayed In order to quit the additional function mode press buttons L and E simultaneously Note If you have protected access to the program ming modes learn delete mode and addi tional function mode with a numerical code see chapter Additional Function Mode gt Entering Altering the Numerical Code the display flashes 000 non U U Select the code using the buttons and press button L When the correct code is entered the first non occupied memory location is displayed
3. In the learn delete mode you can e memorize transmitter telegrams e delete specific memory locations Operating Instructions Memorizing Transmitter Telegrams In total 1 master telegram memory location 000 and 699 individual transmitter telegrams memory locations 001 to 699 can be memo rized 1 2 Using the buttons select the desired memory location Press button L for 1 sec LED L flashes for 30 secs During this time a transmitter telegram can be memo rized Press the button of the transmitter which code is to be memorized Once the radio access control has memo rized the transmitter telegram rdy is dis played Hiab Note If no button is pressed on the transmitter within 30 secs after 30 secs the error message err appears for approx 3 secs Ere After this the first free memory position is again displayed You can end the programming within the 30 secs and return to operating mode by pressing button L The display will show rdy for approx 3 secs and then ___ Deleting Specific Memory Locations 1 2 Using the T buttons select the memory location to be deleted Press button E LED E flashes for approx 5 secs When a transmitter telegram has been deleted rdy is displayed Higg Note It is not possible for you to delete non occupied or blocked memory locations see chapter Additional function mode gt Blocking speci
4. of the last 10 telegrams are displayed counting down Note This is how to end programming without saving data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously 5 Deleting the Memory Completely After switching to the Deleting the Memory Completely menu E A is displayed HBg e Press the left and right T buttons simulta neously The entire contents of the memory are de leted During the deleting procedure approx 8s the display flashes Note This is how to end programming without saving data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously 69104 0608 GB Operating Instructions 6 Entering Altering the Numerical Code After switching to the numerical code menu C__ is displayed rn O40 You can use the additional function if you want to release the programming modes learn delete mode and additional function mode using a numerical code How to enter a new numerical code 1 Using the T buttons select the desired numerical code In order to cancel the nu merical code protection choose 000 non U 2 Confirm the new code by pressing button L Note If a code with less than three digits is selected the error message err is displayed Ere Note This is how to end programming without
5. sav ing data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously Operating Instructions Additional Function Mode In order to enter the additional function mode press buttons L and E simultaneously You can switch from one additional function to the other by pressing button E In order to quit the additional function mode press buttons L and E simultaneously 1 Length of the Relay Impulse After switching to the impulse menu an left and the impulse length in seconds right is displayed A standard value of 1 sec is set by the factory l l l J You can set another impulse length between 1 and 99 seconds If no relay impulse shall be generated select the impulse length 0 1 Using the middle and or right T button select the desired impulse length in s The display flashes 2 Confirm the new impulse length by press ing button L Once the new value has been memorized the display stops flashing Note This is how to end programming without saving data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously 2 Blocking Specific Memory Locations After switching to the blocking menu the memory location 001 is displayed yo uu Using the T buttons select the memory loca tion to be blocked
6. C tive 1999 5 EC For use in EU CH FL IS N The Declaration of Conformity can be ac quired from the supplier referred to in the delivery documents Customer Service If despite correct handling faults or malfunc tions occur or if the product was damaged please contact the company at the address below ELDAT GmbH Im Gewerbepark 14 15711 Zeesen Germany Telephone 49 0 33 75 90 37 310 Telefax 49 0 33 75 90 37 90 Internet www eldat de e mail info eldat de 69104 0608 GB Radio Access Control RCA01 Display Operating Instructions ELDAT Operating Instructions Model RCA01 5001M 01 Package Content Radio Access Control Antenna with magnetic base PG screw fittings set Mounting accessories for the PCB Safety Advice Before connecting and starting up the unit carefully read through the operating instructions We will not accept any liability for personal injury or damage to property caused by failure to observe the operating instructions and in particular the safety advice Caution Electrical installation may only be carried out by a qualified electrician When installing make sure that the elec tric circuit into which the radio access control is to be integrated is at zero voltage Warning When being programmed the Radio Access Control is live Program only with the protective cover in place Do not make any unauthorized alterations or modifications to t
7. Operating Instructions Technical Details Frequency 868 3 MHz Power supply 230 VAC 10 Current consumption approx 3 VA Relay output Relay contact N O Degree of protection IP66 Operating temperature 20T to 60T Dimensions 180 x 94 x 59 mm Weight approx 480 g without antenna Table of Loads Type of load max load Resistive load Light bulbs 230 V Halogen lamps etc 16 A 3 680 VA Inductive load Halogen lamps with wound transformers 2 6 A 600 VA transformer at least 85 loaded Non compensated or series compensated fluorescent lamps with ferromagnetic ballasts 10 A 2 300 VA Parallel compensated fluorescent lamps with ferromagnetic ballasts 2 6 A 600 VA Capacitive EB electronic ballasts electronic transformers etc 4A 920VA Disposal Waste electrical products should not be disposed of with household waste Dispose of the waste product via a collection point for electronic scrap or via your specialist dealer Put the packaging material into the recycling bins for cardboard paper A and plastics Warranty Within the statutory warranty period we under take to rectify free of charge by repair or replacement any product defects arising from material or production faults Any unauthorized tampering with or modifica tions to the product shall render this warranty null and void Conformity This product conforms to the basic requirements of the R amp TTE Direc
8. fic memory locations In such in stances the error message err is displayed 69104 0608 GB 5
9. he unit Have faulty units checked by the manufac turer Intended Use The RCA01 Radio Access Control is exclu sively developed and manufactured as a receiving and transmitting unit for 48 bit radio telegrams The manufacturer does not assume any liability for damage caused as a result of improper or non intended use General Information The Radio Access Control works within the range of 868 MHz which is also used by other radio services The operation and range can therefore be affected by devices working on the same or an adjacent frequency The reception quality can be affected by a number of factors e Location e Equipment and systems without interfer ence suppression e Other transmitters within the frequency range e Atmospheric conditions and other factors In the case of malfunctions contact your specialist dealer or the manufacturer Function The RCAO1 Radio Access Control is a receiv ing and transmitting unit operating at 868 MHZ It receives up to 699 individual 48 bit telegrams and transmits a learned master telegram with which for e g the radio re ceiver of collective garage door controls can be activated At the same time a relay is switched the closer of which is available as an additional output 69104 0608 GB 4 History After switching to the history menu H__ is displayed H Press the right T button Each time the button is pressed the memory location numbers
10. tails in chapter Operating mode In the operating mode the access control receives radio telegrams transmits a master telegram and generates a relay impulse Learn Delete Mode Details in chapter Learn delete mode In the learn delete mode you can memorize transmitter telegrams and delete specific memory locations Additional Function Mode Details in chapter Additional function mode The additional function mode offers the fol lowing additional functions Operating Instructions Additional function Display Application 1 Length of the relay impulse L Changing the impulse length of the relay impulse standard value 1 sec or deactivating the relay output 2 Blocking specific memory locations e g 001 Time limited access authorization for par ticular visitors 3 Function test F Memorizing the master telegram into the control e g door gate control 4 History H Display of the last 10 telegrams 5 Deleting the memory completely EA Reprogramming the repeater 6 Entering altering the numerical code C Release of programming modes learn delete mode and additional function mode using a numerical code 69104 0608 GB Operating Instructions Mounting and Connecting 1 Unscrew the casing cover and remove the PCB 2 Mount the Radio Access Control casing at the chosen location 3 Remove the protective plastic foil from the PCB 4 Unscrew the protec
11. tive cover 5 Connect the antenna cable to the SMB socket fig 2 and position the antenna to obtain a good reception Fig 2 Connecting the antenna Oo bod SMB Socket 6 Only relay control Connect the device to be switched e g collective garage opera tor to the ST2 connecting terminals of the PCB fig 1 Attention Note the Table of Loads on page 8 7 Connect the mains cable to the ST1 con necting terminals of the PCB fig 1 Note All the cables are to be fed into the device via the M 16 20 openings using watertight PG screw fittings supplied with the repeater 8 Insert the PCB and screw down using the screws and washers supplied with the re peater 9 Replace the protective cover Start Up 1 Switch on the supply voltage The Radio Access Control first carries out an LED check __ _ is displayed The Radio Access Control is then in the operating mode see also section Operat ing Mode If a master telegram is to be transmitted Memorize the master telegram into the ac cess control The details are in the chapter Learn Delete Mode gt Memorizing Transmitter Telegrams Memorize the master telegram into your controls The details are in the chapter Additonal Function Mode gt Function Test If a relay impulse is longer than 1 sec or no relay impulse should be transmitted Change the preset impulse length The de
Download Pdf Manuals
Related Search
Related Contents
USER INSTRUCTION MANUAL Télécharger le rapport 2013 NxDBU Module User Manual - ADTRAN Support Community HORAS DEDICADAS PRECIO HORA DINERO PAGADO 19/01/05 1 U1253A User Guide 150N Draft 802.11n Wireless Router Model # AR670W User`s Manual PDFファイル - 医薬品医療機器総合機構 Introduction To Embedded Systems Development Copyright © All rights reserved.