Z-Flex 2ZFLKIT0435 Instructions / Assembly
Contents
1. The air space clearance between the masonry chimney exterior and combustible materials should be checked to verify that the chimney is in accordance with the clearance specifications contained in the NFPA 211 Standard or other recognized major building codes i e on an exterior chimney clearance is 1 while on an interior chimney clearance is 2 The SF Liner is intended for installation into masonry chimneys that are used for the natural draft venting of gas liquid and solid fuel fired residential type appliances in which the maximum continuous flue gas outlet temperatures do not exceed 1000 F 538 C The following list details only some intended uses of SF chimney liner If your appliance is not on this list and you are not sure if it is appropriate to use with SF liner contact the appliance manufacturer prior to installation e Furnace e Boiler e Water Heater e Burner e Fireplaces Inserts e Ranges e Wood Stove e Pellet Stoves e Clothes Dryer 11 The recommended minimum air space clearance between the SF 11 Liner and the chimney wall are 1 in accordance with major recognized standards Joining of two parts such as two liners should be done using a C Connect Minimum and Maximum Clearances LINER DIAMETER IN MINIMUM CHIMNEY DIMENSIONS 3 6X6 4 7X7 5 8X8 6 9 X9 7 10 X 10 8 11X11 9 12 X 12 Maximum Chimney Height 65 Feet
2. SF chimney liner system are available from Z Flex Inc Page 10 of 11 A THE NOVAFLEX Z FLEX Lifetime Liner Warranty Z Flex Inc warrants its stainless steel chimney liners to the original purchaser or if purchased by a contractor to the end user The warranty is valid for as long as the original purchaser owns the property in which the liner is installed provided it is installed according to U L installation instructions Deviating from the installation and use instructions included with the liner will void the warranty Z Flex warrants that at the time of shipping the stainless steel chimney liner will be free of manufacturer s defects in material and or workmanship Liability under the warranty shall be limited to the replacement of the liner and accessories found to be defective according to the terms of the warranty and shall not include replacement installation or other costs IMPORTANT Z Flex Chimney Liners are designed to be used with these fuels only natural gas propane gas oil and seasoned hardwood The following fuels are not recommended for use in Z Flex chimney liners coal ocean driftwood or garbage Excessive condensation with high chlorine content will corrode some stainless steel Where these conditions prevail we recommend AL29 4C Stainless Steel Liners Refer to equipment manufacturer s installation instructions for proper liner material for appliances which produce condensation Excessive creosot
3. Z FLEX THE L NOVAFLEX All FUEL CHIMNEY LINER INSTALLATION GUIDE c UL Dus LISTED UL 1777 FOR SAFETY S SAKE Chimney relining and chimney repairs must be done with the utmost of care Please ensure before starting that the safety aspect of the installation has been looked after Secure your ladders and scaffolding wear protective gear and the appropriate footwear and gloves before starting Avoid problems through proper safety measures ensuring every installation is an accident free installation MODEL SF Z FLEX SF CHIMNEY LINING SYSTEM SF INSTALLATION GUIDE VER 1 1 US 10 12 Page 1 of 11 The Z Flex Flexible Liner is intended for use as a chimney liner in masonry chimneys for oil gas or wood fired residential heating appliances with maximum running temperature of 1000 F 538 C and occasional 1400 F 760 C temperatures Kits Contains Example Wood Burning Stove Example Fireplace Insert PartID 2ZFLKIT Part ID 20ILKIT__sit e Z Flex S S Flexible Liner e Z Flex S S Flexible Liner e Rain Cap e Rain Cap e Top Support e Top Support e Chimney Flashing e Chimney Flashing e Lock N Go Tee e Insert Connector Manufacturer s address Z Flex U S Inc 20 Commerce Park North Bedford NH 03110 6911 GENERAL INSTRUCTIONS WARNING Do not use any materials other than those specified in this instruction 1 Read the installation instructions carefully prior to installing the chimney li
4. High Minimum Chimney Height 10 Feet High Minimum Brick Thickness 3 1 2 Inches Thick Page 3 of 11 13 Clearance from connectors to unprotected combustible material shall be in accordance with the table below ref NFPA 211 Description of Appliance Minimum Clearance Inch mm Gas appliances without draft hoods 18 457 Oil and sold fuel appliances 18 457 Boilers and furnaces equipped with listed Df 229 Gas burners and with draft hoods 9 229 Listed gas appliances with draft hoods 6 152 NOTE 1 These clearances apply except if the listing of an appliance specifies different clearance in which case the listed clearance takes precedence NOTE 2 These clearances apply except if a listed wall penetration assembly is used 14 Ensure access to clean out tee is in accordance with the enforcing authorities and clearances are maintained to your local building codes INSTALLATION OF INSULATION KIT To be used for wood burning appliances Unroll the Flexible Liner to the maximum allowable length Now get ready to insulate the liner with the Z Flex Insulation blanket and a covering cloth First wrap the liner with the Insulation Blanket allow 2 overlap Use metal tape to hold the insulation Then wrap the liner with the covering cloth and use provided gear clamps to secure it down This outer wrap is a woven fiberglass cloth and has a recommended limit to continuous use 538 C 1000 R UL listed for wood b
5. OTHER THAN THOSE SPECIFIED IN THE INSTALLATION INSTRUCTIONS B Creosote and Soot Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combined with expelled moisture forms creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this makes an extremely hot fire The chimney should be inspected every two 2 months during the heating season to determine if a creosote or soot buildup has occutred If creosote or soot has accumulated it should be removed to reduce the risk of chimney fire C The recommended method of cleaning your Z Flex Liner is with a poly chimney brush approximately 1 8 larger than the diameter of your liner The liner should be brushed until all creosote and soot have been removed D It is recommended to have the chimney lining system checked by a qualified chimney inspector such as a certified chimney sweep at least once annually following the initial installation of the lining system E Any heating appliance connected to the chimney liner must not have a flue outlet size larger than the chimney liner area at its smallest point PARTS COMMON TO Z FLEX LINER SYSTEMS Base Tee Lock N Go Tee Insert Connector Chimney Flashing Z Max Flashing Deluxe Rain Cap Z Max Rain Cap Top Suppott The replacement parts components for the
6. Tel 1 800 654 5600 In NH 603 669 5136 Z FLEX Warranty Registration Card For this warranty to be effective this card must be completed upon purchase of the covered liner and returned to Z FLEX Inc NAME ADDRESS LINER PURCHASED FROM DATE OF INSTALLATION FIREPLACE INSERT STOVE OR FURNACE MODEL Page 11 of 11
7. Fireplace CLEAN OUT QUT TEE Insert Installation 1 Installation 2 Installation 3 FIREPLACE INSERT INSTALLATION 1 Prepare the chimney flue opening using best practice following all codes amp standards having jurisdiction 2 Connect the Insert Connector by tightening up on gear clamp around liner in place of the Lock N Go Tee in step 3 above 3 Attach the prepared nose cone to the Connector and guide the liner down the chimney into the fireplace opening 4 Remove the nose cone and fully insert the Insert Connector in the flue opening of the fireplace insert 5 Secure the Insert Connector in the fireplace insert using appropriate fastener to the flue outlet collar and by bending back the tabs to the underside of fireplace insert Note to installer If there is no collar present on the outlet of the fireplace insert for the Insert Connector to fasten onto bend the tabs of the Insert Connector back to the underside of fireplace insert fire chamber and affix using best practice method and or approved cement 6 Insert can now be set into place pulling the liner slack up through chimney 7 Continue on from Step 8 above to finish off Page 9 of 11 IMPORTANT Follow Fireplace Insert instructions for flue connection when applicable MAINTENANCE INSTRUCTIONS Manufacturet s address Z Flex Inc 20 Commerce Park North Bedford NH 03110 6911 Tel 1 800 654 5600 In NH 603 669 5136 A WARNING DO NOT USE ANY MATERIAL PARTS
8. INSTALLING WITH FIREPLACE INSERTS USE A INSERT CONNECTOR See Fireplace Insert Installation below amp Typical Installation 3 Page 5 of 11 FLEXIBLE LINER oR TABED er 6 Fully open the gear clamp on the Tee branch of the Lock N Go Tee and insert into the chimney inlet 7 Continue to lower the Lock N Go Tee body down through the opened gear clamp of Tee branch Align through branch and secure branch to the body by tightening the gear clamp from inside the branch until snug Using a standard mortar mix cement around the horizontal portion of the Lock N Go Tee at the inlet opening Corrugated Flex Or Smoothcore Flex SS Clamp Lock N Go Tee Body Tee z Tee Branch Cap gt a ae Tighten Gear Clamp Page 6 of 11 8 Allow at least 6 12 of liner to extend above the top of the chimney for attaching the Top Support and Rain Cap Next place the Chimney Flashing over the liner and secure it to chimney top using suitable anchors Using a quality high temperature sealant caulk all joints and paint as necessary RAIN CAP TOP SUPPORT FLASHING CAULK ING 6 T0 12 NCHES J I il N A EEE E FLEX LINER nl 9 Slide Top Support over liner down to the top of the flashing collar allowing about a 1 overlap on the flashing collar Trim the liner level to top of Support using a knife or hacksaw Next insert Rain Cap into the liner Tighten up on gear clamp supp
9. e accumulation sulphur residue from burning coal or the use of unapproved chemical cleaners may cause chimney fires that could warp the liner or may corrode the liner Such misuse will void the warranty To activate the warranty the purchaser or end user must complete and return the Z Flex warranty registration card within ninety 90 days of installation Upon receipt of written notice of any defect Z Flex reserves the right to examine or engage others to examine the liner Such examination must establish reasonable proof of defective material or workmanship justifying replacement The sole remedy for breach of any and all warranties and the sole remedies for Z Flex s liability of any kind shall be limited to the remedies provided herein Z Flex shall not be liable for any special incidental indirect or consequential damages or for any claim against the purchaser or end user by any other party EXCEPT AS SPECIFICALLY PROVIDED HEREIN Z FLEX DOES NOT MAKE ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE Some states do not allow the exclusion of implied warranties or the limitation or exclusion of liability for incidental or consequential damages so the above limitations may not apply to you You may also have other rights which vary from state to state For further information call or write to Z FLEX INC 20 Commerce Park North Bedford NH 03110 6911
10. lied on Top Support crimping liner onto the Rain Cap base allowing it to overlap the flashing collar preventing any rain from getting between flashing collar and liner Page 7 of 11 Z MAX ADDENDUM The Z Max Rain Cap and Z Max Flashing in combination eliminate the need for a Top Support when used in the Z Flex Chimney Liner System The Z Max Flashing with integrated gear clamp affixes directly to the chimney liner by tightening the gear clamp Trim the liner to size above the Z Max Flashing Align the Z Max Rain Cap over top of the gear clamp of the Z Max Flashing and tighten down on the gear clamp resulting in a double lock fail safe cap see illustrations below Ji ex LINER jii L Page 8 of 11 9 Typical installations RAIN CAP RAIN CAP L a seat TOP SUPPORT FLASHING TOP SUPPORT pee o Rain Cag lt A m P EE E BE a a Top Support gt N na a Baer INSULATION Flashing grn am Cn QC 4 T TI oo a a C FLEXIBLE _ m m ma n a JL LINER IO on TroTr O A mam a TTT E E L a i Flexible Liner nms H O TTI rrr O er o HE E LITT Cd E SF LINER a LLL i ft an oo J To Loo SS mee eee RES a SS rt ES fof L ff fT 1 BES 1o SS bee Ep ooo O HE LE 5 OC OC j ie pa C IL insert Connector Lae FLEX TEE lt l E MORTAR Ce O a j N OPTIONAL CLEAN
11. ner If doubts exist contact your local distributor or Z Flex at 1 800 654 5600 in NH 603 669 5136 Clean and repair chimney as required NOTE Removal of all tar glazed creosote is a must prior to installation of chimney liner Also cracked loose or missing bricks mortar or other materials that could inhibit correct installation of the chimney lining system should be removed repaired Contact your local building or fire officials about any restrictions and inspections required The wall penetration assemblies must not be located directly behind a heating appliance The chimney liner must not be sized less than that specified in the appliance manufacturet s instructions The liner may be purchased in various lengths to suit chimney height If it is necessary a single joint can be allowed to join two liners e Note It is recommended to have the liner in one continuous length however if liner must be joined to achieve correct length use Part ID 2CNNTRC__ Nose cone amp insulation kits are catalog items sold separately Be sure to extend the chimney liner to conform to applicable building codes local amp national That is chimneys are required to extend at least three 3 feet above the highest point where they pass through the roof of a building and at least two 2 feet higher than any portion of the building within 10 feet see illustration below Page 2 of 11 10 2 FEET IF WITHIN 10 FEET
12. urning Note When securing the insulation with gear clamps to the liner Do not secure at the end of the liner Make certain to allow space at the ends of the liner for the fittings to connect directly to the liner GEAR CLAMP FLEXIBLE LINER COVERING CLOTH INSULATION BLANKET Cee aa pae TUUSA 45 Ute Ae 2in overlap 6S 4 ee Pips paar i Page 4 of 11 3 Next install Lock N Go Tee Base onto liner Insert liner into top of tee and snug up on gear clamp around liner The branch will be installed later Note IF Insulation Blanket is used Peel back the insulation in order to make a direct connection between the gear clamp of the fitting to the liner then re cover Flex Liner Flex Liner Lock N Go Tee body Lock N Go a Nose Cone Nose Cone Rope f FA 4 Now the Flexible Liner is ready to be installed in the chimney Take a rope slightly longer than the liner and make a knot at one end of the rope and place other end through the backside of the Nose Cone and pull the rope until the knot is completely in the Nose Cone Place the Nose Cone at the end of liner or bottom of Lock N Go Tee To secure use duct tape or other suitable fastener 5 Guide the liner down the chimney Nose Cone first using the attached rope to the inlet opening Align opening on base of Lock N Go tee with chimney inlet Remove Nose Cone through available opening NOTE LOCK N GO TEE NOT REQUIRED WHEN
Download Pdf Manuals
Related Search
Related Contents
Nortel Networks WEB OS 212777 User's Manual IMS1000 Installation and User Manual Page 1 保証書 く必ずご記入下さい) お名前 様 電話番号 お買い上げ日 Kambrook Fan KFA715 User's Manual Channel Switch CS Manual EXAMEN DE FIN D`ETUDES SECONDAIRES directives importantes lire et conserver Manuale utente Copyright © All rights reserved.