Home

Delta Breez SMT130M Instructions / Assembly

image

Contents

1. A ELTA oreez Smart MODELS SMT 130 SMT130H SMT130M SMT150 SMT150D INSTALLATION AND OPERATING INSTRUCTIONS VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION 1 Make sure that the electric service supply voltage is AC 120V 60Hz 9 2 Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety 10 and Health Act OSH Act 3 Always disconnect the power source before working on or near the ventilating fan motor or junction box 4 Protect the power cord from sharp edges oil grease hot surfaces chemicals or other objects 5 Donot kink the power cord 6 Do not install the unit where ducts are configured as shown in Fig A 7 Provide suction parts with proper ventilation 8 This unit is UL listed for use over a bathtub or shower when Solid state controls may cause harmonic distortion which can cause a motor humming noise NEVER place a switch where it can be reached from a tub or shower Not to be installed in a ceiling thermally insulated to a value greater than R40 This is required for installation in Canada only Turning angle too large Duct shrink Elbow near the body Too many elbows Body c s installed in a GFCl protected branch circuit Fig A 9 These ventilating fans are intended for residential usage only CAUTION WARNING 1 For general ventilating use onl
2. the joist or stud using four nails to ensure a solid quiet installation Fig E amp F Pull existing ductwork E Screw from Insert tab into hole in MO mousing Parts Bag housing Install the housing I using suspension brackets 1 Sliding suspension brackets available to allow for positioning of housing anywhere between joists up to a span of 24 2 Insert the suspension brackets into the channels on the housing Make sure the tabs face up as shown Fig C 3 Extend the suspension brackets to the width of the joists Hi Hold the fan in place by wrapping the suspension bracket n tabs around the bottom of the joist Make sure the fan body e is level and perpendicular to the joist Fig D D is 4 Ensure that the distance between the ceiling and fan body is Le appropriate for mounting the grille Fig F Install the housing HI existing ceiling installation 5 Secure the suspension brackets to the joists with nails or using the tapping screws 4x25 through holes near nails Position the housing so that it is centered in the existing ceiling 6 Secure the suspension bracket to the fan body using the opening make sure the housing is flush with the finished ceiling screws 8 32 x 1 4 Nail the housing in place and then drive the nails through the housing where indicated by arrows Fig
3. A and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities 5 When cutting or drilling into the wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted ventilating fans must always be vented to the outdoors 7 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 Do not use this unit with any other solid state control device For models of SMT130 SMT130H SMT150 SMT150D For model of SMT130M Tapping Screw 4x25 Screw 8 32x1 4 Duct connector Xp oreez MODELS SMT130 SMT130H SMT130M SMT150 SMT150D Page 2 Screw Ta Suspension bracket I 13 318 5mm Suspension bracket I 13 318 5mm INSTALLATION Attach duct connector Option1 Attach the duct connector from outside and secure by using one screw 8 32x1 4 Insert tab into hole in housing Bottom of Joist Fig D Install the housing II using mounting tabs Slotted tabs are provided to position the housing flush with 1 2 ceiling material Bend the tabs outwards 90 Use a screw driver if desired and position the housing so that the tabs rest against the bottom edge of the joists or front of the stud Nail the housing to
4. DE SWITCH e N GREEN e GRD A ELTA Pp oreez MODELS SMT130 SMT130H SMT130M SMT150 SMT150D Operation Delay time control lt TR SMT130M amp SMT150D s or Humidity preset control SMT130H Low speed air volume preset control SMT130H SMT130M SMT150D SMT150D control options TIME min CFM 2 SMT130M control options TIME min CFM SMT130H control options oO soo Single Models SMT130 SMT150 1 Single speed control mode Turn the POWER switch on to operate at single speed mode the LED indicator will be green Humidity Model SMT130H 2 Humidity control mode Turn the POWER switch on to operate at humidity control mode the LED indicator will be blue When the ambient humidity is higher than the user adjustable set point the fan will run at full speed When the ambient humidity is lower than the set point the fan will continue to run at the full speed until a 10 minute time delay has elapsed and then will automatically change to the user adjustable low speed airflow 3 Full speed mode Turn the MODE switch on to operate at full speed mode the LED indicator will be amber Factory setting low speed airflow 70CFM humidity 60 RH Note Humidity tolerance is about 10 Mot
5. F 60 C CLEANING 1 Pull down the springs to remove the grille 2 Wash and clean the grille Use non abrasive kitchen detergent and wipe dry with a new cloth 3 Using a cloth dampened with non abrasive kitchen detergent remove any dirt from the ventilating fan Wipe dry with a new cloth 4 Replace the grille DIMENSIONS 70 x vB A 556 Unit Inches mm SPECIFICATIONS Power Air Flow Model No Frequency o rsp o irsp Weight Note W CFM Single Sensor Motion Sensor SMT130H Single SMT150D 120 30 puai Speed Note Design and specifications subject to change without notice WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc Delta Electronics warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions y During the warranty period a replacement for installation by the consumer The warra other costs incurred in the troubleshooting for any defective product will be supplied free of charge nty provided herein does not cover charges for labor or repair removal and installation service 2 All returns of defective parts or products must include the product model number and must be made through an authorized Delta E
6. G 7 Follow steps 2 to 6 of the installation instructions to Re complete the installation work a Suspension Bracket Tab Face As breez Smart MODELS SMT130 SMT130H SMT130M SMT150 SMT150D Page 3 Duct connection pee rr N WS SON z GROUND WHITE b Inside Outside aa ON OFF SWITCH sA PS purchase separately SWITCH BOX T AO AA N oie Body Duct a eh a Ceiling Gradient amo erb l ADN s 1 xX2 X EN wl DA WIRING S MODE POWER ON PLATE SWITCH SWITCH X 120 VAC Fig H LINE IN 1 Insert the duct into the duct connector and tape all ductwork 4 Using wire nuts not provided connect the house power connections to make them secure and airtight Fig H cable to the ventilating fan wires 5 14 AWG 2 1 mm is the smallest conductor that shall be used 2 Install the duct with a gradient 1 2 to the outside ie for branch circuit wiring Connect wiring Grille attachment 1 Follow all local electrical and safety codes 1 Insert the motion sensor unit into the grille Fig I only for SMT130M 2 NEVER place a switch where it can be reached from a tub or shower 2 Insert the mounting springs into the slots and mount the 3 Connect wires as shown in wiring diagrams SHE Othe ReGyarig Mo
7. ion Model SMT130M 4 Motion control mode Turn the POWER switch on to operate at motion control mode When motion is detected the fan will run at full speed mode the LED indicator will be amber When motion is not detected the fan will continue to run at the full speed until the user adjustable time delay has elapsed and then will automatically change to the user adjustable low speed airflow the LED indicator will be green Factory setting low speed airflow 70CFM time delay 15 minutes Dual Speed Model SMT150D 5 Low speed control mode Turn the POWER switch on MODE switch is off to operate at the user adjustable low speed airflow the LED will be green 6 Full speed control mode Turn the POWER switch amp MODE switch on to operate at full soeed mode the LED indicator will be amber When the user turns the MODE switch off the fan will continue to run at the full speed until the user adjustable time delay has elapsed and then will automatically change to the user adjustable low speed airflow the LED indicator will be green Factory setting low speed airflow 70CFM time delay 15 minutes MAINTENANCE WARNING Disconnect the power source before working on the unit Routine maintenance must be done every year Page 4 CAUTION 1 Never use gasoline benzene thinner or any other such chemicals to clean the ventilating fan 2 Do not allow water to enter the motor 3 Do not soak resin parts in water over 140
8. lectronics d Repaired or replacement products will be shi istributor Authorized returns must be shipped prepaid pped by Delta Electronics F O B shipping point Ww Delta Electronics shall not be liable for any indirect incidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict product liability or otherwise This warranty does not extend to fluorescent lamp starters and tubes The warranty does not cover if user does not comply with manufacturer s installation manual To qualify for warranty service you must notify Delta Electronics at the address or telephone number below Delta Electronics shall have no liability to the original owner user with respect to any defect caused by abuse misuse neglect improper transportation or storage improper testing improper installation improper operation improper use improper maintenance improper repair improper alteration improper modification tampering or accident of products or parts thereof or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products specifications is Ov WM Sal Address 4405 Cushing Parkway Fremont CA 94538 US Toll Free Number 1 888 979 9889
9. tion Model SMT130M Single Speed Models SMT130 SMT150 Celling A JUNCTION BOX SWITCH BOX BLACK sie Oon O L WHITE POWER SWITCH e N GREEN GRD WHITE D u Wah Sensor unit i GROUND SA eal ty ON OFF SWITCH bare SS e purchase separately SWITOHBYX E a M p i AN COO lt gt La ead S Gri is LLL aR LED aves oe a Grille Zz aS jj z a Fig 7 q f a E a A AN p POWER 9 N PLATE SWITCH 120 VAC LINE IN Humidity Model SMT130H Dual Speed Model SMT150D JUNCTION BOX SWITCH BOX OFF BLACK a Oon O gt L WHITE POWER SWITCH e N BLUE On O WHITE MO
10. y Do not use to exhaust TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING hazardous or explosive materials and vapors Not for use in cooking areas Fig B 1 Use this unit only in the manner intended by the o gt Tis progucumust properly Sonnet penne grounaing manufacturer If you have questions contact the conductor of the supply circuit manufacturer 4 To reduce the risk of injury to persons install the fan at least 7 2 Before servicing or cleaning the unit switch the power off at feet 2 1m above the floor the service panel and lock the service disconnecting means to Cooking area Do not install above or prevent the power from being switched on accidentally When e 2 E icaree a the service disconnecting means cannot be locked securely k J fasten a prominent warning device such as a tag to the Va 7 service panel x or _ Boy 4 3 Installation work and electrical wiring must be done bya f a qualified person s in accordance with all applicable codes and standards including fire rated construction nse for quipment J 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning Fig B equipment to prevent back drafting Follow the heating SUPPLIED ACCESSORIES equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFP

Download Pdf Manuals

image

Related Search

Related Contents

PWR18-2TP - TestMart  Stazioni di Miscelazione Acqua - Vapore con valvola  取 扱 説 明 書  Guide Administration v. 2015  

Copyright © All rights reserved.
Failed to retrieve file