Home
Symmons SLW-4412 Instructions / Assembly
Contents
1. SS panhead 2 LN 128 Escutcheon widespread 2 LN 129 Gasket Escutcheon 2 Handle kit LN 138 Washer 2 handles LN 142 Valve body 2 hot amp cold LN 150 O ring 2 LN 157 Flex hose 2 LN 177 Cross handle 2 LN 185 Gasket spout LN 188 Centerbody LN 189 Centerbody tee nan con LN 243C Plug button porcelain cold LN 243H Plug button porcelain hot LN 254A Spout P 108CL12 Lift rod for pop up drain assembly RT 103N Nut flanged 2 SPF 26 Nut Hex centerbody WSF CRP KIT Handle kit qty 2 handles For Decorative Finish Faucets add suffix to parts marked with an asterisk as follows Suffix STN Radiance satin finish Aerator Part Number flow regulator Standard Aerator 2 2 gpm 8 3L min SER i Le 1 5 gpm 5 7L min LN 741 Grid drain i ID Pop up drain assembl 1 0 gpm 3 8L min optional p up aral y without lift rod 4 30 09 Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 781 848 2250 Fax 800 961 9621 781 664 1300 Website www symmons com Email customerservice symmons com S M MON S 2007 2008 Symmons Industries Inc Printed in U S A ZV 577 m 043009
2. to lift rod 2 lift strap to pivot rod It is very important to thoroughly flush the supply lines to prevent foreign matter i e copper chips sand stones etc from damaging the sealing surfaces of cartridge Remove aerator and open hot and cold to full open then open both supplies Let water run through hot and cold long enough to flush supply lines thoroughly Shut off faucet and replace aerator Check for leaks Replacing cartridge KN 113 or KN 114 1 Remove plug button LN 243H or LN 243C loosen Philip head screw LN 121A and remove handle LN 177 Remove collar LN 112 by turning counter clockwise Caution Do not use wrench as this may damage the surface finish Place wrench on cartridge hex nut KN 113 KN 114 Turn wrench counter clockwise until cartridge is removed Install new cartridge Turn cartridge with wrench until cartridge does not turn easily then turn 1 4 to 1 2 turn further Reassemble handle in reverse fashion Dimensions Carrington Widespread Lavatory Faucet SLW 4412 1 9 16 40mm 102mm min Ry 2K xx Q Note Dimensions subject to change without notice LEE Flexible connectors KZ Ky KOR 5 B oe lt gt 2 ke LY Se ia Parts Assembly Carrington Widespread Lavatory Faucet SLW 4412 KN 113 Valve cartridge cold KN 114 Valve cartridge hot L 26 O ring 2 plug button L 42 Nut 2 LN 112 Collar 2 LN 121A Handle screw M4x10
3. SYMMONS Carrington PR Widespread Lavatory Faucet SLW 4412 Installation and Service Instructions Caution Be sure to turn off hot and cold water supplies before installing or servicing faucet Installation Procedure 1 Push valve bodies through holes in sink from underneath Make sure mounting nuts RT 103N are on underside of sink Valve marked Hot is on the left and Cold is on the right Put gasket LN 129 over valve body Thread escutcheon LN 128 onto valve bodies The top of the valve spindle should measure 1 7 8 from mounting surface See rough in drawing Thread collar LN 112 on to valve body until it reaches the escutcheon LN 128 Tighten mounting nuts from underneath sink CRP handle installation Place lever part of handle on valve spindle and thread screw LN 121A into valve Install spout LN 254A and centerbody LN 188 through center in sink hole from above sink Secure spout to sink with washer LN 138A and nut SPF 26 Washer LN 1384A flat should face back of the sink Thread tee LN 189 to bottom of centerbody LN 188 Thread flex hoses LN 157 into tee LN 189 using pipe dope or teflon tape on the pipe threads Thread other end on to valve bodies Connect hot supply to left tube and cold supply to right tube using appropriate connectors Pop up drain installation a Remove pop up plug tail piece and flange from the drain body Make sure that locknut is threaded all the way do
4. wn onto the body with flat friction washer in middle and beveled washer on top b Apply plumbers putty or sealant to bottom of flange c Install drain body through drain opening in lavatory and screw flange onto the drain body making sure that the threads are completely engaged for proper sealing and strength of the connection Apply joint compound to all threaded parts to insure proper seal d Tighten locknut to compress the beveled flange evenly across the bottom of the drain opening taking care not to over tighten the locknut causing damage to the lavatory Apply teflon tape clockwise on tail piece and thread into outlet of body i aa amp a 4 5 GR Fie Ti SS f i a aa SES 5S EN ia S p e Insert pop up plug and pivot rod into body and tighten retaining nut until the ball is seated on the ball washer Note The pop up plug can be installed either in the removable or non removable position depending on the location of the hole located in the guide at the bottom of the plug f Slide the pivot rod through one side of the spring clip then the appropriate adjustment hole and then other side of the spring clip g Insert lift rod through faucet housing and the top of the lift strap and secure it in place by tightening the screw Note To insure proper operation of lift rod and pop up some adjustment of the linkage may be required There are two possible adjustment points 1 lift strap
Download Pdf Manuals
Related Search
Related Contents
La place de la langue dans le manuel numérique Place au Théâtre FORAY® 48BA Insecticide biologique en suspension 手書きちらし作成マニュアル Copyright © All rights reserved.
Failed to retrieve file