Home
Champion Cooler MCP44 Installation Guide
Contents
1. ee OVERFLOW LINE overflow fitting E eee Pull line through and reinstall nipple into overflow line LINE THROUGH OVERFLOW JUNCTION FITTING NIPPLE PUMP STRAINER NETTING NOT SHOWN FOR CLARITY PURGE HOSE OVERFLOW OVERFLOW FITTING D RAIN FITTING gt 4 Install the overflow drain into the hole in the bottom of the cooler See illustration above NOTE While tightening drain assembly be careful not to twist rubber washer as this will cause leaks DO NOT OVERTIGHTEN NOTE The float may need to be slightly adjusted after shipment It should be set to maintain a 2 level of water in the reservoir NOTE A standard water hose can be connected to the overflow drain or the sillcock for water discharge if a purge pump is installed OPERATING DIRECTIONS 1 With water turned on correct ventilation in place and unit plugged in turn on the cooler by pressing the Power On Off button either on the control panel or remote control HI MED LO ON OFF NOTES The default start up setting for the unit is Fan on HIGH and Pump ON Subsequently the unit will start in the last operating settings including after a power failure For best results turn pump on a few minutes before the fan allowing media to already be wet 2 Pressing the Fan button on either the control panel or remote cycles High Medium and Low 3 Pressing the Pump button on either the control panel or remote turns
2. clima Brocas para realizar agujeros gu a Tuber a de cobre o pl stico de 1 4 Llave ajustable V lvula de grifo de manguera Nivel de burbuja SI TIENE PREGUNTAS O HAY PARTES FALTANTES LLAME AL 1 800 643 8341 ANTES DE DEVOLVER A LA TIENDA Destornillador Phillips SELECCI N DE LA VENTANA Verifique que haya una distancia libre de 22 de ancho y alto en la ventana seleccionada Aseg rese de que la estructura de la ventana antepecho y marco sea lo suficientemente resistente para soportar el peso operativo de la unidad 93 1b y de que aceptar las piezas de montaje PROCEDIMIENTOS DE INSTALACI N 1 Abra la caja retire la unidad extraiga y verifique que incluya todas las piezas ABRA LA UNIDAD 3 SEPARE LA SECCI N DE LA UNIDAD SUJETE LA CARCASA DEL VENTILADOR EXTIENDA LA CARCASA Y SUJETELA AL FRENTE DEL CUERPO DEL ENFRIADOR CON 12 TORNILLOS EGE 1 RETIRELOS 4 TORNILLOS AG DELASECCI N DE ESPALDA 2 EMPUJAR HACIA ARRIBA EN i LA SECCI N DE ESPALDA 2 Sostenga la unidad en posici n vertical Retire los cuatro tornillos 2 en la parte superior y 2 en la inferior que fijan la protecci n posterior del medio y separe las secciones anterior y posterior Tire de la carcasa del ventilador hacia afuera lo m s posible hasta que est totalmente encajada en la contrapieza Asegure en la posici n con 12 tornillos incluidos Desde el exterior
3. coloque la secci n anterior del enfriador en su posici n y cierre la ventana para ayudar a mantenerlo en su lugar mientras se instalan los soportes de montaje 4 MINIMUM ALF IZAR DE LA VENTANA DE MONTAJE OPCIONAL UY Sl A TORNILLOS SOPORTE DE MONTAJE DE ANTEPECHO DE VENTANA ANTEPECHO DE VENTANA mi TORNILLOS 4 Coloque un nivel de burbuja en la a unidad para asegurarse de que el A i enfriador est nivelado antes de ENRASADO INSTALACION la instalaci n A ESCUADRA Instale los soportes de montaje como se muestra en la instalaci n a continuaci n Despu s de instalar el enfriador fije los paneles de cierre de acorde n utilizando la superficie adhesiva o puede asegurarlos con tornillos pero cerci rese de que los tornillos no interfieran con las aspas del ventilador Utilice masilla para todo tipo de clima para sellar cualquier hueco que haya quedado alrededor de la unidad Conecte a la fuente de agua como se muestra en la siguiente panel entonces cerrar la unidad con cuatro tornillos ON UL N 1 CONECTAR LA MANAGUERA DE SUMINISTRO DE AGUA 2 COLOQUE DE NUEVO EN LA UNIDAD Y ay ENT NAY A Ne NOTA a A 4 INSTALE 4 TORNILLOS A pl lodo Saez wee PARA FIJAR PARTE MANUAL PARA ERA AAA TRASERA DEL ENFRIADOR OBTENER SEDES INFORMACI N Eoee SOBRE LA HE INSTAL
4. of the unit 93 lbs and will accept the mounting hardware INSTALLATION PROCEDURES 1 Open carton unpack unit remove and verify all parts are included OPEN UNIT UP SECURE FAN HOUSING 3 PULL BACK GUARD AWAY FROM UNIT EXTEND HOUSING AND ATTACH IT TO zif COOLER BODY FRONT FE WITH 12 SCREWS WY LSSSSS Sa 1 REMOVE 4 SCREWS FROM BACK MEDIA GUARD 2 PUSH UP ON BACK GUARD NN ARS UN Zar iA i i MY N AN NN N N AN WANA NN WM N AS ON E i 4 AA OOOO f EAA NL N ANI A WN NN WN ANN iy EY TH CO NN ON 2 Hold unit in upright position Remove four screws 2 top and 2 bottom securing back media guard and separate front and back sections Pull fan housing out as far as 1t will go until fully engaged in mating part Secure in place with 12 screws supplied 3 From exterior place front section in place and close window to help hold it in place while installing mounting brackets 4 Placeabubblelevel spacen TOENSURE on unit To ensure FLUSH SQUARE cooler is level before INSTALLATION NOT SUPPLIED installing 5 Install mounting brackets as shown in the illustration above 4 MINIMUM OPTIONAL MOUNTING 2 PLACES MINIMUM 14 APART rf s IMA AAA W
5. the water pump on and off PLEASE REFER TO OWNER S MANUAL FOR FULL DETAILS OF OPERATION AND MAINTENANCE OF THE MCP44 PN 72584 11 13 Gu a de puesta en marcha de MCP44 Lea y siga las normas de seguridad incluidas en el Manual de instrucciones antes de instalar o poner en funcionamiento este producto NOTA Esta gu a de puesta en marcha solo proporciona la infor maci n b sica de instalaci n Recomendamos enf ticamente consultar el Manual del usuario para obtener las Instrucciones completas de instalaci n y mantenimientos Nota importante sobre este enfriador Esta unidad est calculada para enfriar 1600 pies cuadrados Para que el enfriador de ventana enfr e esta rea de manera efectiva debe haber una entrada de aire exterior y por lo menos una salida puerta o ventana en cada habitaci n donde el enfriamiento se desea NOTA Este enfriador NO funciona en habitaciones cerradas Aire pa _erir o aa Abra la ventana de aproximadamente 4 6 pulgadas PIEZAS INCLUIDAS EN LA CAJA Unidad de enfriamiento soportes de montaje 4 Separadores de acorde n 2 y juego de piezas MN ON N AK AK IN NN ANA gt N A ka r INN WN aA Para instalar este enfriador se necesitan al menos dos personas HERRAMIENTAS Y MATERIALES NECESARIOS PARA LA INSTALACI N Taladro con cable o inal mbrico Silicona o masilla para todo tipo de
6. ACI N HA RE m EMPRATRADA seso Y EL PLUG IN DE o j OPCIONES DEL TERMOSTATO 3 EMPUJE HACIA ABAJO EN LA PARTE POSTERIOR oo CONEXION DE AGUA 1 Conecte un grifo de manguera VALVULA DE APAGADO estandar al grifo que se usara como suministro de agua 2 Instale una tuberia plastica o de cobre al grifo de manguera y conecte el otro extremo a la valvula de flotador de bronce en el lateral del enfriador NOTA Las tuberias de agua se envian sin conectar Retire la boquilla insertada en el extremo de la tuberia de desborde antes de proceder TUBERIAAL ENFRIADOR DE PLASTICO O COBRE GRIFO DE MANGUERA CONEXI N DE MANGUERA EST NDAR 3 Conecte el extremo inferior de la tuber a de agua principal en la toma de entrada de la bomba Inserte la manguera de desborde en una de las ranuras en el interior de la conexi n de drenaje de desborde Vuelva a insertar la boquilla en la tuber a de desborde TUBO DE VUELVAA INSTALAR LA BOQUILLA EN LA TUBER A DE DESBORDE DESPUES DE INSTALAR LA TUBER A A TRAVES DE LA GRIFER A DE REBOSE TUBER A DE AGUA PRINCIPAL AN A Y Y ae N L BOQUILLA A BOMBA NO SE MUESTRA LA MALLA DEL FILTRO PARA MAYOR CLARIDAD CONEXI N DE DRENAJE DE DESBORDE TOMA DE ENTRADA DE LA BOMBA EMPAQUETADURA FONDO DEL TANQUE CONTRATUERCA 4 Instale el drenaje de desborde en el orificio de la parte inferi
7. INDOW SILL CREWS WINDOW SILL BRACKET WINDOW SILL ee 7 SAT e dal TEE SCREW _ 6 After the cooler is installed affix accordion closeout panels using the adhesive backing or you may secure them with screws not included but ensure the screws do not interfere with the fan blades Use all weather caulk to seal any gaps around the unit 1 CONNECT WATER 7 Connect to water SUPPLY HOSE source as outlined in next panel then close unit up replacing four screws 2 SET BACK GUARD IN PLACE ON UNIT 4 INSERT 4 SCREWS TO SECURE BACK MEDIA GUARD ne YT TT fi M f UN RH PEF O NOTE REFER TO MANUAL FOR INFORMATION ON IN WALL J INSTALLATION AND PLUG IN THERMOSTAT OPTIONS WATER CONNECTION 1 Attach a standard sillcock to the water SHUT OFF VALVE faucet to be used as water source 2 Install plastic or copper line to sillcock PLASTIC OR and connect the other end to the brass oe float valve on the side of the cooler NOTE Water lines are disconected for shipping remove and retain nipple inside overflow line before proceeding 3 Connect water line to pump inlet and insert overflow line into a side slot on the SILLCOCK STD HOSE CONNECTION REINSTALL NIPPLE INTO
8. Start Up Guide for MCP44 Read and follow the Safety Rules in the Instruction Manual before installing or operating this product NOTE This start up guide only provides basic set up information We highly recommend consulting the Owner s Manual for complete installation and maintenance instructions Important Note About This Cooler This unit 1s rated to cool 1600 sq ft For the window cooler to effectively cool this area there must be an outside air Inlet and at least one Outlet window or door in each room where cooling is desired NOTE This cooler WILL NOT work in a Closed Room Cool U MM N N A NN IN NN ATT AK NN ZF Open window approximately 4 6 inches ITEMS INCLUDED IN CARTON Cooler Unit Mounting brackets 4 Accordion spacers 2 and hardware kit Installation of this cooler requires at least two persons TOOLS AND MATERIALS NEEDED FOR INSTALLATION Power or cordless drill Silicone or other all weather caulk Drill bits for drilling pilot holes 1 4 copper or plastic tubing Adjustable wrench Sillcock valve Phillips head screwdriver Bubble level IF YOU HAVE QUESTIONS OR FIND PARTS MISSING CALL 1 800 643 8341 BEFORE RETURNING TO RETAILER SELECTION OF WINDOW Verify there is a 22 width and height clearance on selected window Ensure window structure sill and frame are strong enough to support the operating weight
9. or del enfriador Consulte la ilustraci n NOTA Mientras ajusta el m dulo de drenaje tenga cuidado de no retorcer la arandela de goma ya que esto puede provocar filtraciones NO AJUSTE EN EXCESO NOTA Es posible que deba ajustarse levemente el flotador despu s del env o Debe instalarse para mantener un nivel de 2 de agua en el dep sito NOTA Si se instala una bomba de purga puede conectarse una manguera de agua est ndar al drenaje de desborde o al grifo de manguera para la descarga de agua INSTRUCCIONES DE USO 1 Con el agua corriendo la ventilaci n adecuada y la unidad conectada encienda el enfriador presionando Es el bot n de encendido On Off Encendido Apagado led en el panel de control o en el control remoto O HI MED LO ON OFF NOTAS El ajuste de encendido predeterminado para la unidad es Ventilador en HIGH Alto y Bomba en ON Encendido Luego la unidad arrancar en el ltimo ajuste utilizado A fin de obtener mejores resultados encienda la bomba unos minutos antes que el ventilador para que el medio ya est h medo 2 Al presionar el bot n Fan Ventilador en el panel de control o en el control remoto se alterna entre High Alto Medium Medio y Low Bajo 3 Al presionar el bot n Pump Bomba en el panel de control o en el control remoto se enciende o apaga la bomba de agua CONSULTE EL MANUAL DEL USUARIO PARA OBTENER LOS DETALLES COMPLETOS DE OPERACION Y MANTENIMIENTO DEL MCP44
Download Pdf Manuals
Related Search
Related Contents
RIDGID AC1030 Saw User Manual Outdoor LP Gas Barbecue Grill Model No. GBC1025WE-C T05 Aditivo Orde-Latex CU`SPー - 清涼飲料自動販売機の設置・管理・有線放送 Les thèmes du portail – Manuel d`utilisation Telemecanique Siemens PPI Protocol XBT N/R GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150 User Answers to Exercises Sistema IS40/Triton Copyright © All rights reserved.
Failed to retrieve file