1. Check fuse Allow unit to cool for around 5 minutes Remove foreign body from sensor panel clean proximity switch sensor panel Distance from fixed object should be min 300 mm If the problem cannot be remedied using the methods described above disconnect the fuse and refer service to a qualified engineer or contact the Customer Helpline detailed below All repairs to the hand dryer must be carried out by a suitably qualified person This product complies with the European Safety Standard EN60335 2 23 and European Standards EN55014 2 1997 EN550141 A1 1997 EN61000 3 2 A12 1996 EN61000 3 3 1995 for Electromagnetic Compatability These standards cover the requirements of the EEC Directives 73 23 EEC and 89 336 EEC E Glen Dimplex UK Ltd oy Dim le Millorook House Grange Drive Hedge End Southampton S030 2DF Customer Helpline Tel 0870 727 0101 8am 6pm Mon Fri 8 30am 1pm Sat Fax 0870 727 0102 Republic of Ireland 01 842 4833
2. e supply voltage IMPORTANT READ CAREFULLY AND RETAIN FOR FUTURE REFERENCE Supply cable is not supplied with this appliance Supply cable used should be suitable for the rating of the appliance For wiring between the dryer and the spur outlet or isolation switch use a suitable heat resisting cable e g butyl rubber or high temperature PVC insulated The supply circuit to the dryer must incorporate a suitably rated double pole isolating switch having a contact separation of at least 3 mm in all poles Before carrying out any further mounting work disconnect the relevant circuit from the mains supply Strip the power supply cable and guide it through the opening in the back plate of the device or the screwed cable gland Screw the back plate of the unit to the wall Connect the electrical cable to the terminal Note the terminal labels Final assembly Insert plug A on the sensor cable into socket B Make sure that the cable will not be pulled in any way when the casing cover is put on and that the cable cannot come into contact with moving parts Replace the casing cover Insert the two casing screws in the bottom of the casing cover C and screw them in tightly Trouble shooting Problem No stream of hot air The sensor panel of the proximity switch has been deliberately covered with something like chewing gum or adhesive strips Unit will not switch off Distance from fixed object beneath dryer e
3. g sink or shelf too small Operation When in use the air outlet grille gets hot Do not touch it or cover it The hand dryer has an infrared proximity switch which switches on automatically when hands are placed underneath the air outlet grille to be dried and stays on until the hands are removed from the stream of hot air The unit runs on for approximately 3 seconds If the unit is too sensitive ask a suitably qualified person to change the jumper position on the electrical circuit board there are two positions for high and low sensitivity Please refer to the separate service information for details Maintenance WARNING DISCONNECT FROM THE MAINS SUPPLY BEFORE CARRYING OUT ANY MAINTENANCE This dryer does not require any special maintenance Cleaning The external appearance can be maintained by wiping occasionally with a damp cloth for stain removal a weak soap solution can be applied then wipe dry Do not use abrasive products which could damage the polyester coating Guarantee Your product is guaranteed for one year from the date of purchase We undertake to repair or exchange free of charge within the guarantee period any part foud to be defective Your rights under the guarantee are additional to your statutory rights which in turn are unaffected by this guarantee If the product is not working correctly please contact our Customer Helpline on 0870 727 0101 This guarantee only applies in the United Kingdom
4. ion Type of mounting Operation Proximity switch Time delay Run on time of min 3 seconds Air throughput 470 m h Dimensions W x H x D 278 x 248 x 210 mm Weight approx 6 5 kg Materials supplied with hand dryer The hand dryer comes complete with a drilling template and fittings Installation and Operating Instructions T020406 A Installation Undo the casing cover screws using the spanner supplied and remove the casing Mount the hand dryer on a vertical wall with the air outlet opening pointing downwards bearing in mind the mounting dimensions and minimum clearances detailed below 735 mm gt 135 5 mm Inlet for power supply cable TI Recommended installation height H Adults 115 cm children 80 cm There must be a minimum clearance of 220 mm on either side Mark the four mounting holes using the template supplied see diagram above The screws and Rawlplugs for wall mounting are supplied with the unit However specialist mounting materials may need to be used according to the method of construction e g lightweight partition walls Seek specialist advice When inserting the Rawlplugs be careful of existing electrical cables in the walls Risk of electric shock Drill 8 mm holes for the Rawlplugs and insert the plugs Electrical connections WARNING THIS PRODUCT MUST BE EARTHED This dryer must be used on an _ supply only and the voltage marked on the dryer must correspond to th
5. xXDimplex HD20A Hand dryer Important Safety Advice WARNING THE SURFACES OF THIS UNIT CAN BE HOT WHEN IN USE THE AIR OUTLET GRILLE GETS HOT DO NOT TOUCH IT OR COVER IT WARNING DO NOT USE THIS DRYER IN THE IMMEDIATE SURROUNDINGS OF A BATH A SHOWER OR A SWIMMING POOL IMPORTANT DO NOT COVER THE HAND DRYER Do not obstruct the air circulation around the dryer as this could create a fire risk NEVER cover or obstruct in any way the air inlet or outlet slots in the casing of the dryer FOLLOW these instructions carefully General Description of hand dryer The sole purpose of the hand dryer is to dry hands The hands are dried in a stream of warm air that flows out of the air outlet grille The hands can be rubbed together to accelerate drying The hand dryer has an infrared proximity switch This switches the unit on automatically when the hands are held beneath the air outlet grille If the hands are removed from underneath the air outlet grille the infrared proximity switch switches the device off after a delay of approximately 3 seconds The hand dryer must be mounted in a closed room and must be mounted on a vertical wall with the air outlet opening pointing downwards The unit is not suitable for free standing applications Technical specifications Type HD20A Operating voltage 230 V 50 Hz Power 2250 Watts Degree of protection IP 23 Protection class 1 Fixed connection Wall mounting Type of connect
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi (FR) Atlinks-Versatis P110, P160, P110&P160 Duo Trio User Menu Mode d`emploi Français Katadyn PowerSurvivor 80E User Manual - GS Global Resources Dualit 84145 CHEMICAL MOVEMENT IN LAYERED SOILS, CMLS Parallels Transporter® XGT Panel Copyright © All rights reserved.
Failed to retrieve file