Home
Cool-A-Zone C100 Use and Care Manual
Contents
1. ii ia i User Manual C100 2052 Long Point Houston TX 77055 888 827 1675 info coolazone com Facebook com CoolAZone gt Twitter com CoolAZone HUB WBENG D Women s Business Enterprise WBEA www coolazone com Table of Contents amp How It Works Page 2 Installation amp Set Up Page 3 Dust Screen amp Side Panel Page 4 Managing the Water Reservoir Page 4 LCD Button Panel amp Remote Control Page 5 Basic Operation amp Powering On Page 6 C 100 Controls Pages 7 8 Using the Timer Feature Page 9 Routine Maintenance Page 9 Basic Troubleshooting Page 10 Circuitboard amp Specifications Page 11 Contact Information Page 12 How Cool A Zone Works Cool A Zone s C OO L ie of REFRESHING AIR BLOWS HOT OUT AIR COMESIN Cool A Zone s water reservoirs hold up to 37 gallons With add on reservoir capacity you can run your Cool A Zone longer without refilling WENG G HUB WENG www coolazone com 2 Cool A Zone s beltless direct powered Cool A Zone s stainless steel fan Evaporative Pad Installation INSTALLATION AND INITIAL SET UP If the fan must be placed close to a wall or other obstacle try to keep a distance of 2 to 3 feet between the wall or obstacle and the face of the cooling pads When placing the fan take the following into consideration a Uninterrupted fresh air should be made available to the cooling pad side of the unit for best result
2. power source Is correct Check for any shaking or odd vibrations when running the C 100 aN www coolazone com 10 Cool A Zone can not be held liable forany modifications made to the above circuit diagram by any party whether purc hasor or third party DISCONNECT The above diagram is provided asa reference POWER point only for trained and skilled professionals and BEFORE _joumeymen who have the knowledge to read circ uit WORKING diagrams understand their meaning and make such WITH THE adjustments to fuses circuits and the like FUSES OR TEEN We recommend you contact Cool A Zone at BOARD info c oolazone com if you have any questions C 100 Spo eshtiSente 1g Three Speeds Cooling Capacity 900 sa ft Maximum Air Delivery 3 03 GEM obia Fan Type Axial 140cm Water Reservoir 21 gallons Width SUI 76 Cim Height Sone 40cm Depth 25 Nf Oo Cm Depth Unit Weight 62 DS 28 K9 tes Shipping Weight 72165 65 ko Noise Level lt 62 db www coolazone com 11 Cool A Zone www coolazone com Info coolazone com 888 827 1675 9052 Long Point Houston TK 77055 Twitter com CoolAZone Facebook com CoolAZone
3. hours to 0 button begins to flicker amp you 3 If you wish you can also hit the will see that H x appears in the POWER button while the TIMER TEMPERATURE display button is flickering 3 To increase the number of hours 4 Alternatively you can hit the POWER hit the SPEED button on the panel button after the TIMER has activated or ncrease Airflow button on the and then hit the POWER button remotre control again 4 You cannotset the timer for more When in Stand By mode the TIMER than 9 hours function will count down to power ON 5 Once the desired hours are set do the C 100 If the C 100 is already on the not press any other buttons after 5 TIMER function will count down to tum OFF seconds the TIMER will activate your C 100 unit Routine Maintenance THE FOLLOWING ARE BEST PRACTICES FOR MAINTAINING YOUR C 100 1 Shell Cleaning We recommend soap amp water or a mild cleaner with a soft cloth Avoid abrasive cleaners or alcohol based chemical cleaning agents 2 Pad Cleaning it is recommended you remove the pad and clean using a soft brush once every two weeks more frequent if being in used in a dust heavy environment 3 Draining the Tank We generally advise you drain water at the end of every day s use to increase longevity 4 Tank Cleaning we recommend that the tank be cleaned by hand ona schedule that suits your needs best especially in more humid climates or dust heavy environments
4. 5 Storing the C 100 if you have been using your C 100 and need fo store it please ensure that you have cleaned amp dried your tank cleaned the drain outlet cleaned the pad amp shell and store covered until needed again Ensure that when doing any cleaning or maintenance that your C ool A Zone C 100 unit is powered OFF and UNPLUGGED www coolazone com 9 Check if C 100 is plugged in and outlet is working oe eels Replace Fuse Power On Controller breakdown Replace Controller Electrical Mainboard is Replace Mainboard broken or faulty Low or no Water Add water VENTILATION Mode is Activate COOL activated Mode The Air is Not COOL button not i Replace Controller Cool working Pump breakdown Replace Pump Electrical Mainboard is Replace Manboare broken or faulty i PE AE DA Replace Controller 3 No Airflow working p Detected Fan Motor breakdown Replace Motor Unplugged or faulty power source N Clean Water Tank 4 Odd or menar Tone thoroughly replace Unpleasant Odor with fresh water Dirty Pad Clean the Pad Dirty or stale water is in DEBUGGING AND INSTALLATION C HEC KUST Inspect drain pipe for stable connection and assembly Check the water supply to be sure there is no leakage Check if the power supply connection is plugged in properly Check for debris in the water tank Check for any foreign matter in the air compressor Ensure that your outlet is properly rated
5. LEIET screws the panel Drain Valve Affusion Panel To fill your Cool A Zone Draining is just as easy C 100 simply open the turn the unit off unplug Affusion Panel above then turn the drain valve and fill with water knob counter clockwise to empty the reservoir www coolazone 4 cowm 4 THE LCD BUTTON PANEL Keb Button Banel The Cool A Zone C 100 has a user friendly and easy to use LCD indication panel with one touch button features for activating timing setting and full control of your C 100 The diagram below outlines what the various buttons and indicators mean Note that the central area in white below is an indication panel whereas the grey area denotes the buttons Pages 7 amp 8 will go into detail on the various Buttons amp Indicators ANION ON OFF REC EIVER DISPLAY TIMER timer anion swing SWING ON OFF LOW WATER TIMER SWING POWER Tum the device on off AIR SPEED CONTROL Increase or decrease air flow ANION CONTROL Start or stop Anion function Not sure If you hit the right button Always check the C 100 LCD indicator panel status lights to see TIMER BUTTON REMOTE TEMPERATURE SHOW SHOW VENITILATION AIRFLOW INDICATOR INDICATOR INDICATOR INDICATOR Activates Timer feature SPEED BUTTON POWER ON OFF COOL COOL INDICATOR ON OFF Remote Controle COOL Start or stop the Cool function VENTILATION Activat
6. es Ventilation function SWING Tums Swing function on off If the remote appears to not work Check to see if you have a clear line of sight to the C 100 www coolazone con 5 INITIAL OPERATION After ensuring the unit has adequate water for operation and that your C 100 has been plugged in turn the Cool A Zone C 100 on by pressing the power button either on the LCD Panel face or as shown on the remote control on Page 5 of this manual POWER Tum the device on off Power Buttons may be found either on the nght of the LCD Panel oron the Red Button of the remote contol POWER ON OFF Before powering up check the following Isthe unit level ls the unit s air flow unobstructed TURNING THE C 100 ON THE ARST TIME The C 100 Speed will be at Level 2 and the Cool Function will be listed as On the first time you power up your Cool A Zone C 100 PRESSING ON DURING STANDBY Turning the unit on during a state of stand by will power up the C 100 in the same mode and airflow setting in which it entered the stand by mode Make sure to adjust the settings as appropriate for your comfort after coming back from stand by www coolazone cor 6 C 100 Control Re USING YOURC 100 onors SHOW SHOW SPEED VENTILATION AIRFLOW BUTON 1 Power Button turns the unit ON or OFF 8 AG 2 Soeed Button this controls Be REP eel psesaatl pavers the air
7. es the C 100 TIMER feature allowing you to either start the unit from a start up set after a certain Number hours or SWING LOWWATER TIMER SWING ff ANION timer anion swing a J ON OFF _ INDICATOR INDICATOR INDICATOR INDICATOR stop the unit after a certain number of hours More on this function on Page 9 8 Anion Button Turns the ANION function ON or OFF as indicated by the Anion Indicator 9 Remote Receiver LCD Indicates a command received from the remote control 12 Low Water Indicator This warning light will let you know when it is time to refill your C 100 and if the water gets too low a buzzer will sound and the COOL mode will stop No buzzer will come on if you are in VENTILATION mode 13 Show Ventilation Indicator Indicates the level of ventilation being used by the C 100 14 Timer Indicator When lit indicates the TIMER function Is active 15 Swing Indicator When lit indicates the C 100 SWING function is active www coolazone m 8 Using the S100 rE WHAT THE TIMER FUNCTION DOES 1 Starts your Cool A Zone C 100 cooler automatically after n hours from the stand by state OR 2 Stops your Cool A Zone C 100 cooler automatically after n hours after being turned ON Note the TIMER function can only be set by the hour USING THE TIMER DISABLING THE TIMER 1 Press the TIMER button 1 Press the TIMER button 2 You will notice that the TIMER 2 Setthe number of
8. flow On first operation Oo 4M the C 100 will be at SPEED 2 D WW there are three Speeds ANION COOL COOL A S INDICATOR INDICATOR ON OFF being the lowest and 3 being the highest Pressing again will take you up to SPEED 3 then pressing it again will bring you down to SPEED 1 The rate of speed will be reflected on the Airflow Indicator If using the remote contol simply hit the up or down anows to contol the airflow speed see Page 5 3 The Cool Button switches the Cool A Zone C 100 trom COOL to VENTILATION modes One press will switch between the two functions The COOL mode will activate the pump and water will be used to evaporatively cool whereas the VENTILATION mode will simply circulate the air and deactivates the pump If using the remote contol there are one button each forthe COOLand VENTILATION modes see Page 5 4 The Cool Indicator When lit this indicates that the Cool A Zone C 100 is in COOL mode When unlit this inidcates the Cool A Zone C 100 Is in VENTILATION mode 5 The Airflow Indicator The lowest bar indicates SPEED 1 the middle bar indicates SPEED 2 and the highest bar indicates SEED 6 The Anion Indicator When lit the Anion function is ON when unlit The Anion function is OFF www coolazone m 7 C 100 Controlsi CCEC USING YOUR C 100 ANION REMOTE TEMPERATURE SHOW ON OFF REC EIVER DISPLAY VENITILATION TIMER 7 Timer Button Activat
9. s b Avoid blocking the air output front side of the fan Cool air released from the unit should be able to freely circulate c In order to prevent air from being re circulated ensure that the area to be cooled is properly ventilated d If your C 100 did not come with the truckles the wheel assembly legs attached please see the below instructions on how to do so Truc kle Unattached Truc kle Attached Truc kle Attaching Points Finished Assembly 1 Take two sets the Truckles above left shown unattached 2 Use the enclosed ST5x25 bolts to stable the assembled frame to the bottom of the water tank through the attaching points as shown on the left which will line uo with corresponding points on the unit 3 When completed the finished truckle body assembly area should look as shown above on the right www coolazone c om 3 Dust Screen amp lt Sice Panel ACCESSING THE DUST SC REEN AND SIDE PANEL If you need to access the Dust Screen and Side Panel on your C 100 follow the instructions below Using a Phillips crosshair Screwdriver as follows a Take the eight screws off the dust screen housing as shown in the picture below left b Once the eight screws are removed gently remove the housing and side panel to access the two 2 dust screens c Reverse the steps above and secure replace the housing to again use your Cool A Zone C 100 Remove then all genily attaching remove
Download Pdf Manuals
Related Search
Related Contents
ETESIAN MINI GUIDE RAPIDE 11 Fascicules de présentation des étangs et petits lacs de Suisse SERVICE MANUAL - Green Fit Co. Vivitek D837 data projector Eaton ePDU C14 4xGE 4xC13 2m Descarga el manual de usuario Betriebsanleitung Operating Instructions Bruksanvisning Notice d ファンタジックフィーバー 3 トゥインクルフェアリーテイル 0120 Samsung SGH-E720 Керівництво користувача Copyright © All rights reserved.
Failed to retrieve file