Home

NewAir AC-10100E Use and Care Manual

image

Contents

1. indicator 12 High fan speed indicator 3 Fan ventilation mode indicator 13 Low fan speed indicator 4 Mode selection button 14 Fan speed ventilation button 5 Timer operation indicator 15 Sleep mode indicator 6 Timer button 16 Sleep button 7 Full water tank indicator 17 Compressor indicator 8 Temperature increase button 18 Temperature decrease button 9 Display window 10 Remote control receiver Turning the Unit On and Off 1 Press ON OFF button The unit will start automatically The default temperature is 75 F If the ambient temperature is Higher than 74 F 23 C the unit will work in cooling mode Higher than 68 F 20 C but below or equal to 74 F 23 C the unit will work in ventilation mode Below 68 F 20 C the unit will work in heating mode this is for cooling amp heating models only 2 Atthis time the indicator lights will show any functions that are in progress Please note that the display window will only show ambient room temperatures ranging from 32 F to 122 F 0 C to 50 C 3 To turn the unit off press ON OFF button again Setting the Model Function Press the MODE button to select the desired mode cooling fan or heating Setting Temperature lhe Zi Press Temperature up or Temperature down button to change the set temperature The display window will indicate the set temperature If not the temperature displayed will show the ambient room temperatu
2. unit 3 Measuring condition for the above specifications Cooling DB 95 F 35 C WB 82 94 F 28 3 C Heating DB 68 F 20 C WB 59 F 15 C D B dry bulb temperature room temperature W B wet bulb temperature relative humidity Reset Button If you plug in the Air Conditioner and there is no green light on the plug Test Button press the reset button on the LCDI plug The green light should be lit indicating that the air conditioner is getting power from the electrical outlet Green Light lf the plug continues to trip which is a USA national safety standard feature and the green light goes off the cord may be damaged preventing you from resetting the unit For your safety contact a licensed electrician 14 LIMITED MANUFACTURER S WARRANTY This appliance is covered by a limited manufacturer s warranty For one year from the original date of purchase the manufacturer will repair or replace any parts of this appliance that prove to be defective in materials and workmanship provided the appliance has been used under normal operating conditions as intended by the manufacturer Warranty Terms During the first year any components of this appliance found to be defective due to materials or workmanship will be repaired or replaced at the manufacturer s discretion at no charge to the original purchaser The purchaser will be responsible for any removal or transportation costs War
3. NewAir AC 10100E AC 10100H Portable Air Conditioner PLEASE READ AND SAVE THESE INSTRUCTIONS Owner s Manual Cit l I l l l i Ce BEFORE USE For safety reasons please read this manual carefully before operating We strongly recommend keeping this manual in a safe place for future reference e x ZNI GENERAL SAFETY A Do not use a damaged power cord B Do not clamp or bend the power cord C Always operate the unit in an upright position and place it on a flat level surface at least 14 inches away from any other object D Do not place in front of an open window E Do not bring in contact with chemicals F Do not place near a heat source G Do not immerse in water H Avoid areas where liquid can spill onto the unit l Do not place objects on or in the unit and do not cover or obstruct the inlet or outlet grills J Do not use an extension cord K Keep out of the reach of children L Never try to repair or dismantle the unit yourself Unauthorized repairs can void your warranty and endanger the user ELECTRICAL SAFETY This appliance is for indoor use only Always turn off the unit and unplug it when not in use Do not use this unit in excessively humid or wet environments Do not pull or place strain on the power cord when moving the appliance IF THE SUPPLY CORD IS DAMAGED IT M
4. UST BE REPLACED BY AN ELECTRICIAN OR SPECIALIZED TECHNICIAN AUTHORIZED BY THE MANUFACTURER IN ORDER TO PREVENT FIRE FOR MAXIMUM EFFICENCY Do not exceed the recommended room size Make sure doors and windows are closed while the portable air conditioner is in use Also keep curtains and blinds closed during the sunniest parts of the day while the air conditioner is in operation Frequently clean the portable air conditioner s filters Once the room or area has reached your desired comfort level be sure to reduce the unit s temperature and ventilation settings PARTS O oO Se SS p Control panel Air outlet Carrying handle Caster Cord storage Air filter Air inlet Exhaust air outlet Air inlet Rubber plug drainage point Hose adaptor goes over the hose and into the window kit Exhaust hose Extendable window kit Active carbon filter Drain tube for continuous drainage Remote control INSTALLATION Extendable window kit 1 Open the window and insert the window kit into the open gap 2 Close the window until the window kit is held securely You may need to adjust the size of the window kit and secure it with screws This technique may also be used for sash windows 3 Fit the exhaust hose into the exhaust air outlet located on the back of the air conditioner 4 Attach one end of the hose adapter onto the exhaust hose 5 Attach the other end of the hose ada
5. ill resume The heating system will turn off if the ambient temperature is higher than the set temperature The ventilation fan will continue operating at the set level Once the ambient temperature drops below the set temperature heating will resume This machine is equipped with ANTI FROST function When using the heating function in low temperature the heater will occasionally stop heating in order to melt any frost that has accumulated within the air conditioner Normal operation will resume in a few moments DRAINING THE UNIT During the cooling process some water will be extracted from the air and stored within the unit s water reservoir If the reservoir is full both the compressor and motor will stop and the unit will beep press any button to stop the beeping sound The full water tank indicator light will also start flashing To resume cooling empty the reservoir by following these steps 1 Turn off the air conditioner and unplug it _ n from the wall socket To prevent water SS SM leakage avoid moving the unit when full 2 Place a container such as a small pan underneath the drain hole 3 Remove the drain knob amp rubber plug from r the drain hole and allow the water to drain out oY 4 When the container is almost full replace N ae the rubber plug in the drain hole and empty ae ca i D the water tray Water holej i 5 Repeat until the unit
6. is emptied Rubber plug Drain knob 6 Replace the rubber plug and make sure it is firmly in place 7 Turn the unit back on The full tank indicator light should turn off For Continuous Drainage e Remove the drain knob and rubber plug ia Seer from the drainage port and hold on to them pe for future use Usesadlt lt o wA i ih e Connect the drain tube to the water outlet Water hole 3 as shown Place the other end of drain Rubber plug Drain knob tube into a drain 10 e The drain tube may be extended by adding an extension tube with a suitable connector ST NG PaA D rain tu b z Please Note 1 The drain must be at or below the level of the drainage port Original drain tube 2 The full water tank indicator light will not work when the unit is being continuously drained Extension tube 3 To extend the drain tube you can OD 0 7 connect it with another hose with an overall diameter of approximately 0 7 18mm 11 MAINTENANCE INSTRUC TIONS Always unplug the air conditioner from the power supply before cleaning To maximize the efficiency of the air conditioner regularly clean the unit Cleaning the Housing Use a soft damp cl
7. n direct sunlight If so close any curtains or move the unit to a more shaded area Are too many windows or doors open Are there too many people in the room Are there additional heat sources in the room Is the filter dusty or dirty Is the air inlet or air outlet blocked Is the ambient room temperature lower than the set temperature Is the machine positioned unevenly Make sure the air conditioner is positioned on an even solid surface It is possible the overheat protection of the compressor is on If so wait for the temperature to drop and then turn on the unit again vw NEVER TRY TO REPAIR OR DISMANTLE THE UNIT YOURSELF UNAUTHORIZED REPAIRS CAN VOID YOUR WARRANTY AND ENDANGER THE UNIT TECHNICAL SPECIFICATIONS Model Number AC 10100E AC 10100H Power Consumption 909W 8 3A 909W 8 3A Cooling Ower Consumption 909W 8 3A Heating Air Volume Max Speed 218CFM 355m h PENO CALON 2 11 pints hour Capacity Power Supply 115V 60Hz Compressor Type Rotary Refrigerant R 410A Please refer to the rating label Fan Speeds 2 1 12 hours Exhaust Pipe 5 x 59 06 127 x 1500mm 48 5 Ibs 22 kg Dimensions W x D x H 12 1 x 15 1 x 29 7 305 x 383 x 752 mm Notes 1 The heating function is only available in the AC 10100H model 2 The data marked with may vary for technical reasons for more accurate data please refer to the rating label found on the back of the
8. oth to wipe the body clean Never use aggressive chemicals gasoline detergents chemically treated cloths or other cleansing solutions These all could possibly damage the cabinet Cleaning the Filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters Rinse thoroughly under running water no hotter than 104 F or 40 C Thoroughly dry the filter before replacing it back into the unit PLEASE NOTE NEVER USE THE UNIT WITHOUT THE AIR FILTER End of Season Storage Completely drain any condensed water from the unit Set the air conditioner on fan made ventilation only for a few hours to dry the inside of the unit Clean or change the filter Unplug and store the power cord as shown Place the unit back in its original carton and store it in a clean dry area 12 FAULT CHECK LIST The air conditioner does not run The unit does not produce enough e cooling The unit does not cool at all J The unit is noisy The compressor does not work Is the air conditioner plugged in Is the power outlet functioning correctly Is the full water tank indicator light flashing Is the ambient room temperature lower than the set temperature Is the unit placed i
9. pter to the window kit Mounting of the Exhaust Pipe e Only use the hose provided and clip exhaust hose to the back of the air conditioner e Avoid kinks and bends in the exhaust hose This can cause moist air to accumulate causing the unit to overheat and shut down e The exhaust hose may be extended from 12 inches 300mm to 59 inches 1500mm but for maximum cooling efficiency use the shortest length possible WARNING The included exhaust hose is specifically designed to fit the specifications of this unit Do not extend it with your own hose as this can cause the air conditioner to malfunction Installation of the Carbon Filter filter frame activated carbon filter filter fixer into the back of Remove the activated carbon filter from its plastic bag frame the activated carbon filter should be placed between the filter frame and filter fixer firmly Attach the activated carbon filter to the Reattach the filter fixer onto the filter Separate the filter fixer from the filter filter frame C O 1 fe 2 fe 2 a 4 C gt O x Insert the filter set 2 3 4 5 6 BEBEBEER EEE ryt ig tie tt E Sa ie oe 1BB1IBRE Bee IERIE Bee LEB iBall Bae FIG 13 OPERATION Control panel X KU Y x 660 Q o DT o S 1 Automatic mode indicator 11 ON OFF power button 2 Cooling mode
10. ranty Exclusions The warranty will not apply if damage is caused by any of the following e Power failure e Damage in transit or when moving the appliance e Improper power supply such as low voltage defective household wiring or inadequate fuses e Accident alteration misuse or abuse of the appliance such as using non approved accessories inadequate air circulation in the room or abnormal operating conditions extreme temperatures e Use in commercial or industrial applications e Fire water damage theft war riot hostility or acts of God such as hurricanes floods etc e Use of force or damage caused by external influences e Partially or completely dismantled appliances Obtaining Service When making a warranty claim please have the original bill of purchase with purchase date available Once confirmed that your appliance is eligible for warranty service all repairs will be performed by a NewAir authorized repair facility The purchaser will be responsible for any removal or transportation costs Replacement parts and or units will be new re manufactured or refurbished and is subject to the manufacturer s discretion For technical support and warranty service please email support newairusa com 19
11. re Please note that the preset temperatures are as follows Cooling 75 F 24 C Heating 68 F 20 C Setting Fan Ventilation Speed i Press SPEED button to select the desired fan speed high or low The indicator light will display the fan speed selected lf the unit is in AUTO mode it will choose the ventilation speed automatically according to the ambient temperature the related indicators will light on In the AUTO mode the fan speed cannot be changed manually Setting Timer 1 Press TIMER button to set the desired number of operating hours from 1 to 12 hours When the set time has been reached the machine will turn off automatically The display window will show the hour s you set as you press TIMER button If the TIMER is not set the unit will work continuously By pressing the timer without turning on the other functions you can PRE SET the number of hours to be delayed before the unit turns on For example if you set the timer to 2 the unit will automatically turn on after 2 hours Sleep Function 1 When in cooling mode press the SLEEP button The set temperature will increase 2 F 1 C on the 1st hour another 2 F 1 C on the second hour and then maintain that temperature When in heating mode press the SLEEP button The set temperature will decrease 2 F 1 C on the 1st hour another 2 F 1 C on the second hour and then maintain that temperature In sleep mode the fan will a
12. utomatically be set to low By pressing the SLEEP button again the set temperature and fan speed will revert back to the previous setting The unit will shut down automatically after it has been in sleep mode for 12 hours Please note the sleep function is not available while the machine is working in AUTO or FAN ventilation mode It will only work in cooling or heating mode Heating Function For AC 10100H Only 1 When the air conditioner is in heating mode ambient warm air is recycled and used to heat your immediate area The exhaust pipe will still need to be fitted onto the unit in order for the cold air to be removed Continuous drain is compulsory while the unit is in heat mode Working range for heating function is 45 to 77 F 7 25 C If the ambient temperature is lower than this range the unit may not work properly All the functions can also be performed with the supplied remote control The remote control requires 2 AAA batteries to operate Regulating air flow direction Move the air vent directly to adjust the air flow direction of the louvers Please Note 1 To prolong the life of the compressor after turning off the unit please wait at least 3 minutes before turning it back on The cooling system will turn off if the ambient temperature is lower than the set temperature However the fan will continue operating at the set level Once the ambient temperature rises above the set temperature cooling w

Download Pdf Manuals

image

Related Search

Related Contents

BULLETIN DE VERSEMENT  取扱説明書  Samsung GT-S3030 Uživatelská přiručka  General description  ダウンロード  Le manuel recense les exigences pré analytiques du laboratoire. Le    取扱説明書    APC SMX1000 VA Power Supply User Manual  

Copyright © All rights reserved.
Failed to retrieve file