Home
Fahrenheat NPH4AB Instructions / Assembly
Contents
1. masonry walls use metal expansion shields or toggle bolts Never use bolts smaller 1 4 diameter Replace the heater in the stand and tighten knobs to lock in place Two KEYHOLE SLOT MOUNTING HOLES ARE 16 O C USE KEYHOLES FOR WALL MOUNTING large rubber washers go between heater and stand one on either side REMEMBER The electrical outlet must be within reach of the six foot cord Be sure to provide enough clearance to pivot heater and reach adjustment knobs CEILING MOUNT This heater may be mounted to any ceiling that will support the weight of the heater First remove the mounting stand from the heater then remove four rubber TO PREVENT HEATER FROM POSSIBLY FALLING DO NOT USE KEYHOLE SLOTS FOR CEILING MOUNT APPLICATION SEE ALSO WARNING NO 13 grommets from stand Secure stand to structural members of ceiling with four 1 4 diameter bolts not provided In wood joist use 1 1 2 long lag bolts In steel beams use machine bolts secured with nuts and lockwash ers Never use bolts smaller than 1 4 diameter USE CIRCULAR HOLES FOR CEILING MOUNTING DO NOT USE KEYHOLES Replace the heater in the stand and tighten knobs to lock in place Two large rubberwashers go between heater and stand one on either side REMEMBER The electrical outlet must be within reach of the six foot cord Be sure to provide enough clearance to pivot heater and reach adjustment knobs HEATER OPERATION To o
2. Marley Engineered Products c US FILE E21609 Lo p ia ex PH4AB Portable Unit Heater Installation amp Maintenance Instructions Dear Owner Congratulations Thank you for purchasing this new heater manufactured by Marley Engineered Products You have made a wise investment selecting the highest quality product in the heating indus try Please carefully read the installation and maintenance directions shown in this manual You should enjoy years of efficient heating comfort with this product from Marley Engineered Products the indus try s leader in design manufacturing quality and service Read Carefully These instructions contain vital infor mation for the proper installation use and efficient opera tion of the heater Carefully read these instructions before installation operation or cleaning of the heater Failure to adhere to the instructions could result in fire electric shock serious personal injury death or property damage Save these instructions and review frequently for continu ing safe operation and instruction future users 1 2 Connect to properly grounded outlets only Check heater voltage and amperage on back of heater to make sure it agrees with the electric service supplied Ground fault circuit protection is required if heater is used in damp areas such as basements or garages This is not suit able for use in wet or very humid locations Do not use outdoors Never loc
3. NOT OPERATE WITHOUT STAND ATTENTION NE FAITES PAS FONCTIONNER ATTENTION LE RADIATEUR SANS SOCLE MARLEY ENGINEERED PRODUCTS BENNETTSVILLE SC 29512 4104 2099 002 LIMITED WARRANTY All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation except heating elements which are warranted against defects in workmanship and materials for five years from date of installation This warranty does not apply to damage from accident misuse or alteration nor where the connected volt age is more than 5 above the nameplate voltage nor to equipment improperly installed or wired or maintained in violation of the prod uct s installation instructions All claims for warranty work must be accompanied by proof of the date of installation The customer shall be responsible for all costs incurred in the removal or reinstallation of products including labor costs and shipping costs incurred to return products to Marley Engineered Products Service Center Within the limitations of this warranty inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Service Center and we will repair or replace at our option at no charge to you with return freight paid by Marley It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products THE ABOVE WARRANTIES ARE IN LIEU
4. OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WAR RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT STRICT LIABILITY OR CONTRACT Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For the address of your nearest authorized service center contact Marley Engineered Products in Bennettsville SC at 1 800 642 4328 Merchandise returned to the factory must be accompanied by a return authorization and service identification tag both available from Marley Engineered Products When requesting return authorization include all catalog numbers shown on the products HOW TO OBTAIN WARRANTY SERVICE AND WARRANTY PARTS PLUS GENERAL INFORMATION YC M a rl 1 Warranty Service or Parts 1 800 642 4328 CF 2 Purchase Replacement Parts 1 800 654 3545 Engineered Products 3 General Product Information www marleymep com 470 Beauty Spot Rd East Note When obtaining service always have the following Bennetisville SG 29512 USA 1 Model number of the product 2 Date of manu
5. ate heater where it may fall into a bathtub or other water container Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock fire or damage the heater To prevent a possible fire do not block air intakes or exhaust The Employees of Marley Engineered Products in any manner Do not use soft surfaces like a bed where openings may become blocked Clean as often as neces sary to prevent dust from clogging the grilles or element fins Keep all electrical cords drapes paper plastics and other combustibles away from heater Do not run cord under carpeting Do not cover cord with throw rugs runners etc To prevent entanglement or damage route cord away from high traffic areas A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are repaired by a reputable repair service If this heater or its power cord become damaged or malfunc tion in any way unplug heater discontinue use and have unit repaired by a reputable repair service Do not operate heater without stand Do not use an extension cord with this heater Do not cut off plug and wire heater directly When heater is to be wall or ceiling mounted the anchoring provisions must be of sufficient strength to support the total weight of the heater plus the weight of the mounting provi sions Failure to properly secure the supporti
6. facture 3 Part number or description ECR 38011 5200 2195 004 10 08
7. intake grille use vacuum with brush attachment or high pressure air The motor is permanently lubricated Do not operate the heater with a damaged cord or plug or if the heater mal functions or has been damaged in any manner Return heater to autho rized service facility for examination electrical or mechanical adjustment or repair Call the toll free number listed for assistance in locating the Marley autho rized service center in your area TO RESET SAFETY THERMAL LIMIT CONTROL Your heater is equipped with a manual reset safety thermal limit control that will automatically turn the heater off to prevent a fire if the heater over heats This control is located on front of the heater just above the thermo stat and is marked PUSH TO RESET To reset allow the heater to cool then simply push the red button in until it snaps The heater should imme diately return to normal operation CEAR OPERATION OF THE SAFETY THERMAL LIMIT CONTROL INDI CATES THE HEATER HAS BEEN SUBJECTED TO SOME ABNORMAL CONDITION IT IS RECOMMENDED THAT THE HEATER BE CHECKED BY A REPUTABLE ELECTRICIAN OR REPAIR SERVICE TO INSURE THE HEATER HAS NOT BEN DAMAGED NAMEPLATE MODEL NO PH4AB pate cope 0207 PORTABLE HEATER VOLTS AC WATTS AMPS 60 HZ HI LO H LO 240 4000 2660 16 7 11 1 O 220 3360 2240 15 3 10 2 2F68 LISTED 208 3000 2000 14 4 9 6 MOVABLE HEATER CAUTION UNPLUG BEFORE SERVICING CAUTION DO
8. ng members of the building structure could allow the heater to fall SAVE THESE INSTRUCTIONS GENERAL Prior to operating heating make sure the electrical outlet is of the configu ration and capacity appropriate for the heater When heater is wall or ceiling mounting provisions must be made to bun dle or otherwise prevent excess power cord from draping loose In workshops locate heater away from sources of wood dust FLOOR APPLICATION The heater as received is set up for floor mounting Place the heater on floor or other flat surface and insert the plug into the proper wall outlet The heater can be adjusted to redirect the airstream To do this simply loosen the knob on either side of the heater then pivot heater to desired position and re tighten both knobs BE CAREFUL NOT TO DIRECT THE AIRSTREAM AT DRAPERIES FURNITURE OR OTHER OBJECTS THAT COULD BE DAMAGED BY HEAT DO NOT USE HEATER ON FLOOR WITHOUT STAND IN PLACE DO NOT SUE THE HEATER WHERE A SMALL CHILD MAY FALL OVER THE HEATER DO NOT PLACE THE HEATER WHERE THE POWER CORD MAY BE WALKED ON TRIPPED OVER OR OTH ERWISE SUBJECTED TO HARD USAGE WALL MOUNT SEE WARNING NO 13 This heater may be mounted on any wall that will support the weight of the heater First remove the mounting stand from the heater then remove four rubber grommets from stand Secure stand to structural members of wall with four 1 4 dia X 1 1 2 long lag bolts not provided In
9. perate the heater first select either high or low position on the heat selector switch then turn the thermostat knob as far as it will go in the clockwise direction The indicator light will come on and remain on as long as the heater is in the operating mode when the room temperature reach es the desired level slowly turn the thermostat knob counterclockwise until the thermostat clicks The heater off turn thermostat knob as far as it will go in the counterclockwise direction until the indicator light is off The fan selector switch allows continuous or cycling fan operation by selecting either the ON or Auto position respectively CLEANING AND STORAGE HEAT SW 4 HI ELEMENTS FRONT O OE Re mna TG OQ INDICATOR LIGHT MANUAL RESET THERMAL UNIT Turn thermostat off then remove plug from electrical outlet before cleaning heater Use a soft cloth for dusting For cleaning use only a damp rag and nonabrasive dish detergent Do not use abrasive or chemical cleaners as these may harm the finish THERMOSTAT If heater is used in a very dusty location use a vacuum cleaner dust brush to remove dust and other foreign material from the grilles Always unplug cord and wrap around heater when not in use Move floor mounted heaters to a safe location for storage SERVICE This heater does not require any routine maintenance other than occa sional cleaning to prevent clogging of intake grille opening To clean air