1. SEMI CIRCULAR DUCT KNOCKOUT Remove for 7 Round Discharge REAR RECTANGULAR DUCT KNOCKOUT Remove for 314 x 10 Horizontal Discharge Remove appropriate Duct Knockout s from top or back of hood TOP BACK UP TO 1 TAPE EDGE SIDE TO SIDE ADJUSTMENT et DAMPER DUCT E CONNECTOR 3 Vertical discharge position shown 314 x 10 Ducted Discharge Only Attach Damper Duct Connector over knockout opening Make sure damper Pivot is nearest to Top Back Edge of hood Remove Tape from damper flap 7 Round Ducted Discharge Only Re install 7 Round Duct Plate removed in Step 1 under PREPARE THE HOOD section Install a 7 round damper purchase separately Damper flap must open freely in direction of air flow away from range hood To accomodate off center ductwork the Damper Duct Connector can be installed up to 1 inch on either side of hood center or the 7 Round Duct Plate can be installed up to Y on either side of hood center In extreme off center installations one end of the duct connector may need to be trimmed to clear the electrical cable clamp Page 4 CONNECT WIRING WARNING To reduce the risk of electric shock make sure power is switched off at the service panel Lock or tag service panel to prevent power from being switched on accidentally HOUSE WIRING 120 VAC CARDBOARD Use to protect cooktop Connect House Wiring 120 VAC to hood Use
2. Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA OOD CAUTION A 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 For best capture of cooking impurities your range hood should be mounted so that the top of the hood is 24 30 above the cooking surface 5 Please read specification label on product for further information and requirements Installer Leave this manual with the homeowner Homeowner Operating and Cleaning information on page 5 NOTE If hood is to be installed Non Ducted Purchase a set of 2 non ducted filters from your local distributor or retailer and attach them to the aluminum mesh filters TABLE OF CONTENTS This manual is divided into sections as follows PREPARE HOOD LOCATION Run ductwork from roof or wall cap and electrical wiring from service panel to installation location PREPARE THE HOOD Get your hood ready for installation CONNECT WIRING Make electrical wiring connections
3. Black for 30 Hood Light Panel Black for 36 Hood Light Panel Black for 42 Hood Light Panel Stainless for 30 Hood Light Panel Stainless for 36 Hood Light Panel Stainless for 42 Hood Light Panel Biscuit for 30 Hood Light Panel Biscuit for 36 Hood Light Panel Biscuit for 42 Hood Indicator Light includes 2 wire nuts and lens Light Diode Assembly includes wire nut Wire Harness Non Ducted Filter Kit 30 2 per bag Non Ducted Filter Kit 36 2 per bag Non Ducted Filter Kit 42 2 per bag WARRANTY NUTONE ONE YEAR LIMITED WARRANTY NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WAR RANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident Order replacement parts by PART NO not by KEY NO Standard hardware may be purchased locall
4. Nulone CAMPANA EXTRACTORA SERIE WS1 ALLURE CAMPANA EXTRACTORA SERIE WS1 ALLURE Pagina 7 Patent No AD EEE US D450 829 S A PARA COCINAR DOMESTICO SOLAMENTE A ADVERTENCIA A IN PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE ELECTRICO O LESION A PERSONAS PROCURE LO SIGUIENTE 1 Utilice esta unidad s lo en la manera prescrita por el fabricante Si tiene usted alguna pregunta comun quese con el fabricante a la direcci n o el tel fono indicados en la garant a 2 Antes de efectuar alg n servicio o limpieza se debe desconectar la corriente el ctrica en el armario de circuitos y asegurarlo con llave para evitar que la corriente sea conectada accidentalmente Cuando no se puedan inmovilizar los medios de desconexi n de servicio pegue con seguridad un dispositivo de advertencia prominente tal como una etiqueta en el tablero de servicio 3 Todo trabajo de instalaci n y cableado el ctrico debe ser realizado por per sonal calificado y de acuerdo con todos los c digos y normas pertinentes incluyendo los c digos y normas relacionados con construcci n clasificada para incendio 4 Aire suficiente es necesario para facilitar la combusti n adecuada y la salida apropiada de gases por la chimenea de la unidad y para evitar corrientes de aire invertidas Siga las instrucciones y medidas de segurid
5. cap or wall cap For best results use a unimu number of transitons and elbows PREPARE TH E HOOD Use diagrams below for proper placement of ductwork and electrical cutout in cabinet or wall For a non ducted installa tion DO NOT cut a duct access hole 7 ROUND 3 X 10 DUCT PLATE HOOD MOUNTING SCREWS 4 VERTICAL DUCTING 13 6 30 hood 1615 16 36 hood 13116 30 hood 1915 16 42 hood 1615 16 36 hood CABINET FRONT 19196 42 hood 71 O CABINET BOTTOM Ue gt 51 5M AN VERTICAL DUCT 2 a 0 Fi e ell gt e 1 WwW t WOOD SHIMS ra Remove 7 Round Duct Plate from top of hood Set duct recessed bottom nE in cabinet bottom plate aside with mounting screws cabinets only WOOD SHIMS 3 X 10 recessed bottom HORIZONTAL DUCTING FILTERS cabinets only CABINET FRONT l a a YE calm Jt ACCESS HOLE 51 72 1315 16 30 hood 1615 16 36 hood 1915 46 42 hood 334 CABINET BOTTOM 5 1315 46 30 hood 1615 46 36 hood 1915 46 42 hood Remove tape holding Filters in place Pull down on filter HOOD MOUNTING CENTER ELECTRICAL tabs and lift filters out Set filters aside SCREWS 4 LINE ACCESS HOLE in wall Nulone ALLURE WS1 SERIES RANGE HOOD PREPARE THE HOOD Remove Damper Duct Connector from inside the hood Set connec tor aside with mounting screws and parts bag D
6. motor est permanentemente lubricado No lubrique ni desmonte el motor CAMPANA EXTRACTORA SERIE WS1 ALLURE Nulone PIEZAS DE SERVICIO CLAVE NO PIEZA NO Pagina 12 DESCRIPCION R680508 R740013 R602017 R561115 R561116 R561117 R561119 R627518 R627519 R627520 R627533 R627579 R607657 R602534 R602533 R680504 R169016 R169002 R99080535 R401647 R401646 R531075 R99420635 99010299 99010300 99010301 R111630 R7201731 R7201751 R7201771 R7201732 R7201752 R7201772 R7201734 R7201754 R7201774 R720174 R720176 R720178 R7201735 R7201755 R7201775 R169004 R169010 R111626 99010308 99010309 99010310 Placa para conducto redondo de 17 8 cm incluye herraje Conector de regulador de tiro conducto incluye herraje Tornillo 8 18 x 1 4 hexagonal 2 en el paquete Interruptor oscilante color almendra 2 en el paquete Interruptor oscilante color blanco 2 en el paquete Interruptor oscilante color negro 2 en el paquete Interruptor oscilante cer mica 2 en el paquete Placa de identificaci n color blanco Placa de identificaci n color almendra Placa de identificaci n inoxidable Placa de identificaci n cer mica Placa de identificaci n color negro Lentes Tornillo 8 18 x 3 8 2 en el paquete Tornillo de conexi n a tierra Cubierta para la conexi n el ctrica incluye herraje Remache 125 d a Juego de resorte de filtro Tornillo de montaje del motor 3 cada pieza Motor incluye ju
7. necesitar ser cortado al claro la grapa para cable el ctrico PARA CONDUCTO SEMI descargas con conductos P gina 10 CONEXI N EL CTRICA da ADVERTENCIA Para reducir el riesgo de descar gas el ctricas aseg rese de apagar el interruptor de alimentaci n el ctrica en el panel de servicio Bloquee o rotule el panel de servicio para evitar que alguien conecte accidentalmente la energ a el ctrica CABLEADO DOM STICO 120 VCA CART N Para proteger la superficie de la estufa Haga la conexi n el ctrica del suministro dom stico 120 VCA en la campana Si es necesario use un pedazo de cart n para proteger la superficie de la estufa TORNILLO VERDE DE CONEXION A TIERRA Pr a Conecte el cable negro del suministro dom stico con el cable negro de la campana el cable blanco del suministro dom stico con el cable blanco de la campana y la conexi n a tierra del suministro dom stico debajo del tornillo verde de conexi n a tierra Apriete fijamente una grapa para cable el ctrico a cableado dom stico Vuelva a instalar la cubierta de la conexi n el ctrica Nulone CAMPANA EXTRACTORA SERIE WS1 ALLURE INSTALACION DE LA CAMPANA ORIFICIO TIPO BA CALLAVE 4 TORNILLO e DE e MONTAJE 4 Cuelgue la campana de los 4 orificios de montaje que se encuentran en la bolsa de piezas Deslice la campana hacia la pared hasta que los orificios de montaje queden co
8. the fan The left position is low speed center position is off and right position is high speed An indicator light shows that the fan is on Light The 3 position rocker switch on the right controls the lights The left position is low light intensity center position is off and right position is high light intensity CLEANING WARNING To reduce the risk of electric shock disconnect from power supply before cleaning Aluminum mesh filters Clean frequently using hot water and a mild detergent Filters are dishwasher safe Charcoal filters Clean filter surfaces frequently with a damp cloth and a mild detergent DO NOT immerse filters in water or put in dish washer The special Clean Sense feature indicates when the filter is to be replaced The dotted lines on the indicator strip will change to solid wide lines when it is time to change the filter The Clean Sense feature works best when facing toward the cooking surface To clean hood Remove filters Use a damp cloth and a mild deter gent to wipe all grease laden surfaces Use care when cleaning fan blade it must not become bent or misaligned DO NOT ALLOW WATER TO ENTER MOTOR Make sure all surfaces are completely dry before re installing filters and restoring power Motor is permanently lubricated Do not oil or disassemble motor ALLURE WS1 SERIES RANGE HOOD Nulone SERVICE PARTS Page 6 DESCRIPTION R680508 R740013 R602017 R561115 R561
9. 116 R561117 R561119 R627518 R627519 R627520 R627533 R627579 R607657 R602534 R602533 R680504 R169016 R169002 R99080535 R401647 R401646 R531075 R99420635 99010299 99010300 99010301 R111630 R7201731 R7201751 R7201771 R7201732 R7201752 R7201772 R7201734 R7201754 R7201774 R720174 R720176 R720178 R7201735 R7201755 R7201775 R169004 R169010 R111626 99010308 99010309 99010310 7 Round Duct Plate includes hardware Damper Duct Connector includes hardware Screw 8 18 x Y Hex 2 in package Rocker Switch Almond 2 in package Rocker Switch White 2 in package Rocker Switch Black 2 in package Rocker Switch Biscuit 2 in package Nameplate White Nameplate Almond Nameplate Stainless Nameplate Biscuit Nameplate Black Lens Screw 8 18 x 3 8 2 in package Ground Screw 2 req Wiring Cover includes hardware Rivet Pop 125 dia Filter Spring Kit Motor Mounting Screw 3 each part Motor includes Motor Mounting Kit Air Chute Assembly includes Key No 15 amp hardware Baffle Fan Blade Includes hairpin clip Hairpin Clip Filter Kit for 30 Hood 2 per bag Filter Kit for 36 Hood 2 per bag Filter Kit for 42 Hood 2 per bag Lamp Socket Harness Light Panel White for 30 Hood Light Panel White for 36 Hood Light Panel White for 42 Hood Light Panel Almond for 30 Hood Light Panel Almond for 36 Hood Light Panel Almond for 42 Hood Light Panel
10. 26976E
11. 78 cm para descarga vertical CABLEADO EL CTRICO DOMESTICO Parte superior o posterior de la campana TAPA DE TECHO LZ KA TAPA DE PARED m D CONDUCTO DE 8 3 cm x 25 4 cm para descarga horizontal De 45 7 cm a 60 9 cm SOBRE LA SUPERFICIE PARA COCINAR Determine si la descarga de la campana va a ser vertical conducto de 8 3 cm x 25 4 cm 3 x 10 o conducto redondo de 17 8 cm 7 horizontal s lo conducto de 8 3 cm x 25 4 cm 3 14 x 10 o si es un sistema sin conductos En el caso de descarga vertical u horizontal tienda los conductos entre el lugar donde va a instalar la campana y la tapa de techo o la tapa de pared Para obtener los mejores resultados utilice el n mero m nimo de transiciones y codos Utilice los siguientes diagramas para colocar adecuadamente los conductos y hacer el corte exacto para la conexi n el ctrica en el gabinete o en la pared En el caso de aquellas instalaciones en sistemas sin conductos NO haga ning n orificio de acceso para el conducto DISTEMA VERTICAL DE CONDUCTOS DE 8 3 cm x 25 4 cm 3 Y x 10 TORNILLOS PARA EL MONTAJE DE LA CAMPANA 4 35 4 CM campana de 76 2cm 35 4 CM campana de 76 2 cm 43 0 cm campana de 91 4 cm 4 43 0 cm campana de 91 4 cm 50 6 Cm campana de 106 7 cm 50 6 CM campana de 106 7 cm FRENTE DEL GABINETE 19 1 cm Le13 3 cmo lel3 3 cm Di 26 7 cm A 2 y 5 cm IN 412 7 cm oe conoucto horizo
12. AMPER DUCT CONNECTOR Remove Wir ing Cover from inside the hood Set cover and mounting screw aside WIRING COVER Remove either top or back wir ing knockout and install approved Electrical Cable Clamp ELECTRICAL CABLE CLAMP Non Ducted Installation Skip to Connect Wiring section The following Steps 6 thru 13 are for DUCTED INSTALLATION ONLY MA Remove Light Panel held in place with 3 8 screws and 2 8 screws Disconnect light assembly wire harness white connector Page 3 PREPARE THE HOOD y A p Y e N aR N 3 AIR CHUTE K N Y ar P iA ES f 5 A og Remove Air Chute held in place with one 1 screw NOTE Be care ful not to discon nect any wires Remove Baffle from air chute BAFFLE Rotate baffle Re insert baffle into air chute as shown so that baffle tabs fit all the way into slots in air chute An audible click will be heard when fully installed This will close off the air flow through the non ducted slots on top of hood SLOTS lt Re install air chute re connect wire harness and replace light panel A NOTE Be careful not to trap wires between support fin and light panel SUPPORT FIN Nulone ALLURE WS1 SERIES RANGE HOOD PREPARE THE HOOD TOP RECTANGULAR DUCT KNOCKOUT Remove for 3 4 x 10 Vertical amp for 7 Round Discharge
13. Nulone ALLURE WS1 SERIES RANGE HOOD ALLURE WS1 SERIES Page 1 E tie LLL LLL RANGE HOODS SO Patent No US D450 829 S ANNO READ AND SAVE THESE INSTRUCTIONS A FOR DOMESTIC COOKING ONLY A WARNING A TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards includ ing fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdraft ing Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection As sociation NFPA and the American Society of Heatin
14. TE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal despu s apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUE Y AVISE A LOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS Usted se podr quemar NO UTILICE AGUA incluyendo toallas de cocina mojadas puede resultar una explosi n de vapor violenta Utilice un extinguidor SOLAMENTE si Usted sabe que tiene un extinguidor de clas ABC y lo sabe utilizar El incendio es peque o y contenido dentro del rea donde se inicio Los bomberos han sido avisados Usted puede combatir el incendio con una salida a su espalda Basado en las recomendaciones para Seguridad en la Cocina publicadas por la NFPA de los EEUU p DOU gt E A Para el uso de interior solamente Solamente para uso general de ventilacion No utilice para descargar mate riales o vapores riesgosos o explosivos 3 Para evitar da os al motor y evitar que las navajas del abanico emitan mucho ruido o est n fuera de balance mantenga el motor libre de pelusa polvo etc 4 Para obtener mejores resultados en la captura de los vapores de la estufa el parte superior del extractor debe montarse a entre 45 7 a 60 9 cm sobre las hornillas de la estufa 5 Por favor lea la etiqueta con las especificaciones del equipo para otros req uisitos y mayor informaci n A la persona que realiza la instalaci n Deje est
15. a Una luz indicadora se ilumina cuando el ven tilador est encendido Luz El interruptor oscilante de 3 posiciones de la derecha controla las luces La posici n de la izquierda es luz de baja intensidad la posici n central es apagado y la posici n a la derecha es luz de alta intensidad LIMPIEZA ADVERTENCIA Para reducir el riesgo de una A descarga el ctrica desconecte el suministro el ctrico antes de limpiar la unidad Filtros de malla de aluminio Limpie frecuentemente los filtros con agua caliente y un detergente suave Los filtros se pueden lavar en lavaplatos Filtros de carb n Limpie frecuentemente los filtros con agua ca liente y un detergente suave NO sumerja los filtros en agua ni los coloque en el lavaplatos La caracter stica especial Clean Sense Detecci n de limpieza indica cuando se debe reemplazar el filtro Las l neas de puntos en la tira indicadora se convierten en l neas de ancho y s lido La caracter stica Clean Sense funciona mejor cuando se coloca orientada hacia la superficie para cocinar Para limpiar la campana Quite los filtros Use un pa o h medo y un detergente suave para limpiar las superficies con grasa Tenga cuidado cuando limpie la hoja del ventilador No se debe doblar ni desalinear NO PERMITA LA ENTRADA DE AGUA EN EL MOTOR Aseg rese de que todas las superficies est n completamente secas antes de volver a colocar los filtros y conectar la energ a el ctrica El
16. a piece of Cardboard to protect the cooktop if necessary GREEN GROUND SCREW Connect house black to hood black wire house white to hood white wire and house ground under Green Ground Screw Securely tighten cable clamp onto house wiring Replace wiring cover Nulone ALLURE WS1 SERIES RANGE HOOD INSTALL HOOD MOUNTING SCREW 4 Hang hood from 4 Mounting Screws from parts bag Slide hood towards wall until mounting screws are engaged in narrow end of 4 Keyholes Tighten mounting screws securely CAUTION DO NOT PUSH ON FAN BLADE Pushing on the blade may cause it to interfere with other hood parts DUCT TAPE Connect ductwork to hood Use Duct Tape to make joints secure and air tight PAR20 50W MAX HALOGEN BULB 2 or R16 40W MAX INCANDESCENT BULB 2 Install 2 PAR20 50 W Maximum Halogen Bulbs or 2 R16 40 W Maximum Incandescent Bulbs Purchase bulbs separately CAUTION Bulbs may be hot Refer to bulb packaging for further information Replace filters and make sure fan blade turns freely Turn on power at service panel and test for proper operation Page 5 NON DUCTED FILTERS If hood is to be installed Non Ducted Purchase a set of 2 non ducted filters from your local distributor or retailer and attach them to the aluminum mesh filters OPERATION A A ALLURE Fan The 3 position rocker switch on the left controls
17. ad del fabricante del equipo y de las sociedades profesionales de equipos de calentadores y los reglamentos de seguridad locales 5 A cortar o perforar la pared o el techo no da e el cableado el ctrico u otros servicios p blicos ocultos a la vista 6 Para reducir el riesgo de incendio o de descarga el ctrica no utilice este ventilador con ning n dispositivo de una control de velocidad de estado s lido adicional 7 Los abanicos con ducto deber n siempre tener una salida hacia el exterior 8 Para reducir el riesgo de incendio use s lo ductos de metal 9 Uso con el kit aprobado del la conexi n de la cuerda solamente 10 Esta unidad se debe instalar con tierra efectiva PARA REDUCIR EL RIESGO DE UN INCENDIO POR GRASA EN EN LA ESTUFA 1 Nunca deje sin atender las unidades de superficie cuando tengan ajustes altos Los reboses pueden provocar humo y derrames grasosos que se pueden incendiar Caliente lentamente el aceite en un ajuste bajo o medio 2 Siempre ENCIENDA la campana cuando cocine con alta temperatura o cuando cocine alimentos que se puedan incendiar 3 Limpie con frecuencia los ventiladores No debe permitir que la grasa se acumule en el ventilador ni en el filtro 4 Utilice un sart n de tama o adecuado Siempre utilice el utensilio adecuado al tama o del elemento de superficie PARA REDUCIR EL RIESGO DE LESION A PERSONAS RESULTADO DE UN INCENDIO DEBIDO A GRASA ACUMULADA EN LAS HORNILLAS PROCURE LO SIGUIEN
18. dondo de 17 8 cm 7 de la parte superior de la campana Col quela aparte con los tornillos de montaje FILTROS Quite la cinta que sujeta los filtros en su lugar Tire hacia abajo de las leng etas del filtro y s quelos levant ndolos Coloque los filtros a un lado Nulone CAMPANA EXTRACTORA SERIE WS1 ALLURE PREPARACION DE LA CAMPANA Quite el conector del regulador de tiro conector del interior de la cam pana Ponga aparte el conector con los tornillos de montaje y la bolsa de piezas CONECTOR DEL REGULADOR DE TIRO CONDUCTO Quite la cubierta de la conexion el ctrica del interior de la campana Ponga aparte la cubierta y los tornillos de montaje CUBIERTA DE LA C NEXI N EL CTRICA Quite el agujero ciego para los cables el ctricos ya sea el superior o el posterior e instale una grapa para cable el c trico aprobada GRAPA DEL CABLE EL CTRICO Para instalaciones sin conducto pase a la secci n Conexi n El ctrica Los siguientes pasos del 6 al 13 son SOLO PARA INSTALACI ONES CON CONDUCTO PANEL DE ILUMINACION 3 8 TORNILLOS con 3 8 tornillos y 2 8 tornillos Desconecte el juego del arn s del alam bre conectador blanco Quite el panel de iluminaci n fijado Pagina 9 PREPARACION DE LA CAMPANA CONDUCTO Quite el con aio AE ducto para aire fijado con un 1 tornillo NOTA Tenga cuidado d
19. e manual con el due o de la casa Al due o de la casa Las instrucciones de operaci n y limpieza se encuentran en la p gina 11 Si la campana se va a instalar en un sistema sin conductos Compre un juego de 2 filtros para sistemas sin con ductos en la tienda distribuidora o minorista de su locali dad y m ntelos en los filtros de malla de aluminio CONTENIDO Este manual se divide en las siguientes secciones PREPARACI N DEL LUGAR DONDE SE VA A INSTALAR LA CAM PANA Tienda de los conductos desde el techo o la tapa de pared y haga la con exi n el ctrica desde el panel de servicio hasta el sitio de la instalaci n PREPARACI N DE LA CAMPANA Prepare la campana para su instalaci n CONEXI N EL CTRICA Haga las conexiones el ctricas hacia la campana INSTALACI N DE LA CAMPANA Asegure la campana en el gabinete y en el sistema de conductos Instale focos y filtros OPERACI N C mo usar los controles de la campana LIMPIEZA Mantenga su campana en condiciones ptimas de funcionamiento PIEZAS DE REPUESTO N mero de las piezas y vista ampliada de los componentes de la campana GARANT A Garant a limitada de un a o y c mo comunicarse con nosotros Registre su producto en l nea en www nutone com register Nulone CAMPANA EXTRACTORA SERIE WS1 ALLURE PREPARACION DEL LUGAR DONDE SE VA A INSTALAR LA CAMPANA CONDUCTO DE 8 3 cm x 25 4 cm O REDONDO DE 1
20. e no desconectar ning n cable Quite el deflec tor del conducto para aire DEFLECTOR x am zi r y X g 7 A F pages gt pe N hti X y 4 ER 4 w A N A p d A s j e A gt MS aan eee ed a ee Mar gt 32 rS DEFLECTOR 9 Gire el deflec tor Vuelva a insertar el deflector en el conducto para aire de manera seg n lo dem ostrado que las aletas entren totalmente en las ranuras del conducto RANURAS para aire Un tecleo audible ser o do cuando est insta lado completamente Esto se cerrar del aire atraviesa las conducto para aire vuelva al conectar el arnes del alambre y substituya el panel de iluminacion NOTA Tenga cuidado de que ninguno ALETA DE APOYO de los cables quede atrapado entre la aleta de apoyo y el panel de iluminaci n gt ALETAS ranuras sin conduc tos encima de la campana Reinstale el ok E Nulone CAMPANA EXTRACTORA SERIE WS1 ALLURE PREPARACION DE LA CAMPANA AGUJERO CIEGO AGUJERO CIEGO SUPERIOR DEL CONDUCTO RECTANGULAR Quite en el caso de descargas verti cales de 8 3 cm x 25 4 cm 3 14 x 10 o de descargas con conductos redondos de 178 cm 7 CIRCULAR Quite en el caso de redondos de 178 cm 7 AGUJERO CIEGO POSTERIOR DEL CONDUCTO RECTAN GULAR Quite en el caso de descargas horizontales de 8 3 cm x 25 4 cm 3 14 x 10 Quite el agujero o agujeros ciegos para
21. ego de montaje de motor Juego de conducto para aire incluye claves no 15 y herraje Deflector Hoja del ventilador incluye sujetador de horquilla Sujetador de horquilla Juego de filtros para campanas de 76 2 cm 2 por bolsa Juego de filtros para campanas de 91 4 cm 2 por bolsa Juego de filtros para campanas de 106 7 cm 2 por bolsa Cableado preformado para el recept culo del foco Panel de iluminaci n blanco para campanas de 76 2 cm Panel de iluminaci n blanco para campanas de 91 4 cm Panel de iluminaci n blanco para campanas de 106 7 cm Panel de iluminaci n almendra para campanas de 76 2 cm Panel de iluminaci n almendra para campanas de 91 4 cm Panel de iluminaci n almendra para campanas de 106 7 cm Panel de iluminaci n negro para campanas de 76 2 cm Panel de iluminaci n negro para campanas de 91 4 cm Panel de iluminaci n negro para campanas de 106 7 cm Panel de iluminaci n inoxidable para campanas de 76 2 cm Panel de iluminaci n inoxidable para campanas de 91 4 cm Panel de iluminaci n inoxidable para campanas de 106 7 cm Panel de iluminaci n cer mica para campanas de 76 2 cm Panel de iluminaci n cer mica para campanas de 91 4 cm Panel de iluminaci n cer mica para campanas de 106 7 cm Luz indicadora incluye 2 tuercas de alambres y lentes Montaje de diodo de la luz incluye tuerca de alambre Arn s de alambres Juego de filtros para sin conductos 76 2 cm 2 por bolsa Juego de filtros
22. g Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 To reduce the risk of fire or electric shock do not use this range hood with an additional speed control device 7 Ducted fans must always be vented to the outdoors 8 To reduce the risk of fire use only metal ductwork 9 Use with approved cord connection kit only 10 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE 1 Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings 2 Always turn hood ON when cooking at high heat or when cooking flaming foods 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OFA RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels violent steam explosion will result 4
23. los conductos apropiados de la parte superior o de la parte posterior de la campana BORDE SUPERIOR CINTA POSTERIOR AJUSTE LATERAL HASTA DE 2 5 CM 1 CONECTOR DEL REGULADOR DE TIRO CONDUCTO Se muestra la posicion de descarga vertical PIVOTE S lo para descargas con conductos de 8 3 cm x 25 4 cm 3 4 x 10 Coloque el conectador del regulador de tiro conducto sobre la abertura del agujero ciego Aseg rese de que el pivote del regulador de tiro quede lo m s cerca posible del borde superior posterior de la campana Quite la cinta de la aleta del regulador de tiro S lo para descargas con conducto redondo de 17 8 cm 7 Vuelva a instalar la placa del conducto redondo de 17 8 cm 7 que quit en el paso 1 de la secci n PREPARACION DE LA CAMPANA Instale un regulador de tiro redondo de 7 se compra por separado La aleta del regulador se debe abrir libremente en direcci n del flujo de aire en sentido contrario a la campana de la estufa Para acomodar los conductos descentrados el conector del NOTA regulador de tiro conducto se pueden instalar a una distancia hasta de 2 5 cm 1 desde el centro de la campana hacia cualquier lado o la placa del conducto redondo de 17 8 cm 7 se pueden instalar a una distancia hasta de 1 3 cm desde el centro de la campana hacia cualquier lado En instalaciones exc ntricas extremas un extremo del conector de regulador de conducto puede
24. nectados en el extremo angosto de los 4 orificios tipo bocallave Apriete fijamente los tornillos de montaje PRECAUCION NO EMPUJE EN LA HOJA DEL VENTILADOR El empujar en la aspa del ventilador puede hacerla interferir con otras piezas de la capilla CINTA PARA CON DUCTOS Conecte el sistema de conductos en la campana Use cinta ara conductos para fijar y sellar las uniones FOCO DE HAL GENO PAR20 50W MAX 2 O R16 40W MAX BULBOS INCANDESCENTES 2 Instale 2 focos de hal geno PAR20 de 50 W m ximo o 2 R16 bulbos incandescentes del m ximo de 40W Compre los bulbos por separado 1 PRECAUCION Los bulbos pueden ser calientes Refiera a la empaqueta del bulbo para la informaci n adicional Vuelva a colocar los filtros y aseg rese de que la hoja de ventilador gira libremente Conecte la energ a en el panel de servicio y revise el funcionamiento adecuado de la campana P gina 11 FILTROS SIN CONDUCTOS Si la campana se va a instalar en un sistema sin conductos Compre un juego de 2 filtros para sistemas sin conductos en la tienda distribuidora o minorista de su localidad y sujete a los filtros de malla de alumino OPERACI N Ventilador El interruptor oscilante de 3 posiciones de la izquierda controla el ventilador La posici n hacia la izquierda es la velocidad baja la posici n central es apagado y la posici n hacia la derecha es la velocidad alt
25. nra amp oli y 3 2 cm e 3 8 cm 4 CU AS DE MADERA mEa ORIFICIO DE ACCESO PARA LOS CABLES EL CTRICOS en el fondo del gabinete s lo gabinetes de fondo empotrado CENTRAL SISTEMA HORIZONTAL DE CONDUCTOS DE 8 3 cm x 25 4 cm 3 x 10 CU AS DE MADERA s lo gabinetes de fondo empotrado FRENTE DEL GABINETE FONDO DELL GABINETE 35 4 cm campana de 76 2 cm 43 0 cm campana de 91 4 cm 50 6 cm campana de 106 7 cm 188 cm 43 0 cm campana de 91 4 cm 50 6 cm campana de 106 7 cm t ORIFICIO DE ACCESO LINEA PARALOS CABLES CENTRAL EL CTRICOS en la pared TORNILLOS PARA EL MONTAJE DE LA CAMPANA 4 P gina 8 PREPARACI N DEL LUGAR DONDE SE VA A INSTALAR LA CAMPANA SISTEMA VERTICAL DE CONDUCTOS REDONDOS DE 17 8 CM 7 50 6 cm campana de 106 7 cm 1 50 6 cm campana de 106 7 cm FRENTE DEL GABINETE FONDO DEL GABINETE 19 1 cm ORIFICIO ORIFICIO DE ACCESO PARA _ 26 7 cm EL O ear Pall 0 REDONDO DE 17 8 cm 12 7 cm Ny l 8 cm CU AS DE MADERA 1 s lo gabinetes de LINEA fondo empotrado CENTRAL ORIFICIO DE ACCESO PARA LOS CABLES ELECTRICOS en el fondo del gabinete Haga las conexiones del cableado dom stico entre el panel de servicio y el lugar donde va a instalar la campana PREPARACI N DE LA CAMPANA PLACA DEL CONDUCTO REDONDO DE 17 8 CM 7 wD y i gt Quite la placa del conducto re
26. para sin conductos 91 4 cm 2 por bolsa Juego de filtros para sin conductos 106 7 cm 2 por bolsa Pida piezas de repuesto dando como referencia el N DE PIEZA no el N DE CLAVE Herraje est ndar se puede comprar en la ferreter a de la localidad No ilustrado Las piezas de recambio se pueden ahora pedir en nuestro Web site Vis tenos por favor en www NuTone com GARANTIA GARANTIA NUTONE LIMITADA POR UN ANO NuTone garantiza al consumidor comprador original de sus productos que dichos productos carecer n de defectos en materiales o en mano de obra por un per odo de un a o a partir de la fecha original de compra NO EXISTEN OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante el per odo de un a o y a su propio criterio NuTone reparar o reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso ESTA GARANTIA NO SE APLICA A TUBOS Y ARRANCADORES DE LAMPARAS FLUORESCENTES Esta garant a no cubre a mantenimiento y servicio normales o b cualquier producto o piezas que hayan sido utilizadas de forma err nea negligente que hayan causado un accidente o que hayan sido reparadas o mantenidas inapropiadamente por otras compa as que no sean NuTone instalaci n defectuosa o instalaci n contraria a las inst
27. rucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la limitaci n antes mencionada puede no aplicarse a usted LA OBLIGACION DE NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DE NUTONE DEBERA SER EL UNICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANTIA BROAN NO SERA RESPONSABLE POR DANOS INCIDENTALES CONSIGUIENTES O POR DANOS ESPECIALES QUE SURJAN A RAIZ DEL USO O DES EMPENO DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consiguientes por lo que la limitaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar en la garant a de servicio usted debe a notificar a NuTone al domicilio o num ro de tel fono na abajo b dar el n mero del modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar servicio cubierto por la garant a usted debe de presentar evidencia de la fecha original de compra Broan NuTone LLC Hartford Wisconsin www nutone com 888 336 3948 6
28. to hood INSTALL HOOD Secure hood to cabinet and ductwork install bulbs and filters OPERATION How to use the hood controls CLEANING Keep your hood in top working condition SERVICE PARTS Part numbers and exploded view of hood components WARRANTY One year limited warranty and how to contact us Register your product online at www nutone com register N ulo a e ALLURE WS1 SERIES RANGE HOOD Page 2 PREPARE HOOD LOCATION PREPARE HOOD LOCATION ROOF CAP CE 3 x 10 or Sees 7 ROUND 7 ROUND DUCT HOOD MOUNTING SCREWS 4 _ i S lt For vertical discharge 1315 16 30 hood 4 VERTICAL DUCTING 1615 16 36 hood 13 16 30 hood 1915 16 42 hood 1615 16 36 hood Ren SS F CABINET FRONT 4915 46 42 hood LLLLLLL LLLI SOFFIT _ 1 N i gt HOUSE WIRING CABINET o CABINET X Top or Back of hood BOTTOM D AORT R siy ss VAN 10 FOR 7 ROUND O AAA STIN WALL CAP CHE 5 G ell T o FA 24 30 ABOVE Ne vy ann t COOKING SURFACE S AA WOOD SHIMS t hee ae N For horizontal discharge recessed bottom CENTER cabinets only LINE in cabinet bottom 1 Determine whether hood will discharge vertically 3 x 10 ap or 7 Round horizontally 3 x 10 only or non ducted For Run house wiring between service panel and hood location vertical or horizontal discharge run ductwork between the hood location and a roof
29. y Not illustrated improper maintenance or repair other than by NuTone faulty installation or installation contrary to recommended installation instructions The duration of an implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WAR RANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of request ing warranty service you must present evidence of the original purchase date Broan NuTone LLC Hartford Wisconsin www nutone com 888 336 3948 Replacement parts can now be ordered on our website Please visit us at www NuTone com 626976E