Home

Honeywell CO60PM Use and Care Manual

image

Contents

1. 35 SPA GARANT A LIMITADA DE 1 A O Lea todas las instrucciones antes de intentar utilizar este produto Esta garant a limitada de un a o se aplica a la reparaci n o sustituci n del producto siempre que haya alg n defecto de material o de manipulaci n A La garant a no cubre ning n da o resultante de un uso comercial abusivo o irracional ni da os causados intencionadamente Los defectos resultantes del uso normal y la rotura no se considerar n defectos de fabricaci n a efectos de esta garant a JMA NORTH AMERICA LLC NO ES RESPONSABLE DE LOS DA OS SECUNDARIOS O DERIVADOS DE NINGUNA NATURALEZA CUALQUIER GARANT A T CITA DE COMERCIABILIDAD O DE PREPARACI N PARA UN USO CONCRETO DE ESTE PRODUCTO QUEDA LIMITADA A LA DURACI N DE ESTA GARANT A Algunas jurisdicciones no permiten la inclusi n o limitaci n de los da os accidentales o derivados del uso o sobre el periodo de duraci n de la garant a de forma que las limitaciones indicadas pueden no afectarle Esta garant a le otorga derechos legales espec ficos pero usted tambi n puede tener otros derechos que var en de una jurisdicci n a otra Esta garant a solamente se aplicar al comprador original del producto y comenzar en la fecha original de la compra B Dado el caso JMA NORTH AMERICA LLC reparar o sustituir este producto si se detecta alg n defecto de material o de manipulaci n C La garant a no cubre el da o causado por cualquier intento n
2. Conecte el conector de la manguera de jardin y abra el suministro de agua Verificar las conexiones de agua visualmente para asegurar que no exitan p rdidas qimi Manguera de conexi n 31 SPA IMPORTANTE 0 e El equipo se entrega con el medio de enfriamiento Honeycomb d e e La frecuencia de limpieza depende de las condiciones locales del aire y el agua Por ejemplo en reas donde el contenido de minerales del agua es alto se pueden acumular dep sitos en el medio de enfriamiento Honeycomb restringiendo el caudal de aire El vaciamiento y rellenado del tanque con agua fresca al menos una vez por semana ayudar a reducir los dep sitos minerales Si quedan dep sitos minerales en el medio de enfriamiento Honeycomb el mismo deber removerse y lavarse con agua fresca Se recomienda limpiar el medio de enfriamiento Honeycomb cada dos meses o menos dependiendo de sus necesidades e No haga funcionar la unidad en modo FRIO con agua rancia en el tanque Se recomienda vaciar el tanque y rellenarlo con agua fresca si el agua ha estado estancada en el tanque durante un periodo de tiempo prolongado e Para mejores resultados permita que el medio de enfriamiento Honeycomb se seque luego de cada uso apagando la funci n de enfriamiento durante 15 minutos antes de apagar la unidad PRECAUCI N e Antes de limpiar la unidad ap guela y desenchufe la ficha del tomacorriente e Para limpiar la parte externa use una tela h meda para quita
3. sensoriales mentales reducidas falta de experiencia y conocimiento amenos que sean supervisados o instruidos acerca de su usopor una persona responsable de su seguridad e Para mover la unidad coja de sus asas laterales y SIEMPRE SIN AGUA EN EL TANQUE SPA Water Ice compartment Sy FLOOR LEVEL 25 SPA e Use s lo en receptaculos GFCI protegidos Los cables el ctricos tienen que estar protegidos Si van a estar extendidos a lo largo del suelo aseg rese de que cada cent metro est en perfecto estado y protegido para evitar tropiezos e El cable y los conectores tiene que ser resistentes al agua Aseg rese de que las conexiones al refrigerador de aire nunca se humedezcan Su equipo es resistente al agua pero todo aquello que se le a ada tiene que serlo tambi n e Coloque su unidad en un lugar en el que no pueda tropezarse con ella y est estable Debe apoyarse en un soporte firme 26 0 YN O0O0 20N f UINA 5 N 42 Entrada De Agua Y Compartimiento De Carga De Hielo Asa Panel Izquierdo Palanca Para Deflectores Horizontales Tanque De Agua Ruedas Deflectores Horizontales Indicador De Nivel De Agua SPA Honeywent O 9 Panel De Control 10 Panel Derecho 11 Continuo De Agua Conexi n A La Red 12 Tap n De Vacio 13 Panel Trasero 14 Cable De Alimentaci n Y Enchuf
4. Plug 15 Rear Grill Removal Screws 16 Water Fill Door 17 Honeycomb Cooling Media ENG Control Panel NOTE Speed control may be marked as High Med Low in certain units O ENG Control Knobs Speed On Off Connect to the power supply and turn the Speed knob The fan will start Change the speed from 1 for Low to 2 for Medium to 3 High To switch OFF the unit turn the Speed know to 0 Cool To begin cooling the desired area turn the COOL switch ON The water pump will operate You can feel the cooler air after the Honeycomb media is completely wet Swing Turn the SWING switch ON The louvers will begin to move from right to left automatically Manually adjust the horizontal louvers to change vertical airflow Horizontal Louvers Manually adjust the horizontal louvers to change vertical airflow 10 SPEED OFF ON COOL OFF ON SWING N ENG CAUTION Unplug from power when refilling Filling With Water Water can be filled into the air cooler by Water Inlet Manually Water Ice can be put into the tank through the top opening There is a hole for water to flow into the tank Continuous water supply Auto Refill Connect a garden hose to the continuous water supply inlet Water Inlet Manually e To refill the water tank pull out the Water Fill Door located on the top of the unit 16 on Page 8 and fill water to the Water Fill Door Max as indicated on the Water Level
5. deposits remain on the Honeycomb media the media should be removed and washed under fresh water The media should be cleaned every two months or sooner depending on your needs e Do not run the unit in COOL mode with stale water in the tank Empty the tank and refill it with fresh water if the water has been standing in the tank for an extended period of time e For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off WARNING Before cleaning turn the unit off and disconnect from the power source e Use a damp cloth to remove dirt and dust from the outside of the unit e Never use abrasive cleaners e When the unit is not in use store it in a dry place out of direct sunlight 13 ENG Draning and Cleaning The Water Tank e Turn the power off and disconnect the air cooler from the power supply e Move the unit to a location where it can be drained e Remove the drain plug and allow the tank to empty 12 on Page 8 e Refill the water tank up to the maximum level with clean water and drain it completely e Fill water tank and rinse at least 2 3 times before use Water Drain e After cleaning ensure that the drain plug is back in place Plug er e Plug into the power supply and turn on unit O Cleaning The Honeycomb Cooling Media e Turn off the unit and unplug the power cord from wall outlet e Rotate the unit facing the back pane
6. operaci n mantenimiento y resoluci n de problemas de su acondicionador No seguir las instrucciones puede da arlo y o perjudicar su funcionamiento y anular la garant a SECCION PAGINA NS A A e 21 2 RECOMENDACIONES PARA EL USUARIO occccccccccccnnnnncncncnnccnnnnnnnonanannncnacnnnnnns 22 3 NORMAS DE SEGURIDAD 0ooccccccnnnnccncncnnoncncnonononononononanononononcnnnnnnonanancnnnnannnnnnns 24 4 DESCRIPCI N COMPONENTES ceccccececeecessescecessececescesceecrseceescessereatereateres 27 5 USO Y FUNCIONAMIENTO cccccc ccc cccccccccceeeeecceeeececeescueeeeceeeeeeeeeeeeeeueeeeeeueeaeess 28 Panel De Control occccnccccnnccnonoccnonocnonnnnnonncnnnononnnnnnnnnnnnnnononnnononnnonrnnconnenonnncnnnanes 28 Mandos De Control ooccccocccnconccnnoccnccncnnnonocnnononnnoncnnonnnononoronononnnonnnnonnnnnnnnarannnnos 29 Llenado Del Tanque cistitis a 30 6 LIMPIEZA Y MANTENIMIENTO c 00oooccccccnnccnccnnnnnocccnnonncnnnnnnoncnnnnonnnnnncnnnnnnoninnnnnnnns 32 7 GU A DE SOLUCI N DE PROBLEMAS cccccccocccccicinininnononononinonononenennninnnnncnranenonos 34 8 ESPECIFICACIONES T CNICAS ccsccssssssssessssscscscecsescscsesesesesesssesesasscacseseseaeass 35 9 ESQUEMA EL CTRICO cccccececcesessescssecceseccececcecescecceseceecuscecsecessecatsecateecatereass 35 10 SERVICIO Y GARANT A cccccccccccccnccncncnnnnnanannanonononnnnnnonnnnnnnnnn nana no nano nana nnnnnnanannns 36 20 SPA GRACIAS Felicitaciones por su compr
7. Indicator 8 on Page 8 re k e Do not fill water above the Max water level mark l e For maximum cooling performance put ice cubes inside the Ice Loading Compartment located on the top of the Air Cooler 1 on Page 8 o Water Inlet Ice Compartment 11 ENG Filling With Water Continuous Water Supply Connection CAUTION Unplug from power source before filling This automated process eliminates the need to manually refill the water tank Securely connect the continuous water supply connector located on the lower left side panel 11 on Page 8 to the water supply Turn on the water The water tank will refill automatically The water float valve will detect the water level and will automatically start or stop the water flow Plug the unit into the power supply and turn the unit on Installing Hose Adapter And Float Valve Connect the garden hose to the water supply connector 11 on Page 8 Verify that connections are secure and turn on the water co Hose Connectora 12 ENG Important Please Read O e The cooler is supplied with Honeycomb Cooling Media w e The cleaning frequency for the Honeycomb media depends on local air and water conditions In areas where the mineral content of water is high mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow Draining the water reservoir and refilling with fresh water at least once a week will help reduce mineral deposits If mineral
8. 5 USE amp OPERATION Su cai OEE EEEE Ea 9 Control Panel cccccccceccccceececcceeeeuceeececueeeeceeeeuuceeeeecueeceeeeeeueeeeeseuaeueeeeueeaeeeeesenans 9 Control Kn a R 10 Fill Water cda 11 6 CLEANING amp MAINTENANCE oonnnocccccccccccccnccnonononnnananancnnnanannnnn non nn nnnnnn RAAEN 13 7 TROUBLESHOOTING GUIDE cconnnnccccccncncncnnnnnnnnnnnnnnaccccncnn nano nonnnnnnnnnananananananans 15 8 TECHNICAL SPECIFICATIONS ooocccccccccccconnnnnnccnnnncnnnnnnnonononnnnnnccnanananananonononnnnns 16 9 ELECTRICAL WIRING DIAGRAM occcccccccccnnnnnnnnncncnonanonanonononnnnnonanananancncnnncnnnononos 17 10 SERVICE AND WARRANTY 0 0 cccccccccccccccccccseseeceeeeeuueeceeeeeeeeeeueeaueeeeseseeeeeeeeeeeess 18 ENG Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler For optimum cooling from your cooler fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler Cooler Location Important Please Read Place the cooler in front of an open door or window Ensure that there is adequate cross ventilation in the room by leaving a door or window open opposite the cooler Following these guideline will ensure your cooler will work as effectively as possible Not an Air Conditioner Important Please Read The evaporative air cooler is not an air conditioner as it does not use a compressor or refrig erant gas It should not be expected to cool as effic
9. Honeywell Portable Evaporative Air Cooler for Outdoor Indoor amp Commercial Use Enfriador de aire portatil por evaporacion Ideal para Uso Externo Interno y Comercial OWNER S MANUAL Read and save these instructions before use MANUAL DEL USUARIO Lea y guarde estas instrucciones antes de usar NAAA ANN NOOO NANA NANA ANN IO QEU Model CO60PM Modelo CO60PM A SIS Power rating 220 Watts Voltage rating 120 Volt AC 60Hz Potencia 220 Watt Voltage 120 Volt AC 60Hz For product inquiries or support visit www honeywellaircoolers com Para consultas sobre productos o soporte t cnico visite www honeywellaircoolers com Customer Support 1 800 474 2147 Made in P R C Centro de servicios al cliente 1 800 474 2147 Fabricado en China This page is intentionally left blank ENG Read all instructions carefully before setting up and operating the cooler and please keep this instruction manual for future reference This manual is designed to provide you with important information needed to setup operate maintain and troubleshoot your cooler Failure to follow these instructions may damage and or impair its operation and void the warranty SECTION PAGE 1 THANK YOU ocn nadan 2 2 USER TIPS 200 tii a cda 3 SN teeth ace tet rE 5 4 PARTS DESCRIPTION u ccccccccccccccccccccccceeseeueeeeecececceeeeeeueuuueeseseueeeesseseeeeeeeeeuenss 8
10. UCI N Cable el ctrico no esta Aseg rese que el cable el ctrico conectado este enchufado y el interruptor de alimentaci n en ON La unidad no esta encendida Intente prender la unidad apretando los botones en el panel de control o en el control remoto No enfr a La unidad hace ruido Bomba de agua no esta prendida Encienda la funci n COOL en el panel de control o en el control remoto Nivel de agua bajo o vacio en Rellenar el tanque de agua el tanque de agua cuando se selecciona funci n COOL Bomba de agua da ada o Contacte el centro de servicio dep sitos de calcio en el soplador Emisi n de olor Nueva unidad Cuando la unidad es utilizada por primera vez el panal Honeycomb emite un olor que ser disipado en una semana despu s del uso inicial Unidad usada Puede haber dep sitos de algas en el panel Honeycomb Cambiar el panel Contacte el centro de servicio SERVICIO AL CLIENTE 1 800 474 2147 34 MODELO N Tensi n Frecuencia Potencia Corriente Capacidad del tanque de agua Medio de enfriamiento Dimensiones del producto Inches Peso neto Diagrama De Cableado El ctrico switch switch SPA CO60PM 120 V 60 Hz 220 Watts 1 83A 15 8 Galones Honeycomb 27 56 L X 18 35 W X 40 0 H 41 5 lbs swing motor capacitor switch plug r P
11. a de este vers til Enfriador de aire por evaporaci n Honeywell Para un ptimo desempe o de su unidad primero ll nela con agua Si dispone de hielo eso aumentar su potencia de enfriamiento Por favor lea estas instrucciones cuidadosamente IMPORTANTE COLOCACI N DE ENFRIADOR cuando se utiliza en el interior Situe el enfriador en frente de una ventana o puerta abierta Asegures que hay una adecuada ventilaci n en la estancia dejando una puerta o ventana abierta en el otro lado del enfriador Si sigue estas instrucciones se asegurar que su enfriador trabajar de forma efectiva 21 SPA FR O EFICIENTE NATURAL El enfriamiento de aire por evaporaci n es la manera m s natural de enfriamiento similar a una brisa que recorre un lago Esta disminuci n de la temperatura de esta brisa produce un efecto refrescante y relajante en la personas El enfriador de aire evaporativo refresca el aire por medio de la evaporaci n del agua Cuando el agua se evapora del aire se obtiene como resultado una mezcla de mol culas de aire y agua Este intercambio qu mico requiere calor que es tomado de las mol culas del agua resultando un enfriamiento de la temperatura del aire que sale del aparato Honeycomb Cooling Media AY Ns ew A Pi 27 gt a ae YS SH Cold and Warm and humid air dry air A s H ST Al H S tear Y Eva
12. e 15 Los Tornillos De La Rejilla Posterior 16 La Puerta De Llenado De Agua 17 Medio De Enfriamiento Honeycomb 27 SPA PANEL DE CONTROL NOTA El control de velocidad puede ser High Med Low Alta Media Baja en ciertas unidades 28 MANDOS DE CONTROL VELOCIDAD ENCENDIDO SPEED ON OFF Conecte a la red de alimentaci n y gire el mando de velocidad SPEED Comenzar a funcionar el ventilador Cambie la velocidad de 1 Baja a 2 Media a 3 Alta Para apagar la unidad gire el mando de Velocidad hasta 0 ENFRIAMIENTO COOL Para comenzar a enfriar el rea deseada gire el bot n COOL a ON La bomba de agua funcionar y comenzar a sentir el aire fresco despu s de que el filtro Honeycomb este mojado completamente OSCILACI N SWING Gire el bot n SWING a ON Las rejillas comenzar a moverse de derecha a izquierda de forma autom tica Ajuste manualmente los deflectores horizontales para cambiar el flujo de aire vertical DEFLECTORES HORIZONTALES Ajuste manualmente los deflectores horizontales para cambiar el flujo de aire vertical SPEED OFF ON COOL OFF ON SWING N SPA 29 SPA PRECAUCI N Desconecte la unidad de la toma corriente cuando a ada l quido LLENADO DEL TANQUE El equipo puede ser llenado de agua por Entrada de agua manualmente Agua hielo se puede colocar en el tanque a trav s de la abertura superior Hay un agujero para que el agua fl
13. iently as a refrigerated air conditioner ENG Energy Efficient No Compressor Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low Warm air is drawn into the cooler and enters the Honeycomb Cooling Media Water pumped from the tank pours over the honeycomb media As the warm air passes through the media the water absorbs the heat naturally cooling and humidifying the air A fan propels the cooled air out into the room This no compressor system cools naturally efficiently and inexpensively Honeycomb Cooling Media 2 x gt ge 2 A by aA Tate sh GDA laf YYYYYYY Cool and humid air ON LILILIII Y UT Evaporative Air Cooling Mechanism ENG Indoor Use The recommended maximum relative humidity level is 60 or less which allows a noticeable temperature decrease The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low 4 ad The evaporative air cooler should not be used in enclosed rf Pi spaces It must be kept level and there must be water in the water tank The room should have doors and windows Room with open windows amp door opened to allow free air flow The evaporative air cooler works RECOMMENDED best when placed near an open window so that outside air is an drawn into the evaporative air cooler the air circulates in the room then exits
14. l and locate the Rear Grill Removal Screws 12 on Page 8 Remove the 4 screws with a screw driver e Pull the rear grill panel until it is completely removed e This cooler has Honeycomb cooling media on the right and left panels The cleaning and removal procedure is the same as rear panel e The Honeycomb cooling media can now be seen Clean honeycomb with clean cloth to remove all the dust amp dirt particles e Once cleaning is finished reassemble the unit e Plug into the power supply and turn on unit Open Screws The air cooler is now ready to be used This cleaning process should be repeated monthly to maintain the integrity of the unit and to remove particles filtered from the air 14 PROBLEM No discharge of air POSSIBLE CAUSE Cord is not plugged in ENG SOLUTION Make sure power cord is plugged in and the supply switch is on Power is not on Turn the unit ON by pressing button on the control panel Not Cooling Unit is making noise Pump is not turned ON On Control Panel turn COOL FUNCTION to ON Low or no water in tank when COOL is selected Refill water tank Damaged Pump or Calcium deposits on blower Contact service center Odors When the Cooler is new When the unit is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate within a few hours of initial use If the Cooler has been used Custome
15. nchufe da ado Desechar el ventilador o acercase a un centro de servicio autorizado para su revisi n y o reparaci n ADVERTENCIA Para reducir el riesgo de incendios o descargas el ctricas no usar el ventilador con cualquier s lido dispositivo de control de velocidad 24 e NO intente reparar ni ajustar ninguna parte el ctrica mec nica del enfriador ya que esto puede anular la garant a e NO obstruya la entrada salida de aire del aparato ya quepuede causar da os al motor e NO inserte ni permita que entren objetos a trav s de ningunaabertura de ventilaci n salida ya que esto puede da ar alproducto y podr a causar descargas el ctricas 6 incendios e NO ponga en funcionamiento el aparato sin el medio Honeycomb ya que esto sobrecargar y da ar al motor e NO deje el aparato funcionando sin atenci n por un periodolargo de tiempo e NO deje que los ni os jueguen con este aparato ni con suembalaje ni con las bolsas de pl sticos Si la unidad se da a o funciona mal desconectala Consulte la secci n de Soluci n de problemas P 34 y o por favor busque consejo profesional Coloque la unidad sobre un piso nivelado Este producto no se destina para uso en lugares mojados oextremadamente h medos No lo use en ba os ni en que no esten cubiertos Cuando no se utilice siempre gu rdelo en un lugar seco e Este aparato no se destina a ser usado por personas incluyendo ni os con capacidades f sicas
16. nd pulling on the power cord plug end only never pull the cord DO NOT use the product in areas where gasoline paint or other flammable goods and objects are stored When using the COOL setting check the water tank to Water Level Indicator ensure that it is full Operation of this cooler on the COOL setting with an empty tank may result in damage to the water pump Warning To reduce the risk of fire or electric shock do not use this appliance with any solid state speed control device e SS SISI z SII SISI SSS ax SS NSS SAS ENG e DO NOT attempt to repair or adjust any electrical or mechan ical functions of the cooler as this may void the warranty DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire DO NOT operate with the Honeycomb media removed as this Water Ice Compartment will overload and damage the motor DO NOT leave the operating appliance unattended for any extended period of time DO NOT let children play with this appliance packaging or plastic bags If the unit is damaged or if it malfunctions do not continue to use it Refer to the Troubleshooting Guide page 15 and contact the service center Place the unit on a level floor This product is not intended for use in wet or damp locati
17. o autorizado de reparar el producto ni el derivado de no utilizarlo de acuerdo con el manual de instrucciones 36 SPA D Por favor lea el manual de instrucciones detenidamente antes de configurar o de utilizar este producto Si considera que este producto sufre un defecto de fabricaci n o si tiene dudas sobre el mismo por favor contacte con nuestro Servicio de Atenci n al Cliente CUSTOMER SUPPORT JMA North America LLC Ramsey New Jersey 07446 Phone 800 474 2147 Email info jmana us Cuando contacte con nuestro Servicio de Atenci n al Cliente por favor tenga la siguiente informaci n preparada como prueba de compra Todas las solicitudes de cobertura de la garant a tendr n que ir acompa adas de una prueba de compra que ser una copia de la factura original Model ee O AA Fecha de COMPS SONORO OPPPA_ A PU 0 O0 E anaki Kaa A eiaa a niaaa aa Eiraan EE Punto deventa S aerieni aaie e E e E Ea a a E EE 37 Distributor JMA North America Ramsey New Jersey 07446 Customer Support 1 800 474 2147 E mail info Ojmana us www honeywellaircoolers com CO60PM_IM_Eng_Spa_USA lowes _8 December 2012 2012 AirTek International Corporation Limited The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representation or warranties with respect to this product Manufactured by AirTek International Corporation Limited Honeywell
18. ons DO NOT use in bathrooms Never locate the product where it may fall into a bathtub or other water container Store in a dry area when not in use This appliance is not intended for use by persons including children or elderly with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety e Always grip the side handles to move the cooler Floor Level ENG e Use Only on GFCI Protected Receptacles e Power cords have to be contained If they must run along the ground make sure every inch of them is secured so they will not be tripped over e The wiring and connections must be waterproof Be sure the connections to the air cooler never get wet Your unit is waterproof but everything attached to it must be waterproof too e Set up your unit so it cannot be tripped over or wobble loose It must rest on a solid support ENG 06 pu if TMT fs h ONoaRWND Water Inlet and Ice Loading Compartment Handle Left Honeycomb Panel Lever for Horizontal Louvers Water Tank Casters Horizontal Louvers Water Level Indicator 9 Control Panel 10 Right Honeycomb Panel 11 Continuous Water Supply Connection 12 Drain Plug 13 Backside Honeycomb Panel 14 Power Cord amp
19. porative Air Cooling Mechanism 22 El nivel m ximo recomendado de humedad relativa es del 60 El descenso de la temperatura del ambiente ser mayor en climas secos Se produce una mayor evaporaci n cuando la humedad es baja El enfriador de aire por evaporaci n no deber a serutilizado en espacios cerrados Debe mantenerse niveladoy debe haber agua en el tanque La habitaci n debe tener puertas y venta nas abiertas para permitir un libreflujo de aire El enfriador de aire por evaporaci n trabajamejor cuando se coloca cerca de una ventana abierta deforma que el aire exterior sea tomado por el acondicionadorde aire por evaporaci n el aire circula en el ambiente y sale a trav s de la puerta El m ximo efecto de enfriamientose siente cuando una persona est en el flujo deaire proveniente del enfriador de aire por evaporaci n El enfriador de aire por evaporaci n tambi n se puedeutilizar para humidificar el aire seco durante los meses declima fresco Para utilizarlo como humidificador las ventanasy puertas deber n permanecer cerradas El enfriador deaire por evapo raci n no es un aire acondicionado yaque no usa compresor ni gas refrigerante NOTA Cuando el producto se utiliza por primera vez tendr un olor que se disipar en aproximadamente una semana SPA Ambiente con puertas y ventanas abiertas Ambiente con puertas y ventanas cerradas 0 23 SPA LEA Y GUARDE ESTAS INSTRUCCIONES Cuando se u
20. r Support 1 800 474 2147 There may be an algae issue Replace the Honeycomb Cooling Media 15 ENG TECHNICAL SPECIFICATIONS MODEL NO CO60PM Voltage 120 V Frequency 60 Hz Wattage 220 Watts Ampere 1 83A Water Tank Capacity 15 8 Gallon Cooling Media Honeycomb Product Dimension inches 27 56 L X 18 35 W X 40 0 H Net Weight 41 5 lbs 16 ELECTRICAL WIRING DIAGRAM ENG 1 2 switch switch switch swing motor capacitor N plug a L 17 ENG 1 YEAR LIMITED WARRANTY Read all the instructions before attempting to use this product This 1 year limited warranty applies to repair or replacement product found to be defective in material or workmanship A This warranty does not apply to any damage resulting from commercial abusive unreasonable use or supplemental damage Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty JMA NORTH AMERICA LLC IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an applied warranty lasts so the above limitations or exclusions may not apply
21. r la suciedad y el polvo e Nunca utilizar limpiadores abrasivos e Cuando no utilice el producto gu rdelo en un lugar seco y alejado de la luz solar directa 32 SPA LIMPIEZA Y VACIAMIENTO DEL TANQUE DE AGUA Apagar el equipo y desconectar de la toma corriente Desplace la unidad a una ubicaci n donde pueda vaciarse y quite el tap n del tubo de drenaje vea el n mero 12 en la descripci n de partes en la p gina 27 Una vez que el tanque est vac o rell nelo con agua limpia y vuelva a vaciarlo Esto deber a repetirse semanalmente para mantener la integridad de la unidad y eliminar las part culas filtradas del aire Si el enfriador de aire no es usado por un per odo largo de l 7 Tap n de drenaje tiempo el tanque de agua debe limpiarse al menos dos veces de agua antes de usarse nuevamente LIMPIEZA EL MEDIO DE ENFRIAMIENTO HONEYCOMB Apagar el equipo y desconectar de la toma corriente Quite los tornillos de la rejilla posterior 15 p 27 situados en el panel posterior Tire hacia arriba del panel de rejilla trasera para quitarla El medio Honeycomb est ahora expuesto y se puede limpiar con un pa o para quitar todo el polvo y las part culas de suciedad Una vez que la limpieza se ha terminado ensamblar la unidad nuevamente como se describe arriba Conectar a la toma corriente y encender el equipo Tornillos abiertos 33 SPA PROBLEMA No hay salida de aire POSIBLE CAUSA SOL
22. tilicen aparatos el ctricos siempre deber an tomarse precauciones de seguridad b sicas Su enfriador trabaja a una tensi n de 120 V AC 60 Hz Revise la tensi n de su hogar para asegurarse de que coincide con la especificaci n nominal del aparato Antes de poner en marcha el aparato quite todo el embalaje y compruebe que el enfriador est en buenas condiciones NO ponga en funcionamiento ning n producto con cables oclavijas de conexi n da adas Recomendamos no utilizar prolongadores el ctricos con este aparato No ubique el cable de alimentaci n debajo de alfombras Ubique el cable de alimentaci n lejos de lugares en los que se pueda pisar Siempre desenchufe el producto antes de rellenar el tanquede agua Siempre desenchufe el aparato de la alimentaci n antes delimpiarlo repararlo reubicarlo Desenchufe el cable de alimentaci n tirando desde el extremo de la clavija de alimentaci n nunca tire del cable No use el producto en reas donde se almacene gasolina pinturas u otras sustancias y objetos inflamables Cuando se usa la opci n de Enfriamiento COOL por fs 120 Volt AC 60Hz S SHOCK HAZARD Wo EN WATER LEVEL INDICATOR favorrevise el tanque de agua para asegurarse de que est lleno El funcionamiento de esta unidad en la opci n de Enfriamiento con el tanque vac o puede da ar la bomba de agua Use s lo en receptaculos GFCI protegidos No operar ning n ventilador con un cable o e
23. to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This warranty applies only to the original purchaser of this product from the original date of purchase B At its option JMA NORTH AMERICA LLC will repair or replace this product if it is found to be detective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual 18 ENG D Please read the Instruction Manual carefully before setting up or using this product If you believe this product to be suffering from a manufacturing fault or if you have inquiries about this product please contact our Customer Support CUSTOMER SUPPORT JMA North America LLC Ramsey New Jersey 07446 Phone 800 474 2147 Email info jmana us When contacting our Customer Support please have the information below along with the proof of purchase All warranty requests must be accompanied by a proof of purchase which is a copy of the original receipt Model AATE EEEE TEE N ATE E A EAE E AEE AOA E AT DA A NN PUECOASCO MIMO a Aa AE 19 SPA Lea cuidadosamente todas las instrucciones antes de configurar y operar la unidad y por favor guarde este manual de instrucciones para futuras consultas Este manual est dise ado para proporcionarle informaci n importante necesaria para la configuraci n
24. uya hacia el tanque Suministro de agua continua Auto Refill Conectar una manguera de jard n a la entrada de suministro de agua continuo Entrada de agua manualmente e Para rellenar el tanque de agua tire de la puerta de llenado de fake P agua situado en la parte superior de la unidad 16 en la L m pae RES p gina 27 y llenar de agua al m ximo como se indica en el i Y 4 indicador de nivel de agua 8 en la p gina 27 e No llenar el tanque por arriba del nivel m ximo que se marca e Para obtener un rendimiento m ximo de enfriamiento poner cubitos de hielo en el interior del compartimiento de carga de hielo ubicado en la parte superior del refrigerante del aire Entrada de agua Compartimiento de hielo 30 SPA LLENADO DE AGUA CONEXI N CONTINUA SUMINISTRO DE AGUA PRECAUCI N Desconecte la unidad de la toma corriente antes de a adir agua Este proceso automatizado elimina la necesidad de rellenar manualmente el dep sito de agua Conecte firmemente el conector de suministro de agua continuo situado en el panel lateral inferior izquierda 11 en la p gina 27 para el suministro de agua Abrir el suministro de agua El tanque de agua se llenar automaticamente La v lvula de flotador de agua detecta el nivel de agua y autom ticamente inicia o detiene el flujo de agua Conecte la unidad a la fuente de alimentaci n y encender la unidad INSTALACI N DEL ADAPTADOR DE MANGUERA Y DE LA V LVULA DE FLOT
25. via the door The maximum cooling effect is felt when a person is in the flow of air coming out of the evaporative air cooler The evaporative air cooler can also be used to humidify dry air during cool weather To be used for humidification the windows and doors should be closed to allow the humidified Room with closed windows amp door air to accumulate NOT RECOMMENDED NOTE Important Please Read When the product is used for the first time the Honeycomb Cooling Media will have an odor O which will dissipate in a few hours or so of initial use ENG Read And Save These Instructions When using electrical appliances basic safety precautions should always be followed Your cooler runs on 120 Volt AC 60 Hz current Check the fs 120V 60 Hz X household voltage to ensure it matches the appliance s rate specification Before operating the product remove it from its packaging and check that it is in good condition Shock Hazard DO NOT operate any product with a damaged cord or plug VV We recommend not using an extension cord with this appli e all ance ZN DO NOT run power cord under carpeting or cover it with rugs or runners Keep the cord away from areas where it may be tripped over Always unplug the product before refilling the water tank Always unplug the appliance from the power source before cleaning servicing or relocating the unit Remove the power cord from the electrical receptacle by grasping a