1. Devices 4 Button Transmitter 4B 101 4B 434 Panic Transmitter PT 434 HW 434 Keypad Transmitter KP 434 Control Panel SC 001 Sensors Door Window Sensor fT Flood Sensor i WD 101 FS 101 ss Sensor Audio Sensor AS 101 Temperature Sensor TS 101A Garage Door Monitor Sensor Vibration Sensor GS 101 VS 101 There are 2 types of sensors and accessories Panic Devices These are devices such as 4 Button Transmitter Panic Transmitter and Keypad Transmitter When the panic button on these transmitters is activated the Dial Alert will dial out regardless whether it is in armed or disarmed mode Sensors These sensors will only trigger the Dial Alert if it is armed If the Dial Alert is not armed the Dial Alert will not be activated even if the sensors are triggered If you have sensors installed ensure you arm the Dial Alert if you want to be notified by sensor activation Please refer to the programming instructions STANDARD PROGRAMMING to set up the operation mode of your emergency dialer INSTALLATION The Dial Alert is installed using the screws provided We have also included double sided tape to use for temporary installation while you are positioning the dialer Once the dialer is positioned correctly install it permanently with screws We have also included wall anchors and a template to help position the screws correctly How to use the template 1 Cut the template in t
2. any other phone number and return to standby mode 7 ADVANCED PROGRAMMING Changing Password Password is required for programming purposes Factory default is OOOO To change the setting follow the instructions below 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 2 to change password Display now shows nPIn that means New PIN 3 Enter the new 4 digit password 4 Display now shows rPIn meaning re enter the new pin Enter the new 4 digit password again 5 If the new password is accepted it will emit 2 beeps If you don t hear 2 beeps that means the password is not accepted retry again Calling Time The Calling Time is how long the phone will ring before it is disconnected lf the recipient does not pick up the phone after this time period Dial Alert will disconnect and redial The factory default calling time is 45 seconds To change the setting follow the instructions below 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 7 to change the calling time Display now shows P7 2 the most right digit represents the calling time setting Refer to the table below for the calling time setting 1 30 seconds 2 45 seconds 3 60 seconds 4 75 seconds 5 90 seconds 3 Enter the desired v
3. delay 4 If the new setting is accepted it will emit 2 beeps If you don t hear 2 beeps that means the setting is not accepted retry again Arming Disarming To arm the dialer simply enter the password and then press The ARM LED will be on To disarm the dialer simply enter the password and then press The ARM LED will be off If your dialer is working directly with a control panel there is no need to arm the dialer The dialer will dial out regardless if it is armed or not when it receives a panic signal from the control panel 921 ADVANGED PROGRAMMING If you have sensor s programmed to the Dial Alert you should arm the Dial Alert if you want to receive notification when the sensor is activated If the Dial Alert is not armed sensor activation will not trigger the dialer Therefore please arm the system when you want to be notified of sensor activation such as when you are away from home If you are home you may disarm the Dial Alert if notification is not needed CONNECT THE DIAL ALERT WITH YOUR EXISTING ALARM SYSTEM You may connect your existing alarm system with the Dial Alert so that the dialer will be triggered by your alarm system when it is activated There are 2 ways you can connect your dialer with your existing alarm system 1 Connect the dialer with the alarm system PANEL OR SENSOR using hard wire normally closed N C LATCHING AD 105 DRY CONTACT 2 Connect the dial
4. on whether the Exit delay is set if so display will show dELAy flashing and beeping during the exit delay period If exit delay is not set the arm LED will be on and display shows rEAdy meaning there is no exit delay Alarm will be activated immediately if a sensor is triggered 4 Once the AD 105 is armed it will respond to a sensor activation RECEIVING A PHONE CALL When the dialer is activated it will call the pre programmed phone numbers and playback the selected messages The recipient can take the following actions after listening to the voice message 16 OPERATIONS 1 To stop the call from calling a specific phone number Since there is a redial count and regardless of whether the call is picked up or not it will redial based on the redial counts If the redial count is set to 3 times that means it will call that phone number 3 times If the recipient acknowledges the call and does not want it to call the same number again he she can enter This will stop the Dial Alert from calling this same phone number again and it will dial the rest of the other programmed phone numbers 2 To stop the call from calling all phone numbers Usually you will setup the Dial Alert to call yourself the home owner as the first phone number It is likely that if you acknowledge the call you do not need to call the rest of the phone numbers If so you can enter the 4 digit password so the Dial Alert will not dial
5. return to standby mode 6 The display still shows not rEAdy because no phone number has been programmed MESSAGE PLAYBACK If you would like to listen to the recorded message you can playback the message by following the instructions below 1 Enter the current password factory default password is 0000 then press lt 1 then press 3 display will show L3 meaning you are now in voice message playback mode 2 Enter the number that represents which message you want to playback 4 Zone 4 Message 5 Zone 5 Message 6 Zone 6 Message 0 Main Message 1 Zone 1 Message 2 Zone 2 Message 3 Zone 3 Message 3 Display now shows something like L3 1 05 where the last 2 digits represent the duration of the voice message you have recorded Press 1 will playback the recorded message PROGRAM A PHONE NUMBER You may program up to 9 different phone numbers Follow the instructions below to program phone numbers 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 4 which represents phone number programming You will see P4 PHonE 1 The number on the most right represents the phone number from Phone 1 to Phone 9 3 Select the phone number you would like to program from 1 9 then press 41 4 Enter the phone number then press 41 5 Display will show rEdIAL 3 this is the default redial coun
6. the playback feature For security purposes the speaker may be turned off after pro gramming to allow for silent dialing when the dialer is activated The On Off switch for the speaker is located on the lower right corner of the circuit board The default setting for the speaker is On LIGHTS AND SOUNDS STANDARD PROGRAMMING Below is an explanation of the lights and sounds of the Dial Alert LIGHTS ACPWR light on ACPWAR light off LOBATT light off LOBATT light on ARM light on ARM light off Keypad backlight SOUNDS Short beep Two short beep s Long beep Steady repeated beep SPEAKER dialer is being powered by AC adapter dialer is not receiving any AC power backup battery is connected and working backup battery is weak battery needs to be replaced the dialer is in armed condition It will dial out when it receives sensor activation signal and panic signal from Panic Devices dialer will not dial out if there is sensor activation It will only dial out when it receives panic signal from Panic Devices If unit is powered by AC adapter back light stays on all the time If unit is powered by battery only back light stays on 10 seconds after a key is pressed You have pressed a key in the right order 1 When the dialer is turned on for the first time 2 When the pre programmed transmitters sensors are deleted from the memory You have made a mistake The dialer has been triggered i
7. these 3 phone numbers are all 3 times Dial Sequence 1 Dial each phone number once then dial each phone number the second time in the same sequence i e Phone 1 Phone 2 Phone 3 Phone 1 Phone 2 Phone 3 Phone 1 Phone 2 Phone 3 Dial Sequence 2 Finish all redial count for the first phone number then dial the second phone number i e Phone 1 Phone 1 Phone 1 Phone 2 Phone 2 Phone 2 Phone 3 Phone 3 Phone 3 The factory default is set to Dial Sequence 2 To change this setting follow the instructions below 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 19 ADVANCED PROGRAMMING 2 Enter 0 display now shows PO 2 the most right digit represents the dial sequence 3 To change the setting enter either 1 or 2 where 1 is Dial Sequence 1 and 2 is Dial Sequence 2 4 If the new setting is accepted it will emit 2 beeps If you don t hear 2 beeps that means the setting is not accepted retry again Universal Dial Tone You may setup the Dial Alert to dial only a proper dial tone if it is detected If no dial tone is detected it will not dial As there are many different dial tones with different telephone systems or the tone is different in different parts of the country you may set it up so that the Dial Alert will dial no matter what type of dial tone is detected To enable a universal di
8. If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual please 1 visit our FAQ section at www skylinkhome com or 2 email us at support amp skylinkhome com or 3 call our toll free at 1 800 304 1187 from Monday to Friday 9 am to 5 pm EST Fax 800 286 1320 1012810 002 SEPT 2010 SRY LINC www skylinkhome com Emergency Dialer DIAL ALERT MODEL AD 105 i PREMISES PROTECTED BY ELECTRONIC SECURITY SYSTEM CUSTOMER SERVICE 17 Sheard Avenue Brampton Ontario Canada L6Y 1J3 Tel 800 304 1187 Fax 800 286 1320 Email support Q skylinkhome com HEALTH CARE HELP PAT D410633 6243000B1 SKYLINK TECHNOLOGIES INC TABLE OF CONTENTS Your Guide to the PACKAGE COIN EAN EN rttr tnertrE ttnt enn 4 Emergency Dialer OE EE EN 5 6 NET e 7 9 DIAL ALERT LIGHTSAND SOUNDS sccsssscssssssssssessssssssssstssssesneseenssesnnenssnnssennenesneeneenneesenet 10 STANDARD PROGRAMMING cisssessccdecciiciseintsdete hesecnaasspiagheaetenctateazapeesenscilpcousiuitesciace 11 15 MODEL AD 105 Selecting the Operation MOdGC cccccccssececceesseeeceeeeeeceeegeeeeeeesseesseeeeeeeees 11 Recording a Voice WICSSAGC vine siceyecessonutssieunnenceawesanssinnsanedeenecssuensgsemdedanywadgidwotenss 12 SEE Ga IAVOACK EEE EE 13 Program a Phone NUMDE swscacconisxnnacanensseradadssdltiawmatdne deans teladsesap
9. al tone follow the instructions below 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter then 1 display will show P 1 2 3 Enter 1 to disable universal dial tone meaning a proper dial tone must be presented before dialing or 2 to enable universal dial tone so the Dial Alert will dial regardless of the dial tone 4 If the new setting is accepted it will emit 2 beeps If you don t hear 2 beeps that means the setting is not accepted retry again Pick up Pause Period Pick up Pause allows you to have a pause period after the recipient picks up the call This is useful if you are sending a numeric message to a pager or sending a voice message to an answering machine You may define the pause period from 1 sec to 9 seconds To change the setting follow the instructions below 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 9 display now shows P9 5 the most right digit represents the pick up pause duration 3 Enter any number from 1 to 9 which represents the pick up pause duration i e enter 1 fora 1 second pause enter 7 fora 7 second pause Press 1 to confirm your entry 4 If the new setting is accepted it will emit 2 beeps If you don t hear 2 beeps that means the setting is not accept
10. alue based on the table below For example enter 5 to set the calling time to 90 seconds 4 If the new setting is accepted it will emit 2 beeps If you don t hear 2 beeps that means the setting is not accepted retry again 18 ADVANCED PROGRAMMING Erase Programmed Panic Transmitters Alarm Panels Sensors You may erase the programmed wireless devices panic transmitter alarm panels and wireless sensors You cannot erase a specific device you must erase all the devices and then program the ones that you would like to keep To erase all the wireless devices follow the instructions below 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 6 to erase programmed devices Display shows P6 ErASE 3 Press lt 1 to erase all programmed devices 4 You have erased all the devices if you hear 2 beeps Dial Sequence As mentioned there is a Redial Count for each phone number that means when the dialed phone number is busy or cannot be connected the Dial Alert will dial the number again or dial another phone number You may program it so it will finish dialing one phone number with all redial counts then dial the next number or you may program it so that it will dial each phone number once then if they are busy dial the second attempt Example There are 3 programmed phone numbers and the redial count for
11. ed retry again 20 ADVANCED PROGRAMMING Entry Exit Delay For Sensor Mode Entry Exit Delay is used when you use the dialer in Sensor Mode when it is communicating with individual sensors as an alarm panel You may arm and disarm the dialer so that sensors can communicate with the dialer When you arm the system you get an exit delay to leave the premises The dialer will start monitoring the sensors after the exit delay meaning after the exit delay any triggered sensor will activate the dialer Entry delay is the amount of time you have to disarm the dialer after you activate a sensor when coming back home You may trigger a sensor when you come back home and the dialer will start the entry delay You must disarm the system during the entry delay period in order for the dialer not to dial out To program the entry delay and exit delay follow the instructions below The values will be the same for both of these delays 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 8 display now shows P8 1 the most right digit represents the entry exit delay duration 3 Enter any number from 1 to 5 which represents the entry exit delay duration 1 Instant Arming Instant Alarm 2 30 seconds entry exit delay 3 45 seconds entry exit delay 4 60 seconds entry exit delay 5 75 seconds entry exit
12. emergency dialer can call multiple phone numbers during an emergency situation and it will playback prerecorded messages There are 2 operating modes you can set up in the AD 105 dialer SC 001 Mode Works with SC 001 You can setup the AD 105 to communicate with a control panel SC 001 so when the SC 001 alarm is activated it will send a panic signal to the dialer and it will call you and other phone numbers up to 9 phone numbers and then playback a 40 second pre recorded message Signal AD 105 Sensor Mode Works with multiple sensors directly You can program sensors directly to the AD 105 so when any one of the sensors is triggered the dialer will dial the programmed phone numbers and playback voice messages It is possible to record one primary voice message and up to 6 unique messages these unique messages will be sensor specific gt Various e o Sensor Sensor Activation AD 105 Signal 5 OVERVIEW Dial Alert AD 105 must work with the specific sensors listed below Ensure only the listed sensors are used with the AD 105 otherwise the communication between the sensors and the Dial Alert may not function properly If you have a Skylink wireless device or sensor that is not listed below and uncertain whether it can work with your AD 105 please contact our customer support team You can program the following sensors and accessories to the dialer they are fully compatible with Dial Alert AD 105 Panic
13. er with the alarm system NORMALLY CLOSED Remove the l using the Audio Sensor AS 101 o tala jumper first Follow the diagram below for hardwiring the dialer with the existing alarm system Every time the alarm system is activated it will automatically trigger the dialer to dial out all the preset telephone numbers and play the pre recorded message Remove the jumper first Place the Audio Sensor beside the siren of your existing alarm system once the alarm is activated the siren will sound and the Audio Sensor will be triggered and send a signal to the Dial Alert to activated it There is no wiring involved in this case The other way to trigger the dialer by the existing alarm system is to use the Audio Sensor AS 101 in conjunction with the Dial Alert see Additional Accessories page 24 DIAL ALERT QUICK GUIDE Factory Program Functions Settings Default 1 Sensor Mode 2 SC 001 Mode PIN PROG 2 Any 4 digit password 0 Main Message 1 6 Secondary Messages PIN PROG 9 Pick up Pause 1 1 sec 2 2 seconds 9 9 seconds PIN PROG 0 Dialing Sequence 1 Dials each number once then redial if necessary 2 Finish dialing first phone number then begins second number BATTERY MAINTENANCE The AD 105 Dial Alert comes with 1 battery that at some point you may have to replace One 9Qvolt alkaline battery for the Dial Alert Recommendation Test your Dial Al
14. ert periodically to ensure that the battery is working Dial Alert Battery The Dial Alert comes equipped with a 9V backup battery in case the elec trical power is interrupted for any reason When the dialer backup battery is low the LOBATT light goes on To replace the dialer backup battery 1 Undo the two screws on the back of the Dial Alert 2 Open the Dial Alert case by pressing down on the two tabs on the top edge and pull the front forward 3 Disconnect the old battery 4 Connect the new battery 5 Close the Dial Alert case and re insert the two screws The battery life 9 volt alkaline battery is approximately two years if used only for backup 93 ADDITIONAL ACCESSORIES Additional sensors and transmitters as well as add on accessories are available to work with your Dial Alert Security Control Panel SC 001 Four alarm modes Day Night Away Chime Four zones each zone controls up to 6 devices Reliable design with microcontroller 110dB siren Door Window Sensor WD 101 Attaches to all doors windows entrances SV lithium battery included Motion Sensor PS 101 Monitors area in a 110 degree ARC and up to 40 feet away from the sensor 9V alkaline battery included Keychain Transmitter 4B 101 4B 434 Activates Security Control Panel SC 001 instantly by pressing panic button Arm Disarm Security Control Panel SC 001 Reliable design crystal base
15. he correct position 2 Screw part way into the surface where the holes are marked 3 Unscrew the screws and remove the template 4 Screw the component in place where you started the screws INSTALLING THE DIAL ALERT AD 105 Position the dialer beside a telephone or near any phone line and within access of an electrical outlet However it is recommended that you hide the dialer for security purposes The dialer runs on regular electrical current It also contains a 9 volt backup battery in case power is interrupted for any reason A phone line must be connected to the dialer in order for the dialer to work Connect the phone lines and AC adapter as shown 2 2 3 905 456 8883 12V DC i ACADAPTER OPTIONAL LINE INPUT FOR PHONE ANSWERING MACHINE TELEPHONE TEL LINE IN LINE Note The optional line input is intended for an answering machine telephone etc The device connected to the dialer will be disconnected when the dialer is activated Therefore it will not affect the operation of the dialer There are 3 ways to attach the Dial Alert on the wall 1 Using double sided tape for temporary use 2 Hanging it from the two keyholes on two stationary screws 3 Screwing the back onto the wall with four screws To mount the Dial Alert 1 Open the case a Press the two tabs on top of the dialer b Pull open the front INSTALLATION 2 Thread the telephone line through the top hole in the back
16. m up to 16 different devices to the Dial Alert TESTING SC 001 Mode To test the operation you may activate dialer by pressing the red panic button on the SC 001 AD 105 will dial the phone numbers and playback the voice message Sensor Mode You can put the AD 105 in arm mode and activate the programmed sensor AD 105 will dial the phone numbers and playback the voice message Follow Operations Arming Sequence to arm the AD 105 15 OPERATIONS SC 001 Mode When the display shows rEAdy that means the unit is in standby mode It will dial when it receives a panic signal from the alarm panel or its own panic button is pressed It will dial the programmed phone numbers and playback the voice message It is not necessary to put the AD 105 in arm mode Once the display shows rEAdy the AD 105 will respond if it receives a command to dial out Sensor Mode When the AD 105 operates in Sensor Mode it needs to be armed in order to respond to a sensor signal When the AD 105 is not armed it will not respond to any sensor activation except when the triggering devices area panic transmitter or a panic button from a wireless keypad or a panic button from a 4 button remote control AD 105 will respond to a panic signal even it is not armed To arm the AD 105 1 Enter the current password factory default password is 0000 then press 2 Arm red LED will be on indicating it is on 3 Depends
17. n DELAY mode It gives you time to disarm the dialer before dialing the emergency phone numbers LCD DISPLAY PANIC BUTTON ARM BUTTON ENTER PROGRAM BUTTON NUMERIC KEYPAD 10 There are a few programming steps you must perform before the dialer can operate Please follow the instructions below to program these fields including Selecting the Operation Mode Record voice messages Phone numbers you wish to dial during emergency up to 9 phone numbers Program the panic button or alarm panel to the dialer When you first power up the Dial Alert the display will show not rEAdy that means you don t have a voice recording and no phone number programmed You must perform the following programming steps in order for the Dial Alert to function during an emergency Note During programming there is a 10 second time out meaning each step must be completed within 10 seconds SELECTING THE OPERATION MODE As mentioned the AD 105 works with the Control Panel SC 001 or directly communicates with sensors i e 2 operating modes are 1 SC 001 Mode With this mode the dialer will be activated when it receives a panic signal from SC 001 Control Panel You can record one 40 second voice message 2 Sensor Mode With this mode the dialer can be activated by preprogrammed sensors and you can record one primary voice message 9 second and 6 secondary messages 5 seconds each When you program the sensors you ca
18. n select which secondary voice message to play when that sensor is activated Follow the instructions below to setup the operating mode 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 1 to select the operating mode Display now shows P1 2 the most right digit represents the operating mode 1 Sensor Mode 2 SC 001 Mode 3 Enter the desired value For example enter 1 if you want to set up the dialer to work with sensors 4 If the new setting is accepted it will emit 2 beeps If you don t hear 2 beeps that means the setting is not accepted retry again 11 STANDARD PROGRAMMING STANDARD PROGRAMMING RECORD A VOICE MESSAGE You must record a message and program at least one phone number in order for the Dial Alert to work The voice recording procedure is different between the 2 operating modes SC 001 Mode and Sensor Mode To record a voice message under SC 001 Mode 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 3 which represents voice recording You willsee P30 40 The number on the most right represents the voice recording duration 40 means 40 seconds 3 To start recording press 1 button You now can start to record the voice message The number 40 will decrease and voice
19. of the unit and plug it into the LINE jack If you want to have an answering machine on the same line as the dialer thread the phone line through the bottom hole in the back of the unit and plug it into the PHONE jack of the dialer The phone line s must be inserted through the back of the unit before it is attached to the wall 3 Thread the AC adapter cord through the top eg in gt hole in the back of the unit and plug it into a the AC connector on the circuit board as 7 shown The adapter cord must be inserted through the back of the unit beforeit is attached to the wall 4 Insert the 9 volt battery and rotate the antenna from the inside of the dialer to the outside 5 Firmly close the case Insert and secure the two screws to the bottom case near the two tabs 6 Using the template provided insert the two screws into the wall 7 Gently hang the Dial Alert to these two SCrews 8 Plug the other end of the telephone cord into a telephone jack Plug the AC adapter into a power outlet The red AC PWR light will turn on and the keypad backlight will be on NOTE After installation please use two screws included to fix the front and back case together before hanging on to the wall When you open the case please remove the AC adapter and the phone line from the wall outlet INSTALLATION Speaker On Off Switch The speaker must be on during pro gramming and recording the voice message in order to use
20. ontewndoaseornpnsedvane 13 Program a sensor under sensor operating MOde rrrrrnnrnnrnnnnvrnnvnvnrnrrrnnrrnnnnn 15 TE 15 OPERATION crre E 16 17 SINE 16 Ke NSO MOUE EE EEE 16 Receiving a phone CA eda 16 ADVANCED PROGRAMMING c ccccceeceseceteeeeeeeeeeseeeseeeseeeeessaeseaeseaeseeseeseaeseaeeaaes 18 22 PEN 18 Program the Calling TNE rv 18 Erase programmed Panic Transmitters Alarm Panels Sensors 00608 19 Dial Sequence 5 SI ING EE RE NE nnter 19 Universal Dial WONG a arriuncssamansactaseiciaoueeumiesasenate vareauaadessnsemenseedecdeaeeevautennenaccedeeune 20 Miek UDF IS Sr OO esenea R ER 20 Entry Exit Delay For Sensor MOde ssseeeeeeeeeeceeeeeessseeeeeeeeeeseeeeesseseees 21 PEIN LAS 1100 EE EN rrna 21 CONNECT THE DIAL ALERT WITH YOUR EXISTING ALARM SYSTEM 64 22 QUICK GUIDE a aeeiio rei ER a iE 22 BATTERY MAINTENANCE sscccccncuciseduceantsvscuenatedaiuesatbpedienoaiietioncadsaneticnediansniceae 23 DIG 5 EE EE EE 23 PD DITIONAL ACCES SO RES ua 24 26 The AD 105 Emergency Dialer contains all the above items PACKAGE CONTENTS All materials required for installation are included with this package 1 Dial Alert AD 105 1 Telephone Line 1 antenna installed 1 AC adapter 1 9 volt alkaline battery 1 Pack of screws and anchors for Dial Alert One template Double sided tape User s instructions Warranty Card Quick Guide 4 OVERVIEW The AD 105
21. recording will stop when it reaches 0 You may also press 4 at anytime to stop the voice recording 4 After recording the message you will hear the recorded message After the message playback it will quit from programming and return to standby mode 5 The display still shows not rEAdy because no phone number has been programmed To record a voice message under Sensor Mode 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 3 which represents voice recording You will see P30 09 The number following P3 is the message number 0 is the primary message max 9 seconds and 1 to 6 represent messages 1 to 6 each can be 5 seconds The most right digits represents the voice recording duration 09 mean 9 seconds 3 Enter 0 to 6 to select which message you would like to record If you enter 3 you should see P33 05 Note remember what message you record to each recording when you program a sensor later on you can select which message you want it to playback 4 To start recording press 4 button You now can start to record the voice message The number will decrease and voice recording will stop when it reaches 0 You may also press lt a anytime to stop the voice recording 5 After recording the message you will hear the recorded message After the message playback it will quit from programming and
22. smitter all the time Operates using lithium batteries included 95 ADDITIONAL ACCESSORIES Audio Sensor AS 101 Detects alarm sound from existing security system alarm sends signal to Dial Alert Eliminates need for monitoring service 9V alkaline battery included Vibration Sensor VS 101 Activates Security Control Panel or Emergency Dialer when vibration is detected Attach vibration sensor to valuables SV lithium battery included Garage Door Monitor Sensor GS 101 Place sensor on garage door Activates Security Control Panel or Emergency Dialer when the garage door is opened SV lithium battery included 26
23. t Press 4 to accept or enter a value from 1 9 to change the setting Redial count is how many times this phone number will be retried if it is busy 6 Display will show rEPEAt 3 this is how many times the voice message will be played Press 4 to accept 3 times or enter a value from 1 9 to change the setting Note Skylink recommends that the telephone or pager numbers of your relatives neighbors office work friends or doctor be programmed into your Dial Alert 43 STANDARD PROGRAMMING Do not program the phone number to police or fire dept directly into your Dial Alert unless you have checked with your local authorities Please also inform all the recipients that their phone numbers have been programmed into your dialer so they know exactly what happens when they receive your emergency message 7 The Dial Alert is now in standby mode and the display shows rEAdy meaning you have recorded a voice message and have a least one phone number programmed You may sometimes need to insert pause period in a phone num ber so you can pause the dialing process there are 2 types of pause periods 1 Normal Pause 2 Pick up Pause Normal Pause can be inserted to any part of the phone number and it will simply pause the dialing process by the amount you have select Press PROG while you are programming a phone number such as if you want to enter a pause period after 123 while calling telephone number 1234567 you need
24. to program the phone number as 123 PROG 4567 Multiple pause periods can be inserted within one telephone number Pick up Pause is useful when you know you will be calling something like an answering machine where after the phone is picked up you don t want the emergency message to playback immediately Therefore you would program a pause after the line is picked up To insert a picked up pause press the amp button The pick up pause duration is programmable Please refer to advanced programming Only one pick up pause can be programmed within one telephone number To program additional phone numbers follow the above procedures by selecting a different phone number locations from 1 to 9 You may review a programmed phone number by following the same procedures as programming a phone number Simply press 41 when the display shows the current setting instead of entering a new value allows you to keep the programmed setting To erase a phone number from the Dial Alert press PROG after step 3 above That is after you select the phone number from 1 9 Dial Alert will show the programmed phone number Pressing PROG now will delete this phone number from the memory PROGRAM AN ALARM PANEL Model SC 001 UNDER SC 001 OPERATING MODE You may use the Dial Alert to notify you when there is a break in or during an panic situation You need to program a panic signal from SC 001 Control Panel To program a Control Panel SC 001
25. to the Dial Alert follow the instructions below 14 STANDARD PROGRAMMING 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 5 which represents programming a device You will see P5 Id codE 3 Enter the Master Pin on the SC 001 then B B 4 After programming the display will show rEAdy indicating it is now in standby mode PROGRAM A SENSOR UNDER SENSOR OPERATING MODE You may use the Dial Alert to notify you when there is a sensor activation You need to program the sensor signal to the Dial Alert follow the instructions below 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter 5 which represents programming a device You will see P5 Id codE 3 Activate the sensor so it sends an activation signal to the dialer 4 Display shows Id PLAy enter the number of voice message you have recorded from 1 to 6 When this sensor is activated it will playback the main voice message and the selected secondary message If you enter 0 no secondary message will be played Press 41 for the dialer to accept your sensor 5 After programming the display will show rEAdy indicating it is now in standby mode To program more devices to the Dial Alert follow the instructions above You may progra
26. transmission with microcontroller 12V alkaline battery included Flood Sensor FS 101 Place sensor along basement wall near water heater washing machine etc 3V lithium battery included 24 ADDITIONAL ACCESSORIES Temperature Sensor TS 101A Monitors temperature of a specific area i e greenhouse horse farms laboratory etc Activates Security Control Panel SC 001 or Emergency Dialer AD 105 when the tempera ture of the monitored area is above or below a preset temperature Temperature range 3 F 19 C to 157 F 69 C Operates using lithium batteries included Keypad Control KP 434 Functions as an external keypad or secondary control location Use the keypad to arm disarm the Audio Alarm AA 433 Eliminates the need to walk through your premises to your Security Systems Control Panel Operates using lithium batteries included Water Resistant Panic Button Transmitter PT 434 Activates Security Control Panel and Emergency Dialer by pressing the panic button when under duress Ideal for Seniors physically challenged Water resistant carry transmitter all the time Operates using lithium batteries included Remote Panic Button Transmitter HW 434 Wrist watch style Activates Security Control Panel and Emergency Dialer by pressing the panic button when under duress Ideal for Seniors physically challenged Water resistant carry tran