Home

Hilti 2004789 Use and Care Manual

image

Contents

1. ronment Most of the materials from which Hilti tools or appliances are manufactured can be recycled The materials must be correctly separated before they can be recycled In many countries Hilti has already made arrangements for taking back old tools and appliances for recycling Ask Hilti cus tomer service or your Hilti representative for further infor mation For EC countries only Disposal of electric tools together with house hold waste is not permissible In observance of European Directive 2002 96 EC on waste electrical and electronic equipment and its implementation in accor dance with national law electric tools that have reached the end of their life must be collected Separately and returned to an environmentally compatible recycling facility Dispose of the batteries in accordance with national regulations 11 Manufacturer s warranty tools Hilti warrants that the tool supplied is free of defects in mate rial and workmanship This warranty is valid so long as the tool is operated and handled correctly cleaned and serviced properly and in accordance with the Hilti Operating Instruc tions and the technical system is maintained This means that only original Hilti consumables components and spare parts may be used in the tool This warranty provides the free of charge repair or replace ment of defective parts only over the entire lifespan of the 23 tool Parts requiring repair or replace
2. tool 3 Close the battery compartment cover 4 Check to ensure that the battery compartment cover is closed securely 6 2 Switching the tool on off 1 The tool can be switched on by pressing either the On off button or the Measure button 2 When the tool is switched off press the On off but ton The tool switches on The laser beam is switched off 18 3 When the tool is switched on press the On off but ton The tool switches off 4 When the tool is switched off press the Measure but ton The tool and the laser beam switch on 6 3 First distance measurements Press the Measure button once If switched off the tool will be switched on and the laser len beam activated If the tool is already switched on the laser beam will be activated 2 Aim the tool by positioning the visible laser spot on a white surface at a distance of approx 3 10 m 3 Press the Measure button again The distance will be displayed in less than a second e g 5 489 m You have just taken your first measurement with the tool _ 6 4 Settings menu 1 With the tool switched off press the On off button for approx 2 seconds to enter menu mode 2 Press the Measure button to switch the beep signal on or off 3 Press the On off button to access the measuring units settings 4 Press the Measure button repeatedly to scroll through the choice of units 5 To close the me
3. HT PDS 5 D 115 h en e 5 zu mh lt l SE ES ORIGINAL OPERATING INSTRUCTIONS PD 5 laser range meter It is essential that the operating instructions are read before the laser range meter is len used the first time Ensure that the operating instructions are with the laser range meter when it is given to other persons Contents Page 1 General information 13 2 Description 14 3 Accessories 15 4 Technical data 15 5 Safety instructions 16 6 Before use 18 7 Operation 19 8 Care and maintenance 20 9 Troubleshooting 22 10 Disposal 23 11 Manufacturer s warranty tools 23 12 EC declaration of conformity 24 These numbers refer to the corresponding illustrations The illustrations can be found on the fold out cover pages Keep these pages open while studying the operating instruc tions In these operating instructions the designation the tool always refers to the PD 5 laser range meter Parts operating controls and indicators D Laser emitting and receiving lens 2 On off button 3 Measure button Battery compartment cover Graphic display 1 General information 1 1 Safety Notices and their meaning CAUTION This word indicates a possibly hazardous situation which could result in slight bodily injuries or damage to property NOTE This word indicates information to help the user employ the prod
4. ment as a result of nor mal wear and tear are not covered by this warranty Additional claims are excluded unless stringent national rules prohibit such exclusion In particular Hilti is not obligated for direct indirect incidental or consequential damages losses or expenses in connection with or by reason of the use of or inability to use the tool for any purpose Implied warranties of merchantability or fitness for a particular purpose are specifically excluded For repair or replacement send tool or related parts imme diately upon discovery of the defect to the address of the local Hilti marketing organization provided This constitutes Hilti s entire obligation with regard to war ranty and supersedes all prior or contemporaneous com ments and oral or written agreements concerning warranties 12 EC conformity Designation Laser range meter Type PD 5 Year of design 2010 We declare on our sole responsibility that this product complies with the following directives and standards EN 50081 1 EN 61000 6 2 2004 108 EC Hilti Corporation Zoster la Has Dietmar Sartor Matthias Gillner Head of BA Quality and Process Management Executive Vice President Business Area Electric Tools amp Business Area ElectricTools amp Accessories Accessories 10 2010 10 2010 24 Hilti Corporation LI 9494 Schaan Tel 423 234 2111 Fax 423 234 29 65 www hilti com OO TT Hilti regi
5. mpatibility Although the tool complies with the strict requirements of the applicable directives Hilti cannot entirely rule out the possibility of the tool being subject to interference caused by powerful electromagnetic radiation leading to incorrect operation Check the accuracy of the tool by taking mea surements by other means when working under such con ditions or if you are unsure Likewise Hilti cannot rule out the possibility of interference with other devices e g air craft navigation equipment The tool complies with the requirements of class A The possibility of interference occurring in a domestic environment cannot be excluded 5 4 General safety rules a Check the condition of the tool before use If the tool is found to be damaged have it repaired at a Hilti ser vice center b The user must check the accuracy of the tool after it has been dropped or subjected to other mechanical stresses c Although the tool is designed for the tough conditions of jobsite use as with other measuring instruments it should be treated with care d Although the tool is protected to prevent entry of damp ness it should be wiped dry each time before being put away in its transport container 5 5 Electrical a Keep the batteries out of reach of children b Do not allow the batteries to overheat and do not expose them to fire The batteries may explode or release toxic substances c Do not charge the batteries 17 d Do
6. nce is measured along a laser beam emitted by the tool to the point at which the beam strikes a reflective surface The target from which the measurement is taken is clearly identified by the red laser measuring spot The range of the tool depends on the reflectance and structure of the target surface from which measurements are taken len 2 5 Control panel On off button When the tool is switched off press the button briefly to switch it on When the tool is switched off press and hold the button to activate the menu When the tool is switched on press the button briefly to switch it off Measure button Quick start When the tool is switched off Press the button briefly the tool switches on and activates the laser Begins distance measurement Activates the laser beam Activates continuous measuring mode long press approx 2 sec Stops continuous measuring mode 2 6 Items supplied 1 PD 5 laser range meter 2 Batteries 1 Soft pouch 1 Operating instructions 1 Manufacturer s certificate 3 Accessories Not supplied with the tool Target plate PDA 50 with reflective coating 120x130 mm PDA 51 120x130 mm PDA 52 with reflective coating 210x297 mm Laser visibility glasses PUA 60 4 Technical data Right of technical changes reserved Power supply 2x1 5 V type AAA batteries Battery condition check Battery condition indicator with 4 segments showing 100 75 50 25 charge No segments sh
7. not solder the batteries into the tool e Do not discharge the batteries by shortcircuiting This may cause them to overheat and present a risk of per sonal injury burns f Do not attempt to open the batteries and do not sub ject them to excessive mechanical stress g Do not use carbon zinc batteries in the tool 5 6 Laser classification Depending on the version purchased the tool complies with Laser Class 2 in accordance with IEC825 1 2007 EN60825 1 2007 and Class II in accordance with CFR 21 1040 FDA This tool may be used without need for fur ther protective measures The eyelid closure reflex pro tects the eyes when a person looks into the beam unin tentionally for a brief moment This eyelid closure reflex however may be negatively affected by medicines alco hol or drugs Nevertheless as with the sun one should not look directly into sources of bright light Do not direct the laser beam toward persons 5 7 Transport Always remove the batteries before shipping the tool 6 Before use fa 6 1 Inserting the batteries CAUTION Do not use damaged batteries CAUTION Always replace the complete set of batteries DANGER Do not mix old and new batteries Do not mix batteries of different makes or types 1 Open the battery compartment 2 Remove the batteries from the packaging and insert them in the tool NOTE Check to ensure correct battery polarity refer to the markings on the underside of the
8. nt the distances are updated in the result line by about 8 to 15 measurements every sec ond This depends on the reflectivity of the target surface Continuous measurement is indicated by a Beep The mea Suring process is stopped by pressing the Measure key once again On doing so the last valid distance measure ment shows in the result line on the display 8 Care and maintenance 8 1 Cleaning and drying 1 Blow dust off the lens 2 Do not touch the lens with the fingers 3 Use only a clean soft cloth for cleaning If necessary moisten the cloth slightly with pure alcohol or a little water NOTE Do not use any other liquids as these may damage the plastic components 4 The temperature limits for storage of your equipment must be observed especially in winter summer 8 2 Storage Remove the tool from its case if ithas become wet The tool its carrying case and accessories should be cleaned and dried at maximum 40 C Repack the equipment only once it is completely dry Check the accuracy of the equipment before it is used after along period of storage or transportation Remove the batteries from the tool before storing it for a long period Leaking batteries may damage the tool 8 3 Transport Use the original packaging or packaging of equivalent qual ity for transporting or shipping your equipment CAUTION Always remove the batteries before shipping the tool 20 8 4 Calibration and adjustment 8 4 1 Calibra
9. nu press and hold the On off button for approx 2 seconds The tool is switched off and all the settings shown will be saved 6 5 Measuring references All measurements taken with the PD 5 have the bottom end of the tool as the default reference setting 6 6 Measuring distances Distances can be measured from all stationary targets with out a highly reflective surface i e concrete stone wood plastic paper etc The use of prisms or other highly reflec tive targets is not permissible and if attempted may fal sify the results 7 Operation 7 1 Distance measurements NOTE With all functions of the tool each step in the operation is always indicated in the display 19 NOTE If measuring errors occur during continuous measuring and continuous measuring mode is canceled by pressing the Measure button again the last valid measurement will be displayed 7 2 Single distance measurement 1 Switch on the laser beam by pressing the Measure key 2 Press the Measure key once again Generally the mea Sured distance will be completed in less than a second and shown in the result line on the display 7 3 Continuous measurement Press the Measure key for 2 seconds to activate this mea Suring mode When doing so it does not matter whether or not the range meter is off or the laser beam is switched on or off The range meter will always switch to continuous measurement During continuous measureme
10. own The batteries are exhausted Measuring range with target plate 0 2 70m Accuracy Typically 1 5 mm for single and continuous measurement Atmospheric influences interfere with distance measurements Over long distances an influence of 1 5 mm 20 ppm of the measured distance is to be expected Typical accuracy 2 Sigma at 25 C Basic operating modes Single measurement Continuous measurement Display Illuminated liquid crystal display showing distance operating and battery status Laser class Visible 635 nm Output power less than 1 mW Laser class 2 EN 60825 1 2007 IEC 60825 1 2007 CFR 21 8 1040 FDA Automatic cut out Laser 1 min Tool 10 min Battery life Up to 8000 measurements at room temperature Operating temperature range 10 C 50 C Storage temperature 30 C 70 C Protection class IP 55 protection against dust and water jets IEC 529 Weight with batteries 100g Dimensions 164 L x 33 W x 21 H mm 5 Safety instructions In addition to the information relevant to safety given in each of the sections of these operating instructions the following points must be strictly observed at all times 5 1 Basic information concerning safety a Do not render safety devices ineffective and do not remove information and warning notices b Keep laser tools out of reach of children c Failure to follow the correct procedures when opening the tool may cause emission of lase
11. r radiation in excess of class 2 Have the tool repaired only at a Hilti ser vice center d Modification of the tool is not permissible e Check that the tool functions correctly each time before use f Measurements taken from surfaces with low reflectiv ity in highly reflective surroundings may be inaccurate g Measurements taken through panes of glass or other objects may be inaccurate 16 h Rapidly changing conditions e g persons walking through the path of the laser beam falling snow etc may lead to incorrect measurements i Do not point the tool toward the sun or other powerful light sources j Take the influences of the surrounding area into account Do not use the tool where there is a risk of fire or explo sion 5 2 Proper organization of the workplace a Avoid unfavorable body positions when working from ladders Make sure you work from a safe stance and stay in balance at all times b When the tool is brought into a warm environment from very cold conditions or vice versa allow it to become acclimatized before use c As a precaution check the previous settings and adjust ments you have made d Secure the area in which you are working and take care to avoid directing the beam towards other per sons or towards yourself when setting up the tool e Use the tool only within its specified limits f Observe the accident prevention regulations applica ble in your country 5 3 Electromagnetic co
12. s too dark 3 4 Bright sunlight towards the tool 4 1 Temperature too high gt 50 C 4 2 Temperature too low lt 15 C 5 1 Insufficient reflected laser light 6 1 Hardware fault Remedy 1 1 Replace the batteries 1 2 Insert the batteries correctly and close the battery compartment cover 1 3 Return the tool to Hilti for repair 2 1 Press the Measure button 2 2 Return the tool to Hilti for repair 3 1 Measure from the other direction sun from behind 3 2 Take measurements from less shiny surfaces 3 3 Use the PDA 50 PDA 51 PDA 52 target plate 3 4 Use the PDA 50 PDA 51 PDA 52 target plate 4 1 Allow the tool to cool down 4 2 Allow the tool to warm up 5 1 Observe the minimum measuring distance gt 200 mm from the front edge of the tool clean the lenses take the measurement from a different surface or use a target plate 6 1 Switch the tool off and on again If the fault persists contact Hilti Service 22 10 Disposal WARNING Improper disposal of the equipment may have serious consequences The burning of plastic components generates toxic fumes which may present a health hazard len Batteries may explode if damaged or exposed to very high temperatures causing poisoning burns acid burns or environmental pollution Careless disposal may permit unauthorized and improper use ofthe equipment This may result in seriou personal injury injury to third parties and pollution of the envi
13. stered trademark of Hilti Corp co Schaan W 3917 1210 00 Pos 1 OD 1 Printed in Liechtenstein 2010 Right of technical and programme T changes reserved S E amp 0 31 981 8 A MM
14. tion Monitoring of measuring equipment for users certified in accordance with ISO 900X As specified in ISO 900X you may carry out the inspection and testing of the PD 5 laser range meter yourself see ISO 17123 4 Field procedures for testing geodetic and surveying instruments Part 4 Elec tro optical distance meters 1 Select a readily accessible measuring distance of a known length approx 1 to 5 meters 3 to 15 feet which does not change over time and measure the same distance 10 times 2 Determine the mean deviation from the known distance This value should be within the specified accuracy toler ance for the tool 3 Keep a record of this value and note the date when the next test is due Repeat this test at regular intervals as well as before and after important measuring tasks Apply atest and inspection confirmation sticker to the PD 5 and keep a record of the entire monitoring test and inspection procedure and the results Please refer to the technical data contained in the operat ing instructions and the information concerning measur ing accuracy 8 4 2 Adjustment To ensure that the laser range meter is adjusted correctly we recommend that it is returned to a Hilti Service Center for calibration Accurate adjustment of the tool will be con firmed by a calibration certificate 8 4 3 Hilti calibration service We recommend that the tool is checked by the Hilti calibra tion service at regular intervals in order
15. to verify its reliabil ity in accordance with standards and legal requirements Use can be made of the Hilti calibration service at any time but checking at least once a year is recommended The calibration service provides confirmation that the tool is in conformance on the day it is tested with the specifi cations given in the operating instructions The tool will be readjusted if deviations from the manufacturer s specifica tion are found After checking and adjustment a calibration Sticker applied to the tool and a calibration certificate pro vide written verification that the tool operates in accordance with the manufacturer s specification Calibration certificates are always required by companies certified according to ISO 900x Your local Hilti Center or representative will be pleased to provide further information 21 9 Troubleshooting Fault 1 The tool can t be switched on 2 No distances displayed by the tool 3 Frequent error messages or the tool doesn t measure 4 Temperature indicator symbol in the display 5 Unfavorable signal conditions symbol in the display 6 General hardware fault symbol in the display Possible cause 1 1 The batteries are exhausted 1 2 Incorrect battery polarity 1 3 The button is faulty 2 1 Measure button was not pressed 2 2 Faulty display 3 1 The target surface is too brightly lit by the sun 3 2 The target surface is too shiny 3 3 The target surface i
16. uct efficiently and other useful notes 13 1 2 Explanation of the pictograms and other information Warning signs General warning Symbols CAUTION LASER RADIATION DO NOT STARE INTO BEAM h 7 620 690nm 0 95mW max N CLASS II LASER PRODUCT Laser class II according Read the Temperature Do notlook to CFR 21 1040 FDA operating indicator into the beam instructions before use AI Laser class2 Return waste Battery status Hardware Unfavorable material for indicator errors operating recycling conditions 1 3 Location of identification data on the range meter The type designation and serial number can be found on the rating plate on the back side of the range meter Make a note of this data in your operating instructions and always refer to it when making an enquiry to your Hilti representative or service department Type Serial no 2 Beschreibung 2 1 Intended use The range meter is designed for the e Measurement of distances 2 2 Display The measurements settings and tool status are shown in the display When the tool is in measuring mode the mea surements taken are shown at the bottom of the display area the result line 2 3 Display illumination In low light conditions the display is illuminated automat ically as soon as a button is pressed If no button is pressed over a period of 20 seconds the display illumination switches off automatically 14 2 4 Basic principle The dista