Home
Broan 614804 Use and Care Manual
Contents
1. 8 Ceiling 9 Ceiling 10 Ceiling Standard Flues Minus 24 29 25 plus 30 WIRING Note This range hood must be properly grounded The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes GROUNDING INSTRUCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded 33 7 16 85cm max WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified electrician install an outlet near the appliance Set the electrical power supply within the space covered by the decorative flues Position the power socket at a maximum distance of 33 7 16 85 cm from where the lead exits from the hood see illustration alongside Make sure this does not interfere with the decorative flues where the flue touches the wall Fit the plug into the power socket CONNECT DUCTWORK 1 Use 2 screws
2. 4 8x38mm and drywall anchors to secure flue mounting bracket to the ceiling or wall as shown Use 8 round metal duct to connect the discharge collar on the hood to the ductwork above Use duct tape to make all joints secure and air tight Connect the upper flue to the bracket with mounting screws 3 9x9 5mm Slide the lower flue downward until it fits properly around hood Secure lower flue to hood with mounting screws 3 9x9 5mm FIXING TO THE WALL El e LB Ee I w i MOUNTING SCREWS 4 FLUE Caseta MOUNTING BRACKET FIXING TO THE CEILING MOUNTING SCREWS 4 8x38mm FLUE MOUNTING BRACKET FASTEN FLUE TO HOOD AND BRACKET WITH MOUNTING SCREWS 3 9x9 5mm 9 DECORATIVE gt FLUE DUCT TAPE 8 ROUND METAL DUCT MAINTENANCE Proper maintenance of the Range Hood will assure proper performance of the unit Grease Filters The grease filters should be cleaned fre quently Use a warm detergent solution Grease filters are dishwasher safe Remove filter by pushing filter towards the back of hood and rotating filter downward GREASE FILTERS Hood Cleaning Stainless steel is one of the easiest materials to keep clean Occasional care will help pre serve its fine appearance Cleaning tips e Hot water with soap or detergent is all that is usually needed e Follow all cleaning by
3. Convoyador Motor Manilla del motor Almohadilla antivibraziones Cabos Placa marca Tubo decorativo inferior Tubo decorativo superior Soporte de montaje del tubo Sujeta cabos Caja cabos alimentaci n Tapa de la caja cabos alimentaci n Terminal Terminal Sujeta cabos Caja de instalaci n el ctrica Caja terminal Terminal Soporte superior Trasformador Caja fusible Soporte motor Soporte caja de alimentaci n Caja de la l mpara hal gena Tapa del cuadro el ctrico Accesorios para el montaje Conjunto motor Incluye los N 42 48 49 53 68 69 Conjunto mandos Incluye los N 222 223 226 225 224 228 229 230 165 166 Conjunto casquillo Incluye los N 56 57 Fusible Portafusible 34 SERVICE PARTS LISTE PIECES DE RECHANGE LISTA DE PIEZAS DE RECAMBIO MODEL 61000 48 VERSIONS 57 120 N119 147 cod R2300182 474 165 cod 08295008 45 223 208 222 225 226 224 53 228 230 42 165 cod 03294781 SS 7 LESS gt e SS G R lt gt oo oS Whe SS 4 e RE NTS a gt Ss SR D Xe GE d 7 Me R os Z ee Q lt lt LESS A A 22 ES 2 se Zee Sov A fr D Z BEE NA X SAR SRY SAA 147 cod R2300185 04307730 6
4. T3 12V 20W G 4 Base No toque la l mpara de repuesto con las manos desnudas 30 SUSTITUCION FUSIBLE DESCONECTAR EL APARATO FUSIBLE PLACA INSTALACION ELECTRICA Remover los filtros antigrasa Desmontar la placa de la instalaci n el ctrica y abrir la caja fusible Sustituir por un fusible del mismo tipo 5x20mm 4A 125V FUSIBLE GARANTIA GARANTIA BROAN POR UN A O Broan NuTone LLC Broan NuTone garantiza al consumidor comprador de sus productos BROAN que dichos productos no tendr n defectos en los materiales o fabricaci n durante un periodo de un a o a partir de la fecha de la compra NO HAY OTRO TIPO DE GARANTIAS QUE INCLUYAN O SE LIMITEN EXCLUSIVAMENTE A GARANTIAS IMPLICITAS O DE CAPACIDAD COMERCIAL O CONVENIENCIA PARA UN PROPOSITO ESPECIFICO Durante el periodo de un a o Broan NuTone si lo estima conveniente reparar o reemplazar sin gastos para el usuario cualquier producto o parte de ste que sea defectuosos habi ndose usado correctamente p ESTA GARANTIA NO CUBRE ESTARTER DE NEON NEON LAMPARAS HALOGENAS LAMPARAS DE ILUMINACION FUSIBLE FILTROS CONDUCTOS TAPAS DE TECHO TAPAS DE PARED Y OTROS ACCESORIOS PARA LOS CONDUCTOS Tampoco cubre el mantenimiento ni los productos o partes de stos que hayan sido usados de forma incorrecta con negligencia rotos accidentalmente o por una incorrecta manutenci n 6 reparaci n distinta da la realizada por Broan
5. a la p riode de un an stipul e pour la garantie expresse Certains Etats ou provinces ne permettent pas de limites quant la dur e d une garantie implicite La restriction susmentionn e peut donc ne pas s appliquer dans votre cas BROAN NUTONE S L OBLIGATION POUR BROAN NUTONE DE REPARER OU DE REMPLACER LE PRODUIT ASA DISCRETION CONSTITUE LE SEUL RECOURS DE L ACHETEUR EN VERTU DE CETTE GARANTIE BROAN NUTONE NE PEUT PAS ETRE TENUE RESPONSABLE DE TOUT DOMMAGE INDIRECT CONSECUTIF OU ACCES SOIRE DECOULANT DE L UTILISATION OU DU RENDEMENT DU PRODUIT Certains Etats ou provinces interdisent l exclusion ou la restriction des dommages indirects ou cons cutifs La restriction susmentionn e peut donc ne pas s appliquer dans votre cas La pr sente garantie vous conf re des droits sp cifiques reconnus par la loi D autres droits pourraient galement vous tre accord s selon la l gislation locale en vigueur La pr sente garantie remplace toutes les autres garanties pr c dentes Pour le service sous garantie vous devez a aviser Broan NuTone l une des adresses ou num ros de t l phone mentionn s ci dessous b indiquer le num ro de mod le et d identification de la pi ce et c d crire la d fectuosit du produit ou de la pi ce Lors d une r clamation vous devez pr senter une preuve de la date d achat originale In USA Broan 926 W State Street Hartford WI 53027 800 558 1711 In Canada Broan 550 Lemire Blvd Drumm
6. box Replace with the same type of fuse 5x20mm 4A 125V WARRANTY ONE YEAR LIMITED WARRANTY FOR BROAN PRODUCTS Broan NuTone LLC Broan NuTone warrants to the original consumer purchaser of Broan products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCAN DESCENT BULBS FUSE FILTERS DUCTS ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCT ING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or instal lation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUT
7. phone indiqu s dans lagarantie Avant de pourvoir l entretien ou au nettoyage de votre appareil teignez le au tableau des commandes ou bloquez le tableau des commandes afin d viter de le mettre en marche accidentellement Si vous ne pouvez pas bloquer le syst me permettant d teindre votre appareil appliquez un avertissement ext rieur d une fa on sure comme par exemple un panneau surle tableau des commandes L assemblage etla connexion lectrique doivent tre faits par des personnes qualifi es enrespectantles normes et r glements en vigueur y compris les normes et r glements concernant les possibilit s d incendie llestindispensable qu il y ait suffisamment d air pour que la combustion etl vacuation des gaz travers le tuyau du br leur du combustible ait lieu sans retour de flamme Suivez les indications donn es parle fabricant du br leur ainsi que les normes de s curit comme celles qui sont publi es par Association Nationale pour la Protection contre les Incendies National Fire Protection Association NFPA etla American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE etles autorit s locales en matiere denormes Quand vous coupez ou percez des trous dans le mur ou le plafond n abimez pas les fils lectriques ou autres Le ventilateur canalis doit toujours vacuer l air vers l ext rieur l N utilisez pas cet appareil avec un appareil contr lant
8. rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks e For discolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth e For stubborn cases use a plastic scouring pad or soft bristle brush together with cleaser and water Rub lightly in direction of polishing lines or grain of the stainless finish Avoid using too much pressure which may mar the surface e DO NOT allow deposits to remain for long periods of time e DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust e DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after exposure and wipe dry with a clean cloth Painted surfaces should be cleaned with warm water and mild detergent only OPERATION Controls The hood is operated using the slide controls under the front edge of the hood The light switch turns the halogen lights on and off The blower on off switch turns the blower on to the running speed set by the blower speed control The blower must be turned on and off using this switch LIGHT BLOWER SWITCH BLOWER ON OFF The blower speed control changes the speed of the blower from 1 to 3 position T
9. 69 Switch Box Assembly Includes Keys No 222 223 226 225 224 228 229 230 165 166 Discharge Collar Assembly Includes Keys No 56 57 Fuse Fuse Holder 30 LISTE PIECES DE RECHANGE MODELE 61000 version 48 Ci dessous liste pieces de rechange pour hottes en inox Pour les pi ces de recharge des mod les de couleurs noir blanc laiton jaune poli cuivre bross contacter Broan Customer Service N PARTN DESCRIPTION B08087136 B02300233 BE3345326 B03295005 B02300891 B03292291 B02300787 B03294033 B03295001 BW0000072 B02310183 B03295071 B03204177 B02300249 B02011314 BE3341301 BE3341311 BE3300517 B03292287 B032920170 B032920180 BR2300132 BR2300135 B032920200 B03294781 B03295008 B08086668 BE3403629 B02300729 B03295035 B08091601 BE3345233 B02300789 B03295006 B08081196 B06001997 B06108054 B08092501 B02300782 B02300674 Illustr es separement Filtre anti graisse n 4 Condensateur Support boite installation electrique Bolte borne Lampe halogene Couvercle commandes Thermostat Heat Sentry Couvercle boite installation electrique Support filtre Convoyer Moteur Turbine du moteur Pare chocs Cable alimentation Plaquette logo Tube inf rieur Tube sup rieur Etrier montage tube Serre cable Boite cable alimentation Couvercle boite cable alimentation Borne Borne Serre cable Boite installation electrique Boite borne Borne Support sup rieur Tra
10. 9cm si la distancia entre la campana y la zona de cocci n es de 30 76cm INSTALACION DE LA CAMPA NA 1 Cuelgue la campana de los soportes por los agujeros rectangulares situados detras de la campana Los agujeros son mas grandes que los soportes para permitir el ajuste en horizontal La parte inferior de la campana debe estar a una distancia de 24 6 30 por encima de la zona de cocci n Los tornillos para la regulaci n de la altura permiten un ajuste en vertical Los tornillos para la regulaci n de la profundidad permiten un ajuste en horizontal Sujete la campana con tornillos de montaje 4 8x38mm Use escarpias si no dispone de tacos o de la estructura de soporte en madera Quitar la cinta adhesiva en la v lvula AGUJEROS TORNILLOS DE RECTANGULARES MONTAJE 4 8x38mm SOPORTES DE MONTAJE TORNILLOS DE MONTAJE 4 8x38mm ESTRUCTURA DE MADERA TORNILLOS PARA LA REGULACION DE LA PROFUNDIDAD TORNILLOS DE MONTAJE 4 8x38mm TORNILLOS PARA LA REGULACION DE LA ALTURA QUITAR LA CINTA DISTANCIA DE LA CAMPANA POR ENCIMA DE 36 SOBRE LA SUPERFICIE DE LA COCINA Techo 8 Techo 9 Techo 10 Tubos Standard Min 24 29 26 25 plus 30 INSTALACION ELECTRICA Nota Este tipo de campana tiene que ser conectada a tierra cuidadosamente La unidad debe instalarla un t cnico electricista si
11. BROAN Clic 7 61000 Series 48 versions AMO AAA 2 FRAN AIS 12 ESPANOL seess 22 In USA BROAN Hartford Wisconsin In CANADA BROAN Drummondville QC Canada REGISTER YOUR PRODUCT ONLINE AT www Broan com register For additional Information visit www Broan com READ AND SAVE THESE INSTRUCTIONS A INTENDED FOR DOMESTIC COOKING ONLY amp WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accor dance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equip ment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for
12. Drummondville QC J2C 7W9 866 737 7770 www Broan com SERVICE PARTS MODEL 61000 48 versions Parts for stainless steel models shown For service parts for black white polished brass or brushed copper models call Broan Customer Service KEY NO PART NO DESCRIPTION B08087136 B02300233 BE3345326 B03295005 B02300891 B03292291 B02300787 B03294033 B03295001 BW0000072 B02310183 B03295071 B03204177 B02300249 B02011314 BE3341301 BE3341311 BE3300517 B03292287 B032920170 B032920180 BR2300132 BR2300135 B032920200 B03294781 B03295008 B08086668 BE3403629 B02300729 B03295035 B08091601 BE3345233 B02300789 B03295006 B08081196 B06001997 B06108054 B08092501 B02300782 B02300674 Not shown assembled Grease Filter n 4 Motor Capacitor Electrical Box Support Transformer Protection Halogen Lamp Bulb Switch Cover Heat Sentry Electrical Box Cover Ductfree Filter Bracket Blower Motor Blower Wheel Rubber Washer Feeder Cable Nameplate Decorative Flue Bottom Decorative FlueTop Flue Mounting Bracket Wire Clamp Feeder Cable Connection Box Feeder Cable Connection Box Cover Junction Clamp Junction Clamp Electrical Box Wires Stop Electrical Box Junction Clamp Box Junction Clamp Upper Support Transformer Fuse Box Motor Support Connection Box Support Halogen Lamp Housing Transformer Protection Cover Hardware Package Blower Assembly Includes Key Nos 42 48 49 53 68
13. E 4 8x38mm SUPPORT DU CONDUIT FIXEZ LE TUYAU A LA HOTTE ET A L ETRIER AU MOYEN DES VIS D ASSEMBLAGE 3 9x9 5mm 9 18 CONDUIT DECORATIF a RUBAN POUR TUYAUTERIE TUYAU ROND EN METAL DE 8 ENTRETIEN Un bon entretien de votre hotte garantira une excellente performance Filtres anti graisse Les filtres anti graisse doivent tre nettoy s fr quemment Utilisez une solution contenant un d tergent tiede Les filtres anti graisse peuvent tre lav s au lave vaisselle Enlevez les filtres en les poussant vers Farriere de votre hotte et en les faisant tourner vers le bas Nettoyage de votre hotte L acier inoxydable est une des mati res les plus faciles a nettoyer Un entretien de temps en temps permettra de le conserver en parfait FILTRES ANTI GRAISSE tat Conseils pour le nettoyage Eau chaude et savon ou d tergent est tout ce qui est normalement n cessaire Apres chaque nettoyage rincez bien l eau claire Essuyez avec un chiffon propre et doux afin d viter les taches d eau Si des d colorations ou des d p ts persistent utilisez un nettoyant domestique non abrasif ou de la poudre pour l acier inoxydable et un peu d eau et un chiffon doux Dans les cas difficiles utilisez une ponge en plastique ou une brosse douce avec du nettoyant et de l eau Frottez l g rement en suivant la direction du polissage ou du gra
14. Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors Do not use this unit with any separate solid state speed control device To reduce the risk of fire use only metal ductwork This unit must be grounded O REDUCE THE RISKOF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe Dech ventilating fans frequently Grease should not be allowed to accumulate on fan or ilter Use proper pan size Always use cookware appropriate for the size of the surface element odo oo JO al Do W gt WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels violent steam explosion will resul
15. Los conductos ventiladores deben siempre desalojar al exterior No use esta unidad con dispositivo de control de la velocidad a estado s lido Para evitar el riesgo de incendio use solamente conductos de metal Esta unidad tiene que ser conectada a tierra oa ARA EVITAR EL RIESGO DE FUEGO POR ALTO NIVEL DE GRASA Nunca abandone los quemadores con el fuego alto La cocci n causa humo y restos de grasa que pueden arder Caliente el aceite a fuego medio o bajo Encienda siempre la campana cuando cocine a fuego alto o cuando cocine alimentos f cilmente inflamables por ejemplo Crepes Suzette Cerezas Jubilee Ternera flambeada con granos de pimienta Limpie con frecuencia los ventiladores No se debe acumular grasa en el ventilador o en el filtro Usa el tama p de cazuela apropiado Use siempre utensilios de cocina de tama o y material adecuados ADVERTENCIA PARA EVITAR EL RIESGO DE DANOS A PERSONAS EN CASO DE FUEGO POR ALTO NIVEL DE GRASA TENGA EN CUENTALO SIGUIENTE 1 SOFOQUE LA LLAMA con una tapadera apropiada una bandeja met lica 6 un utensilio de coc na que pueda cubrirla despues apague el quemador ACTUE CON PRECAUCION PARA EVITAR QUEMADURAS Si la llama no se extingue inmedia tamente SALGA Y LLAME A LOS BOMBEROS 2 NUNCA COJA UNA SARTEN EN LLAMAS porque corre el riesgo de quemarse 3 NO USE AGUA ni pa os o toallas h midas porque puede provocarse una violenta humareda 4 Use un extintor SOLA
16. MENTE si A Posee un extintor de clase ABC y sabe perfectamente c mo usarlo B Elfuego es peque o y est controlado en el mismo sitio en que empez C Hallamado con anterioridad a los bomberos D Puede combatir el fuego retroced endo hacia la salida Basado en Seguridad antifuego en la coc na publicado por NFPA BU OONO 29 ADVERTENCIA TA 10 11 Para uso en interiores Para reducir el riesgo de incendios y para evacuar correctamente los humos asegurarse de haber realizado una conducci n del aire hasta el exterior No expulsar los humos en espacios cerrados por paredes o techos ticos espacios angostos o garajes Prestar la m xima atenci n al utilizar productos de limpieza o detergentes Evitar el uso de productos alimentarios que puedan inflamarse bajo la campana S lo para ventilaci n total No use gases de escape peligrosos o materiales y vapores explosivos Para evitar da os en el funcionamiento del motor e impulsores ruidosos y o desequi librados mantenga alejados de la unidad de encendido pulverizadores en seco o polvo El motor tiene un nivel de sobrecarga t rmica que apaga autom ticamente el motor cuando se ha recalentado excesivamente El motor se pone de nuevo en fincionamento cuando la temperatura baja Si el motor comienza a encenderse y a apagarse deber hacer una revisi n de ste Para limpiar mejor las impurezas al cocinar la distancia entre la parte inferior de la cam
17. NuTone montaje incorrecto 6 instalaci n que no se ajuste a las instrucciones de montaje indicadas Le duraci n de la garant a se limita al periodo de un a o como est especificado en la garant a explicita Algunos paises no permiten un limite en la duraci n de la garant a implicita si es asi en su caso esta limitaci n arriba indicada podr a no aplicarse LA PRESENTE GARANTIA CUBRIRA EXCLUSIVAMENTE AL COMPRADOR LOS SERVICIOS DESCRITOS ANTERIORMENTE BROAN NUTONE NO SE HACE RESPONSABLE DE DANOS PRODUCIDOS DE MANERA ACCIDENTAL O RELACIONADOS CON EL USO INCORRECTO DEL PRODUCTO O SU FUNCIONAMIENTO Algunos paises no permiten la exclusi n o limitaci n de los da os producidos de manera accidental si es as en su caso esta limitaci n arriba indicada podr a no aplicarse Esta garant a le da derechos legales espec ficos y podr a tambi n disponer de otros derechos que varian de pa s a pa s Esta garant a supera otras garant as dadas con anterioridad Para disfrutar de la garant a usted deber a Avisar a la direcci n abajo indicada bien llamar por tel fono b Dar el n mero de serie del modelo correspondiente o bien una descripci n de la parte averiada c Descripci n del defecto en el producto o bien en una de sus partes Para requerir un servicio en garant a debe presentar el justificante con la fecha de la compra In USA Broan 926 W State Street Hartford WI 53027 800 558 1711 In Canada Broan 550 Lemire Blvd
18. ONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or con sequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address stated below or telephone number stated below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date In USA Broan 926 W State Street Hartford WI 53027 800 558 1711 In Canada Broan 550 Lemire Blvd Drummondville QC J2C 7W9 866 737 7770 www Broan com LISEZ ET CONSERVEZ CES INSTRUCTIONS SEULEMENT POUR UTILISATION DOMESTIQUE A AVERTISSEMENTS POUR REDUIRE LES RISQUES D INCENDIE DE DECHARGES ELECTRIQUES OU DE DOMMAGES AUX PERSONNES OBSERVEZ LES INSTRUCTIONS SUIVANTES 1 OOND Oo N utilisez cet appareil que comme cela est indiqu par le constructeur Si vous avez des probl mes contactez le fabriquant a Fadresse ou au num ro de t l
19. VOUS BRULER Si les flammes ne s teignent pas imm diatement SORTEZ ET APPELEZ LES POMPIERS NE PRENEZ JAMAIS EN MAIN UNE POELE OU UNE CASSEROLE QUI A PRIS FEU Vous pourriez vous br ler NUTILISEZ PAS D EAU ni torchons ou serviettes mouill s vous provoqueriez une violente explosion de vapeur 19 4 Utilisez un extincteur SEULEMENT si A Vous savez que vous avez un extincteur Classe ABC et vous en connaissez d ja le mode d emploi B Ce n est pas un tres gros incendie et qu il se limite endroi o il a explos C Vous tes en train d avertir les pompiers D Vous avez la possibilit d essayer d teindre l incendie en ayant le dos tourn vers une issue D apr s les Suggestions concernant la S curit contre les incendies des cuisines publi es par NFPA A ATTENTION 1 2 ako 10 11 Pour usage int rieur seulement Pour r duire tout risque d incendie et pour vacuer correctement l air assurez vous de pr voir un conduit de ventilation ext rieur Ne videz pas l air dans les espaces limit s par des murs ou des plafonds les combles les passages troits ou les garages Faites tres attention quand vous utilisez des produits de nettoyage ou des d tergents Evitez d utiliser des aliments pouvant s enflammer sous la Range Hood N utilisez cet appareil que pour une ventilation g n rale Ne Putilisez pas pour vacuer des mati res ou des vapeurs dangereuses ou qui peu
20. a a colocar el tubo de extracci n entre la campana y la parte exterior 2 Un recorrido de tubo corto y recto permitir a la campana funcionar de manera m s eficaz 3 Los recorridos largos de tubo codos y manguitos impiden el buen funcionamiento de la campana Use el menor n mero de ellos posible Para usos prolongados es necesario un tubo de evacuaci n del aire de mayor di metro 4 Instale una cubierta una tapa Una el tubo de metal a la cubierta y retroceda hasta la posici n de la campana Use une cinta para precintar las juntas entre las partes del entubado INSTALACION DE LOS SOPORTES PARA EL MONTAJE 1 Construya una estructura de madera en la pared que quedar nivelada con la parte interior de los tacos en la pared Aseg rese de que a La estructura se encuentra centrada por encima de la instalaci n del tubo b La altura de la estructura permite fijar los soportes para el montaje en esta estructura siguiendo las dimensiones indicadas 2 Una vez que la superficie de la pared est acabada sujete los soportes para el montaje siguiendo las dimensiones indicadas 2D5 CUBIERTA DEL TEJADO TUBO DECORATIVO CAMPANA SS MANGUITO 24 61cm A 30 76cm POR ENCIMA DE LA ZONA DE COCCION 8 20cm ADAPTADOR ESTRUCTURA DE MADERA EN LA PARED 29 7 8 75 9cm si la distancia entre la campana y la zona de cocci n es de 24 61cm 35 3 4 90
21. es si vous ne trouvez pas les vis passEMBLAGE pivot ou le cadre 4 8x38mm 4 Enlever le ruban positionn sur le clapet VIS DE REGLAGE EN HAUTEUR ENLEVER LE RUBAN ESPACEMENT ENTRE LA HOTTE ET LE PLAN DE CUISSON DE 36 DE HAUT Plafond 8 Plafond 9 Plafond 10 Conduit Standard Min 24 29 4 25 plus 30 16 INSTALLATION ELECTRIQUE Remarque Ce mod le de hotte doit tre reli la terre correctement Cet article devrait tre install par un lectricien qualifi selon les lois nationales et locales en mati re d lectricit INSTRUCTIONS POUR LA MISE A LA TERRE Cet appareil doit tre reli la terre En cas de court circuit la mise la terre r duit le risque de d charge lectrique en fournissant un c ble permettant au courant d tre d vi Cet appareil est quip d un cordon ayant un c ble de mise la terre avec une fiche de mise la terre La fiche doit tre branch e dans une prise de courant correctement install e et mise la terre 33 7 16 85cm max ATTENTION Une mise la terre incorrecte peut entra ner un risque de d charge lectrique Consulter un lectricien sp cialis si les instructions de mise a la terre ne sont pas tout fait compr hensibles ou en cas de doute sur le fait de savoir si l appareil est correctement reli a la terre Ne pas utiliser de prolongation Si le cordon d alimentation
22. est trop court demander a un lectricien agr d installer une prise de courant pr s de l appareil R gler l alimentation lectrique dans l espace couvert par le conduit d coratif Placer la prise femelle a une distance maximum de 33 7 16 85 cm de l endroit o le plomb sort de la hotte voir l illustration ci contre S assurer qu il n y ait pas d interf rence avec le conduit d coratif l endroit o la gaine touche le mur Mettre la fiche dans la prise femelle 17 CONNEXION DU SYSTEME D EVACUATION 1 Fixez l trier de support du conduit au plafond ou au mur au moyen des 2 vis 4 8x38mm et des chevilles comme cela est indiqu Reliez le collier d vacuation qui se trouve sur votre hotte au systeme de conduction qui se trouve au dessus au moyen d un tuyau rond en m tal de 8 20cm Utilisez un ruban pour tuyauterie afin de rendre toutes les jonctions sures et tanches Reliez le conduit d coratif sup rieur a F trier au moyen des vis d assemblage 3 9x9 5mm Faites glisser le conduit d coratif inf rieur vers le bas jusqu a ce qu il adh re correctement autour de la hotte Fixez le conduit d coratif inf rieur a votre hotte au moyen des vis d assemblage 3 9x9 5mm FIXATION AU MUR H LB Z w L wl I i VIS D ASSEMBLAGE 4 8x38mm ETRIER DE SUPPORT DU CONDUIT FIXATION AU PLAFOND VIS ETRIER DE D ASSEMBLAG
23. guiendo las normas nacionales y locales INSTRUCCIONES DE CONEXION A TIERRA Este aparato se debe conectar a tierra En caso de cortocircuito la conexi n a tierra reduce el riego de electrocuci n ya que posee un hilo de descarga a tierra para la corriente Este aparato est equipado con un cable que posee un hilo de toma de tierra con una clavija de tierra La clavija se debe conectar a un enchufe instalado correctamente y conectado a tierra 33 7 16 85cm max ADVERTENCIA una conexi n a tierra incorrecta puede provocar riesgos de electrocuci n Consulte a un electricista calificado si no se entienden o si existe alguna duda sobre la correcta conexi n a tierra No utilice un cable de prolongaci n Si el cable proporcionado es demasiado corto p ngase en contacto con un electricista calificado para que instale un enchufe cerca del aparato Conecte la alimentaci n el ctrica en el espacio cubierto por el tubo decorativo Coloque el enchufe a una distancia m xima de 33 7 16 85 cm desde el cable de la campana v ase figura adjunta Aseg rese de que no interfiera con el tubo decorativo donde el tubo decorativo toca con la pared Conecte la clavija al enchufe 27 ENTUBADO DE CANALIZACION 1 Use 2 tornillos 4 8x38mm y escarpias para fijar al techo o a la pared el soporte SUJECCION A LA PARED dl LP para el montaje del tubo como se i
24. he pilot lamp lights up whenever the blower is on HEATSENTRY Your hood is equipped with a HEAT SENTRY thermostat This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface 1 If blower is OFF it turns blower ON to HIGH speed 2 If blower is ON at a lower speed setting it turns blower up to HIGH speed When the temperature level drops to normal the blower will return to its original setting WARNING The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF When this occurs it is impossible to turn the blower OFF with its switch If you must stop the blower do it from the main electrical panel HALOGEN BULBS This range hood requires 4 halogen bulbs Type T3 12V 20W G 4 Base ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE To change bulbs 1 Loosen the ring nut by turning it counterclockwise 2 Pull the bulb downwards to remove DO NOT ROTATE CAUTION BULB MAY BE HOT 3 Replace with Type T3 12V 20W G 4 Base halogen bulb Do not touch replacement bulb with bare hands S f Sc us e S SA AJ a 8 RS DEZ Ee RING NUT 10 FUSE REPLACEMENT SWITCH OFF THE ELECTRICITY SUPPLY FUSE ELECTRICAL BOX Remove the grease filters SUPPORT Remove the electrical box support and open the fuse
25. ically To reduce the risk of injury and to prevent power from being switched on accidentally switch power off at service panel and lock or tag service panel Please read specification label on product for further information and requirements PREPARE THE HOOD Unpack hood and check contents You should receive 1 Hood 1 Decorative Flue Assembly 1 Flue Mounting Bracket 1 Parts Bag B08081196 containing 2 Mounting Brackets 10 Mounting Screws 4 8 x 38mm Pan Head 4 Mounting Screws 3 9 x 9 5mm Pan Head 4 Mounting Screws 3 9 x 9 5mm Pan Head Black 10 Drywall Anchors 1 Installation Instructions DECORATIVE SES MOUNTING BRACKETS 4 MOUNTING SCREWS 3 9 x 9 5mm Pan Head 4 MOUNTING SCREWS 3 9 x 9 5mm Pan Head Black FLUE MOUNTING BRACKET 10 MOUNTING SCREWS 10 DRYWALL 4 8 x 38mm Pan Head ANCHORS INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 2 3 Decide where the ductwork will run between the hood and the outside A straight short duct run will allow the hood to perform most efficiently Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible Larger ducting may be required for best performance with longer duct runs Install a roof or wall cap Connect round metal ductwork to cap and work back to wards hood location Use duct tape to seal the joints bet
26. in de Facier inoxydable Evitez de frotter trop fort afin de ne pas abimer la surface NE LAISSEZ PAS les taches trop longtemps N UTILISEZ PAS de laines d acier ordinaires ou des brosses en acier Des d bris d acier pourraient adh rer a la surface et causer de la rouille NE PERMETTEZ PAS que des solutions sal es des d sinfectants des blanchissants ou des produits nettoyants restent en contact avec l acier pendant longtemps Beaucoup de ces produits contiennent des produits chimiques qui pourraient causer des dommages Rincez l eau imm diatement s ils entrent en contact et essuyez avec un chiffon humide Les surfaces peintes doivent tre nettoy es avec de l eau ti de additionn e d un d tergent doux seulement 19 FONCTIONNEMENT Commandes INTERRUPTEUR DE LA INTERRUPTEUR ON Votre hotte fonctionne grace a des interrupteurs asie OE R que vous faites glisser sur le devant de votre hotte L interrupteur de la lumiere allume et teint les lampes halogenes L interrupteur ON OFF du ventilateur fait fonctionner le ventilateur a la vitesse tablie par le bouton r glant la vitesse Le ventilateur est mis en marche et arr t au moyen de cet interrupteur Le bouton r glant la vitesse s lectionne les diff rentes vitesses du moteur de 1 a 3 Le voyant lumineux s allume quand le ventilateur fonctionne BOUTON R GLANT LA VITESSE DU VENTILATEUR VOYANT LUMINEUX HEAT SENTRY C Vot
27. la hauteur du cadre permettra que les triers d assemblage soient fix s au cadre en respectant les dimensions indiqu es Apr s avoir termin la surface du mur fixez les triers d assemblage au cadre en respectant les dimensions qui sont indiqu es s15 COUVERCLE DU TOIT CONDUIT DECORATIF i St HOTTE DE 24 61cm A 30 76cm AU DESSUS DU PLAN DE CUISSON 8 20cm ADAPTATEUR CADRE POUR LE MUR 29 7 8 75 9cm si la distance entre la hotte et le plan de cuisson c est de 24 61cm 35 3 4 90 9cm si la distance entre la hotte et e plan de cuisson c est de 30 76cm INSTALLATION DE LA HOTTE VIS D ASSEMBLAGE TROUS _ _ _ _ _ _ _ _ _ ___ __ _ _ 4 8x38mm RECTANGULAIRES 1 Accrochez votre hotte aux triers par les RL trous rectangulaires qui se trouvent Po ETRIERS derriere votre hotte Les trous sont plus lt D ASSEMBLAGE grands que les triers afin de vous permettre d ajuster le tout horizontalement Le fond de votre hotte devrait tre a entre 24 et 30 au dessus de la surface de cuisson 2 Les vis de r glage en hauteur permettent de r gler verticalement vis 3 Les vis de r glage en profondeur D ASSEMBLAGE Ree permettent de r gler horizontalement BRM 4 Fixez votre hotte avec des vis d assemblage 4 8x38mm Utilisez des NE HOLOMDEUE chevilles pour mur a sec qui vous sont m fourni
28. la vitesse a tat solide Afin de diminuer tout risque d incendie n utilisez que des conduits en m tal Votre appareil doit tre reli la terre ATTENTION POUR REDUIRE LES RISQUES D INCENDIE DES MATIERES GRASSES QUI SONT EN TRAIN DE CUIRE A Ne laissez jamais ni vos l ments chauffants ni vos casseroles ou po les sur le feu sans les contr ler si vous r glez l apport de chaleur sur une position lev e Si vos casseroles ou po les d bordent cela provoque de la vapeur et des claboussures de graisse qui peuvent prendre feu Chauffez les huiles lentement a feu bas ou moyen Faites toujours fonctionner votre hotte quand vous cuisez des temp ratures lev es ou quand vous cuisinez des plats flamb s par ex cr pes Suzette Cerises Jubil Steack au poivre flamb Nettoyez r guli rement les ailes de vos ventilateurs Ne permettez pas que la graisse s accumule sur le ventilateur ou sur le filtre Utilisez des casseroles de taille appropri e Utilisez toujours des ustensiles de cuisson dont la taille est appropri e la surface de votre l ment de cuisson AVERTISSEMENTS POUR REDUIRE LES RISQUES DE DOMMAGES AUX PERSONNES AU CAS O VOTRE CUISINI RE PRENDRAIT FEU OBSERVEZLES INSTRUCTIONS SUIVANTES 1 ETEINDRE LES FLAMMES l aide d un couvercle le plus herm tique possible une plaque g teaux ou un plateau en m tal puis teindre le br leur ATTENTION NE PAS
29. mblage 10 Vis d assemblage 4 8 x 38mm T te ronde 4 Vis d assemblage 3 9 x 9 5mm T te ronde 4 Vis d assemblage 3 9 x 9 5mm T te ronde Noir 10 Chevilles 1 Instructions pour l installation CONDUIT DECORATIVE ETRIERS D ASSEMBLAGE 4 VIS D ASSEMBLAGE 3 9 x 9 5mm T te ronde A E 4 VIS D ASSEMBLAGE 3 9 x 9 5mm T te ronde Noir ETRIER DE SUPPORT 10 VIS DASSEMBLAGE 10 CHEVILLES 4 8 x 38mm T te ronde 14 INSTALLATION DU SYSTEME D EVACUATION REMARQUE Pour r duire les risques d incendie n utilisez que des tuyaux en m tal 1 2 Un tuyau lon D cidez ou le tuyau doit tre install entre votre hotte et l ext rieur Un tuyau droit et court permettra a votre hotte de fonctionner d une facon plus efficace avec des coudes et des transitions r duira le bon fonctionnement de votre hotte En utiliser le moins possible Pour de longues utilisations il faut un tuyau d vacuation d air ayant un diam tre plus large Installez un couvercle sur le toit ou au mur Reliez un tuyau en m tal rond au couvercle et faites le aller jusqu a emplacement de votre hotte Rendez les jonctions du tuyau herm tiques au moyen d un ruban pour tuyaux INSTALLATION DES ETRIERS D ASSEMBLAGE 1 Construisez un cadre en bois pour le mur 2 dont les vis pivot ne d passent pas Assurez vous a que le cadre est centr au dessus de l emplacement de l installation b
30. nas El mando de encendido y apagado del aspirador pone ste en posici n de encendido junto con el control de la velocidad El control de velocidad del aspirador cambia la velocidad dal aspirador entre las posiciones 1y3 El piloto se enciende cuando el aspirador est funcionando ASPIRADOR PILOTO HEAT SENTRY Su campana esta equipada con termostato HEAT SENTRYYC Este termostato tiene un mecanismo que se encender o acelerat el ventilador si se detecta un calor excesivo encima de la cocina 1 Si el ventilador esta apagando el se prender a una velocidad m xima 2 Si el ventilador esta encendido a una velocidad minima el se prender a una velocidad m xima Cuando la temperatura disminuye a un nivel normal el ventilador vuelve a la funci n de origen AVERTENCIA El HEAT SENTRY termostato puede comenzar a funcionar al igual si la campana esta parada En este caso es imposible parar el ventilador con los interruptores Si usted para la campana halago a partir del panel el ctrico principal LAMPARAS HALOGENAS Este tipo de campana necesita 4 l mparas hal genas Tipo T3 12V 20W G 4 Base ANTES DE PROCEDER A CUALQUIER OPERACI N ES NECESARIO DESCO NECTAR EL APARATO Para cambiar las l mparas 1 Destornillar la abrazadera en sentido antihorario 2 Extraiga la l mpara oblicuamente NO LA GIRE ATENCION LAS LAMPARAS PUEDEN ESTAR CALIENTES 3 Sustituir con l mparas del tipo
31. ndica s 2 Use un tubo de metal de 8 20cm de wt diametro para unir el casquillo que se encuentra encima de la campana al tubo TORNILLOS de extracci n situado arriba DE MONTAJE 3 Use cinta para ajustar todas las junturas y 4 8x38mm SOPORTE PARA que quede herm tico EL Nee DEL 4 Una el tubo decorativo superior al soporte con los tornillos de montaje 3 9x9 5mm 5 Deslice el tubo decorativo inferior hacia SUJECCION AL TECHO abajo hasta que ajuste perfectamente con la campana 6 Sujete el tubo decorativo inferior a la campana por medio de los tornillos de montaje 3 9x9 5mm DE montaje SOPORTE PARA 4 8x38mm EL MONTAJE DEL TUBO SUJETE EL TUBO A LA CAMPANA Y ALA ABRAZADERA CON TORNILLOS DE MONTAJE TUBO 3 9X9 5MM DECORATIVO P CINTA TUBO DE METAL DE 8 DE DIAMETRO 28 MANTENIMIENTO Un mantenimiento adecuado de la campana asegura el funcionamiento correcto del aparato Filtros antigrasa Los filtros antigrasa deben limpiarse a menudo Use un detergente que no sea fuerte Los filtros antigrasa se pueden meter en el lavavajillas Extraiga los filtros tirando de ellos hacia atras FILTROS ANTIGRASA de la campana y girandolos hacia abajo Limpieza de la campana El acero inoxidable es uno de los meteriales mas faciles de limpiar pero seria aconsejable un especial cuidado en su uso para mantenerla en buen estado La campana se puede limpiar de las siguie
32. ntes maneras Agua caliente con jab n o detergente es la mejor manera para limpiarla Acl rela con agua corriente s quela con un pa o suave y limpio para evitar las huellas que deja el agua Para las manchas o restos de grasa que persistan use un producto qu mico dom stico que no raye un limpiador para acero inoxidable con poca agua y un pa o suave Si las manchas persisten use un estropajo y un cepillo de cerdas suaves con un producto limpiador y agua Frote suavemente en el sentido del pulido o de las vetas del remate del inoxidable No apriete demasiado porque podr a da ar la superficie No deje que las manchas se acumulen durante mucho tiempo No use utensilios o cepillos de acero Peque as particulas de acero pueden adherirse y oxidarse No use soluciones salinas desinfectantes lej as o productos de limpieza que permanezcan en contacto con el acero inoxidable durante largos periodos de tiempo Muchos de estos productos contienen componentes qu micos que podr an resultar nocivos Aclare con agua y seque con un pa o limpio Las superficies lacadas deben limpiarse solamente con agua tibia y detergente no muy fuerte 29 FUNCIONAMIENTO Mandos INTERRUPTOR MANDO DE La campana se pone en funcionamiento DA LUZ APAGADO usando los mandos situados abajo de la parte CONTROL DE LA DEL VELOCIDAD DEL ASPIRADOR frontal de la campana El interruptor sa luz enciende y apaga las l mparas hal ge
33. ondville QC J2C 7W9 866 737 7770 www Broan com LEA Y CONSERVE ESTAS INSTRUCCIONES INDICADO PARA EL USO EN COCINAS DOMESTICAS ADVERTENCIA PARA EVITAR EL RIESGO DE INCENDIO CORTOCIRCUITO O DANO PARA LAS PERSONAS OBSERVE ATENTAMENTE LAS SIGUIENTES NORMAS 1 Use esta unidad solamente de la manera indicada por el fabricante si tiene dudas p ngase en contacto con ste a la direcci n o tel fono indicados en la garant a 2 Antes de hacer una revisi n o de limpiar la unidad descon ctela de la red para evitar que se encienda de manera accidental En el caso de que ste no pueda ser desacti vado se indicar nel panel de servicio 3 El montaje y la instalaci n el ctrica debe hacerlos un t cnico especializado siguiendo las normas est ndar e incluyendo aquellas de construcci n anti incendio 4 Necesita aire suficiente para una apropiada combusti n y escape de gases a trav s del tubo del dep sito de quema de combustible Para evitar que el humo aspirado vuelva a la cocina siga las directivas del fabricante y las normas est ndar de siguridad as como las normas publicadas por la Asociaci n de prevenci n de incendios NFPA y la Socie dad americana de especialistas en cale facci n refrigeraci n y aire acondicionado y adem s las normas de las autoridades locales Hacer un corte o un taladro en la pared o en el techo no debe da ar la instalaci n el ctrica u otras instalaciones ocultas en la pared
34. pana y la zona de cocci n debe ser m nimo 24 maximo 30 Debido a su gran tama o y peso se recomienda su montaje por parte de dos t cnicos esperializados Este producto est dotado de un termostato que pone en marcha autom ticamente el motor Para reducir el riesgo de da os y evitar que se encienda accidentalmente colocar el interruptor del panel de servicio en la posici n OFF y bloquear el panel de servizio o colocar una advertencia externa como por ejemplo un letrero o una chapita Se recomienda leer la placa de caracteristicas del producto para ulterior informaci n 23 PREPARE LA CAMPANA Sacar la campana de l embalaje y controlar el contenido Recivireis 1 Campana 1 Tubo decorativo 1 Soporte para el montaje del tubo 1 Bolsita B08081196 con 2 Soportes de montaje 10 Tornillos de montaje 4 8 x 38mm cabeza redonda 4 Tornillos de montaje 3 9 x 9 5mm cabeza redonda 4 Tornillos de montaje 3 9 x 9 5mm cabeza redonda negra 10 Escarpias 1 Instrucciones para instalaci n TUBO DECORATIVO SOPORTES DE MONTAJE 4 TORNILLOS DE MONTAJE y 3 9 x 9 5mm cabeza redonda 4 TORNILLOS DE MONTAJE El 3 9 x 9 5mm cabeza redonda negra SOPORTE PARA EL MONTAJE DEL TUBO 10 TORNILLOS DE 10 ESCARPIAS MONTAJE 4 8 x 38mm cabeza oda 24 INSTALACION DEL TUBO DE EXTRACCION NOTA para evitar el riesgo de incendio use solamente material de metal 1 Decida donde v
35. re hotte est munie d un thermostat HEAT SENTRY C Ce thermostat est un dispositif qui actionnera ou augmentera la vitesse du ventilateur s il d tecte une chaleur excessive au dessus de la surface de cuisson 1 Si le ventilateur n est pas en marche il actionnera le ventilateur en haute vitesse 2 Si le ventilateur fonctionne en basse vitesse le ventilateur tournera en haute vitesse Lorsque la temp rature revient la normale le ventilateur retourne sa vitesse d origine AVERTISSEMENT Le thermostat HEAT SENTRY peu actionner la hotte m me si la hotte est arr t e Si tel est le cas il est impossible de l arr ter avec l interrupteur Si vous devez arr ter le ventilateur faites le partir du panneau lectrique principal AMPOULES HALOGENES Ce mod le de hotte veut 4 ampoules halog nes Type T3 12V 20W G 4 Base AVANT DE PROCEDER A QUELCONQUE OPERATION DEBRANCHEZ L APPAREIL Pour changer les ampoules 1 D vissez la bague dans le sens contraire aux aiguilles d une montre 2 Enlevez l ampoule en tirant sur le c t NE LA FAITES PAS TOURNER ATTENTION L AMPOULE PEUT ETRE CHAUDE 3 Remplacer par une ampoule ayant les m mes caract ristiques Type T3 12V 20W G 4 Base Ne touchez pas l ampoule neuve de vos mains nues 20 FUSIBLE SUPPORT BOITER INSTALLATION ELECTRIQUE REMPLACEMENT FUSIBLE D BRANCHEZ L APPAREIL Enlevez les filtres anti graisse D monte
36. sformateur Boite fusible Support moteur Support boite installation electrique Bo te lampe halog ne Couvercle de la protection trasformateur Accessoires de fixation Ensemble moteur Comprenant n 42 48 49 53 68 69 Ensemble commandes Comprenant n 222 223 226 225 224 228 229 230 165 166 Ensemble collier d vacuation Comprenant n 56 57 Fusible Porte fusible 33 LISTA DE PIEZAS DE RECAMBIO MODELO 61000 version 48 Aqui aparecen solamente las piezas de recambio para campanas de acero inoxidable si desean las piezas de recambio de los modelos en blanco negro lat n lustrado 6 cobre acepillado p nganse en contacto con el servicio al cliente de Broan C D N Se encuentran por separado PIEZA N B08087136 B02300233 BE3345326 B03295005 B02300891 B03292291 B02300787 B03294033 B03295001 BW0000072 B02310183 B03295071 B03204177 B02300249 B02011314 BE3341301 BE3341311 BE3300517 B03292287 B032920170 B032920180 BR2300132 BR2300135 B032920200 B03294781 B03295008 B08086668 BE3403629 B02300729 B03295035 B08091601 BE3345233 B02300789 B03295006 B08081196 B06001997 B06108054 B08092501 B02300782 B02300674 DESCRIPCI N Filtro antigrasa n 4 Condensador Soporte de la caja de instalaci n el ctrica Caja del cuadro el ctrico L mpara hal gena Tapa de la caja de mandos Termostato Heat Sentry Tapa de la caja de instalaci n el ctrica Soporte filtro
37. t 4 Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA 2 A CAUTION 1 2 NRO 9 10 11 For indoor use only To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages Take care when using cleaning agents or detergents Avoid using food products that produce flames under the Range Hood For general ventilating use only Do not use to exhaust hazardous or explosive materi als and vapors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced For best capture of cooking impurities the bottom of the hood should be a minimum of 24 and a maximum of 30 above the cooking surface Two installers are recommended because of the large size and weight of this hood This product is equipped with a thermostat which may start blower automat
38. vent exploser Pour viter de causer des dommages au moteur et de rendre les rotors bruyants et ou non quilibr s vitez que les sprays pour murs secs la poussi re de construction entrent en contact avec la partie lectrique Le moteur de votre hotte a un thermostat qui teindra automatiquement le moteur s il est surchauff Le moteur se remettra en marche lorsqu il se sera refroidi Si le moteur continue a s teindre et a se remettre en marche faites v rifier votre hotte Pour mieux capturer les impuret s de cuisine le bas de votre hotte devrait tre une distance minimum de 24 et a une distance maximum de 30 au dessus du plan de cuisson Vu que cette hotte est grande et lourde il est recommand de confier l installation de cette hotte a deux personnes Ce produit est dot d un thermostat qui active automatiquement le moteur Pour r duire le risque de dommages et viter l activation accidentelle positionner l interrupteur du panneau de service sur la position OFF et bloquer le panneau de service ou mettre un avertissement externe par exemple une plaquette Nous vous recommandons de lire l tiquette indiquant les caract ristiques de votre hotte pour de plus amples informations et exigences 13 PREPAREZ LA HOTTE Enlever la hotte dans Femballage et controller le contenu Vous devez recevoir 1 Hotte 1 Conduit d coratif 1 trier de support 1 Sachet B08081196 avec 2 triers d asse
39. ween ductwork sections INSTALL MOUNTING BRACKETS 1 Construct wood wall framing that is flush with interior surface of wall studs Make sure a the framing is centered over installation location b the height of the framing will allow the mounting brackets to be secured to the framing within the dimensions shown After wall surface is finished secure mount ing brackets to framing using dimensions shown ROOF CAP 24 TO 30 ABOVE COOKING SURFACE 29 7 8 bottom of hood 24 above 35 3 4 bottom of hood 30 above cooktop cooktop INSTALL THE HOOD MOUNTING SCREWS RECTANGULAR T gt gt T T CUTOUTS 1 Hang the hood from the brackets through M the rectangular cut outs on the back of eee the hood Cut outs are larger than the brackets to allow for horizontal adjustment The bottom of the hood should be 24 to 30 above the cooking surface 2 Height adjustment screws provide vertical adjustment 3 Depth adjustment screws provide hori MOUNTING zontal adjustment MOG WALL FRAMING 4 Secure the hood with mounting screws 4 8x38mm 4 8x38mm Use drywall anchors provided if wall studs or framing are not DEPTH ADJUSTMENT available SCREWS 5 Remove the tape located on the damper MOUNTING SCREWS 4 8x38mm HEIGHT ADJUSTMENT SCREWS REMOVE THE TAPE HOOD DISTANCE ABOVE 36 HIGH COOK TOP
40. z le support bo tier installation lectrique et ouvrir le boitier fusible Remplacez par un fusible du m me type 5x20mm 4A 125V BO TER FUSIBLE GARANTIE GARANTIE LIMIT E DE UN AN DE BROAN Broan NuTone LLC Broan NuTone garantit l acheteur original que les produits BROAN vendus en vertu de la pr sente sont libres de tout vice de mat riau ou de fabrication pour une p riode de un an a compter de la date d achat originale CETTE GARANTIE NE COMPORTE AUCUNE AUTRE GARANTIE EXPRESSE OU TACITE Y COMPRIS MAIS SANS S Y LIMITER LES GARANTIES TACITES DE VALEUR MARCHANDE OU D ADAPTATION A UN USAGE PARTICULIER Durant cette p riode de un an Broan NuTone r parera ou remplacera gratuitement sa discr tion tout produit ou toute pi ce jug s d fectueux dans des conditions normales d utilisation CETTE GARANTIE NE S APPLIQUE PAS AUX TUBES FLUORESCENTS ET AUX STARTERS NI AUX AMPOULES HALOGENES OU INCANDESCENTES FUSIBLE FILTRES CONDUITES CHAPEAUX DE TOIT CHAPEAUX DE MUR ET AUTRES ACCESSOIRES POUR CANALISATIONS Cette garantie ne couvre pas a les frais d entretien ou de service normaux ni b tout produit ou toute pi ce soumis a une utilisation inad quate une n gligence un accident un entretien ou une r paration inad quats autres que ceux effectu s par Broan NuTone une mauvaise installation ou une installation contraire aux instructions recommand es S La dur e de toute garantie tacite est limit e
Download Pdf Manuals
Related Search
Related Contents
Quick Start Guide for H.264 Cameras ficha - Kin Cosmetics Apple ZM034-4845-A User's Manual Eurofase 23126-039 Installation Guide TSSBTRWA21-033 - Sunbeam® Canada DATA CENTER 3.2 説明書 Copyright © All rights reserved.
Failed to retrieve file