Home
Lux TX500E-010 Instructions / Assembly
Contents
1. e 4 Periods Per Day Calibration e Battery Free Memory Storage e 5 Minute Minimum Run Off Time For e Temporary Temperature Override Short Cycle and Compressor e Temperature Hold Protection Keyboard Lockout INSTALLATION Please read ALL of these instructions carefully before beginning installation Save them for future reference TOOLS REQUIRED e 1 Phillips screwdriver e Drill with 3 16 in 4 8mm bit e Wire Stripper Cutter CAUTION This thermostat is protected against normal minor static electric discharges however to minimize the risk of damaging the unit in extremely dry weather touch a grounded metal object before touching your thermostat LOCATION On replacement installations mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise On new installations follow the guidelines listed below 1 Locate the thermostat on an inside wall about 5 ft 1 5m above the floor and in a room that is used often Do not locate where air circulation is poor such as in a corner or an alcove or behind an open door Do not install it where there are unusual heating conditions such as in direct sunlight near a lamp television radiator register or fireplace near hot water pipes in a wall near a stove on the other side of a wall Do not locate in unusual cooling conditions such as on a wall separating an unheated room or in a draft from a stairwell door or window
2. Do not locate in a damp area This can lead to corrosion that may shorten thermostat life If painting or construction work has yet to be completed cover the unit completely or do not install it wo N O a A WARNING e Read instructions carefully before removing any wires from your existing thermostat e This thermostat should be limited to 1 5 amps per terminal and a maximum of 2 amps total higher current than this may cause damage to the thermostat e All wiring must conform to the local codes and ordinances that are in your particular location REMOVAL OF OLD UNIT 1 Turn OFF the electricity to all heating and cooling components Do not turn the electricity back on until all work is completed 2 Remove the cover and front portion of your old thermostat to expose the wiring connections 3 Write down the letters printed near each wire terminal that is used and the color of the wire that is connected to it Using the enclosed labels attach a label to each of your wires so that the letter matches the marking on your existing thermostat When they are all labeled carefully remove the wires one at a time making sure that they do not fall back inside the wall Do not allow any of the bare wire ends to touch each other or any parts on the thermostat 5 Loosen all of the screws on the old thermostat and remove it from the wall A MOUNTING 1 Strip insulation leaving 3 8 in 9 5mm bare wire ends and clean off an
3. or DOWN buttons to select the number of days of filter life that your filter is rated for Setting this value to OFF will disable the filter monitor Return the dial to the RUN position once you are finished setting the filter life To monitor the Filter Days Left or Filter Percent Left turn the dial to the AIR FILTER position The amount of filter life remaining will be shown in the clock portion of the display screen Return the dial to the RUN position once you are finished viewing the filter life remaining RESET FILTER COUNTER Once you have replaced your filter the filter life counter is reset back to its full amount remaining value by turning the dial to AIR FILTER and pressing the UP and DOWN buttons together at the same time NOTE The counter is also reset by changing the filter setting value as described above to a different number of days ADVANCED FEATURES SWING SETTING A thermostat works by turning your heating or cooling system on and off whenever the room temperature varies from the set point temperature The amount of this variation is called the swing Your system should cycle on about 3 to 6 times per hour A smaller swing number increases the number of cycles per hour so the room temperature is more precise and constant A larger swing number decreases the number of cycles per hour but saves energy in most cases To change the Swing setting turn the dial to RUN mode Hold down the NEXT button and push the HOLD but
4. switch to ON runs your system s fan continuously even if heating or cooling is not needed including when the Temperature mode switch is in the OFF position to provide air circulation only NOTE The Fan mode switch only works if your system provides a wire for the thermostat s G wire terminal PUSH BUTTONS There are four primary push buttons on the front of the thermostat The UP and DOWN arrow keys the NEXT button and the HOLD button ROTARY DIAL The LUX Speed Dial provides an easy way to quickly navigate between the different programming areas This rotary dial has five individual positions OPERATING INSTRUCTIONS SET DAY TIME Rotate the dial to the SET DAY TIME position You should see the word SET appear on the display along with the clock and a day of the week that is flashing With the day flashing press the UP button to advance the day to the desired day Press the NEXT button this should cause the time to start flashing and the day to remain on steady Using either the UP or DOWN buttons adjust the clock to the desired time The clock digits will increment rapidly if either the UP or DOWN buttons are held in the pressed position HEATING AND COOLING Basic operation of your heating or cooling system can be obtained by ensuring that the rotary dial is in the RUN position and simply moving the Temperature mode switch to either the HEAT or COOL position Prior to being set initially with your custom temperatur
5. INSTALLATION AND OPERATING INSTRUCTIONS TX500E Programmable Thermostat WARNING Use Energizer or DURACELL Alkaline Batteries Only Energizer is a registered trademark of Eveready Battery Company Inc DURACELL is a registered trademark of The Gillette Company Inc Mt Laurel New Jersey 08054 USA 52073 http www luxproducts com Thank you for your confidence in our product To obtain the best results from your investment please read these instructions and acquaint yourself with your purchase COMPATIBILITY This thermostat can be used with most single stage 24 volt gas oil or electric heating and or cooling systems single stage heat pumps or gas Millivolt heating systems It cannot be used with 3 wire zone valves 120 volt heating systems or multi stage heat pumps Ask your dealer for other LUX thermostats to control those systems FEATURES LCD Liquid Crystal Display Set Temperature Buttons Fan Mode be Switch Software Em 6 35 s5 33 fad Reset Button A Temperature n A ran TemeRATURE Mode Switch n K ae 2 oF BE LUX A Hote mA TX500E Quick Reference Speed _ J Door Instructions Dial e Small elegant design e F C Temperature Display e Exclusive LUX Speed Dial e 12 24 Hr Clock Display e Air Filter Monitor e Adjustable Temperature Differential e 5 2 Day Programming Cycle Rate e Energy Star Compliant e User Temperature Offset
6. component information for brand new instal lations or for unreferenced wires SETUP OPTIONS SYSTEM TYPE SETTING This setting tells the thermostat about the type of heating and cooling equipment that it is controlling so that the system is operated properly There are two operating modes based on your system type Furnace Fn or Heat Pump HP If you have a Furnace ensure this is set to Fn If you have a Heat Pump ensure this is set to HP Install two new Energizer or DURACELL AA size alkaline batteries before continuing further Ensure that the batteries are installed in the proper direction as per the markings shown in the battery tray With the thermostat powered by batteries press and hold the HOLD button and then press the Hardware Reset button once on the back of the unit s circuit board Continue to hold the HOLD button until SYS is shown on the LCD screen Use the UP or DOWN buttons to toggle between Fn and HP modes When you are finished press NEXT This setting is now complete and will not change unless you adjust it again This is true even in the event of a power failure or if a reset button is pressed NOTE All of the settings options and components listed in this section are located on the rear of the thermostat on the circuit board HARDWARE RESET The hardware reset is a push button that is located on the right edge of the circuit board just above the batter
7. e Reset button Neither of the Mode slide switches are locked out When the Keylock is activated a padlock icon will be visible in the area above the clock as shown below NOTE The Keylock will be disabled if the Hardware Reset button is pressed PROGRAMMING For all of the programming areas that are described below this thermostat provides four independent periods per day for Heat mode and Cool mode they are MORN DAY EVE and NITE Each period ends at the start time of the following period The programs for each Temperature mode are programmed separately When you perform a Software Reset an Energy Star approved program is inserted into all of the program periods You can use these default programs or alter any portion of them to suit your own preferences When setting the program items the value that is flashing is the item that you can change at that time SET WEEKDAY PROGRAM Select either HEAT or COOL with the Temperature mode switch Rotate the dial to WEEKDAY PROGRAM You will be programming all five weekdays at the same time The first period is MORN Using the UP and DOWN buttons set the start time for this period and then push the NEXT button to proceed Now set the desired set temperature for the MORN period using the UP and DOWN buttons and push NEXT to proceed Now set the start time and set temperature for the DAY period pushing NEXT after each to advance Continue with these same steps to set the start time and
8. e program and also after a Software Reset the thermostat will follow the default Energy Star approved temperature routines that are preset within the thermostat s memory as shown below COOL MODE MORN 6 00 AM 70 F 21 C 6 00 AM 78 F 26 C 8 00 AM 62 F 17 C 8 00 AM 85 F 29 C 6 00 PM 70 F 21 C 6 00 PM 78 F 26 C 10 00 PM 62 F 17 C 10 00 PM 82 F 28 C MINIMUM RUN TIME DELAY This is determined by the thermostat and controls the minimum length of time that the thermostat must remain with Heat or Cool either On or Off before it will automatically switch to the alternate On or Off state This feature prevents rapid or short cycling and provides compressor protection for cooling equipment The time amount for this delay is fixed at 5 minutes between on or off load changes TEMPERATURE OVERRIDE A Temperature Override occurs in Run mode in either Heat or Cool anytime the user adjusts the set temperature to a value that differs from the stored program temperature for that day and time When the thermostat is in an Override the word Override will appear in the temperature area of the display The thermostat will maintain thermal control using this new set temperature until the start of the next program period time is reached At the start of the next program period the set temperature will return to its programmed value To enter an Override in either Heat or Cool mode pus
9. er life will be displayed when the rotary dial is turned to the AIR FILTER position In the Percent mode the display will count down the percentage of air filter life remaining before a filter change is recommended In the Days mode the display will count down the number of calendar days remaining before a filter change is recommended Switch position OFF is Percent mode and ON is Days mode FRONT PANEL ITEMS SOFTWARE RESET The software reset is a small recessed push button that is located right above the NEXT button This button can be pushed with a pencil or the end of a paper clip This reset clears all of the heating and cooling programs filter settings and other user changeable preferences to their default values You should write down your heating and cooling program times and temperatures prior to using the software reset MODE SWITCHES There are two mode switches on the front a Temperature mode switch and a Fan mode switch The Temperature mode switch has three positions HEAT OFF and COOL In the winter set the system switch to HEAT to control your heating system In the summer set the switch to COOL to control your air conditioner In the spring and fall or when the windows are open you can set the switch OFF The Fan mode switch has two positions AUTO and ON Setting the Fan mode switch to AUTO automatically runs your system s blower fan as required only during heating and cooling activation Setting the Fan mode
10. ery compartment to ensure proper installation When finished hang the top of the unit by the tabs at the top corners of the base then snap the bottom of the unit into place Do not use unnecessary force If the body does not snap into place easily remove the body re hang it from the tabs and try again TECHNICAL ASSISTANCE If you have any problems installing or using this thermostat please carefully and thoroughly review the instruction manual If you require assistance please contact our Technical Assistance department at 856 234 8803 during regular business hours between 8 00AM and 4 30PM Eastern Standard Time Monday through Friday You can also receive technical assistance online anytime day or night at http www luxproducts com Our web site offers you answers to the most common technical questions and also permits you to email your questions to our technical support staff at your convenience WARRANTY Limited Warranty If this unit fails because of defects in materials or workmanship within three years of the date of original purchase LUX will at its option repair or replace it This warranty does not cover damage by accident misuse or failure to follow installation instructions Implied warranties are limited in duration to three years from the date of original purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Please return malfunctioning or defec
11. h either the UP or DOWN button once and the set temperature will begin to flash Push either the UP or DOWN button to the new desired set temperature value An Override may be cancelled by rotating the dial changing the Temperature mode switch or by initiating a Temperature Hold 2008 LUX PRODUCTS CORPORATION ALL RIGHTS RESERVED TEMPERATURE HOLD A Temperature Hold is similar to an override but is used for maintaining a constant set temperature for a longer time duration Once a Hold is initiated the thermostat will maintain the Hold set temperature indefinitely A temperature hold may be used for days weeks or even months at a time To enter a Hold push the HOLD button once and the word Hold will appear in the temperature portion of the screen along with the set temperature flashing While the set temperature is flashing push either the UP or DOWN button to the new desired set temperature value To cancel a Hold press and release the HOLD button once again rotate the dial or change the Temperature mode switch AIR FILTER MONITOR The Air Filter Monitor counts the number of days and the amount of usage since your furnace filter has been replaced In Run mode the CHANGE FILTER indicator will appear when the remaining filter days have reached zero and the filter should be changed To set and use the Air Filter Monitor turn the rotary dial to AIR FILTER Press NEXT and the Filter Days Left value will start flashing Use the UP
12. set temperature for the EVE and NITE program periods When you are finished setting all four periods you may continue pushing the NEXT button through all four periods to review your entries or turn the dial to RUN if you are finished These same programming steps for all four periods must be performed in both Heat and Cool Temperature modes independently SET WEEKEND PROGRAM Turn the dial to WEEKEND PROGRAM You will be programming both Saturday and Sunday at the same time You will begin with the start time of the MORN period and use the same procedures that were performed while setting the Weekday Program periods using the NEXT button to advance through the values Return the dial to the RUN position when you are finished BATTERIES AND MAINTENANCE This thermostat is powered by two AA alkaline batteries The batteries should be replaced AT LEAST once per year or sooner if the LOW BAT battery symbol appears in the lower left portion of the display screen as shown below To replace the batteries in the thermostat remove the thermostat s body from the base plate attached to the wall by pressing the thumb latch at the bottom center of the unit and swinging the body towards you up and away from the base Remove the used batteries from the battery tray and discard appropriately Install two new Energizer or DURACELL AA size alkaline batteries into the battery tray Observe the polarity markings shown in the batt
13. tive units to the location from which the purchase was made along with proof of purchase Please refer to TECHNICAL ASSISTANCE before returning thermostat Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit Some states do not allow the exclusion of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Applicable in the U S A and Canada only
14. ton once then let go of both The words SWING and SET will appear on the screen with a number Use the UP DOWN buttons to change the number value between 1 and 9 Number 1 is the default setting Press the NEXT button to accept the setting and return to normal Run mode TEMPERATURE CALIBRATION The internal temperature sensor in this thermostat is accurately calibrated at the factory The Temperature Calibration feature allows you to manually offset the measured temperature by as much as plus or minus 5 F 3 C degrees from its original value This feature can be useful to match this thermostat to another one or more if multiple thermostats are used in the same home To change the Temperature Calibration turn the dial to RUN mode and place the Temperature mode switch in the OFF position Hold down the UP button and push the DOWN button once then let go of both The words CAL and SET will appear on the screen with a number Use the UP DOWN buttons to change the number value between 5 F 3 C and 5 F 3 C degrees 0 degrees of correction is the default setting Press the NEXT button to accept the setting and return to Run mode KEYLOCK To prevent tampering with any of your settings or temperatures most of the front panel buttons can be locked out by pressing the following four button sequence NEXT NEXT NEXT HOLD This sequence of keys will lock and also unlock these items UP DOWN NEXT HOLD the Rotary Dial and the Softwar
15. y corrosion Fill wall opening with non combustible insulation to prevent drafts from affecting the thermostat Remove the body from the thermostat s base by pressing the thumb latch at the bottom center of the unit and swinging the body away w N NOTE If you are mounting the base to soft material like plasterboard or if you are using the old mounting holes the screws may not hold Drill a 3 16 in 4 8mm hole at each screw and insert the plastic anchors provided 4 Hold the base against the wall Route the wires through the hole below the terminal block Position the base for best appearance to hide any marks from an old thermostat Attach the base to the wall with the two screws provided CONNECTING THE WIRES 5 Wires must be trapped between the black clamps and the brass terminals as shown here 6 Being careful not to overighten them securely tighten all of the electrical terminal screws including any unused ones NOTE When you are finished performing your installation and setup options please remove the thin plastic film that is protecting the LCD display screen on the front of the thermostat This plastic may or may not be present and is evident by the appearance of fake digits appearing on the display screen WIRING INFORMATION Complete heating and or cooling system wiring can be found in the WIRE IDENTIFICATION AND WIRING SCHEMATICS section of this instruction sheet The schmatics shown provide
16. y location This reset button is used by the thermostat to reset the unit s clock and read the position of all of the option switches When any of the following items are changed the hardware reset button must be pushed for the change to be recognized User temperature programs are not erased when a hardware reset is performed HEAT FAN CONTROL JP1 This setting defines the fan operation FAN while in Heat mode and when the fan ELECTRIC ii GAS is in Auto This setting has no effect while the thermostat is in Cool mode or if there is no blower fan connected to the G wire terminal GAS Use this setting if you have a Gas or Oil heating system In the GAS setting the heating system itself controls the operation of the blower fan if equipped ELECTRIC Use this setting if you have a Heat Pump or Electric heating system In the ELEC setting the heating system requires the thermostat to control the operation of the blower fan The following option settings are all located within a group of small switches labeled 1 through 3 as shown below and are located in the center of the circuit board TIME FORMAT This determines how the thermostat displays the clock and all other times on the screen Switch position OFF is 12 HR and ON is 24 HR TEMPERATURE SCALE This determines how the thermostat displays all temperatures on the screen Switch position OFF is F and ON is C FILTER DISPLAY This determines how the remaining filt
Download Pdf Manuals
Related Search
Related Contents
セガトイズ/米国ハスブロ社が放つ新世代音楽ロボット 全世界初公開 11 "取扱説明書" Philips SHL5001 technical specification of mobile flash butt welding machine Daughtercard User Manual (PDF format) Plantilla indicadores Pisys - Fedegan Verbatim USB Flash Drive 2GB Actiontec GT784WNV Quick Reference Guide GSP-1700 - Global Marine Networks Copyright © All rights reserved.
Failed to retrieve file