Home
KISAE MW1210 Use and Care Manual
Contents
1. 4 PRODUCT DESCRIPTION viss seriar 5 INS TACCATION he 5 UNIT OPERATION ccia 41431414 9 TROUBLESHOOTING Sr 10 SPECIFICAHONS 11 WARRANTS 12 Page 3 INTRODUCTION Thank you for purchasing the KISAE Power Inverter With our state of the art easy to use design this product will offer you reliable service for providing AC power and 5V USB power for your home cabin RV or Trailer The KISAE Power Inverter can run many AC powered appliances when you need AC power anywhere The 5V USB power can charge many USB powered devices This manual will explain how to use this unit safely and effectively Please read and follow these instructions and precautions carefully IMPORTANT SAFETY INFORMATION This section contains important safety information for the KISAE Power Inverter Each time before using the KISAE Power Inverter READ ALL instructions and cautionary markings on or provided with the inverter and all appropriate sections of this guide The KISAE Power Inverter contains no user serviceable parts See Warranty section for how to handle product issues WARNING FIRE AND OR CHEMICAL BURN HAZARD e Do not cover or obstruct any air vent openings and or install in a zero clearance compartment WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS INJURY e When working with electrical equipment or lead acid batteries have someone nearby in case of an emergency e Study and follow all the battery ma
2. KISAE Modified Sinewave Power Inverter 1000 1500 MW 1210 MW1215 True Sinewave Power Inverter 1000 2000 SW 1210 SW 1220 Owner s Manual Modified Sinewave Series True Sinewave Series For safe optimum performance the Power Inverter must be used properly Carefully read and follow all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING statements PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Disclaimer While every precaution has been taken to ensure the accuracy of the contents of this guide KISAE Technology assumes no responsibility for errors or omissions Note as well that specifications and product functionality may change without notice Important Please be sure to read and save the entire manual before using your KISAE Power Inverter Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for future reference Product Numbers Modified Sinewave series MW 1210 Power Inverter 12V 1000W MW 1215 Power Inverter 12V 1500W True Sinewave series SW 1210 Power Inverter 12V 1000W SW 1220 Power Inverter 12V 2000W Document Part Number MU MW1215 Rev B Service Contact Information Email info kisaetechnology com Phone 1 604 320 7857 Web www kisaetechnology com T Page 2 fe Table of Contents INTRODUCTION ene a
3. Agency Markings gt Markings 0 us 2 y to 40 32 F to 104 Storage Temperature 20 C to 60 4 F to 140 Relative Humidity 5 90 noncondensing Operating Altitude Up to 9 843ft 3000 meters above sea level Weights and Dimensions MN 2 4 kg 3 1 2 7 kg 5 2 kg _____ Weights MW 1210 5 3 Ibs 2 4 kg MW 1215 6 9 Ibs 3 1 kg SW 1210 6 0 lbs 2 7 kg SW 1220 11 5 lbs 5 2 kg Dimensions MW 1210 12 3 x 6 9 x 3 4 31 2 x 17 5 x 8 7 cm MW 1215 15 0 x 6 9 x 3 4 38 2 x 17 5 x 8 7 cm SW 1210 12 6 x 6 9 x 3 4 32 1 x 17 5 x 8 7 cm SW 1220 16 3 x 9 1 x 4 3 41 4 x 23 0 x 11 cm Page 11 7 WARRANTY One Year Limited Warranty The limited warranty program is the only one that applies to this unit and it sets forth all the responsibilities of KISAE There is no other warranty other than those described herein Any implied warranty of merchantability of fitness for particular purpose on this unit is limited in duration to the duration of this warranty This unit is warranted to the original purchaser only to be free of defects in materials and workmanship for one year from the date of purchase without additional charge The warranty does not extend to subsequent purchasers or users Manufacturer will not be responsible for any amount of damage in excess of the retail purchase price of the unit under any circumstances Incid
4. 9 gt 94 sWi220 6 9 51 1220 9 1 SW1210 12 6 gt AA swi220 16 gt Power Inverter Chassis Grounding Connection DANGER The Power Inverter has chassis to be grounded properly Never operate the Power Inverter without properly grounded Failure to do so will result in death or serious injury e Connect the grounding cable s ring terminal to the unit ground screw Page 7 e Connect the other side of the cable to the common grounding point Power Inverter DC Input Connection CAUTION Reverse the DC Input terminal will damage the unit and cannot be repaired Damage caused by reverse polarity connection is not covered by the warranty Connect one end of the negative DC input cable to the Power Inverter DC negative terminal Connect the other end of the negative input cable to the battery negative terminal e sure the Disconnect Switch is in the OFF position e Connect one end of the positive DC input cable to the Power Inverter DC positive terminal Connect the other end of the positive DC input cable to one of the terminal of the Disconnect Switch e Connect a DC input cable between the other terminal of the Disconnect Switch and one side of the terminal of the fuse holder e Connect a DC input cable between the other terminal of the fuse holder and the battery positive terminal Install the selected fuse to the fuse holder e Disconnect Switch to ON
5. position Remote Switch optional Connection Insert the Remote Switch to the RJ11 Remote Port located the Front AC panel of the Power inverter Please note polarity Test the Power Inverter connection e unit by pressing and holding the On Off button on the main unit for about a second until a beep sound occur The Status light turns on indicating the KISAE Power Inverter is ON Check the digital display show measured battery voltage and output power alternatively Both AC output and 5V USB are now available Plug small AC load like 40W table lamp or small appliance to the AC socket to verify AC is available If AC is not available the may be tripped Reset the by pressing the RESET button The unit is successfully installed and functioning properly Test the GFCI monthly Use the following instruction to perform a monthly test on the GFCI to ensure the GFCI is functioning properly Turn unit on and plug a small AC load 40W light bulbs to the GFCI Check the AC load is ON Press Test button and observe a click sound Check AC load is turned off Press RESET button and check the AC load is back ON again Page 8 UNIT OPERATION WARNING RISK OF EQUIPMENT DAMAGE e For MW 1210 MW 1215 Do not plug surge protected power bars into the unit s 120 VAC outlets The surge protected components on the surge protected power bar may not like the modified sine wave
6. 0 AWG wire with maximum cable length of 5 feet For SW 1215 use minimum 2 0 AWG wire with maximum cable length of 5 feet Important The unit is grounded through the ground stud of the unit located near the DC Input Page 6 terminal For the grounding cable connected between the power inverter chassis to the earth ground use matching cable size as used on the DC Input Cable section Installing the Power Inverter System WARNING Electrical Shock Hazard The unit On Off switch does not disconnect the DC power from the battery Use the DC Disconnect Switch or disconnect the DC input cables connection to disconnect the DC power from the battery before working on any circuits connected to the unit Failure to follow these instructions can result in death or serious injury Power Inverter Installation Choose an appropriate mounting location e For indoor use the orientation of the unit can be mounted any direction except with the DC Input panel facing downwards e For RV installation the unit has to be mounted flat on horizontal surface Use mounting template below to mark the positions of the mounting screws Drill the 4 mounting holes and place the inverter in position and fasten the inverter to the mounting surface At mwi215 15 0 Av mwi210 12 3 gt 6 9 Bir i MW1210 12 3 MW1215 15 0 SW1220 16 3 SW1210 12 6 4 5 1210 9 1 swi2106
7. able protection Page 4 against harmful interference in residential installation This equipment generate uses and radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer an experienced radio TV technician for help LIMITATIONS ON USE Do not use in connection with life support systems or other medical equipment or devices PRODUCT DESCRIPTION The KISAE Power Inverter package includes the items list below e Power Inverter base unit one of the following models MW 1210 Power Inverter 1000 Modified Sinewave MW 1215 Power Inverter 1500 Modified Sinewave SW 1210 Power Inverter 1000 True Sinewave SW 1220 Power Inverter 2000 True Sinewave e Owner s manual P N MU MW1215 INSTALLATION WARNING KISAE Technology recommends that all wiri
8. ded for power inverter application For battery size you need to identify how much you will be using them between charges KISAE do recommends you purchase as much battery capacity as possible See more on Battery Run time and Load in Section 4 Fuse or Circuit Breaker DC rated fuse or DC rated circuit breaker connected along the DC positive line is required For MW 1210 SW 1210 select a fuse or circuit breaker with a minimum of 150 Adc For MW 1215 select a fuse or circuit breaker with a minimum of 225 Adc For SW 1220 select a fuse or circuit breaker with a minimum of 300 Adc Based on the size of the battery bank chosen on the 12V Battery Bank above determine the overall short circuit current rating of the battery bank from the battery manufacturer The fuse or circuit breaker chosen has to be able to withstand the short circuit current that may be generated by the battery bank Disconnect Switch e Select a Disconnect Switch with the same or higher the rating of the selected fuse or circuit breaker from the above Disconnect Switch is used to disconnect the DC power between the power inverter and the battery bank during service maintenance or trouble shooting DC Input and Grounding Cable Use of low resistance wire is required for all the DC connections between the inverter and the battery bank e For MW 1210 SW 1210 uses minimum 2 AWG wire with maximum cable length of 5 feet For MW 1215 use minimum 1
9. ental and consequential damages are specifically excluded from coverage under this warranty This unit is not intended for commercial use This warranty does not apply to damage to units from misuse or incorrect installation connection Misuse includes wiring or connecting to improper polarity power Sources RETURN REPAIR POLICY If you are experiencing any problems with your unit please contact our customer service department at info kisaetechnology com or Phone 1 604 320 7857 before returning product to retail store After soeaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a unit is returned more than 30 days but less than one year from the purchase date manufacturer will repair the unit or at its option replace it free of charge If the unit is repaired new or reconditioned replacement parts may be used at manufacturer s option A unit may be replaced with a new or reconditioned unit of the same or comparable design The repaired or replaced unit will then be warranted under these terms for the remainder of the warranty period The customer is responsible for the shipping charges on all returned items LIMITATIONS This warranty does not cover accessories such as adapte
10. ernal Turn unit off and wait for 15 minutes temperature was high and has before restarting Check if any object 05 7 shutdown has blocked the air flow of the unit Unit has sensed input voltage is low Recharge battery as unit will shutdown and warning occurs shortly E06 Unit has sensed load connected is Reduce load close to overload shutdown limit Not applicable for MW1210 MW1215 EO Unit has sensed internal Reduce load and check if any ventilation temperature is high and is close to of the unit is blocked thermal shutdown limit Load on Power Inverter Although the Power Inverter can provide high surge power up to two times the rated output power some appliances may still trigger on the inverter protection system higher power inverter is required for those appliances For MW 1210 1215 modified sinewave inverter some appliances like speed controllers found in some fans power tools and some power tools charger may not like the modified sine wave Page 9 generate by the inverter those appliances may not work or may be damaged if they connected to the inverter If you are unsure about powering any device with the inverter contact the manufacturer of the device Estimate Run time on Load Following run time is an estimate based on using a 12V 120AH battery bank for reference Actual run time may vary Load Estimate Run time Cordless Phone 180 hrs Clock Radio 135 hrs Table Lam
11. ng be done by a certified technician or electrician to ensure adherence to the applicable electrical safety wiring regulations and installation codes Failure to follow these instructions can damage the unit and could also result in personal injury or loss of life CAUTION Before beginning your KISAE Power Inverter Installation please consider the following e The KISAE Power Inverter base unit should be used or stored in an indoor area away from direct sunlight heat moisture or conductive contaminants e When placing the unit allow a minimum of three inches of space around the unit for optimal ventilation Understanding the unit features AC Output Front Panel Status Indicator 2 KISAE Power Inverter Output 97 isplay gt _ 2 On Off Switch pule 2 MR 00 Output Port for optional 2 p remote switch oot a _ Noo Sirusondal Output USB Output Picture shown MW1210 Page 5 1 DC Input Terminals opening Ground Terminal Picture shown MW1210 Material Prepare for Installation Typical Wiring block diagram of the Power Inverter Pos Power Inverter MW 1210 MW 1215 12 V Battery Bank SW1210 SW 1220 Charger system sold separately is required to charge the battery bank when battery is discharged 12V Battery Bank The use of deep cycle battery is highly recommen
12. nufacturer s specific precautions when installing using and servicing the battery connected to the inverter e Wear eye protection and gloves e Avoid touching your eyes while using this unit e Keep fresh water and soap on hand in the event battery acid comes in contact with eyes If this occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention e Batteries produce explosive gases DO NOT smoke or have an open spark or fire near the system e Keep unit away from moist or damp areas e Avoid dropping any metal tool or object on the battery Doing so could create a spark or short circuit which goes through the battery or another electrical tool that may create an explosion WARNING Shock Hazard Keep away from children e Avoid moisture Never expose unit to snow water etc e Unit provides 120 Vac treat the GFCI output socket the same as regular wall AC sockets at home WARNING Explosion hazard e DO NOT use the KISAE Power Inverter in the vicinity of flammable fumes or gases Such as propane tanks or large engines e AVOID covering the ventilation openings Always operate unit in an open area e Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit FCC INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reason
13. output generate by the inverter not connect AC power source like utility power or generator to the unit 120 VAC outlets Turn ON and OFF the 120 VAC and USB Press and hold the Power Select button for 1 second until a beep is sounded Display will show the measured battery voltage and output power alternatively Status LED will turn green Both 5V USB and 120 VAC are available Press Power Select button to turn unit off Remote ON OFF Optional e f optional remote is used the Remote ON OFF momentary switch is connected in parallel with the Power Select button on the unit Same procedure applies to ON and OFF the unit Understanding the Display amp Status LED Display 12 5 Display shows measured battery voltage 0 80 Display shows total output AC power in kW 800W as shown E01 Display shows error or warning code See trouble shooting section in details Status LED Green Unit operation is normal Amber Warning is detected Unit will shutdown at any time Please check error code to troubleshoot the unit Red Error is detected and unit has shutdown Please check error code to troubleshoot the unit Understanding the Error Code and has shutdown restart unit Kl TE and has shutdown charger is connected to the battery bank E Unit output has sensed overload or Check load connected to the output short circuit and was shutdown Reduce load and restart the unit 02 03 Unit has sensed int
14. p 40W 60W 27 hrs 18 hrs Freezer 8 8 cu ft 20 LCD TV 100W 11 5 hrs Refrigerator 18 cu ft 120W Sump Pump 1 2 hp 350W Microwave mid size 1000W 49 min Coffee Maker 1200W 5 TROUBLESHOOTING To trouble shoot the unit please note the error code display on the main unit and review the Understanding the Tempe Codes in section 4 Problem Symptom And Status LED is Section 4 to turn unit ON off No power to inverter Check fuse or the Disconnect switch i bor installed is either blown or turn OFF No AG output GFCI was tripped Check load and reset the Status LED is Green No Output Status Check error code on Verify the error condition and make LED is in Amber display correction Products Products connected to Products are not compatible with the connected to unit unit do not accept modified sine wave output generated by the malfunction or modified sine wave output KISAE Power Inverter See AC Load on overheat MW1210 amp MW1215 Power Inverter in Section 4 only Page 10 6 SPECIFICATIONS Note Specifications are subject to change without notices Specification Modified Sinewave Series p MW 1210 MW 1215 SW1210 SW 1220 _ Inverter Surge Power Peak 2000W 3000W 2000W 4000W 12 5 VDC DC Input Voltage operating range 10 5 15 5 VDC 2 fr 750 mA Safety and Environmental Conformance Conforms to UL 458
15. rs and batteries damage or defects result from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and maintenance fire and flood If your problem is not covered by his warranty call our Customer Service Department at info kisaetechnology com or 1 604 320 7857 for general information if applicable Page 12
Download Pdf Manuals
Related Search
Related Contents
Bulletin d`information Hippoclub n°. 34 CV-AbrahamFRANSSEN-2015 - copie - Université Saint Enterasys Matrix E1 Optical Access (1G694 Dissertation KitchenAid KERA807P Electric Kitchen Range アルミオイルプラグ 取扱説明書 SAT802S User Manual Soda Fresh Silverflash Bedienungsanleitung / instruction manual かんたん操作ガイド SVAT Electronics GX5203 User's Manual Copyright © All rights reserved.