1. OPERTIS Operating instructions ES7810 cabinet lock set Lock parts ES7830 ES7840 ES7850 eLOCK GB Operating instructions ES7810 cabinet lock set Contents 1 INILOQGUCH ON secret a a nee eue na Cane der G e de Loaded 4 ADOULTNESEINSIUC LIONS SE een 4 Explanation of the symbols and signal words used nenne nenn nennen 4 ALOE FOTO U ee eier 4 OPE INS SUDO Os aan ed een ae one nes 4 LB OAI AIO Meat O ME een ek 4 2 PFOOUCE AESCHIPION need 5 GOA Oe I DAS es nine ee ecasaeeeuaes 5 POSSIDIE COMDINAUONS een 5 Operating principle arena een 5 DEt lled INIOLMAUORn R A AAE S ASE 6 INnlended USE sesse a a a ee ee ehe 6 OO SRE de LER en dd On a as eet BG de en 6 Condition of the product iii 6 AMDIENESONGIONS SR ne en RE 6 PS SIU GN ISK RE 7 A Salet INSUWUCHONS zu ee 8 5 Operation and CONLHOIL SSSR ee Na 9 Setting the programming card and programming identifiers 2002220222002220 ern 9 Replacing Ne Dalley smena Ne 12 ACOUSIIE SIGUA sinan Sd de 13 6 Maintenance and cleaning uuusuauu0nau00nanunnanunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn anne 14 PES LA LOIRE AT ETS iisirsasaienitpecieaiearatintennonteavaxaiba abeaeloasdonattaciestnguainenbuntweddaaaiba tbeaeeadtoxaiezestentet 14 leaning and Maintenance as 14 7 Problems and Solutions zen a en nn ae 15 PrOQUCI SPECICATION an anna anne Renee 15 Declaration Of Conformity sise 15 DIMENSION RS een ee ee sen sen den eh senc
2. Humidity for operation and max 95 non condensing storage Memory capacity in the cabinet OPERTIS lock Identifier 49 9 Disposal Product ST Disposal in accordance with WEEE Directive 2002 96 EC O Do not dispose of product in the local household waste O Send product back to OPERTIS or dispose of it at a communal collection point for hazardous electronic wastes Batteries X O Do not dispose of batteries in the local household waste system but instead at the public battery collection points O Do not throw batteries into a fire O Do not store used batteries together O Only dispose of batteries ifthey are discharged Notes 18 OPERTIS 01 2013 eLOCK GB Operating instructions ES7810 cabinet lock set 01 2013 OPERTIS 19 OPERTIS GmbH Prof Bier Stra e 1 5 O P RT S D 34454 Bad Arolsen Telefon 49 5691 87741 0 Telefax 49 5691 87741 310 info opertis de www opertis de M7000 35GBB V000 01 2013
3. Operating instructions Detailed information Further information on the product is given in Section 8 Product specification 3 Intended use Area of use The cabinet lock is suitable for wooden furniture with maximum wood thickness 20mm depending on the type of identifier See following table The lock is mounted on the inside of the furniture in conjunction with the corresponding lock part It is intended for use within the protected interior of a building ES number Transponder Scanning range ES7910 up to 20 mm ES7930 up to 16 mm ES7940 up to 16 mm ES7941 up to 20 mm Other transponders on request Condition of the product Cabinet locks may only be used if they are in faultless technical condition Independent modifications and changes to the product are not allowed Ambient conditions Use on metal furniture or in particularly harsh environments with conditions such as high humidity aggressive gases or extreme temperatures is not allowed If you have any questions please contact OPERTIS Support CAUTION Risk of damage to property The battery operated cabinet lock emits an acoustic battery empty warning signal when the battery power is drawing to an end The battery should then be replaced without delay Ignoring the battery empty warning causes the cabinet lock to remain open all the time It does not close again until a new battery is inserted Rarely used locks should be opened at least once a quarter in order
4. can register up to 49 identifiers Opening the lock Proceed as follows Step 10 OPERTIS Activity Figure Hold the identifier in front of the position sticker Two ascending tones sound The door or drawer can now be opened The lock closes automatically after 3 seconds 01 2013 eLOCK GB Operating instructions ES7810 cabinet lock set Delete individual identifiers Proceed as follows Step Activity Figure 1 Hold the programming card in front of the lock A fast consecutive clicking PERTIS signal is sounded Master for ES7810 2 Hold the identifier in front of the lock within three seconds 3 Four constant tones confirm that the identifier has been deleted Delete all identifiers Proceed as follows Step Activity Figure 1 Hold the programming card in front of the lock A fast consecutive clicking A PERTIS signal is sounded Master for ES7810 2 Continue to hold the programming card in front of the lock A consecutive clicking signal is m sounded A long tone then eo confirms that all identifiers have been deleted 01 2013 OPERTIS 11 GB eLOCK ES7810 cabinet lock set Operating instructions Replacing the battery Note Note the details of the battery type given in the Technical Data section CAUTION Risk of damage to property If locks are used rarely the batteries should be replaced after two years at the latest There is a risk
5. caused by improper handling CAUTION Material damage due to incorrect cleaning Incorrect cleaning can affect and damage the surfaces O Clean the cabinet lock from the outside only O Do not use alkali acidic or chlorine containing cleaning agents O Do not use cleaning agents containing abrasive additives O Do not use abrasive instruments e g brushes O Do not allow oil or grease to get inside the cabinet lock Maintenance Proceed as follows Once a year wetten the stop bolt See surround at the lock part using Fin Super OPERTIS ES0281 maintenance set Cleaning and maintenance Proceed as follows Step Activity Figure 1 Wipe down surfaces with a clean dry and lint free cloth only 14 OPERTIS 01 2013 eLOCK GB Operating instructions ES7810 cabinet lock set 7 Problems and solutions Problem Possible cause Solution Cabinet lock does not Register the identifier open authorised Identifier is defective Replace the identifier Battery is empty or Replace the battery and defective operate the cabinet lock once Programming card Wrong programming Please contact does not respond card register OPERTIS Support See page 4 8 Product specification Declaration of Conformity 01 2013 OPERTIS GmbH herewith declares that the cabinet locks conforms to the fundamental requirements and other relevant regulations of ETSI EN 300 330 2 04 2006 and ETSI EN 300 330 1 04 2006 and is in conformi
6. e 16 LSCHHICAl OA een Re kennst 17 DIS DOS als ee area ee eisen ee eier 18 POJU LE ee ee 18 BACH a a er een 18 NOTOS erlebe te ee nee 18 01 2013 OPERTIS 3 GB eLOCK ES7810 cabinet lock set Operating instructions 1 Introduction About these instructions These instructions contain important information with regard to the operation of the set for the ES7810 cabinet lock O Read through the instructions carefully O Keep the instructions in a safe place and pass them on to each subsequent owner user of the cabinet lock ES7810 set Explanation of the symbols and signal words used WARNING Indicates hazards which could result in severe or fatal injuries CAUTION _ ndicates hazards which could result in minor or moderate injuries CAUTION Indicates hazards which could result in damage to property Indicates information and tips for optimum use of the mole instructions and the product Target group These instructions are directed at competent personnel entrusted with the servicing care disposal and maintenance of fault free operation of cabinet locks and who have received suitable training for these activities or have appropriate experience OPERTIS Support lf you have any questions which are not answered by the information provided in these instructions please contact OPERTIS GmbH Prof Bier StraBe 1 5 D 34454 Bad Arolsen Tel 49 5691 87741 200 Fax 49 5691 87741 281 Email support opertis de Up to da
7. erating instructions 4 Safety instructions The following safety instructions must be noted and followed before use OPERTIS does not accept any liability whatsoever for personal injuries or damage to property caused by failure to follow these instructions WARNING Risk of personal injuries due to the battery Improper handling of the battery can result in health damage Note and comply with the following instructions Only use batteries supplied or approved by OPERTIS Do not open solder or weld the battery Do not throw the battery in a fire Do not recharge the battery Remove the empty battery from the cabinet lock immediately Keep the battery out of reach of children Do not touch a leaked battery without appropriate protection Do not bring into contact with the eyes or mouth 00000 OO CAUTION Risk of damage to property Malfunctions can occur if unapproved types of battery are used The fitting then does not signal any battery warnings Only use battery types approved by OPERTIS CAUTION Risk of damage to property Electronic components can be irreparably damaged if touched Note and follow the regulations and instructions in the EN 61340 5 2 standard 8 OPERTIS 01 2013 eLOCK GB Operating instructions ES7810 cabinet lock set 5 Operation and control Setting the programming card and programming identifiers The identifiers are programmed directly into the cabinet lock without a programming device or
8. separate software Note Registering the programming card The programming card must always be registered before installing the ES7820 cabinet lock as a button at the rear of the cabinet lock must be pressed for the registering process Subsequent registering of the programming card requires the cabinet lock to be dismantled first Identifiers can also be registered following the installation Caution Storage of the programming card Following use the programming card must be kept in a safe place and protected from unauthorised use The programming card can be used to authorise identifiers for the lock at any time Setting the programming card Proceed as follows Step Activity Figure 1 Press the button at the rear of the cabinet lock A fast consecutive clicking signal is sounded 2 Hold the programming card in front of the lock within three seconds oPenr s 3 Two short ascending tones Sounds confirm that the programming card has been saved 01 2013 OPERTIS 9 GB eLOCK ES7810 cabinet lock set Operating instructions Registering the identifier Proceed as follows Step Activity Figure Hold the programming card in front of the lock A fast consecutive clicking amp signal is sounded RTIS Master for ES7810 Hold the identifier in front of the lock within three seconds Two short ascending tones confirm that the identifier has been saved In this way you
9. te information All details of the product images dimensions and versions are correct at the time of delivery of the product We reserve the right to make changes in line with technical progress and the resulting continuous improvement process of our products The current version of these instructions and further information is also available on our internet site www opertis de Dated 01 2013 4 OPERTIS 01 2013 eLOCK GB Operating instructions ES7810 cabinet lock set 2 Product description Component parts The following cabinet lock variant is described in these instructions Art No Name Figure ES7820 Cabinet lock ES7830 Lock part made of metal with ejection spring Possible combinations The following lock parts can be combined with the cabinet lock Art No Name Figure ES7840 Lock part made of plastic for double doors ES7850 Frontal lock part for sliding doors Operating principle 01 2013 The ES7820 cabinet lock locks by means of a stop bolt on the lock part optionally made of plastic or metal The lock locks automatically 3 seconds after opening The cabinet lock is programmed solely via a programming card No programming device software or other aids are required Various types of passive identifiers without an independent power supply are available for example key fobs or cards for authorisation at the ES7820 cabinet lock OPERTIS 5 GB eLOCK ES7810 cabinet lock set
10. that the lock can no longer be opened electronically Proceed as follows Step Activity Open the furniture door with the help of the identifier and press down the clip to open the battery compartment 2 3 Insert the new full battery as drawn in the cabinet lock 4 Close the battery cover and then carry out a test opening 12 OPERTIS 01 2013 eLOCK Operating instructions Acoustic signals Mode Programming mode GB ES7810 cabinet lock set Acoustic signal Meaning Continuous fast Programming mode switched consecutive on clicking signal lasting approx 7 seconds Programming mode 9 ascending tones Card successfully registered Programming mode 4 constant short tones Card deleted Programming mode Normal operation 01 2013 Continuous consecutive All authorised identifiers have clicking signal lasting been deleted approx 15 seconds Then one long tone Normal operation 2 ascending tones Furniture lock opened successfully Normal operation 4 constant short tones Card not authorised Continuous tone lasting Battery warning The battery approx 15 seconds must be replaced without delay The lock is continuously open while the battery is empty OPERTIS 13 GB eLOCK ES7810 cabinet lock set Operating instructions 6 Maintenance and cleaning Maintenance and cleaning may only be carried out by qualified personnel We do not provide any warranty whatsoever for damage
11. to check the battery condition 6 OPERTIS 01 2013 eLOCK GB Operating instructions ES7810 cabinet lock set 01 2013 Residual risk lf used properly as intended and in compliance with the maintenance instructions this product will help to maintain your property security However the following residual risks cannot be excluded CAUTION Risk of damage to property There is a risk of permanent locking if the electromechanical components fail In this case it is only possible to open the door by means of a mechanical emergency opening Each lock part has a predetermined breaking point Depending on the lock part the breaking point reached till 35 kg lf the battery is suddenly and completely discharged the cabinet lock does not work It does not signal any battery warnings It is only possible to open the door by means of a mechanical emergency opening Each lock part has a predetermined breaking point Depending on the lock part the breaking point reached till 35 kg CAUTION Risk of damage to property If locks are seldom used the batteries should be replaced after two years at the latest There is a risk that the lock can no longer be opened electronically In this case it is only possible to open the door by means of a mechanical emergency opening Each lock part has a predetermined breaking point Depending on the lock part this lies between 25 kg and 35 kg OPERTIS 7 GB eLOCK ES7810 cabinet lock set Op
12. ty with CE A copy of the Declaration of Conformity can be obtained through OPERTIS Support OPERTIS 15 GB eLOCK ES7810 cabinet lock set Operating instructions Dimensions All dimensions given in mm Cabinet lock BU a Lock part made of plastic for double doors ES8740 50 18 a ca Frontal lock part for sliding doors ES7850 24 6 16 OPERTIS 01 2013 eLOCK GB Operating instructions ES7810 cabinet lock set Technical data ES7820 cabinet lock Dimensions 60 x 60 x 22 mm Surface Plastic Lock part made of metal with ejection spring ES7830 Dimensions 60 x 20 x 20 mm Metal Predetermined breaking point At 35 kg Material Lock part made of plastic for double doors ES8740 Dimensions 66 x 50 x 18 mm Material Plastic Predetermined breaking point At 25 kg Frontal lock part for sliding doors ES7850 Dimensions 60 x 19 x 24 6 mm Material Plastic and metal Predetermined breaking point At 35 kg Power supply Supply voltage 3 volt lithium battery CR123A OPERTIS Art No ES0892 Approved battery types O Panasonic CR123 Battery life Depending on use conditions and fitting type O Operation in standby O upto 3 years or O Closures total O up to 30 000 closures 01 2013 OPERTIS 17 GB eLOCK ES7810 cabinet lock set Operating instructions Specific data Operating temperature 2 C to 40 C Storage temperature 2 C to 40 C
Download Pdf Manuals
Related Search
Related Contents
HP Compaq LA2006x Omega Speaker Systems OME-DB-889D User's Manual 取扱説明書 (施主様向) Manual de Instrucciones に関するお詫びと訂正 - 浄水器・ZWATER 逆浸透膜(RO水) CSB クリアアクリル社名板取扱説明書 Datasheet for #sbcw2887 DN Recommendations: Please read the Table de cuisson Cooking Hob Placa de cozinha Placa Copyright © All rights reserved.