Home
Cadet CBC103TCH Installation Guide
Contents
1. ADJACENT WALL Figure 4 INSTALLATION INSTRUCTIONS continued Part Two After you have followed all instructions in Part One you are ready to install the heater assembly CB103T Multi Volt How do configure the Multi Volt model CB103 SIA Determine Supply Voltage Heater must be connected to a GFCI protected branch circuit Refer to wiring diagrams and Figure 6 for desired voltage Before installing the heater it is extremely important you verify the heater is configured for the correct supply voltage The Multi Volt Com Pak Bathroom Heater is configured for 240 volt operation by default For 120 volt installation you must reconfigure the heater wiring Installing the heater without configuring for the correct voltage will destroy the heater and void your warranty How to determine the supply voltage If replacing an existing heater check the labels of the old heater and replace using same voltage For new construction heater wires must be configured to the same voltage as the supply wires If you need assistance consult a qualified electrician SUE Select Proper Heater Voltage For 240 volt configuration The Multi Volt Com Pak Bathroom Heater is configured for 240 volt operation by default Important The red wire and its terminal end are not connected in this configuration For 120 volt Configuration To configure heater for 120 volt disconnect the blue wire from terminal D and connect it to ter
2. Los cables de suministro o del calentador que presentan cortocircuitos pueden ocasionar chispas peligrosas Revise el aislamiento de todos los cables de suministro y del calentador para comprobar que no est n da ados No reestablezca el cortacircuito sino hasta que se hayan reparado todos los cortocircuitos el ctricos 4 Reemplace el cortacircuito El ventilador del calentador funcio na pero no env a aire caliente 1 Temperatura insuficiente del elemento 2 Voltaje de suministro incorrecto 3 El elemento ha fallado 1 Espere unos momentos para que el elemento alcance la temperatura de funcionamiento 2 Compruebe que el voltaje de suministro coincida con la calificaci n del calentador 3 Reemplace el elemento El calentador no se apaga El calentador emite humo o un olor a quemado 1 La fuga de calor de la habitaci n es superior a la capacidad del calenta dor 2 El termostato no funciona cor rectamente o bien el temporizador supedit el ajuste 1 Se han acumulado polvo pelusas u otros materiales dentro del calentador 2 Conexiones el ctricas deficientes o sueltas 1 Cierre las puertas y ventanas Coloque aislamiento adicional o instale un calentador de may or vatiaje o m ltiples calentadores si fuera necesario Si su circuito tiene mayor capacidad 2 Espere que el temporizador termine su per odo o bien g relo en sentido contrario a las mane cillas del reloj a 0 el temp
3. nor authorizes anyone to assume for it any other obligation or liability in connection with its products other than as set out herein If you believe your Cadet product is defective please contact Cadet Manufacturing Co at 855 CADET US during the warrant period for instructions on how to have the repair or replacemen processed Warranty claims made after the warranty period has expired will be denied Products returned without authorization will be refused Parts and Service Visit cadetheat com parts service for information on where to obtain parts and service Reduce Reuse Recycle This product is made primarily of recyclable materials You can reduce your carbon footprint by recycling this product at the end of its useful life Contact your local recycling support center for further recycling instruc ions Page 5 MAINTAINING YOUR HEATER Maintenance As Needed or every six months minimum WARNING Before removing grill turn the electrical power off at the main disconnect panel circuit breaker or fuse box Lock or tag the main disconnect panel door to prevent someone from accidentally turning the power on while you are working on the heater Failure to do so could result in serious electrical shock burns or possible death NWARNING Any other service not detailed in this Owner s Guide should be performed by an autho rized service representative 1 It is important that you verify p
4. Built in Tim r Built in Thermostat 125 8 32 0cm y be 10 A 1 30m 25 4cm Wall Can Bottom 19 Ye laser sam LISTED TOOLS REQUIRED e Utility Knife e Phillips Screwdriver e 2 1 Wood Screws 7718 e Straight Screwdriver e 2 Insulated Wire Connectors Poem e Wire Strippers e 1 Strain Relief Connector SAVE THESE INSTRUCTIONS cadetheat com Tel 855 CADET US PO Box 1675 Vancouver WA 98668 1675 Page IMPORTANT INSTRUCTIONS A WARNING When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Read all instructions before installing or using this heater 2 A WARNING Risk of Fire This heater is hot when in use Caution High Temperature Risk of Fire Keep electrical cords drapery furnishings and other combustibles at least 3 feet from the front of the heater and 6 inches above and on both sides 3 A WARNING Burn Hazard To avoid burns do not let bare skin touch hot surfaces Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended 4 AWARNING A Risk of Electrical Shock Do not operate any heater after it malfunctions Disconnect power at service panel and have heater inspected by a qualified electrician before reusing 5 A WARNING Do not use outdoors
5. ELECTRICAL CODES TO DETERMINE WHAT WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL SERVICE PERSONNEL 1 Incorrect supply voltage 2 Overloaded circuit 3 A short circuit exists in the supply or heater wiring 4 Defective circuit breaker 1 Insufficient element tempera ture 2 Incorrect supply voltage 3 Element has failed 1 Heat loss from room is greater than heater capacity 2 Thermostat is not functioning properly or setting has been overridden by timer 1 Dust lint or other matter has accumulated inside heater 2 Poor or loose electrical connections 1 Defective motor or internal connection 2 Fan or motor jammed 1 Thermostat is set too low or in no heat position 2 Heater has tripped the manual high temperature reset switch 3 Power not on at the circuit breaker 4 Broken or poorly connected wire s to heater 5 Defective thermostat and or timer 1 Dust lint or other matter has accumulated inside heater 2 Airflow is blocked 3 Fan or motor is jammed 4 None of the above 1 Verify that supply voltage matches the heater rating 2 The total amperage of all heaters on a branch circuit must not be more than 80 of the amperage rating of the circuit breaker and supply wire ratings Use a lower wattage heater or reduce the number of heaters on the circuit 3 Shorted supply or heater wires may be accompanied by severe sparking Inspect all supply and heater
6. antes de volver a usarlo 5 4 ADVERTENCIA No lo use a la intemperie 6 Para desconectarlo ponga los controles en OFF y apague la alimentaci n del circuito del calentador en el panel de desconexi n principal 7 MADVERTENCIA A Riesgo de electrocuci n No introduzca ni permita que ingresen objetos en las aberturas de la ventilaci n o escape ya que ello puede causar electrocuci n o incendio o bien da ar el calentador 8 ADVERTENCIA Riesgo de incendio Para evitar posibles incendios no bloquee las tomas de aire ni el escape de manera alguna 9 AADVERTENCIA Podr an producirse explosiones o incendios Todo calentador contiene piezas que se calientan y pueden producir arcos voltaicos o chispas No lo use en reas donde se utilice o almacene gasolina pintura o vapores o l quidos inflamables 10 Use este calentador s lo como se describe en este manual Todo otro uso no recomendado por el fabricante puede causar incendios descargas el ctricas o lesiones personales 11 El calentador debe instalarse correctamente antes de usarlo 12 A ADVERTENCIA A Riesgo de electrocuci n e incendio No lo opere sin la rejilla 13 Conserve estas instrucciones Diagramas de cableado CB103T Voltaje M ltiple CB132T Multi Vatiaje Suministro de Alimentaci n de 240 Voltios Suministro de Alimentaci n de 120 Voltios Suministro de Alimentaci n de 240 208 Voltios TEMPORIZADOR TEMPORIZADOR TERM
7. consulte a un t cnico electricista calificado mse Seleccione el voltaje adecuado del calentador Para la configuraci n de 240 voltios El calentador Com Pak Bath est configurada para operar a 240 voltios de manera predeterminada Importante El alambre rojo y su extremo terminal no est n conectados en esta configuraci n Para la configuraci n de 120 voltios A fin de configurar el calentador para 120 voltios desconecte el alambre azul del terminal D y con ctelo al terminal A Luego conecte el alambre rojo suelto al terminal D Configuraci n Correcta de 240 Voltios Configuraci n Correcta de 120 Voltios Alambre Azul Alambre Blanco gt Alambre Blanco Alambre Negro gt Alambre Negro Alambre Rojo i Alambre Roja Alambre Azul Figura 6 Contin e con el PASO 3 CB132T Multi Vatiaje C mo se configura Vatiaje M ltiple modelo CB132 Configuraci n de cableado del elemento de PASO 1 vatiaje m ltiple El calentador se debe conectar a un circuito derivado con protec ci n GFCI Consulte la tabla de Figura 5 para seleccionar el vatiaje correcto necesario y los terminales del elemento que se han de usar 240 208V CONFIGURACI N DE ALAMBRES 800 600 Desconecte y corte el conector AZUL del terminal C Cubra el extremo del alambre suelto con cinta para uso el ctrico M
8. mediante los orificios que vienen en la c mara Como alternativa se puede a adir la cu a de caucho suministrada al costado de la c mara para cuadrarla con el puntal Consulte las Figuras 1 y 2 Contin e con la Parte Dos PARED ADYACENTE Figura 4 P gina 9 INSTRUCCIONES PARA LA INSTALACION continuaci n Parte Dos Una vez que ha seguido todas las instrucciones en la Parte Uno ya est preparado para instalar el conjunto del calentador CB103T Voltaje Multiple C mo se configura Multi Voltaje modelo CB 103 ASTON Determine el voltaje del suministro El calentador se debe conectar a un circuito derivado con protec ci n GFCI Antes de instalar el calentador es extremadamente importante verificar que est configurado para el voltaje de suministro cor recto El calentador Com Pak Bath est configurado de manera predeterminada para funcionar a 240 voltios Para la instalaci n a 120 voltios se debe reconfigurar el cableado del calentador Instalar el calentador sin configurarlo para el voltaje correcto destruir el aparato e invalidar la garant a C mo determinar el voltaje de suministro Si va a reemplazar un calentador existente revise las etiquetas del calentador antiguo y sustit yalo por otro del mismo voltaje Para una construcci n nueva los alambres del calentador se deben configurar de modo que coincidan con el voltaje de los alambres del suministro del inmueble Si necesita ayuda
9. to a higher temperature until heater operates See Problem 5 if the problem persists 2 Press the manual reset button See OPERATING INSTRUCTIONS section 3 Turn on the correct circuit breaker in the main disconnect panel 4 Turn off power at circuit breaker Check supply wire continuity and proper con nection to heater wires 5 Repair or replace the heater The entire heater or any of its components may be checked for continuity to determine the cause of any problem 1 Clean heater See MAINTAINING YOUR HEATER section for instructions 2 Remove obstruction Maintain a minimum distance of 6 inches from adjacent surfaces 4 inches from the floor and 3 feet for furniture or other objects placed directly in front of the heater 3 Remove obstruction and press heater manual reset button See OPERATING INSTRUCTIONS section 4 Replace heater assembly 2015 Cadet PrintedinUSA Rev 06 15 720050 CADETS Beneficios En Las Que Puede Confiar e La Mejor Alternativa para Su Ba o Calor r pido donde m s lo necesita Incluye temporizador de 60 minutos y termostato F cil de instalar Nuestro elemento de m xima resistencia brinda una agradable calidez durante muchos a os de uso confiable e Componentes con sentido com n dise ados pen sando en usted Sin bordes filosos Resistentes a la corrosi n C mara de pared f cil de instalar Seguro para usted y su familia Tranqu
10. wiring insulation for damage Do not reset the circuit breaker until all electrical shorts have been repaired 4 Replace the circuit breaker 1 Allow a few moments for element to reach operating temperature 2 Verify that supply voltage matches the heater rating 3 Replace element 1 Close doors and windows Provide additional insulation or install a higher wattage heater or multiple heaters if necessary If your circuit is rated for more capacity 2 Wait for the timer to time out or turn the timer counterclockwise to 0 The timer overrides the thermostat setting If heater continues to run adjust thermostat to its lowest setting If heater continues to run allow two minutes for thermostat to respond the thermostat requires replacement 1 Clean heater see MAINTAINING YOUR HEATER section above for instruc tions 2 Turn off power at circuit breaker Inspect all supply and heater wire connections to make sure nothing is loose or poorly connected Secure or reconnect all loose connections Do not reset circuit breaker until all connections have been checked and repaired 1 Heater or fan motor requires replacement 2 Remove obstruction and press heater reset button after allowing the unit to cool Test heater operation if reset button has been pressed be sure to listen and feel for a click indicating it has been reset but heater does not run heater requires repair or replacement 1 Adjust thermostat
11. 6 To disconnect heater turn controls to off and turn off power to heater circuit at main disconnect panel 7 AWARNING A Risk of Electrical Shock Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 8 AWARNING Risk of Fire To prevent a possible fire do not block air intakes or exhaust in any manner 9 WARNING Fire or explosion may occur A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable vapors or liquids are used or stored 10 Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electrical shock or injury to persons 11 The heater must be properly installed before it is used 12 AAWARNINGA Risk of Electrical Shock and Fire Do not operate without grill 13 Save these instructions Wiring Diagrams CB103T Multi Volt CB132T Multi Watt 240 208 Volt Power Supply a a 240 Volt Power Supply 120 Volt Power Supply TIMER THERMOSTAT ae oot ah JUMPER WITH 3 6 1 VV VV SPARETERMINAL MER CONNECTOR a i SHORTING BAR al 6 T 4 JUMPER WITH THERMOSTAT INSULATED Q D HEATING ELEMENT CONNECTOR MANUAL RESET HIGH TEMPERATURE LIMIT MANUAL RESET HIGH TEMPERATURE LIMIT 4 E MOTOR La e INSULATEDQD D ______ A SPARE TE
12. C A D E T cp Com Pak Bath Heater Owner s Guide Benefits You Can Depend On e Best Choice for Your Bathroom Com Pak Bath Multi Volt Model Quick heat where you need it most Line Model with Includes 60 minute timer and thermostat Weltau Thermostat 1 Watts Amps Easy to install and Timer f 120 CB1037 1000 8 3 e Our sturdiest element provides cozy warmth for aso a 000 ia years of reliable use Common sense components designed with you in mind No sharp edges Com Pak Bath Multi Watt Model k a Line Model with Corrosion resistant Voltage Thermostat 1 Watts Amps Easy to install wall can and Timer 500 2 1 e Safe for you and your family o 240 2 CB1327 200 Peace of mind with automatic high tempera o ture shutoff feature E 1 Standard built in thermostat is single pole with no heat position when turned Your Cadet heater has been thoroughly tested and completely counterclockwise Built in 60 minute timer overrides thermostat for instant is guaranteed with a limited 3 year warranty warmth 2 240 volt models can be used at 208 volts Wattage equals 75 of 240v rated e Two models for multiple room sizes and multiple wattage voltage applications Com Pak Bath Models with Built In Thermostat Wall Thermostat Not Required ESO Sos Reset Button o i Rating Label 00o 00o Q Side Grill Front Wall Can Side
13. Consulte la Figura 3 Empalme el alambre de conexi n a tierra del suministro al tornillo de puesta a tierra que viene en la c mara de pared Contin e con la Parte Dos CABLE DEL SUMINISTRO DESTAPADERO GIRE PARA IRARLO S TORNILLO DE CONECTOR DE PUESTA A TIERRA ALIVIO DE TENSI N C mo se instala el calentador en una pared existente TO Corte un orificio en la pared La distancia MINIMA REQUERIDA es de 6 pulgadas desde las superficies adyacentes y 4 pulgadas desde el piso Consulte la Figura 4 Sin embargo Cadet recomienda 12 pulgadas desde las superficies adyacentes y el piso para lograr un rendimiento m s prolongado y limpio Si se instalan varios calentadores deje al menos tres pies entre ellos Corte un orificio de 8 pulgadas de ancho por 10 de alto al lado del puntal de la pared OY Instalaci n de los cables de suministro Dirija el cable de suministro desde el cortacircuito GFCI a la c mara de pared Quite un destapadero y fije el cable de sum inistro mediante un conector de alivio de tensi n no incluidos dejando 6 pulgadas de cable de conexi n Consulte la Figura 3 Empalme el alambre de conexi n a tierra del suministro al tornillo de puesta a tierra que viene en la c mara de pared OJ Montaje de la c mara de pared Inserte la c mara de pared en la abertura manteni ndola alineada con la superficie de la pared Asegure la c mara al puntal de la pared con 2 tornillos no incluidos
14. D e Cuchillo Multiuso e 2 Tornillos de 172 para Madera e 2 Conectores de Alambres e 1 Conector de Alivio de Tensi n HERRAMIENTAS NECESARIAS e Destornillador Phillips e Destornillador Plano e Pelacables CONSERVE ESTAS INSTRUCCIONES cadetheat com Tel 855 CADET US PO Box 1675 Vancouver WA 98668 1675 P gina 7 INSTRUCCIONES IMPORTANTES MADVERTENCIA Al utilizar artefactos el ctricos siempre se deben adoptar precauciones b sicas para reducir el riesgo de incendios electrocuci n y lesiones personales incluyendo lo siguiente 1 Lea todas las instrucciones antes de instalar o usar este calentador 2 A ADVERTENCIA Riesgo de incendio Este calentador se calienta mucho cuando est en uso Precauci n Alta temperatura Riesgo de incendio Mantenga los cables el ctricos cortinas muebles y dem s materiales combustibles a por lo menos 3 pies por delante y a 6 pulgadas por encima y por ambos costados del calentador 3 A ADVERTENCIA Riesgo de quemaduras Para evitar quemaduras no lo toque con su piel descubierta Tenga mucho cuidado cuando alg n tipo de calentador sea usado por o cerca de ni os o de personas inv lidas y cada vez que lo deje funcionando sin vigilancia 4 A ADVERTENCIA A Riesgo de electrocuci n No opere ning n calentador despu s de una aver a Desconecte la alimentaci n en el panel de servicio y pida a un t cnico electricista calificado que lo revise
15. GFCI circuit breaker to the wall can Remove a knockout from the wall can and attach the supply wire with a strain relief connector not included leaving a minimum of 6 inches wire lead Connect supply ground wire to grounding screw in wall can See Figure 3 Proceed to Part Two How do l install in an existing wall SAA Cut A Hole In The Wall REQUIRED MINIMUM distance of 6 inches from adjacent surfaces and 4 inches from the floor See Figure 4 However Cadet recommends 12 inches from adjacent surfaces and floor for longer and cleaner performance Heaters must be spaced at least 3 feet apart Cut a hole 8 inches wide by 10 inches high next to a wall stud SY Route Supply Wires Route supply wire from the GFCI circuit breaker to the wall can Remove a knockout from the wall can and attach the supply wire with a strain relief con nector not included leaving a minimum of 6 inches wire lead Connect supply ground wire to grounding screw in wall can See Figure 3 Figure 3 KNOCK OUT TWIST TO REMOVE STRAIN RELIEF CONNECTOR SCREW 132 Mount The Wall Can Insert wall can into opening keeping front of the wall can flush with the finished wall surface Secure the wall can to the stud with 2 screws not included through holes provided in the wall can As an option the rubber shim provided may be attached to the side of the wall can to square the wall can to the stud See Figures 1 and 2 Proceed to Part Two
16. INAL LIBRE PAA EN LA BARRA DE CORTOCIRCUITO DEL ELEMENTO c f T 4 o ne 3 TERMOSTATO c ELEMENTO CALENTADOR R PIDA AISLADA INTERRUPTOI R L MITE DE ALTA 10 TEMPERATURA DE Br REGLAJE MANUAL ee MOTOR IE DESCONEXI N RAPIDAAISLADA PUENTE CON CONECTOR TERMINAL LIBRE TERMOSTATO EN LA BARRA DE p DAAI aa y A CORTOCIRCUITO 3 6 DEL ELEMENTO Q a ae Pess 2 c 1 4 L2 INTERRUPTOR L MITE DE ALTA TEMPERATURA DE REGLAJE MANUAL D MOTOR L1 L2 SUMINISTRO DE ALIMENTACI N DE 240 208 CONSERVE ESTAS INSTRUCCIONES cadetheat com Tel 855 CADET US PO Box 1675 Vancouver WA 98668 1675 P gina 8 INSTRUCCIONES PARA LA INSTALACION 1 ADVERTENCIA Verifique que todos los cables de suministro el c trico sean del mismo voltaje que el calentador 2 Si va a reemplazar un calentador existente re vise la etiqueta del calentador antiguo 3 Todo trabajo y materiales el ctricos deben cumplir con el C digo El ctrico Nacional NEC por su sigla en ingl s con la Ley de Seguridad y Salud Ocupacional OSHA por su sigla en in l s y con todos los c digos estatales y locales Si se debe instalar un nuevo circuito o se necesita informaci n adicional sobre el cableado consulte a un electricista calificado 5 Use conductores de cobre solamente 6 A ADVERTENCIA A Riesgo de electrocuci n NO instale el cale
17. LICITA 8 EN CASO DE QUE CADET DECIDA REEMPLAZAR ALGUNA PIEZA DEL PRODUCTO CADET LOS REPUESTOS SE REGIRAN POR LAS MISMAS GARANTIAS DEL PRODUCTO LA INSTALACION O RE EMPLAZO DE LOS REPUESTOS NO MODIFICA NI PROLONGA LAS GARANTIAS VIGENTES EL REEMPLAZO O REPARACION DE TODO PRODUCTO O PIEZA CADET NO ORIGINA NINGUN TIPO DE NUEVA GARANTIA 9 Estas garantias le otorgan derechos legales espec ficos y es posible que usted tenga otros derechos que var en de un estado a otro Cadet no asume ni autoriza a nadie que lo haga en su nombre ninguna otra obligaci n o responsabilidad en relaci n con sus productos que no sean las que se establecen en este documento Si durante el per odo de garant a usted considera que su producto Cadet presenta defectos comun quese con Cadet Manufacturing Co llamando al 855 CADET US para obtener instrucciones sobre c mo tramitar la reparaci n o el reemplazo del producto Los reclamos de garant a pre sentados despu s de la finalizaci n del per odo no ser n acogidos Los productos que se devuelvan sin autorizaci n ser n rechazados Repuestos y Servicio En cadetheat com parts service encontrar informaci n sobre d nde obtener repuestos y servicio Reduzca Reutilice Recicle Este producto est hecho principalmente de materiales reci clables Puede reducir la cantidad de carbono que contribuye al medio ambiente reciclando este producto al t rmino de su vida til Comun quese con su centro loca
18. RMINAL TO ON ELEMENT 1 SHORTING BAR PE AAA SAVE THESE INSTRUCTIONS cadetheat com Tel 855 CADET US PO Box 1675 Vancouver WA 98668 1675 Page 2 INSTALLATION INSTRUCTIONS 1 WARNING Verify that the electrical supply wires are the same voltage as the heater 2 If replacing an existing heater check the label of the old heater 3 All electrical work and materials must comply with the National Electric Code NEC the Occu pational Safety and Health Act OSHA and all state and local codes 4 If you need to install a new circuit or need addi tional wiring information consult a qualified elec trician 5 Use copper conductors only 6 A WARNING A Risk of Electrical Shock DO NOT install the heat er directly above bathtub or sink DO NOT install in shower stall area Manufacturer recommends a minimum 2 foot clearance 7 Heater must be installed in a wall can Model CB Wall Can CC Part One 8 A WARNING Risk of Fire DO NOT install the heater in a floor in the ceiling below a towel bar behind a door or anywhere the air discharge may be blocked in any manner 9 AWARNING Fire or Explosion May Occur A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable va pors or liquids are used or stored 10 A WARNING A Risk of Electrical Shock Connect grounding lead to grounding screw provided Keep all foreign ob jects ou
19. ed to open the heater circuit and stop the electrical current flow when excessive operating temperatures are detected The problem must be assessed and the limit must be reset to resume operation Resetting the Manual Reset Limit Control Resetting the Manual Reset Temperature Limit Control If the manual reset limit control has opened the heater circuit due to excessive operating temperatures the heater will not work until the manual reset limit button is pressed After allowing the unit to cool for at least 10 minutes and resolving the problem causing the limit to trip typically the heater is blocked or needs cleaning see Maintenance Instructions use a narrow object such as a ball point pen to access the manual reset button through the upper left center section of the heater grill Press FIRMLY and be sure to listen and feel for a click indicating it has been reset Manual 3 Reset Limit A Button o e0 0 O Warrant For more effective and safer operation and to prolong the life of the heater read the Owner s Guide and follow the maintenance instructions Failure to properly maintain the heater will void any warranty and may cause the heater to function improperly War ranties are non transferable and apply to original consumer only Warranty terms are set out below LIMITED THREE YEAR WARRANTY Cadet will repair or re place any Com Pak Bath CB heater found to be defective withi
20. esentante de servicio autorizado C mo hacer funcionar el calentador Con el termostato incorporado la derecha del reloj G rela en sentido de las manecillas del reloj para aumentarla incorporado Con el temporizador incorporado control del calentador volver al ajuste anterior del termostato 1 Una vez que se haya realizado la instalaci n y reestablecido la energ a el ctrica gire totalmente la perilla del termostato en el sentido de las manecillas del reloj El termostato est a 2 Cuando la habitaci n haya alcanzado un nivel c modo gire la perilla del termostato en sentido contrario a las manecillas del reloj hasta que el calentador se apague El calentador se encender y apagar autom ticamente seg n esta temperatura preestablecida 3 Para reducir la temperatura del ambiente gire la perilla en sentido contrario a las manecillas Nota Si la perilla del termostato se gira completamente en el sentido contrario a las manecillas del reloj quedar en la posici n de sin calor pero a n se puede supeditar por el temporizador 4 Para operar el calentador con el temporizador encienda este ltimo la cantidad de los minutos que desee El temporizador est a la izquierda y se representa por el s mbolo Los n meros indican minutos El calentador permanecer encendido hasta que acabe el per odo el Acerca del control de limite de temperatura de reglaje manual El calentador est protegido por un con
21. ga la rejilla 4 Lave la rejilla con agua caliente y jab n y s quela 5 Mientras sujeta el ventilador para evitar que se da e o tuer za utilice una secadora o una aspiradora en el ciclo de soplado para quitar la suciedad en el elemento superior sin tocarlo 6 Aspire el rea del ventilador sin tocar los elementos 7 No lubrique el motor 8 Vuelva a instalar la rejilla y fijela con los tornillos Vuelva a colocar las perillas del termostato y el temporizador 9 Coloque el termostato en la graduaci n deseada 10 Vuelva a conectar la alimentaci n en el panel de desconex i n principal Tabla de resoluci n de problemas CONSULTE LOS C DIGOS EL CTRICOS LOCALES PARA DETERMINAR QU TRABAJOS DEBEN SER REALIZADOS POR PERSONAL DE SERVICIO ELECTRICO CALIFICADO intoma El interruptor se disyunta inmediata mente al encend erse el calentador Problema 1 Voltaje de suministro incorrecto 2 Circuito sobrecargado 3 Hay un cortocircuito en los cables de suministro o del calentador 4 Cortacircuito defectuoso olucion 1 Compruebe que el voltaje de suministro coincida con la calificaci n del calentador 2 El amperaje total de todos los calentadores en un circuito de rama no debe sobrepasar el 80 de la calificaci n de amperaje del cortacircuito y de las calificaciones de los cables de suminis tro Utilice un calentador de vatiaje inferior o reduzca la cantidad de calentadores en el circuito 3
22. ilidad gracias a la funci n de apagado autom tico por alta temperatura Su calentador Com Pak Bath ha sido completa mente probado y cuenta con una garant a limitada de 3 a os e Dos modelos para diversos tama os de habita ciones y aplicaciones con m ltiples voltajes El Calentador Com Pak Bath Gu a Para el Propietario Modelo Com Pak Bath de Voltaje M ltiple z Modelo con viele Termostato 1 y Vatios Amps Temporizador 120 1000 8 3 A CB103T 240 2 1000 4 2 Modelo Com Pak Bath de Multi Vatiaje eel Termostato y Vatios Amps Temporizador 500 2 1 240 2 CB132T 800 3 3 1300 5 4 Costado Y Rejilla Frente C mara de pared costado 10 1 3cm 25 4cm C mara de pared inferior 1 14 ascm 32cm 1 Termostato incorporado es de polo nico con una posici n sin calor cuando se gira completamente en sentido contrario a las manecillas del reloj El temporizador incorporado de 60 minutos supedita el termostato para brindar calor instantaneo 2 Los modelos de 240 voltios pueden usarse a 208 voltios El vatiaje es igual al 75 de la potencia nominal de 240 v Com Pak Bath con Termostato Incorporado y Temporizador Incorporado No Requieren Termostato Mural Bot n de L mite A Reglaje Manual Etiqueta Calificaci n Temporizador Incorporado Termostato Incorporado LISTE
23. l de reciclaje para obtener mayores instrucciones al respecto P gina 11 MANTENIMIENTO DEL CALENTADOR Mantenimiento Seg n sea necesario o cada seis meses como m nimo APAGADO ADVERTENCIA Desconecte la electricidad en el panel de desconexi n principal caja de cortacircuitos o fusibles y trabe o coloque un cartel en la puerta del panel de desconexi n principal para evitar que alguien vuelva a conectar la energ a mientras se est trabajando en el calentador De lo contrario podr an producirse graves golpes el ctricos quemaduras e incluso la muerte ADVERTENCIA Toda otra labor no detallada en esta Gu a para el propietario la debe efectuar un representante de servicio autorizado ntes de proceder es importante que usted verifique que se haya desconectado la alimentaci n y que el calentador no reciba energ a Los cortacircuitos no suelen estar correctamente mar cados y apagar el incorrecto podr a significar que sigue fluyendo electricidad al calentador aun cuando ste parezca no estar funcionando Si no se siente c modo al trabajar con artefactos el ctricos no est en condiciones de acatar estas pautas o no cuenta con los equipos necesarios solicite los servicios de un t cnico electricista calificado 2 Una vez que verifique que se ha apagado la alimentaci n correctamente prosiga con el paso siguiente 3 Retire las perillas del termostato y el temporizador los tornillos y extrai
24. minal A Then connect the loose red wire to terminal D Correct 240 Volt Configuration Correct 120 Volt Configuration White Wire gt White Wire gt CS Black Wire gt Black Wire lt Red Wire lt Red Wire Blue Wire Figure 6 Proceed to STEP 3 How do l insert the heater assembly into the wall can SUSE Install Heater Assembly CB132T Multi Watt How do configure the Multi Watt model CB132 SHa Multi Watt Element Wiring Configuration Heater must be connected to a GFCI protected branch circuit Use the table in Figure 5 to select the correct wattage required and the element terminals to be used y 240 208V WIRE CONFIGURATION 800 600 Disconnect and cut BLUE connector from terminal C Wrap loose wire end with electrical tape Move YELLOW connector at terminal B to the C terminal 500 375 Cut wire with BLUE connector at terminal C Wrap loose wire end with electrical tape Factory set at 1300 Watts DO NOT DISCONNECT THE YELLOW CONNECTOR FROM TERMINAL A Figure 5 i 2 E a Wi m D Ww a Proceed to STEP 3 O Figure 7 Multi Volt Figure 8 Multi Watt Model CB103 shown Model CB132 shown Turn heater assembly upside down element down with motor facing up Connect the supply wires to the heater wires with wire con necto
25. n hree years after the date of purchase These warranties do not apply 1 Damage occurs to the product through improper installation or incorrect supply vage 2 Damage occurs to the product through improper maintenance misuse abuse accident or alteration 3 The product is serviced by anyone other than Cadet 4 If ihe date of manufacture of the product cannot be deter mined E He product is damaged during shipping through no fault of adet 6 The use of unauthorized accessories or unauthorized compo nents constitutes an alteration and voids all warranties Refer to Cadet website or call customer service at 855 CADET US for list of authorized accessories and components 7 CADET S WARRANTY IS LIMITED TO REPAIR OR RE PLACEMENT AS SET OUT HEREIN CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE OR FOR CONSEQUENTIAL DAMAGES AND OR INCIDENTAL EX PENSES RESULTING FROM BREACH OF THESE WRITTEN WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY 8 IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR CADET PRODUCT THE REPLACEMENT PARTS ARE SUBJECT TO THE SAME WARRANTIES AS THE PROD UCT THE INSTALLATION OF REPLACEMENT PARTS DOES NOT MODIFY OR EXTEND THE UNDERLYING WARRANTIES REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES 9 These warranties give you specific legal rights and_you may also have other rights which vary from state to state Cadet nei ther assumes
26. nta dor directamente sobre la tina o lavamanos NO lo instale en la zona de la ducha el fabricante recomienda un espacio m nimo de 2 pies 7 El calentador debe instalarse en una c mara de pared Modelo CB C mara de Pared CC Parte Uno 8 MA ADVERTENCIA Riesgo de incendio NO instale el calentador en el piso en el cielo raso bajo la barra de la toalla detr s de una puerta ni en ning n otro lugar en el que la descarga de aire se pueda bloquear de alguna manera 9 ADVERTENCIA Podr an producirse explosiones o incendios Todo calentador contiene piezas que se calientan y pueden producir arcos voltaicos o chispas No o use en reas donde se utilice o almacene gas olina pintura o vapores o l quidos inflamables 10 A ADVERTENCIA A Riesgo de electrocuci n Conecte el conductor a tierra al tornillo de puesta a tierra suministrado Evite que entren objetos extra os al calentador 11 M ADVERTENCIA Riesgo de incendio Este calentador se calienta mucho cuando est en uso Precauci n Alta temperatura Riesgo de incendio Mantenga los cables el ctricos cortinas muebles em s materiales combustibles a por lo menos 3 pies por delante y a 6 pulgadas por encima y por ambos costados del calentador UBICACI N Instale verticalmente el calentador Com Pak Bath Modelo CB No se ha aprobado el uso horizontal del calentador ni tampoco su montaje en cielo raso CONTROLES Un termostato incorporado y temporizador de 60 min
27. orizador supedita el ajuste del termostato Si el calentador contin a funcionando fijelo en el ajuste m nimo Si el calentador contin a funcionando espere un poco para que el termostato tenga tiempo de responder al ajuste el termostato se debe reemplazar 1 Limpie el calentador consulte las instrucciones en la secci n MANTENIMIENTO DEL CALENTADOR 2 Desconecte la energ a en el cortacircuito Inspeccione todas las conexiones de alambres del suministro y del calentador para cerciorarse de que no haya nada suelto ni mal conectado Afiance o reconecte todas las conexiones sueltas No restablezca el cortacircuito sino hasta haber revisado y reparado todas las conexiones El elemento calien ta por un momento sin que gire el ventilador y luego deja de calentar inmediatamente 1 Motor o conexi n interna defectu osos 2 Ventilador o motor trabado 1 Debe reemplazarse el calentador o el motor del ventilador 2 Quite la obstrucci n y oprima el bot n de reglaje del calentador despu s de dejar que la uni dad se enfr e Pruebe el funcionamiento del calentador si el bot n de reglaje se ha oprimido aseg rese de escuchar y de sentir un chasquido indicando que se ha restablecido pero el calentador no funciona el calentador debe repararse o reemplazarse El calentador no funciona 1 El termostato est fijado muy bajo o bien en la posici n de sin calor 2 El calentador ha hecho saltar el interrupto
28. ower has been turned off and no power is going to the heater before proceeding Circuit breakers are often not marked correctly and turning the wrong breaker off could mean electricity is flowing to the heater even if the heater does not appear to be working If you are uncomfortable working with electrical appliances unable to follow these guidelines or do not have the necessary equipment consult a qualified electrician 2 Once you verify the power has been turned off correctly pro ceed to the next step 3 Remove thermostat and timer knobs screws and take off grill 4 Wash grill with hot soapy water and dry Breaker trips immediately upon energizing heater Heater fan operates but does not discharge warm air Heater will not shut off Heater discharges smoke or emits a burnt odor Element heats for a moment without the fan turning then immediately stops heating Heater does not run Heater continually trips the manual reset temperature limit control Page 6 5 While holding fan to avoid damage or bending use a hair dryer or vacuum on blow cycle to blow debris through the top element do not touch element 6 Vacuum fan area without touching the elements 7 Do not lubricate motor 8 Replace grill and secure with screws Replace thermostat and timer knobs 9 Turn thermostat to desired setting 10 Turn power back on at the main disconnect panel Troubleshooting Chart CONSULT LOCAL
29. r de reglaje de alta tempera tura 3 La energ a no est conectada en el cortacircuito 4 El o los cables que van al calenta dor est n rotos o mal conectados 5 Termostato y o temporizador defectuosos 1 Ajuste el termostato a una temperatura m s alta hasta que el calentador funcione vea el Problema No 5 si la dificultad persiste 2 Oprima el bot n de reglaje manual vea las instrucciones en la secci n OPERACI N DEL CALENTADOR 3 Conecte el cortacircuito correcto en el panel de desconexi n principal 4 Desconecte la energ a en el cortacircuito Revise la continuidad del cable de suministro y la conexi n apropiada a los cables del calentador 5 Repare o reemplace el calentador Se debe revisar la continuidad de todo el calentador o bien de sus componentes a fin de determinar la causa de cualquier problema El calentador disyunta continu amente el control limitador de tem peratura de reglaje manual 1 Se han acumulado polvo pelusas u otros materiales dentro del calentador 2 El flujo de aire est bloqueado 3 El ventilador o el motor est trabado 4 Ninguna de las anteriores 1 Limpie el calentador vea las instrucciones en la secci n MANTENIMIENTO DEL CALENTA DOR 2 Retire la obstrucci n Mantenga una distancia m nima de 6 pulgadas de las superficies adyacentes 4 pulgadas del piso y 3 pies de los muebles u otros objetos situados directamente delante del calen
30. r panel before removing grill 7 Use a hair dryer or vacuum on blow cycle to blow debris through the top element do not touch element 8 Install the grill before turning on power A WARNING Any other service not detailed in this Owner s Guide should be performed by an authorized service representative How to operate your heater With the built in thermostat fully clockwise The thermostat is on the right temperature room temperature turn the knob clockwise tion but can still be overridden by the built in timer With the built in timer stat setting 1 Once installation is complete and power has been restored turn the thermostat knob 2 When the room reaches your comfort level turn the thermostat knob counterclock wise until the heater turns off The heater will automatically cycle around this preset 3 To reduce the room temperature turn the knob counterclockwise To increase the Note If thermostat knob is turned fully counterclockwise it will be in the no heat posi 4 To operate the heater with the timer turn timer to desired minutes The timer is on the left and represented by the symbol The numbers indicate minutes Heater will remain on until time expires then control of the heater will return to the previous thermo About the Manual Reset Temperature Limit Control The heater is protected by a tempera ture limiting control The manual reset temperature limit control is design
31. rs not included See Figures 7 and 8 Now rotate the heater so the element and the fan are facing up The element should be at the top Insert the bottom edge of the heater assembly into the half round slots in the bottom lip of the wall can See Figure 9 IMPORTANT Push wires into bottom of wall can during insertion Be sure that supply wires are not caught between motor and wall can Attach assembly at top with screw provided Note Warranty is void if any material is sprayed on the element or blower Use a paint mask to cover any exposed areas of the heater if walls are to be textured or painted SAS Install Grill Secure grill with the screws provided Slide thermostat knob onto right control shaft extending through the grill and the timer knob onto the left shaft Turn power on at the main disconnect panel Page 4 Figure 9 OPERATING INSTRUCTIONS ANWARNING Risk of Electrical Shock and Fire The heater must be properly installed before it is used 1 Do not operate without grill 2 Keep electrical cords drapery furnishings and other combustibles at least 3 feet away from the front of the heater and 6 inches away from the sides 3 Do not tamper with the over temperature limit control 4 If the heater over temperature limit trips more than once per day the heater must be replaced 5 Clean heater at least every six months 6 After allowing the heater to cool turn power off at circuit breake
32. s las reas expuestas del calentador si las paredes se pintar n o se les dar textura INACIO Instale la rejilla Fije la rejilla con los tornillos suministrados Deslice la perilla del termostato en el eje del control derecho extendi ndola por la rejilla y la perilla del tempo rizador en el eje izquierdo Conecte la alimentaci n en el panel de desconex i n principal P gina 10 REJILLA v ex _ L OREJETA Figura 9 OPERACION DEL CALENTADOR A ADVERTENCIA Riesgo de electrocuci n e incendio El calentador debe instalarse correctamente antes de usarlo 1 No lo opere sin la rejilla 2 Mantenga los cables el ctricos cortinas mue bles y dem s materiales combustibles a por lo menos 3 pies por delante y a 6 pulgadas de los costados del calentador 3 No manipule el control limitador de sobretem peratura 4 Si los limitadores de sobretemperatura se di syuntan m s de una vez al d a se debe reempla zar el calentador 5 Limpie el calentador por lo menos cada seis meses 6 Despu s de dejar que el calentador se enfr e desconecte la electricidad en el panel de cortacir cuitos antes de retirar la rejilla 7 Use una secadora o aspiradora en el ciclo de soplado para quitar la suciedad en el elemento superior sin tocarlo 8 Instale la rejilla antes de conectar la energ a A ADVERTENCIA Toda otra labor no detallada en esta Gu a para el propietario la debe efectuar un repr
33. t of heater 11 AWARNING Risk of Fire This heater is hot when in use Caution High Temperature Risk of Fire Keep electrical cords drapery furnishings and other combustibles at least 3 feet from the front of the heater and 6 inches above and on both sides PLACEMENT Install the Com Pak Bathroom Heater Model CB vertically Heater is not approved for horizontal or ceiling mount appli cations THERMOSTAT A built in thermostat and 60 minute timer Note Cannot be used with a wall thermostat How do install for new construction SIA Mount The Wall Can REQUIRED MINIMUM distance of 6 inches from adjacent surfaces and 4 inches from the floor See Figure 4 However Cadet recommends 12 inches from adjacent surfaces and floor for longer and cleaner performance Heaters must be spaced at least 3 feet apart Secure the wall can to the stud with 2 screws not included through holes provided in the wall can As an option the rubber shim provided may be attached to the side of the wall can to square the wall can to the stud See Figures 1 and 2 Figure 1 Figure 2 Face of wall a can must yor oF WALL CAN extend 7 EA inch or inch from face of stud RUBBER ToP view SH TOP OF WALL CAN to allow for SHEETROCK thickness of sheetrock Attach wall can to stud with screws not included through holes provided in wall can Sa Route Supply Wires Route supply wire from the
34. tador 3 Retire la obstrucci n y oprima el bot n de reglaje manual del calentador vea las instrucciones en la secci n OPERACI N DEL CALENTADOR 4 Reemplace el conjunto del calentador P gina 12 2015 Cadet Impreso en EEUU Rev 06 15 720050
35. trol limit ador de temperatura con reglaje manual el cual est dise ado para abrir el circuito del calentador y detener el flujo de corriente el ctrica cuando se detectan temperaturas de funcionamiento excesivas El problema debe evaluarse y el l mite debe restablecerse para que el calentador vuelva a funcionar C mo restablecer el control de l mite de reglaje manual C mo restablecer el control limitador de temperatura de reglaje manual Si el control limitador de reglaje manual ha abierto el circuito del calentador debido a temperatu ras de funcionamiento excesivas el calentador no funcionar sino hasta que se oprima el bot n de l mite de reglaje manual Despu s de dejar que la unidad se enfr e durante al menos 10 minutos y resolver el problema de que causa que se disyunte el interruptor de l mite generalmente el calentador est bloqueado o necesita limpieza utilice un objeto puntiagudo como un bol grafo para acceder al bot n de reg laje a trav s de la secci n central superior izquierda de la rejilla del calentador Oprima el bot n FIRMEMENTE y aseg rese de escuchar y sentir un chasquido indicando que se ha restablecido Reglaje Manual e e oo Garant a Para lograr una operaci n m s eficaz y segura y prolongar la vida til del calentador lea la Gu a del propietario y siga las instrucciones de manten imiento Si no le da el mantenimiento adecuado al calentador in
36. ueva el conector AMARILLO del terminal B al terminal C 500 375 Corte el alambre con el conector AZUL en el terminal C Cubra el extremo del alambre suelto con cinta para uso el ctrico Fijado de f brica en 1300 vatios NO DESENCHUFE EL CONECTOR AMARILLO DEL TERMINAL A VATIAJE QUE DESEA Figura 5 Contin e con el PASO 3 Figura 7 Multi Voltaje Modelo CB103 shown Figura 8 Vatiaje M ltiple Modelo CB132 shown C mo se coloca la unidad del calentador en la c mara de pared wales Instale la unidad del calentador Voltee la unidad del calentador dejando el elemento abajo con el motor hacia arriba Empalme los alambres de suministro con los del calentador mediante conectores de alambres no incluidos Consulte las Figuras 7 y 8 Ahora gire el calentador de modo que el elemento y el ventilador queden hacia arriba El elemento debe quedar arriba Inserte el borde inferior del conjunto del calentador en las ranuras semicirculares del reborde inferior en la c mara de pared Consulte la Figura 9 IMPORTANTE Presione los cables hasta el fondo de la c mara de pared durante la inserci n Cerci rese de que los cables de suministro no queden atrapados entre el motor y la c mara de pared Conecte el conjunto en la parte superior con el tornillo que se proporciona Nota La garant a pierde su validez si se roc a alg n producto en el elemento o en el soplador Cubra con cinta para pintura toda
37. utos Nota No se puede usar con un termostato mural C mo se instala el calentador en paredes de construcciones nuevas ASTON Montaje de la c mara de pared La distancia MINIMA REQUERIDA es de 6 pulgadas desde las superficies adyacentes y 4 pulgadas desde el piso Consulte la Figura 4 Sin embargo Cadet recomienda 12 pulgadas desde las superficies adyacentes y el piso para lograr un rendimiento m s prolongado y limpio Si Se instalan varios calentadores deje al menos tres pies entre ellos Fije la c mara de pared al puntal con 2 tornillos no incluidos mediante los orificios que vienen en la c mara Como alternativa se puede a adir la cu a de caucho suministrada al costado de la c mara para cuadrarla con el puntal Consulte las Figuras 1 y 2 Figura 1 Figura 2 La cara de VISTA SUPERIOR Gaurd y la camara de Lo pared debe MES sobresalir entre y de PA DELA CAMARA DE PARED PARTE SUPERIOR DE LA pulgada de la CAMARA DE PARED PA L MINA DE YESO cara del puntal r J Conecte la camara de a fin de dejar pared al puntal mediante espacio para la los tornillos no incluidos lamina de yeso NSO Instalaci n de los cables de suministro Dirija el cable de suministro desde el cortacircuito GFCI a la c mara de pared Quite un destapadero y fije el cable de suministro mediante un conector de alivio de tensi n no incluidos dejando 6 pulgadas de cable de conexi n
38. validar la garant a y puede hacer que el aparato funcione incorrectamente Las garant as no son transferibles y rigen s lo para el comprador original Los t rminos de la garant a se indican a continuaci n GARANT A LIMITADA DE TRES A OS Cadet reparar o reemplazar todo calentador Com Pak Bath CB que se determine est averiado en un plazo de tres a os a partir de la fecha de compra Estas garant as no son pertinentes para 1 Da os que sufra el producto por instalaci n o voltaje de suministro incorrectos 2 Da os que sufra el producto por mantenimiento incorrecto uso indebi do abuso accidente o alteraciones 3 Servicio que se le haya dado al producto por parte de personas o entidades ajenas a Cadet 4 Casos en que no se pueda determinar la fecha de fabricaci n del roducto Casos en que el producto resulte da ado durante el embarque por causas ajenas a Cadet 6 El uso de accesorios o componentes no autorizados constituye una alteraci n e invalida las garant as Consulte el sitio web de Cadet o bien llame al servicio al cliente al 855 CADET US para ver una lista de los accesorios y componentes autorizados 7 LAGARANTIA DE CADET SE LIMITAA LA REPARACION O RE EMPLAZO TAL COMO SE ESTABLECE EN ESTE DOCUMENTO CADET NO SE HARA RESPONSABLE POR DANOS ALA PROPIEDAD O DANOS CONSECUENTES COMO TAMPOCO POR GASTOS AC CIDENTALES DEBIDO AL INCUMPLIMIENTO DE ESTAS GARANTIAS ESCRITAS O DE CUALQUIER GARANTIA EXPRESA O IMP
Download Pdf Manuals
Related Search
Related Contents
ST-SD20 User`s Guide Time Series Analysis Tools User Manual 取扱説明書 Terra 800 User Manual Samsung RT30GKSW User Manual INMOS TN24 - Exploring multiple transputer arrays A114.001 - Bartscher Garmin GPSMAP 4000 User's Manual Table of Contents Copyright © All rights reserved.
Failed to retrieve file