Home

Delta Breez SIG110L Instructions / Assembly

image

Contents

1. VENTILATION FAN LIGHT NIGHT LIGHT READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION 1 Make sure that the electric service supply voltage is AC 120V 60Hz 2 Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA 3 Always disconnect the power source before working on or near the ventilating fan motor or junction box 4 Protect the power cord from sharp edges oil grease hot surfaces chemicals or other objects 5 Donot kink the power cord 6 Do not install the unit where ducts are configured as shown in Fig A 7 Provide suction parts with proper ventilation 8 This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit 9 These ventilating fans are intended for residential usage only WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch the power off on the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by
2. IG110L SIG110HL SIG110DL Page5 DIMENSIONS 14 14 355 6 055 8 Unit Inches mm Air Flow Modelno Voltage Frequency qirsp Weight Power Mote CFM i SIG8OL 120 60 80 10 7 48 0 Single Speed SIG110L 120 60 110 10 7 53 0 Single Speed SIG110HL 120 60 110 10 7 53 0 Humidity Sensor SIG110DL 120 60 110 10 7 53 0 Dual Speed Note Design and specifications subject to change without notice WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc Delta Electronics warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions lo N ub w a N During the warranty period a replacement for any defective product will be supplied free of charge for installation by the consumer The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting repair removal and installation service All returns of defective parts or products must include the product model number and must be made through an authorized Delta Electronics distributor Authorized returns must be shipped prepaid Repaired or replacement products will be shipped by Delta Electronics F O B shipping point Delta Electr
3. LLOW O Q o Oon gt L WHITE NIGHT LIGHT SWITCH OO e gt N OFF BLACK Do OVO o Oon gt L WHITE POWER SWITCH OVO e gt N BLUE O Q d Oni gt L WHITE MODE SWITCH OO e gt N GREEN e GRD RED BLUE os BLACK YELLOW emma GROUND HITE bare ON OFF SWITCH purchase separately SWITCH BOX NIGHT LIGHT MODE POWER LIGHT SWITCH SWITCH SWITCH SWITCH 120 VAC LINE IN 3 4 Using wire nuts not included connect the house power cable to the ventilating fan wires 3 5 14 AWG 2 1 mm 2 is the smallest conductor that shall be used for branch circuit wiring 4 Grille attachment 4 1 Loosen grille bracket screw M4x6 and unload grille bracket aA S Grille bracket a 4 2 Mount the grille to the grille bracket by using the mount grille screw M4x30 2 PCS A NELTA 4 2 1 Lock the grille screw M4x30 into the grille bracket Grille screw M4x30 ese ae 4 2 2 Insert the grille bracket module into the main body and use grille bracket screw M4x6 to affix the main body Insert area Grille bracket screw M4x6 4 2 3 Mount the grille onto the main body by using the location screw Main body Grille module 4 2 4 Attach the grille onto the main body by using the grille screw and nut respectively A Grille screw M4x30 breez Signature MODELS SIG80L SIG110L SIG110HL SIG110DL Page 4 4 2 5 Install the light bulb and close the lens cover to lock into plac
4. Turn the POWER switch on MODE switch is off to operate at the user adjustable low speed airflow the LED will be green 5 6 Full speed control mode Turn both the POWER switch amp the MODE switch on to operate at full speed mode LED indicator will be amber When the user turns the MODE switch off the fan will continue to run at full speed until the user adjusted time delay has elapsed The fan will then automatically change to the user adjusted low speed airflow The LED indicator will be green Factory settings low speed airflow at 40CFM time delay at 15 minutes MAINTENANCE WARNING Disconnect the power source before working on the unit Routine maintenance must be done every year CAUTION 1 Never use gasoline benzene thinner or any other such chemicals to clean the ventilating fan 2 Do not allow water to enter the motor 3 Do not soak resin parts in water over 60 C 140 F CLEANING 1 Open lens cover Remove the light bulbs carefully Disassemble the lock screw lock nut and light power connections to remove grille 2 Wash and clean grille CAUTION Do not let water into the lamp base Use a non abrasive kitchen detergent and wipe dry with a clean cloth 3 Remove dust and dirt from the ventilating fan 4 Using a cloth dampened with non abrasive kitchen detergent remove any dirt from ventilating fan Wipe dry with a clean cloth 5 Replace the grille breez Signature MODELS SIG80L S
5. e GU24 Lamp 26W Max Lock lens cover Operation Delay timer control SIG110DL or Humidity preset control SIG110HL Low speed air volume preset control SIG110DL SIG110HL SIG110DL SIG110HL control options control options TIME min CFM 9960 0 2 0 CMF a S o oO Single Models SIG8OL SIG110L 5 1 Single speed control mode Turn the POWER switch on to operate at single speed mode the LED indicator will be green Humidity Models SIG110HL 5 2 Humidity control mode Turn the POWER switch on to operate at humidity control mode the LED indicator will be blue When the ambient humidity is higher than the user adjustable set point the fan will run at full speed When the ambient humidity is lower than the set point the fan will continue to run at full speed until a 10 minute time delay has elapsed and then will automatically change to the user adjustable low speed airflow 5 3 Full speed mode Turn the MODE switch on to operate at full speed mode the LED indicator will be amber 5 4 Humidity tolerance is about 10 As the fan is used throughout the years dust will accumulate periodically This will influence the precision of the humidity detector Readjusting the humidity switch will address this issue Factory setting low speed airflow 40CFM humidity 60 RH A NELTA Dual Speed Models SIG110DL 5 5 Low speed control mode
6. ent 1 2 Fig F 2 1 Insert the 4 duct not included into the duct connector and tape all ductwork connections to make them secure and airtight Fig F 2 2 Install the duct with a gradient 1 2 to the outside 3 Connect wiring 3 1 Follow all local electrical and ANSI NFPA70 safety codes 3 2 NEVER place a switch where it can be reached from a tub or shower 3 3 Connect wires as shown in the wiring diagrams Single Speed Models SIG8OL SIG110L JUNCTION BOX SWITCH BOX OFF RED o ON k L WHITE LIGHT SWITCH hg N OFF YELLOW ON K L WHITE NIGHT LIGHT SWITCH e N OFF BLACK o ON A E WHITE POWER SWITCH e N GREEN g GRD RE BLACK YELLOW WHITE GROUND ON OFF SWITCH SWITCH BOX bare purchase separately NIGHT LIGHT POWER LIGHT SWITCH SWITCH SWITCH TT 120 VAC LINE IN WIRING PLATE Db EEZ Signature MODELS SIG80L SIG110L SIG110HL SIG110DL Humidity Models SIG110HL Dual Speed Models SIG110DL Page 3 JUNCTION BOX SWITCH BOX OFF RED A OVO o Oon si WHITE LIGHT SWITCH OVO e gt N OFF YE
7. onics shall not be liable for any indirect incidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict product liability or otherwise This warranty does not extend to fluorescent lamp starters and tubes The warranty does not cover if user does not comply with manufacturer s installation manual To qualify for warranty service you must notify Delta Electronics at the address or telephone number below Delta Electronics shall have no liability to the original owner user with respect to any defect caused by abuse misuse neglect improper transportation or storage improper testing improper installation improper operation improper use improper maintenance improper repair improper alteration improper modification tampering or accident of products or parts thereof or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products specifications Address 4405 Cushing Parkway Fremont CA 94538 US Toll Free Number 1 888 979 9889
8. qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities When cutting or drilling into the wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors 10 If this unit will be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit Do not use this unit with any other solid state control devices Solid state control devices may cause harmonic distortion which can cause a motor humming noise NEVER place a switch where it can be reached from a tub or shower Required for installation in Canada only Do not install in a ceiling thermally insulated to a value greater than R40 Turning angle too large Duct shrink S Too many elbows Elbow near the body Body S Q Fig A CAUTION 1 For general ventilating use only Do not use to exhaust ha
9. s Bag l breez Signature MODELS SIG80L SIG110L SIG110HL SIG110DL Page 2 Note Remove the tape from the damper and adaptor before installation ds 1 1 1 3 1 4 1 5 1 6 1 7 Using suspension brackets Sliding suspension brackets are available to allow the housing to be positioned between joists up to a span of 24 Insert the suspension brackets into the channels on the housing Make sure the tabs face up as shown Fig C Extend the suspension brackets to fit the width of the joists Hold the fan in place by wrapping the suspension bracket tabs around the bottom of the joist Make sure the fan body is level and perpendicular to the joist Fig D amp E Ensure that the distance between the ceiling and fan body is appropriate for mounting the grille Secure the suspension brackets to the joists with nails or by using the tapping screws p 4x25 through holes near nails Secure the suspension bracket to the fan body using the screws 8 32 x 1 4 Follow steps 2 to 6 of the installation guide to complete installation Body Suspension Bracket Suspension Bracket II 16 406mm 19 2 487mm i 24 609mm i OH A NELTA 2 Duct connection Duct connector Inside Outside Tape Body i Duct 5 BN Ceiling Gradi
10. zardous or explosive materials and vapors Not for use in cooking areas Fig B This product must properly connect to the grounding conductor of the supply circuit To reduce the risk of injury to persons install the fan at least 7 feet 2 1m above the floor Cooking area Do not install above or ge inside this area para Vi Cooking Equipment floor Fig B A NELTA SUPPLIED ACCESSORIES Part name Appearance Quantity Grille A 1 Tapping screw 4x25 al Screw 8 32x1 4 Grille bracket screw M4x6 gp amp Grille screw M4x30 ON gt 2 Nut M4x4 4 Duct connector Duct screw M4x12 Suspension bracket 13 318 5 Suspension bracket 13 318 5 Grille bracket 9 68 GU24 base bulb lamp 26W E12 base bulb lamp 4W Inches mm INSTALLATIONS Attach Duct Connector Option 1 secure using the duct screw M4X12 Attach the duct connector from the outside and Insert tab into slot in housing Duct screw M4X12 from Parts Bag kO Option 2 Attach the duct connector from the housing can inside and secure using the duct screw M4X12 Pull existing ductwork into Housing Insert tab into slot in Housing Duct screw M4X12 from Part