Home
Kwikset 910 TRL ZW 11P SMT CP Instructions / Assembly
Contents
1. 61019 02 SMARTCODE EW Installation Guide Required Tools N A Use and programming instructions are located on the Additional Tools depending on application N reverse side of this document f E Adjust the backset of latch if needed Hold the latch in front of the If the latch holes are door hole with the latch face centered in the door hole no flush against the door edge adjustment is required Proceed to step 4 If the latch holes are NOT centered adjust latch See Latch Adjustment Latch Adjustment only if needed Make sure turnpiece is N in the vertical 0 position Lact Do not install Ensure correct polarity For best results battery pack yet use new non rechargeable Alkaline batteries only 11 Install strike Parts in the Box Latch and Strike Exterior Assembly Interior Assembly If needed please contact Kwikset to order a drive in latch for your lock H Select models only Kwikset 1 866 863 6584 RZ S z www kwikset com jp 4 Install latch For doors with chiseled edge For doors without chiseled edge f 0 A2 Up a Ds E Z Wave locks only Perform the Inclusion process Inclusion refers to the process in which the lock is added to a Z Wave or ZigBee controller ZigBee locks Perform the Inclusion process after installation is complete See Z Wave and ZigBee
2. Systems on the reverse side of this document Hold the interior assembly a maximum of 12 305 mm from your Z Wave controller and initiate the Inclusion process at the controller Refer to your Z Wave control system instructions for more information Press button A on the lock one time to include it in your system The controller and lock must remain stationary for a total of 60 seconds during the Inclusion process Z Wave t Controller If Inclusion is unsuccessful initiate the Exclusion process at the controller then press button A on the lock one time Once the lock is fully excluded from the system repeat the Inclusion process 12 Program the lock Programming instructions are located on the reverse side of this document E Check dimensions 2 3 8 60 mm or 9 3 4 70 mm I ON rt Additional door preparation may be required for doors with 1 1 2 38 mm holes Consult the drilling instructions at www kwikset com doorprep 5 Prepare exterior keypad 1 3 8 1 3 4 35 mm 44 mm Service kits for 2 1 4 57 mm thick doors are available through Kwikset For doors with 2 1 8 54 mm holes a aft ca E RF Select models only ball 2 tp YR 3x amp i Keep S in a safe place as you will need it to access the back panel for additional programming Lay cable flat against the interior housing Sb ox he I
3. ased on building construction and communication path with 35 feet being typical installed distance in a standard home environment and 250 feet when the lock has a clear line of sight with the network controller It may be necessary to install additional ZigBee devices to enhance the communication path between the lock and controller for a more robust ZigBee network In order to fully utilize this product you must have a Z Wave controller compatible with door locks Z Wave is a Wireless mesh network and results may vary based on building construction and communication path with 35 feet being typical installed distance from network controller It may be necessary to install additional Z Wave beaming capable devices that can serve as repeaters to enhance the communication path between the lock and controller for a more robust Z Wave network Enabling and Adding a Mastercode Optional for Enhanced Security User codes can be programmed with or without a mastercode Using a mastercode is an optional added security measure It is not enabled by default A mastercode is used to add and delete user codes but it cannot unlock the door unless the same code is programmed as a user code though this is not recommended The mastercode must be 4 8 digits 1 Press and HOLD Program button until keypad flashes green about 5 seconds How the Keypad Works Each button represents two numbers i e 1 and 2 for the first button You only need
4. cal means or evaded by entry elsewhere on the property No lock can substitute for caution awareness of your environment and common sense Builder s hardware is available in multiple performance grades to suit the application In order to enhance security and reduce risk you should consult a qualified locksmith or other security professional 2014 Kwikset Corporation
5. en and then press the Program enabled before trying to button once If you don t disable it Attempt this procedure again making immediately hear three beeps or see the keypad sure to enter the same flash green three times the mastercode in steps 3 mastercode is disabled and 5 Note The lock will time out after five seconds If no button is pressed for five seconds the system will time out and you will need to restart the procedure between 4 and 8 digits during your next attempt Make sure to enter a valid mastercode in step 2 A TEST CODE Timeout Behavior Switch 3 ON Switch 3 OFF Mastercode red ae red ae enabled x6 ie O 08 x6 nie Mastercode red Do NOT enabled h 02 3 eie If switch 3 is ON g Regulatory Compliance This product complies with standards established by the following regulatory bodies e Federal Communications Commission FCC e Industry Canada FCC This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential insta
6. er codes are programmed the Lock button will be disabled Incorrect Codes Codes Entered Lock Behavior Next Step Keypad flashes red three times with three beeps Re enter cuge One incorrect code entered Three incorrect codes entered within one minute Keypad flashes red 15 times with 15 beeps If switch 3 is ON ie Z Wave amp ZigBee Systems Lock Inclusion Inclusion refers to the process in which the lock is added to a Z Wave or ZigBee controller Z Wave Perform the Inclusion process during lock installation See step 8 in the Installation Guide ZigBee Initiate the Inclusion process at your ZigBee controller Refer to your control system instructions for more information Unsuccessful ZigBee Inclusion Press button B nine times Repeat the inclusion process Lock Exclusion Exclusion refers to the process in which the lock is removed from a Z Wave or ZigBee controller Initiate the Exclusion process at your Z Wave or ZigBee controller Refer to your control system instructions for more information Re enter code after 60 second keypad lockout Use the chart to determine which button to press during Inclusion and Exclusion System Inclusion Exclusion Z Wave Press button A once Press button A once ZigBee Press button A four times Press button B nine times System Notes Z Wave ZigBee ZigBee is a Wireless mesh network and results may vary b
7. f www kwikset com pe T Edge Face E E D 2 l S ge l T P N r Centerline __48 _ a___ B 2 3 8 60 mm 2 3 4 70 mm Backset 61019 02 Kwikset I n l O m Z W User Guide Kwikset 1 866 863 6584 www kwikset com Troubleshooting and FAQs Installation instructions are are available online at located on the reverse side www kwikset com of this document D Programming Codes Programming Information b It is recommended that you add and delete all user codes through your Z Wave or ZigBee control system If your system does not allow this the sections below will provide instructions for how to add and delete codes at the lock User Codes Requirements Each user code must be a unique code between 4 and 8 digits depending on your control system A total of 30 user codes may be programmed A SmartCode at a Glance Exterior Note Although the arched 910 Interior cover removed model is illustrated instructions are the same for all 910 models Button A In Program 56 button Keypad 34 78 a Lock 12 90 button Status LED SmartKey Ea i Keyway tool hole Turnpiece B Normal Operation Unlocking the Door Enter user code Tip You can press the Lock button before entering your user code to light up the keypad at night Locking the Door Press Lock button once If no us
8. llation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help IMPORTANT Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Industry Canada This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Switches 809 ON OFF 123 4 Switch Function 1 Door lock status LED blinks every 6 seconds Lock automatically re locks door 30 2 seconds after un
9. locking Disabled if no codes are programmed 3 Audio 4 Not used Status LED Color Blinking green Blinking amber Blinking Red Solid Red Lock Status Unlocked Locked Low battery Door Handing Process did not work properly See online Troubleshooting guide F Switches Status LED Colors and Keypad Warnings Warning Keypad flashes red with fast beeping sound for3 4 seconds If switch 3 is ON 34 78 a 12 90 Reason Solution Low battery Relock door If Door jammed while attempting to lock strike No user code programmed Replace batteries needed reposition Program at least one user code A TEST CODE While the door is open test the user code to make sure it unlocks the door While the door is open test the user code to make sure it unlocks the door If no button is pressed for five seconds the system will time out and you will need to restart the procedure G Troubleshooting P Problem The latch bolt is not moving in the correct direction and the turnpiece will not rotate Reason The door handing process was not executed during installation and the lock does not know the orientation of the door Solution Perform the door handing process step 10 in the installation guide For more troubleshooting download the online Troubleshooting Guide available at www kwikset com H Factory Reset A factory reset will delete all codes associated with
10. nstall the battery cover and re key the lock ys SS If needed re key the lock to work with your existing key See the supplied SmartKey Re key instructions for more information A Extend latch bolt A A2 Q Route cable through center hole then push cable ii into side hole 6 Install keypad and mounting plate ter hol Cable goes con erno e underneath latch side hole Keep parallel to edge of door H Insert key and test latch el Pm If latch does not extend or s 5 T tract smoothly adjust TA Te Tighten o E i 4 screws Q ou NG Q DEON Remove key when finished Screws NOJ and make sure the latch evenly P gt bolt is fully extended 10 Perform door handing process This step will teach your lock the orientation of your door and is crucial to lock operation Press and hold the Lock button while installing battery pack L Did the latch bolt retract and extend on its own when the battery pack Hold button until the was installed latch bolt starts i S gt moving on its own YES NO HOLD Door handing process Remove battery pack was successful wait 15 seconds then Proceed to Step 11 attempt the process after latch bolt stops again latch bolt moving Template If your door requires drilling cut out the template and place it on the exterior side of the door Complete door drilling instructions are available on the SmartCode deadbolt page o
11. the lock 1 Remove battery pack t 3 Press the Program button once more When the LED flashes green and you hear one beep the lock has been reset o Important Safeguards 1 Read all instructions in their entirety 2 Familiarize yourself with all warning and caution statements 2 Press and HOLD the Program 8 i button while reinserting the 3 Remind all family members of safety precautions battery pack 4 Restrict access to your lock s back panel and routinely check Keep holding the button for your settings to ensure they have not been altered without your 30 seconds until the lock knowledge beeps and the status LED status LED 5 Protect your user codes and mastercode flashes red 6 Dispose of used batteries according to local laws and regulations A CAUTION Prevent unauthorized entry Since anyone with access to the back panel can change the user codes you must restrict access to the back panel and routinely check the user codes to ensure they have not been altered without your knowledge The use of a mastercode can help protect your system s settings 5 Perform the inclusion process again to add the lock back into your network and A controller 4 Perform the door handing process again See step 10 in the Installation Guide on the reverse side of this document WARNING This Manufacturer advises that no lock can provide complete security by itself This lock may be defeated by forcible or techni
12. to push the button once to get either 1 or 2 For example If your code is 1 2 5 6 8 1 12 Programming Behavior Successful Programming 2 5 6 8 12 56 56 78 The keypad will flash green once and you will hear one beep Unsuccessful Programming The keypad will flash red three times and you will hear three beeps Successful Programming 56 green 34 78 Timeout x1 HVOQ HB 12 dso x1 x3 Unsuccessful Programming 56 34 78 4 Re enter mastercode 2 Enter new mastercode 5 Press Lock button once IF UNSUCCESSFUL Make sure the mastercode has not been programmed already Attempt this procedure again making sure to enter the same new mastercode in steps 2 and 4 3 Press Lock button once A test Make sure switch 3 is on and then press the Program button once If you hear three beeps and see the keypad flash green three times the mastercode is enabled Note The lock will time out after five seconds If no button is pressed for five seconds the system will time out and you will need to restart the procedure s If no button is pressed for five seconds the system will time out and you will need to restart the procedure 1 Press the Program button Adding User Codes Mastercode NOT enabled the number of times that corresponds to the user code position being Mastercode enabled 1 Press Program button once The keypad will flash green and
13. you will hear three beeps programmed Example If programming the third code press the 2 Enter MASTERCODE button three times the code that was enabled in section b 2 Enter new USER code 3 Press Lock button once 4 Press the Program button the number of times that corresponds to the user code position being 3 Press Lock button once programmed Example If programming the third code press the button three times 5 Enter new USER code IF UNSUCCESSFUL 6 Press Lock button once Make sure the user code is not a duplicate and that it is between 4 and 8 digits during your next attempt IF UNSUCCESSFUL Make sure the user code is not a duplicate and that it is Deleting User Codes In order to delete a user code you must override the code by adding a different user code in the same position For example if you want to delete the third code add a different user code in position three A Test the old user code to make sure it is inactive If you cannot remember the user code position you may wish to perform a factory reset to delete all codes associated with the lock See section H Disabling and Deleting the Mastercode 1 Press and HOLD 3 Enter mastercode Program button until keypad flashes green about 5 seconds 2 Press Lock button once 4 Press Lock 5 Re enter 6 Press Lock IF UNSUCCESSFUL A TEST button once mastercode button once Make sure the Make sure switch 3 is on mastercode has be
Download Pdf Manuals
Related Search
Related Contents
Manuel d`Installation INGECON SUN 3Play TL M Copyright © All rights reserved.
Failed to retrieve file