Home
geiger-gj56.. e06 - GEIGER Antriebstechnik
Contents
1. Antriebstechnik Venetian blind motor GEIGER GJ56 E06 with electronic end stop For Venetian blinds and exterior blinds Original assembly and operating instructions EN EN Index 1 General information navernnnnnnnnnnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnn 2 2 Gu rantee uuLisk arket 2 3 Intended use ce reir T 3 4 Safety instructions 3 5 Safety instructions for assembly 3 6 Assembly note 4 7 Installation instructiOnS s errrnnnnnnnnnnnnnnnnvnnnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnn 5 8 Information for the specialist electrician 7 9 Setting of the end stops rrnrrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnensnnnenennr 7 10 Activate the programming mode eee 8 11 Programming changing the end stops eene 8 12 Referencing on the limit stop switch eese 9 13 Enable disable reference cycles eene 9 14 Resetting to factory settings eene 9 15 Obstacle detection and anti freeze protection 9 16 What to do if cree iterare 10 17 MaintenariCe oni reuerentia eee relin un 10 18 Technical data 10 19 Declaration of conformity 11 20
2. Notes on waste disposal rrrnnnnnnnnnvnvvvrnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnvnnnnn 12 1 General information Dear customer By purchasing a GEIGER motor you have decided on a quality product from GEIGER Thank you very much for your decision and the confidence placed in us Before you put this drive into operation please observe the following safety instructions It serves for the prevention of danger and for the avoidance of personal injury and damage to property The installation and operating instructions contain important information for the installer the specialist electrician and the user Please pass on these instructions if you transfer the product These instructions should be kept by the user Guarantee In the case of incorrect installation contrary to the installation and operating instructions and or constructional modification the legal and contractual guarantee for property damage and product liability lapses EN Gerhard Geiger GmbH amp Co KG 100W1537en V001 1114 3 Intended use The motors of the model range GJ56 E06 with electronic end stop are designed exclusively for the operation of Venetian blinds The motors may not be used for the operation of roller grilles garage doors furniture and lifting tools GJ 56 xx x Design options Torque in Nm For head rails at least 56 mm GEIGER Venetian blinds motor Safety instructions ATTENTION Important safety instructions For personal safety
3. it is important to follow these instructions Please keep these instructions for future reference Do not allow children to play with stationary controls Keep remote controls away from children gt The installation is to be checked regularly for defective balance signs of wear or damaged cables and springs if relevant Do observe the moving sun protection system and keep persons away until it has closed completely gt When operating the manual release with the sun protection system open please be cautious as it can fall down quickly if springs or tapes wear off or are broken gt Do not operate the device if operations such as for example window cleaning are to be carried out in the vicinity Disconnect the automatic controlled device from the mains power supply if opera tions such as for example window cleaning are being carried out in the vicinity During operation observe the danger zone Do not use the installation if people or objects are in the danger zone Urgently shut down damaged installations until repair Unconditionally shut down the unit during maintenance and cleaning operations Pinching and shearing points are to be avoided and must be secured This appliance can be used by children aged 8 and above and persons whose physical sensorial or mental capacities are impaired or who have no experience or EN know how if they have been supervised or been given instructions on the use of the appliance and if they understa
4. that it 5 is in the programming mode nm The direction in which the motor moves after the break determines the end stop to be programmed UP upper end stop DOWN lower end stop When the desired end position is reached move the motor in the opposite direction until 2 short breaks FS show the last saved position o The programming is completed C As long as the interruption of movement has not yet occurred corrections can be done Start the setting process again to adjust another end position The referencing is automatically activated if the upper end position is programmed 8 EN Gerhard Geiger GmbH amp Co KG 100W1537en V001 1114 Limit stop switch instead of upper end position Ifthe direction UP should be turned off by the limit stop switch there is no need to program the upper end stop The blind moves every time against the limit stop switch f an upper end position is already programmed and you now want to switch off with the limit stop switch the programming mode must be activated and the blind moved against the limit stop switch The lower end position is unchanged and the programming is completed The motor is now always turned off by the limit stop switch Cancel the programming mode In order to cancel the progr
5. amming mode press the programming keys programming key UP DOWN keys limit stop switch and DOWN key until the motor confirms the cancellation of the programming mode after about 3 seconds with 2 x click clack 12 Referencing on the limit stop switch The referencing on the limit stop switch can compensate a possible drifting of the upper end position due to the modified winding behaviour of the lifting tapes If the referencing has been activated see below the next UP run is done till the limit stop Switch The variation in distance between the upper limit position and the limit stop switch is stored After 5 20 and then every 50 cycles on the upper end stop the motor runs against the limit stop switch in order to test if the variations in distance have changed If this is the case the upper end position is readjusted The motor stops on the limit stop switch by the reference runs 13 Enable disable reference cycles The referencing is enabled on delivery The referencing can be enabled only if the upper end position is set on position Switching on off referencing Press the programming keys programming key UP DOWN keys limit stop switch and DOWN key between 6 and 9 seconds until the motor jerks 1 x after about 3 seconds and another time after 6 seconds for feedback Switching on off referencing A subsequent UP command with 1 x jerking enables the referencing a DOWN command with 2 x jerking disables it 14 Resetting to facto
6. chleifm hle 6 D 74321 Bietigheim Bissingen Product Venetian blind motor motor for rolling shutter motor for awnings Type designation GJ56 GR45 GU45 The designated product is in conformity with the European Directive 2006 42 EC Directive 2006 42 EC of the European Parliament and of the Council of 17 May 2006 for the approximation of laws regulations and administrative provisions of the Member States concerning machinery 2004 108 EC Directive 2004 108 EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC The conformity of the designated product with the provisions of the directives is proved in particular by full compliance with the following standards DIN EN 60335 1 DIN EN 55014 1 EN301 489 03 DIN EN 60335 2 97 DIN EN 55014 2 EN300 220 3 DIN EN 62233 DIN EN 61000 3 2 DIN EN 61000 3 3 The accredited VDE Testing and Certification Institute EU Identification No 0366 Merianstr 28 D 63069 Offenbach tests and certifies for the company Gerhard Geiger GmbH amp Co KG Authorised representative for technical data Gerhard Geiger GmbH amp Co KG Address Schleifm hle 6 D 74321 Bietigheim Bissingen p p jiter Cet CCELA Bietigheim Bissingen 15 02 2013 Hans Michael Dangel General Manager www geiger de EN 11 EN 20 Notes on waste dis
7. ctory settings for a further run downwards 10 Activate the programming mode A Prerequisite The motor is positioned between the upper and the lower end position The limit stop switch should not be pressed A The GJ56 E06 can be set with any setting switch that permits a simultaneous UP DOWN command In this case the UP DOWN keys must be simultaneously pressed instead of the programming key Activate the programming mode via limit stop switch Press the programming key of the limit stop switch or the I UP DOWN keys simultaneously until after about 3 seconds z the motor confirms end position programming activated a8 z with 1 x click clack Then release the key lt q Press programming U key for about PROS 3 seconds Activate the programming mode on the motor Press the limit stop switch and also press the DOWN key LB on the locked Venetian blind switch The motor moves for 1 second p V Press Key Keep both keys pressed for another 3 seconds The motor confirms with a short movement downwards EN 11 Programming changing the end stops The upper and lower end stops can be programmed and changed independently of each other Activate the programming mode Run the motor in the direction of the desired end position The motor interrupts its run just to show
8. e of about 15 min The blind is in the upper position actuates the limit stop switch and can no longer be moved downwards The motor was installed upside down or the lower end position has been overrun and the lift tapes were wound up incorrectly Allow free mobility of the limit stop switch Reset the end stops 17 Maintenance The drive is maintenance free 18 Technical data Technical data GJ56 E06 with electronic end stop GJ5603k GJ5606k GJ5606 GJ5610 GJ5620 Voltage 230 V 50Hz Current 0 40 A 0 40 A 0 40 A 0 60 A 0 85 A Cos Phi coso gt 0 95 Inrush current factor x 1 2 Power 90 W 93 W 90 W 135 W 190 W Torque 3 Nm 6 Nm 6 Nm 10 Nm 2x 10 Nm Speed 26 1 min Protection class IP 54 Limit switch range 200 rotations Operating mode S2 4 min S2 4 min S2 6 min S2 4min S24 min Length 319 5 mm 319 5 mm 324 5 mm 329 5 mm 356 7 mm Diameter 55 mm Weight approx approx approx approx approx 1 50 kg 1 50 kg 1 60 kg 1 70 kg 2 20 kg Ambient temperature Operation T 10 C 60 C H max 90 humidity Storage T 15 C 70 C dry and non condensing place Run time optimized version Subject to technical modifications DST 10 EN Gerhard Geiger GmbH amp Co KG 100W1537en V001 1114 19 Declaration of conformity Ss GEIGER EC Declaration of Conformity Antriebstechnik Gerhard Geiger GmbH amp Co KG Antriebstechnik S
9. installation according to the wiring rules gt Do not mount the connecting cables near hot surfaces gt Aplug for the disconnection of the motor from the power supply must be accessible after installation gt Damaged connecting cables must be replaced by GEIGER connecting cables of the same type The device must be mounted as described in the installation instructions Fixations shall not be made with adhesives since they are regarded as unreliable Assembly note When viewed from inside the room the power supply connection of the GJ56 E06 is located on the left side The straps are wound on the winding rollers from the outside The GJ56 E06 must be installed in alignment with the turning bars It is important that the GJ56 E06 is installed centrally Please make sure that the load is evenly distributed Inclined installation The inclined installation is permitted till 45 maximum to level Electric mains Direction OPEN Inside the room E di EN Gerhard Geiger GmbH amp Co KG 100W1537en V001 1114 7 Installation instructions Prior to installation please check to ensure there is no visible damage to the motor like cracks or open cables Before fixing please check the strength of the masonry and of the surface Head rail opening at top EN 5 www geiger de Head rail opening at bottom EN lt AW L FY Dy b
10. nd the possible resulting dangers Children are not permitted to play with the device Cleaning and maintenance should not be carried out by children gt The rated sound pressure level is less than 70 dB A gt Disconnect the device from the mains power supply for maintenance and replace ment of parts If the motor is disconnected via a plug connection the operator must be able to control from any place to which it has access that the plug is removed If this is not possible due to design or installation the disconnection from the power supply must be ensured via locking in the disconnected position e g isolator The motor tube can get very hot during prolonged use When working on the unit do not touch the tube before it has cooled down v vvvvvyv Safety instructions for assembly ATTENTION Important safety instructions Follow all installation instructions as incorrect installation can lead to serious injuries gt When mounting the motor without any mechanical protection of the driven parts and of the tube which may become hot the motor must be installed at a height of at least 2 5 m above the ground or of another level which provides access to the drive www geiger de EN 3 EN Before the motor is installed all cables which are not needed are to be removed and all equipment which is not needed for power operated actuation is to be put out of operation The actuating element of a manual release must be moun
11. posal Recycling of packaging materials In the interest of environmental protection please contact your local government s recycling or solid waste management department to learn more about the services it provides Waste disposal of electric and electronic equipment Electrical and electronic equipment must be collected and disposed of separately in accordance with EU regulations EN For technical questions please call our service team at 49 0 7142 938 333 They will be happy to assist you A Gerhard Geiger GmbH amp Co KG GEIG ER Schleifm hle 6 Antriebstechnik D 74321 Bietigheim Bissingen Telephone 49 0 7142 938 0 Telefax 49 0 7142 938 230 E Mail info geiger de Internet www geiger de 12 EN Gerhard Geiger GmbH amp Co KG 100W1537en V001 1114
12. r 6 EN Gerhard Geiger GmbH amp Co KG 100W1537en V001 1114 8 Information for the specialist electrician Caution Important installation instructions Mains 230V 50Hz Please follow all instructions since incorrect installation can lead to the destruction of the motor and the switching unit Alocking switch is here necessary no simultaneous UP and DOWN commands The operations with the service clamps may be accomplished only by an electrical specialist Motors with electronic limit stops can be connected in parallel nthis case the maximum load of the switching unit must not be exceeded When changing the running direction the switchover must be effected through an off position When changing the running direction the switchover time must be at least 0 2 s With a three phase network please use the same external conductor in order to control the UP and DOWN directions Electronic Connecting cables with plug connectors of the mechanical Hirschmann Company are tested and approved with limit stop couplings of the Hirschmann Company n order to prevent a malfunction caused by coupling the supply line ref NYM from the actuator switch to the motor must not exceed 100m in case of motors with electronic end stops I green yellow I blue I I gt brown l I black l I I L 4 Attention the connection diagram of the 4 or 5 pole connector is different A 4 pole connec
13. ry settings Press the programming keys programming key UP DOWN keys limit stop switch and DOWN key about 10 seconds until the motor jerks 1 x after 3 seconds 1 x after 6 seconds and 4 x EN after 10 seconds Then the motor is reset to factory settings and the referencing is activated 15 Obstacle detection and anti freeze protection For an optimal operation of the obstacle detection function move the blind from bottom to top without interruption after the programming has been completed After an obstacle detection e g obstacle or blind frozen to the window sill the UP direction is blocked A short command in the DOWN direction releases the UP direction www geiger de EN 9 EN 16 What to do if Problem Solution Motor does not run Motor not plugged in Please check the plug connection Check connecting cable for possible damage e Check the mains voltage and allow the cause of the voltage breakdown to be tested by a specialist electrician Instead of in the upwards direction motor The control leads are interchanged Exchange black brown control leads runs downwards Motor only runs in one direction Motor in the end position Run motor in the opposite direction Readjust the end positions if necessary After running several times the motor breaks down and no longer responds The motor became too hot and has switched off Try it again after a cooling tim
14. ted at a height of less than 1 8 m If the motor is controlled by a switch or pushbutton the switch or pushbutton must be mounted within eyeshot of the motor The switch or pushbutton must not be located in the vicinity of moving parts The height of installation must be at least 1 5 m above the floor Permanently installed control devices must be attached visibly In case of devices extending horizontally a horizontal distance of at least 0 4 m must be respected between the fully extended part and any other fixed element The rated speed and the rated torque of the motor must be compatible with the device The mounting accessories that are used must be designed in accordance with the selected rated torque Good technical knowledge and good mechanical skills are necessary for the motor installation Incorrect installation can lead to serious injury Electrical work must be carried out by a qualified electrician in accordance with the regulations in force locally Only use connecting cables that are suitable with the environmental conditions and which meet the construction requirements see accessories catalogue If the device is not equipped with a connecting cable and a plug or other means for disconnecting from the mains with a contact opening on each pole according to the conditions of the overvoltage category Ill for full disconnection a disconnecting device of this type must be incorporated into the permanently installed electrical
15. ting cable must be used for the motors The GEIGER Flat4 with light blue ring The motor might start running unexpectedly if a 5 pole connecting cable with continuous power supply is used 9 Setting of the end stops General information In order to set the end positions of the GJ56 E06 motors any setting switch can be used that has a programming key or that allows a simultaneous UP DOWN command In this case the UP DOWN keys must be activated simultaneously instead of the programming key The motor can also be operated with the limit stop switch and a standard switch Article number GEIGER setting switch M56F152 with service terminal D 5 wires SMI compatible M56F153 with service terminal CH 5 wires SMI compatible M56F154 with service terminal D 4 wires Important please observe the connecting diagram on the back of the setting switch Factory setting The motor is set on the lower end position at the factory The upper end stop is at the very other end at least lower end stop 200 motor rotations The motor command is in normal operation The referencing is enabled on delivery www geiger de EN 7 Q Note If the motor is installed in a closed Venetian blind and if the limit stop switch is used the motor can be operated without further settings If the factory setting has been carried out and if the programming mode is activated max 100 revolutions can be done downwards Reset to fa
Download Pdf Manuals
Related Search
Related Contents
排気・排水に係る放射性同位元素濃度管理ガイドライン 取扱説明書 - M 工 事 説 明 書 PDF (39k/8ページ) - コダック FE-130/X-720/X-740 FE-140/X-725 Declaración de garantía BUTLLETÍ DE Febrer-Març NOVETATS 2011 Sony SS-SP40FW User's Manual Edimax BR-6428n Copyright © All rights reserved.